-
Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target
Authors:
ArDM Collaboration,
J. Calvo,
C. Cantini,
M. Daniel,
U. Degunda,
S. Di Luise,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
B. Montes,
W. Mu,
M. Munoz,
S. Murphy,
G. Natterer,
K. Nguyen,
K. Nikolics,
L. Periale,
C. Regenfus,
L. Romero,
A. Rubbia,
R. Santorelli,
F. Sergiampietri,
D. Sgalaberna,
T. Viant
, et al. (1 additional authors not shown)
Abstract:
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and s…
▽ More
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and safety approval until the recent filling of the target vessel with almost 2 ton of liquid argon. This report describes the experimental achievements during commissioning of ArDM and the transition into a stage of first physics data taking in single phase operational mode. We present preliminary observations from this run. A first indication for the background discrimination power of LAr detectors at the ton-scale is shown. We present an outlook for completing the detector with the electric drift field and upgrade of the scintillation light readout system with novel detector modules based on SiPMs in order to improve the light yield.
△ Less
Submitted 10 May, 2015;
originally announced May 2015.
-
ArDM: first results from underground commissioning
Authors:
A. Badertscher,
F. Bay,
N. Bourgeois,
C. Cantini,
A. Curioni,
M. Daniel,
U. Degunda,
S. Di Luise,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
D. Lussi,
G. Maire,
B. Montes,
S. Murphy,
G. Natterer,
K. Nikolics,
K. Nguyen,
L. Periale,
S. Ravat,
F. Resnati,
L. Romero,
A. Rubbia,
R. Santorelli
, et al. (4 additional authors not shown)
Abstract:
The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently install…
▽ More
The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to discriminate the background (electron recoils) from the WIMP signals (nuclear recoils). After a successful operation on surface at CERN, the detector was recently installed in the underground Laboratorio Subterráneo de Canfranc, and the commissioning phase is ongoing. We describe the status of the installation and present first results from data collected underground with the detector filled with gas argon at room temperature.
△ Less
Submitted 16 September, 2013;
originally announced September 2013.
-
Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment
Authors:
ArDM Collaboration,
A. Badertscher,
F. Bay,
N. Bourgeois,
C. Cantini,
M. Daniel,
U. Degunda,
S. DiLuise,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
D. Lussi,
G. Maire,
B. Montes,
S. Murphy,
G. Natterer,
K. Nikolics,
K. Nguyen,
L. Periale,
S. Ravat,
F. Resnati,
L. Romero,
A. Rubbia,
R. Santorelli
, et al. (4 additional authors not shown)
Abstract:
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper,…
▽ More
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.
△ Less
Submitted 29 June, 2013;
originally announced July 2013.
-
First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout
Authors:
A. Badertscher,
A. Curioni,
U. Degunda,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
D. Lussi G. Natterer,
K. Nguyen,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogen…
▽ More
In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge readout channels. The acquisition system, as well as the design and the performance of custom-made charge sensitive preamplifiers, are described. The complete experimental setup has been operated for a first time during a period of four weeks at CERN in the cryostat of the ArDM experiment, which was equipped with liquid and gas argon purification systems. The detector, exposed to cosmic rays, recorded events with a single-channel signal-to-noise ratio in excess of 30 for minimum ionising particles. Cosmic muon tracks and their $δ$-rays were used to assess the performance of the detector, and to estimate the liquid argon purity and the gain at different amplification fields.
△ Less
Submitted 21 January, 2013;
originally announced January 2013.
-
Performance of a 250L liquid Argon TPC for sub-GeV charged particle identification
Authors:
J-PARC T32 collaboration,
:,
O. Araoka,
A. Badertscher,
A. Curioni,
S. Di Luise,
U. Degunda,
L. Epprecht,
L. Esposito,
A. Gendotti,
T. Hasegawa,
S. Horikawa,
K. Kasami,
N. Kimura,
L. Knecht,
T. Kobayashi,
C. Lazzaro,
D. Lussi,
M. Maki,
A. Marchionni,
T. Maruyama,
A. Meregaglia,
T. Mitani,
Y. Nagasaka,
J. Naganoma
, et al. (17 additional authors not shown)
Abstract:
We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.
We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.
△ Less
Submitted 8 June, 2012; v1 submitted 6 June, 2012;
originally announced June 2012.
