-
High-Precision Physics Experiments at Huizhou Large-Scale Scientific Facilities
Authors:
FengPeng An,
Dong Bai,
Siyuan Chen,
Xurong Chen,
Hongyue Duyang,
Leyun Gao,
Shao-Feng Ge,
Jun He,
Junting Huang,
Zhongkui Huang,
Igor Ivanov,
Chen Ji,
Huan Jia,
Junjie Jiang,
Soo-Bong Kim,
Chui-Fan Kong,
Wei Kou,
Qiang Li,
Qite Li,
Jiajun Liao,
Jiajie Ling,
Cheng-en Liu,
Xinwen Ma,
Hao Qiu,
Jian Tang
, et al. (16 additional authors not shown)
Abstract:
In response to the capabilities presented by the High-Intensity Heavy Ion Accelerator Facility (HIAF) and the Accelerator-Driven Subcritical System (CiADS), as well as the proposed Chinese Advanced Nuclear Physics Research Facility (CNUF), we are assembling a consortium of experts in relevant disciplines--both domestically and internationally--to delineate high-precision physics experiments that l…
▽ More
In response to the capabilities presented by the High-Intensity Heavy Ion Accelerator Facility (HIAF) and the Accelerator-Driven Subcritical System (CiADS), as well as the proposed Chinese Advanced Nuclear Physics Research Facility (CNUF), we are assembling a consortium of experts in relevant disciplines--both domestically and internationally--to delineate high-precision physics experiments that leverage the state-of-the-art research environment afforded by CNUF. Our focus encompasses six primary domains of inquiry: hadron physics--including endeavors such as the super eta factory and investigations into light hadron structures; muon physics; neutrino physics; neutron physics; the testing of fundamental symmetries; and the exploration of quantum effects within nuclear physics, along with the utilization of vortex accelerators. We aim to foster a well-rounded portfolio of large, medium, and small-scale projects, thus unlocking new scientific avenues and optimizing the potential of the Huizhou large scientific facility. The aspiration for international leadership in scientific research will be a guiding principle in our strategic planning. This initiative will serve as a foundational reference for the Institute of Modern Physics in its strategic planning and goal-setting, ensuring alignment with its developmental objectives while striving to secure a competitive edge in technological advancement. Our ambition is to engage in substantive research within these realms of high-precision physics, to pursue groundbreaking discoveries, and to stimulate progress in China's nuclear physics landscape, positioning Huizhou as a preeminent global hub for advanced nuclear physics research.
△ Less
Submitted 28 April, 2025;
originally announced April 2025.
-
A mechanics--based perspective on the function of human sphincters during functional luminal imaging probe manometry
Authors:
Guy Elisha,
Sourav Halder,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insi…
▽ More
Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insights. However, limited work has been done to explain the mechanics of these pressure-CSA loops. This work presents a consolidated picture of pressure-CSA loops of different sphincters. Clinical data reveal that although sphincters have a similar purpose (controlling the flow of liquids and solids by opening and closing), two different pressure-CSA loop patterns emerge: negative slope loop (NSL) and positive slope loop (PSL). We show that the loop type is the result of an interplay between (or lack thereof) two mechanical modes: (i) neurogenic mediated relaxation of the sphincter muscle and (ii) muscle contraction proximal to the sphincter which causes mechanical distention. We conclude that sphincters which only function through mechanism (i) exhibition NSL whereas sphincters which open as a result of both (i) and (ii) display a PSL. This work provides a fundamental mechanical understanding of human sphincters. This can be used to identify normal and abnormal phenotypes for the different sphincters and help in creating physiomarkers based on work calculation.
△ Less
Submitted 17 September, 2022;
originally announced September 2022.
