From Single Particles to Clinical Beam Rates: A Wide Dynamic Range Beam Monitor
Authors:
Simon Waid,
Philipp Gaggl,
Andreas Gsponer,
Richard Thalmeier,
Jürgen Burin,
Matthias Knopf,
Thomas Bergauer
Abstract:
Access to high-energy particle beams is key for testing high-energy physics (HEP) instruments. Accelerators for cancer treatment can serve as such a testing ground. However, HEP instrument tests typically require particle fluxes significantly lower than for cancer treatment. Thus, facilities need adaptations to fulfill both the requirements for cancer treatment and the requirements for HEP instrum…
▽ More
Access to high-energy particle beams is key for testing high-energy physics (HEP) instruments. Accelerators for cancer treatment can serve as such a testing ground. However, HEP instrument tests typically require particle fluxes significantly lower than for cancer treatment. Thus, facilities need adaptations to fulfill both the requirements for cancer treatment and the requirements for HEP instrument testing. We report on the progress made in developing a beam monitor with a sufficient dynamic range to allow for the detection of single particles, while still being able to act as a monitor at the clinical particle rates of the MedAustron treatment facility. The beam monitor is designed for integration into existing accelerators.
△ Less
Submitted 24 April, 2025;
originally announced April 2025.
-
Exploring Offline Pileup Correction to Improve the Accuracy of Microdosimetric Characterization in Clinical Ion Beams
Authors:
Matthias Knopf,
Sandra Barna,
Daniel Radmanovac,
Thomas Bergauer,
Albert Hirtl,
Giulio Magrin
Abstract:
Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorp…
▽ More
Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorporates a charge-sensitive amplifier followed by a shaping network. At high particle rates, the pileup of multiple pulses leads to distortions in the recorded spectra. Especially for gas-based detectors, this is a significant issue, that can be reduced by using solid-state detectors with smaller cross-sectional areas and faster readout speeds. At particle rates typical for ion therapy, however, such devices will also experience pileup. Mitigation techniques often focus on avoiding pileup altogether, while post-processing approaches are rarely investigated. This work explores pileup effects in microdosimetric measurements and presents a stochastic resampling algorithm, allowing for offline simulation and correction of spectra. Initially it was developed for measuring neutron spectra with tissue equivalent proportional counters and is adapted for the use with solid-state microdosimeters in a clinical radiotherapy setting. The algorithm was tested on data acquired with solid-state microdosimeters at the MedAustron ion therapy facility. The successful simulation and reduction of pileup counts is achieved by establishing of a limited number of parameters for a given setup. The presented results illustrate the potential of offline correction methods in situations where a direct pileup-free measurement is currently not practicable.
△ Less
Submitted 15 April, 2025; v1 submitted 16 December, 2024;
originally announced December 2024.
-
Measurement of the electron-hole pair creation energy in a 4H-SiC p-n diode
Authors:
Andreas Gsponer,
Matthias Knopf,
Philipp Gaggl,
Jürgen Burin,
Simon Waid,
Thomas Bergauer
Abstract:
For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC a…
▽ More
For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $ε_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $ε_{\text{i}}$ using $50$ $μ$m 4H-SiC p-n diodes designed for particle detection in high-energy physics. The detector response was measured for $α$ particles between 4.2 MeV and 5.6 MeV for 4H-SiC and a silicon reference device. Different $α$ energies were obtained by using multiple nuclides and varying the effective air gap between the $α$ source and the detector. The energy deposited in the detectors was determined using a Monte Carlo simulation, taking into account the device cross-sections. A linear fit of the detector response to the deposited energy yields $ε_{\text{i}} = (7.83 \pm 0.02)\;\text{eV}$, which agrees well with the most recent literature. For the 4H-SiC detectors, a linewidth of 28 keV FWHM was achieved, corresponding to an energy resolution of 0.5\%.
△ Less
Submitted 1 April, 2024; v1 submitted 7 November, 2023;
originally announced November 2023.