-
Sensitivity and control of a 6-axis fused-silica seismometer
Authors:
Jiri Smetana,
Amit Singh Ubhi,
Emilia Chick,
Leonid Prokhorov,
John Bryant,
Artemiy Dmitriev,
Alex Gill,
Lari Koponen,
Haixing Miao,
Alan V. Cumming,
Giles Hammond,
Valery Frolov,
Richard Mittleman,
Peter Fritchel,
Denis Martynov
Abstract:
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band t…
▽ More
We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band towards mHz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (LIGO) in improving their observation capability of intermediate-mass black holes ($\sim 1000\,M_\odot$). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fibre, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.
△ Less
Submitted 6 January, 2025; v1 submitted 22 May, 2024;
originally announced May 2024.
-
An optically pumped magnetic gradiometer for the detection of human biomagnetism
Authors:
Harry Cook,
Yulia Bezsudnova,
Lari M. Koponen,
Ole Jensen,
Giovanni Barontini,
Anna U. Kowalczyk
Abstract:
We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode homogeneous magnetic field noise with up to 30 dB attenuation. We demonstrate that our magnetic field gradiometer is sufficiently sensitive and resilient to be…
▽ More
We realise an intrinsic optically pumped magnetic gradiometer based on non-linear magneto-optical rotation. We show that our sensor can reach a gradiometric sensitivity of 18 $\text{fT}/\text{cm}/\sqrt{\text{Hz}}$ and can reject common mode homogeneous magnetic field noise with up to 30 dB attenuation. We demonstrate that our magnetic field gradiometer is sufficiently sensitive and resilient to be employed in biomagnetic applications. In particular, we are able to record the auditory evoked response of the human brain, and to perform real-time magnetocardiography in the presence of external magnetic field disturbances. Our gradiometer provides complementary capabilities in human biomagnetic sensing to optically pumped magnetometers, and opens new avenues in the detection of human biomagnetism.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Double-containment coil with enhanced winding mounting for transcranial magnetic stimulation with reduced acoustic noise
Authors:
Lari M. Koponen,
Stefan M. Goetz,
Angel V. Peterchev
Abstract:
Objective: This work aims to reduce the acoustic noise level of transcranial magnetic stimulation (TMS) coils. TMS requires high currents (several thousand amperes) to be pulsed through the coil, which generates a loud acoustic impulse whose peak sound pressure level (SPL) can exceed 130 dB(Z). This sound poses a risk to hearing and elicits unwanted neural activation of auditory brain circuits. Me…
▽ More
Objective: This work aims to reduce the acoustic noise level of transcranial magnetic stimulation (TMS) coils. TMS requires high currents (several thousand amperes) to be pulsed through the coil, which generates a loud acoustic impulse whose peak sound pressure level (SPL) can exceed 130 dB(Z). This sound poses a risk to hearing and elicits unwanted neural activation of auditory brain circuits. Methods: We propose a new double-containment coil with enhanced winding mounting (DCC), which utilizes acoustic impedance mismatch to contain and dissipate the impulsive sound within an air-tight outer casing. The coil winding is potted in a rigid block, which is mounted to the outer casing by its acoustic nodes that are subject to minimum vibration during the pulse. The rest of the winding block is isolated from the casing by an air gap, and sound is absorbed by foam within the casing. The casing thickness under the winding center is minimized to maximize the coil electric field output. Results: Compared to commercial figure-of-eight TMS coils, the DCC prototype has 10-33 dB(Z) lower SPL at matched stimulation strength, whilst providing 22% higher maximum stimulation strength than equally focal commercial coils. Conclusion: The DCC design greatly reduces the acoustic noise of TMS while increasing the achievable stimulation strength. Significance: The acoustic noise reduction from our coil design is comparable to that provided by typical hearing protection devices. This coil design approach can enhance hearing safety and reduce auditory co-activations in the brain and other detrimental effects of TMS sound.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Ferromagnetic resonance in $ε$-Co magnetic composites
Authors:
Khattiya Chalapat,
Jaakko V. I. Timonen,
Maija Huuppola,
Lari Koponen,
Christoffer Johans,
Robin H. A. Ras,
Olli Ikkala,
Markku A. Oksanen,
Eira Seppälä,
G. S. Paraoanu
Abstract:
We investigate the electromagnetic properties of assemblies of nanoscale $ε$-cobalt crystals with size range between 5 nm to 35 nm, embedded in a polystyrene (PS) matrix, at microwave (1-12 GHz) frequencies. We investigate the samples by transmission electron microscopy (TEM) imaging, demonstrating that the particles aggregate and form chains and clusters. By using a broadband coaxial-line method,…
▽ More
We investigate the electromagnetic properties of assemblies of nanoscale $ε$-cobalt crystals with size range between 5 nm to 35 nm, embedded in a polystyrene (PS) matrix, at microwave (1-12 GHz) frequencies. We investigate the samples by transmission electron microscopy (TEM) imaging, demonstrating that the particles aggregate and form chains and clusters. By using a broadband coaxial-line method, we extract the magnetic permeability in the frequency range from 1 to 12 GHz, and we study the shift of the ferromagnetic resonance with respect to an externally applied magnetic field. We find that the zero-magnetic field ferromagnetic resonant peak shifts towards higher frequencies at finite magnetic fields, and the magnitude of complex permeability is reduced. At fields larger than 2.5 kOe the resonant frequency changes linearly with the applied magnetic field, demonstrating the transition to a state in which the nanoparticles become dynamically decoupled. In this regime, the particles inside clusters can be treated as non-interacting, and the peak position can be predicted from Kittel's ferromagnetic resonance theory for non-interacting uniaxial spherical particles combined with the Landau-Lifshitz-Gilbert (LLG) equation. In contrast, at low magnetic fields this magnetic order breaks down and the resonant frequency in zero magnetic field reaches a saturation value reflecting the interparticle interactions as resulting from aggregation. Our results show that the electromagnetic properties of these composite materials can be tuned by external magnetic fields and by changes in the aggregation structure.
△ Less
Submitted 6 November, 2014; v1 submitted 17 October, 2014;
originally announced October 2014.