-
Pressure -- area loop based phenotypic classification and mechanics of esophagogastric junction physiology
Authors:
Guy Elisha,
Sourav Halder,
Shashank Acharya,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed materials to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles result in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics behind the opening and closing…
▽ More
The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed materials to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles result in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics behind the opening and closing cycle of the EGJ provides a mechanistic insight into its function and can help identify the underlying conditions that cause its degradation. Using clinical FLIP data, we plotted the pressure-area hysteresis at the EGJ location and distinguished two major loop types, a pressure dominant loop (PDL) and a tone dominant loop (TDL). In this study, we aimed to identify the key characteristics that define each loop type and find what causes the inversion from one loop to another. To do so, the clinical observations were reproduced using 1D simulations of flow inside a FLIP device located in the esophagus, and the work done by the EGJ wall over time was calculated. This work was decomposed into active and passive components, which revealed the competing mechanisms that dictate the loop type. These mechanisms are esophagus stiffness, fluid viscosity, and the EGJ relaxation pattern. In PDL, the leading source of energy in the cycle is coming from the fluid pressure increase from the peristaltic contraction wave, and in TDL the leading source of energy in the cycle is coming from the contraction and relaxation of the EGJ tone.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
Peristaltic regimes in esophageal transport
Authors:
Guy Elisha,
Shashank Acharya,
Sourav Halder,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
A FLIP device gives cross-sectional area along the length of the esophagus and one pressure measurement, both as a function of time. Deducing mechanical properties of the esophagus including wall material properties, contraction strength, and wall relaxation from these data is a challenging inverse problem. Knowing mechanical properties can change how clinical decisions are made because of its pot…
▽ More
A FLIP device gives cross-sectional area along the length of the esophagus and one pressure measurement, both as a function of time. Deducing mechanical properties of the esophagus including wall material properties, contraction strength, and wall relaxation from these data is a challenging inverse problem. Knowing mechanical properties can change how clinical decisions are made because of its potential for in-vivo mechanistic insights. To obtain such information, we conducted a parametric study to identify peristaltic regimes by using a 1D model of peristaltic flow through an elastic tube closed on both ends and also applied it to interpret clinical data. The results gave insightful information about the effect of tube stiffness, fluid/bolus density and contraction strength on the resulting esophagus shape through quantitive representations of the peristaltic regimes. Our analysis also revealed the mechanics of the opening of the contraction area as a function of bolus flow resistance. Lastly, we concluded that peristaltic driven flow displays three modes of peristaltic geometries, but all physiologically relevant flows fall into two peristaltic regimes characterized by a tight contraction.
△ Less
Submitted 29 December, 2021;
originally announced December 2021.
-
Esophageal virtual disease landscape using mechanics-informed machine learning
Authors:
Sourav Halder,
Jun Yamasaki,
Shashank Acharya,
Wenjun Kou,
Guy Elisha,
Dustin A. Carlson,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
The pathogenesis of esophageal disorders is related to the esophageal wall mechanics. Therefore, to understand the underlying fundamental mechanisms behind various esophageal disorders, it is crucial to map the esophageal wall mechanics-based parameters onto physiological and pathophysiological conditions corresponding to altered bolus transit and supraphysiologic IBP. In this work, we present a h…
▽ More
The pathogenesis of esophageal disorders is related to the esophageal wall mechanics. Therefore, to understand the underlying fundamental mechanisms behind various esophageal disorders, it is crucial to map the esophageal wall mechanics-based parameters onto physiological and pathophysiological conditions corresponding to altered bolus transit and supraphysiologic IBP. In this work, we present a hybrid framework that combines fluid mechanics and machine learning to identify the underlying physics of the various esophageal disorders and maps them onto a parameter space which we call the virtual disease landscape (VDL). A one-dimensional inverse model processes the output from an esophageal diagnostic device called endoscopic functional lumen imaging probe (EndoFLIP) to estimate the mechanical "health" of the esophagus by predicting a set of mechanics-based parameters such as esophageal wall stiffness, muscle contraction pattern and active relaxation of esophageal walls. The mechanics-based parameters were then used to train a neural network that consists of a variational autoencoder (VAE) that generates a latent space and a side network that predicts mechanical work metrics for estimating esophagogastric junction motility. The latent vectors along with a set of discrete mechanics-based parameters define the VDL and form clusters corresponding to the various esophageal disorders. The VDL not only distinguishes different disorders but can also be used to predict disease progression in time. Finally, we also demonstrate the clinical applicability of this framework for estimating the effectiveness of a treatment and track patient condition after a treatment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
A Fully Resolved Multiphysics Model of Gastric Peristalsis and Bolus Emptying in the Upper Gastrointestinal Tract
Authors:
Shashank Acharya,
Sourav Halder,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Over the past few decades, in silico modeling of organ systems has significantly furthered our understanding of their physiology and biomechanical function. In this work, we present a detailed numerical model of the upper gastrointestinal (GI) tract that not only accounts for the fiber architecture of the muscle walls, but also the multiphasic components they help transport during normal digestive…
▽ More
Over the past few decades, in silico modeling of organ systems has significantly furthered our understanding of their physiology and biomechanical function. In this work, we present a detailed numerical model of the upper gastrointestinal (GI) tract that not only accounts for the fiber architecture of the muscle walls, but also the multiphasic components they help transport during normal digestive function. Construction details for 3D models of representative stomach geometry are presented along with a simple strategy for assigning circular and longitudinal muscle fiber orientations for each layer. Based on our previous work that created a fully resolved model of esophageal peristalsis, we extend the same principles to simulate gastric peristalsis by systematically activating muscle fibers embedded in the stomach. Following this, for the first time, we simulate gravity driven bolus emptying into the stomach due to density differences between ingested contents and fluid contents of the stomach. This detailed computational model of the upper gastrointestinal tract provides a foundation on which future models can be based that seek to investigate the biomechanics of acid reflux and probe various strategies for gastric bypass surgeries to address the growing problem of adult obesity.
