Optimized detection modality for double resonance alignment based optical magnetometer
Authors:
A. Akbar,
M. Kozbiál,
L. Elson,
A. Meraki,
J. Kolodyński,
K. Jensen
Abstract:
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesiu…
▽ More
In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on multipole moments description. Experiments are carried out using a room-temperature paraffin-coated Caesium vapour cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization rotation detection mode yields larger signals and better sensitivity than absorption measurement of light.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
Spin noise spectroscopy of an alignment-based atomic magnetometer
Authors:
Marcin Kozbial,
Lucy Elson,
Lucas M. Rushton,
Ali Akbar,
Adil Meraki,
Kasper Jensen,
Jan Kolodynski
Abstract:
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pumping with circular or linear polarized light, r…
▽ More
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin-polarized through optical pumping with circular or linear polarized light, respectively. Characterisation of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarisation angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding line-widths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks.
△ Less
Submitted 30 July, 2024; v1 submitted 9 December, 2023;
originally announced December 2023.
-
Zero-field optical magnetometer based on spin-alignment
Authors:
Adil Meraki,
Lucy Elson,
Nok Ho,
Ali Akbar,
Marcin Koźbiał,
Jan Kołodyński,
Kasper Jensen
Abstract:
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-al…
▽ More
Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero-field. A novel approach is introduced, which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Fundamental limits in Bayesian thermometry and attainability via adaptive strategies
Authors:
Mohammad Mehboudi,
Mathias R. Jørgensen,
Stella Seah,
Jonatan B. Brask,
Jan Kołodyński,
Martí Perarnau-Llobet
Abstract:
We investigate the limits of thermometry using quantum probes at thermal equilibrium within the Bayesian approach. We consider the possibility of engineering interactions between the probes in order to enhance their sensitivity, as well as feedback during the measurement process, i.e., adaptive protocols. On the one hand, we obtain an ultimate bound on thermometry precision in the Bayesian setting…
▽ More
We investigate the limits of thermometry using quantum probes at thermal equilibrium within the Bayesian approach. We consider the possibility of engineering interactions between the probes in order to enhance their sensitivity, as well as feedback during the measurement process, i.e., adaptive protocols. On the one hand, we obtain an ultimate bound on thermometry precision in the Bayesian setting, valid for arbitrary interactions and measurement schemes, which lower bounds the error with a quadratic (Heisenberg-like) scaling with the number of probes. We develop a simple adaptive strategy that can saturate this limit. On the other hand, we derive a no-go theorem for non-adaptive protocols that does not allow for better than linear (shot-noise-like) scaling even if one has unlimited control over the probes, namely access to arbitrary many-body interactions.
△ Less
Submitted 2 April, 2022; v1 submitted 12 August, 2021;
originally announced August 2021.
-
Noisy atomic magnetometry in real time
Authors:
Julia Amoros-Binefa,
Jan Kolodynski
Abstract:
Continuously monitored atomic spin-ensembles allow, in principle, for real-time sensing of external magnetic fields beyond classical limits. Within the linear-Gaussian regime, thanks to the phenomenon of measurement-induced spin-squeezing, they attain a quantum-enhanced scaling of sensitivity both as a function of time, $t$, and the number of atoms involved, $N$. In our work, we rigorously study h…
▽ More
Continuously monitored atomic spin-ensembles allow, in principle, for real-time sensing of external magnetic fields beyond classical limits. Within the linear-Gaussian regime, thanks to the phenomenon of measurement-induced spin-squeezing, they attain a quantum-enhanced scaling of sensitivity both as a function of time, $t$, and the number of atoms involved, $N$. In our work, we rigorously study how such conclusions based on Kalman filtering methods change when inevitable imperfections are taken into account: in the form of collective noise, as well as stochastic fluctuations of the field in time. We prove that even an infinitesimal amount of noise disallows the error to be arbitrarily diminished by simply increasing $N$, and forces it to eventually follow a classical-like behaviour in $t$. However, we also demonstrate that, "thanks" to the presence of noise, in most regimes the model based on a homodyne-like continuous measurement actually achieves the ultimate sensitivity allowed by the decoherence, yielding then the optimal quantum-enhancement. We are able to do so by constructing a noise-induced lower bound on the error that stems from a general method of classically simulating a noisy quantum evolution, during which the stochastic parameter to be estimated -- here, the magnetic field -- is encoded. The method naturally extends to schemes beyond the linear-Gaussian regime, in particular, also to ones involving feedback or active control.
△ Less
Submitted 8 December, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Sub-Rayleigh resolution of two incoherent sources by array homodyning
Authors:
Chandan Datta,
Marcin Jarzyna,
Yink Loong Len,
Karol Łukanowski,
Jan Kołodyński,
Konrad Banaszek
Abstract:
Conventional incoherent imaging based on measuring the spatial intensity distribution in the image plane faces the resolution hurdle described by the Rayleigh diffraction criterion. Here, we demonstrate theoretically using the concept of the Fisher information that quadrature statistics measured by means of array homodyne detection enables estimation of the distance between two incoherent point so…
▽ More
Conventional incoherent imaging based on measuring the spatial intensity distribution in the image plane faces the resolution hurdle described by the Rayleigh diffraction criterion. Here, we demonstrate theoretically using the concept of the Fisher information that quadrature statistics measured by means of array homodyne detection enables estimation of the distance between two incoherent point sources well below the Rayleigh limit for sufficiently high signal-to-noise ratio. This capability is attributed to the availability of spatial coherence information between individual detector pixels acquired using the coherent detection technique. A simple analytical approximation for the precision attainable in the sub-Rayleigh region is presented. Furthermore, an estimation algorithm is proposed and applied to Monte Carlo simulated data.
△ Less
Submitted 27 November, 2020; v1 submitted 18 May, 2020;
originally announced May 2020.
-
Signal tracking beyond the time resolution of an atomic sensor by Kalman filtering
Authors:
Ricardo Jiménez-Martínez,
Jan Kolodynski,
Charikleia Troullinou,
Vito Giovanni Lucivero,
Jia Kong,
Morgan W. Mitchell
Abstract:
We study causal waveform estimation (tracking) of time-varying signals in a paradigmatic atomic sensor, an alkali vapor monitored by Faraday rotation probing. We use Kalman filtering, which optimally tracks known linear Gaussian stochastic processes, to estimate stochastic input signals that we generate by optical pumping. Comparing the known input to the estimates, we confirm the accuracy of the…
▽ More
We study causal waveform estimation (tracking) of time-varying signals in a paradigmatic atomic sensor, an alkali vapor monitored by Faraday rotation probing. We use Kalman filtering, which optimally tracks known linear Gaussian stochastic processes, to estimate stochastic input signals that we generate by optical pumping. Comparing the known input to the estimates, we confirm the accuracy of the atomic statistical model and the reliability of the Kalman filter, allowing recovery of waveform details far briefer than the sensor's intrinsic time resolution. With proper filter choice, we obtain similar benefits when tracking partially-known and non-Gaussian signal processes, as are found in most practical sensing applications. The method evades the trade-off between sensitivity and time resolution in coherent sensing.
△ Less
Submitted 21 February, 2018; v1 submitted 25 July, 2017;
originally announced July 2017.