△ Less
Submitted 27 March, 2021;
originally announced March 2021.
-
Mechanics Informed Fluoroscopy of Esophageal Transport
Authors:
Sourav Halder,
Shashank Acharya,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Fluoroscopy is a radiographic procedure for evaluating esophageal disorders such as achalasia, dysphasia and gastroesophageal reflux disease (GERD). It performs dynamic imaging of the swallowing process and provides anatomical detail and a qualitative idea of how well swallowed fluid is transported through the esophagus. In this work, we present a method called mechanics informed fluoroscopy (Fluo…
▽ More
Fluoroscopy is a radiographic procedure for evaluating esophageal disorders such as achalasia, dysphasia and gastroesophageal reflux disease (GERD). It performs dynamic imaging of the swallowing process and provides anatomical detail and a qualitative idea of how well swallowed fluid is transported through the esophagus. In this work, we present a method called mechanics informed fluoroscopy (FluoroMech) that derives patient-specific quantitative information about esophageal function. FluoroMech uses a Convolutional Neural Network to perform segmentation of image sequences generated from the fluoroscopy, and the segmented images become input to a one-dimensional model that predicts the flow rate and pressure distribution in fluid transported through the esophagus. We have extended this model by developing a FluoroMech reference model to identify and estimate potential physiomarkers such as esophageal wall stiffness and active relaxation ahead of the peristaltic wave in the esophageal musculature. FluoroMech requires minimal computational time, and hence can potentially be applied clinically in the diagnosis of esophageal disorders.
△ Less
Submitted 23 August, 2020;
originally announced August 2020.
-
Pumping Patterns and Work Done during Peristalsis in Finite-length Elastic Tubes
Authors:
Shashank Acharya,
Wenjun Kou,
Sourav Halder,
Dustin A. Carlson,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Balloon dilation catheters are often used to quantify the physiological state of peristaltic activity in tubular organs and comment on their ability to propel fluid which is important for healthy human function. To fully understand this system's behavior, we analyzed the effect of a solitary peristaltic wave on a fluid-filled elastic tube with closed ends. A reduced order model that predicts the r…
▽ More
Balloon dilation catheters are often used to quantify the physiological state of peristaltic activity in tubular organs and comment on their ability to propel fluid which is important for healthy human function. To fully understand this system's behavior, we analyzed the effect of a solitary peristaltic wave on a fluid-filled elastic tube with closed ends. A reduced order model that predicts the resulting tube wall deformations, flow velocities and pressure variations is presented. This simplified model is compared with detailed fluid-structure 3D immersed boundary simulations of peristaltic pumping in tube walls made of hyperelastic material. The major dynamics observed in the 3D simulations were also displayed by our 1D model under laminar flow conditions. Using the 1D model, several pumping regimes were investigated and presented in the form of a regime map that summarizes the system's response for a range of physiological conditions. Finally, the amount of work done during a peristaltic event in this configuration was defined and quantified. The variation of elastic energy and work done during pumping was found to have a unique signature for each regime. An extension of the 1D model is applied to enhance patient data collected by the device and find the work done for a typical esophageal peristaltic wave. This detailed characterization of the system's behavior aids in better interpreting the clinical data obtained from dilation catheters. Additionally, the pumping capacity of the esophagus can be quantified for comparative studies between disease groups.
△ Less
Submitted 18 January, 2021; v1 submitted 20 November, 2019;
originally announced November 2019.
-
A continuum mechanics-based musculo-mechanical model for esophageal transport
Authors:
Wenjun Kou,
Boyce E. Griffith,
John E. Pandolfino,
Peter J. Kahrilas,
Neelesh A. Patankar
Abstract:
In this work, we extend our previous esophageal transport model using an immersed boundary (IB) method with discrete fiber-based structures, to one using a continuum mechanics-based model that is approximated based on finite elements (IB-FE). To deal with the leakage of flow when the Lagrangian mesh becomes coarser than the fluid mesh, we employ adaptive interaction quadrature points for Lagrangia…
▽ More
In this work, we extend our previous esophageal transport model using an immersed boundary (IB) method with discrete fiber-based structures, to one using a continuum mechanics-based model that is approximated based on finite elements (IB-FE). To deal with the leakage of flow when the Lagrangian mesh becomes coarser than the fluid mesh, we employ adaptive interaction quadrature points for Lagrangian-Eulerian interaction equations based on a previous work. In particular, we introduce a new anisotropic adaptive interaction quadrature rule. The new rule permits us to vary the interaction quadrature points not only at each time-step and element but also at different orientations per element. For the material model, we extend our previous fiber-based model to a continuum-based model. We first study a case in which a three-dimensional short tube is dilated. Results match very well with those from the implicit FE method. We remark that in our IB-FE case, the three-dimensional tube undergoes a very large deformation and the Lagrangian mesh-size becomes about 6 times of Eulerian mesh-size. To validate the method in handling fiber-matrix material models, we perform a second study on dilating a long fiber-reinforced tube. Errors are small when we compare numerical solutions with analytical solutions. The technique is then applied to the problem of esophageal transport. We present three cases that differ in the material model and muscle fiber architecture. The overall transport features are consistent with those from the previous model. We remark that the continuum-based model can handle more realistic and complicated material behavior. This is demonstrated in our third case with spatially varying fiber architecture. We find this unique muscle fiber architecture could generate a so-called pressure transition zone. This suggests an important role of muscle fiber architecture in esophageal transport.
△ Less
Submitted 13 September, 2016;
originally announced September 2016.
-
A fully resolved active musculo-mechanical model for esophageal transport
Authors:
Wenjun Kou,
Amneet Pal Singh Bhalla,
Boyce E. Griffith,
John E. Pandolfino,
Peter J. Kahrilas,
Neelesh A. Patankar
Abstract:
Esophageal transport is a physiological process that mechanically transports an ingested food bolus from the pharynx to the stomach via the esophagus, a multi-layered muscular tube. This process involves interactions between the bolus, the esophagus, and the neurally coordinated activation of the esophageal muscles. In this work, we use an immersed boundary (IB) approach to simulate peristaltic tr…
▽ More
Esophageal transport is a physiological process that mechanically transports an ingested food bolus from the pharynx to the stomach via the esophagus, a multi-layered muscular tube. This process involves interactions between the bolus, the esophagus, and the neurally coordinated activation of the esophageal muscles. In this work, we use an immersed boundary (IB) approach to simulate peristaltic transport in the esophagus. The bolus is treated as a viscous fluid that is actively transported by the muscular esophagus, which is modeled as an actively contracting, fiber-reinforced tube. A simplified version of our model is verified by comparison to an analytic solution to the tube dilation problem. Three different complex models of the multi-layered esophagus, which differ in their activation patterns and the layouts of the mucosal layers, are then extensively tested. To our knowledge, these simulations are the first of their kind to incorporate the bolus, the multi-layered esophagus tube, and muscle activation into an integrated model. Consistent with experimental observations, our simulations capture the pressure peak generated by the muscle activation pulse that travels along the bolus tail. These fully resolved simulations provide new insights into roles of the mucosal layers during bolus transport. In addition, the information on pressure and the kinematics of the esophageal wall due to the coordination of muscle activation is provided, which may help relate clinical data from manometry and ultrasound images to the underlying esophageal motor function.
△ Less
Submitted 8 January, 2015;
originally announced January 2015.