-
First operation and drift field performance of a large area double phase LAr Electron Multiplier Time Projection Chamber with an immersed Greinacher high-voltage multiplier
Authors:
A. Badertscher,
A. Curioni,
U. Degunda,
L. Epprecht,
A. Gendotti,
S. Horikawa,
L. Knecht,
D. Lussi,
A. Marchionni,
G. Natterer,
K. Nguyen,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
We have operated a liquid-argon large-electron-multiplier time-projection chamber (LAr LEM-TPC) with a large active area of 76 $\times$ 40 cm$^2$ and a drift length of 60 cm. This setup represents the largest chamber ever achieved with this novel detector concept. The chamber is equipped with an immersed built-in cryogenic Greinacher multi-stage high-voltage (HV) multiplier, which, when subjected…
▽ More
We have operated a liquid-argon large-electron-multiplier time-projection chamber (LAr LEM-TPC) with a large active area of 76 $\times$ 40 cm$^2$ and a drift length of 60 cm. This setup represents the largest chamber ever achieved with this novel detector concept. The chamber is equipped with an immersed built-in cryogenic Greinacher multi-stage high-voltage (HV) multiplier, which, when subjected to an external AC HV of $\sim$1 kV$_{\mathrm{pp}}$, statically charges up to a voltage a factor of $\sim$30 higher inside the LAr vessel, creating a uniform drift field of $\sim$0.5 kV/cm over the full drift length. This large LAr LEM-TPC was brought into successful operation in the double-phase (liquid-vapor) operation mode and tested during a period of $\sim$1 month, recording impressive three-dimensional images of very high-quality from cosmic particles traversing or interacting in the sensitive volume. The double phase readout and HV systems achieved stable operation in cryogenic conditions demonstrating their good characteristics, which particularly suit applications for next-generation giant-scale LAr-TPCs.
△ Less
Submitted 12 July, 2012; v1 submitted 16 April, 2012;
originally announced April 2012.
-
A tagged low-momentum kaon test-beam exposure with a 250L LAr TPC (J-PARC T32)
Authors:
O. Araoka,
A. Badertscher,
A. Curioni,
S. DiLuise,
U. Degunda,
L. Epprecht,
L. Esposito,
A. Gendotti,
T. Hasegawa,
S. Horikawa,
K. Kasami,
N. Kimura,
L. Knecht,
T. Kobayashi,
C. Lazzaro,
D. Lussi,
M. Maki,
A. Marchionni,
T. Maruyama,
A. Meregaglia,
T. Mitani,
Y. Nagasaka,
J. Naganoma,
H. Naito,
S. Narita
, et al. (13 additional authors not shown)
Abstract:
At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the neutrino sector and to search for nucleon decay. As a first step we proposed a test experiment to identify and measure charged kaons, including their decays, in liqui…
▽ More
At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the neutrino sector and to search for nucleon decay. As a first step we proposed a test experiment to identify and measure charged kaons, including their decays, in liquid argon. The detector, a 250L LAr TPC, is exposed to charged kaons, in a momentum range of 540-800 MeV/c, in the K1.1BR beamline of the J-PARC slow extraction facility. This is especially important to estimate efficiency and background for nucleon decay searches in the charged kaon mode ($p \rightarrow \barν K^+$, etc.), where the kaon momentum is expected to be in the few hundred MeV/c range. A prototype setup has been exposed in the K1.1BR beamline in the fall of 2010. This paper describes the capabilities of the beamline, the construction and setting up of the detector prototype, along with some preliminary results.
△ Less
Submitted 29 May, 2011;
originally announced May 2011.
-
ArDM: a ton-scale LAr detector for direct Dark Matter searches
Authors:
ArDM Collaboration,
A. Marchionni,
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
J. Coleman,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
K. Mavrokoridis,
A. Melgarejo
, et al. (19 additional authors not shown)
Abstract:
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduc…
▽ More
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr with a charge imaging detector. The ionization charge is extracted from the liquid into the gas phase and there amplified by the use of a Large Electron Multiplier in order to reduce the detection threshold. Direct detection of the ionization charge with fine spatial granularity, combined with a measurement of the amplitude and time evolution of the associated primary scintillation light, provide powerful tools for the identification of WIMP interactions against the background due to electrons, photons and possibly neutrons if scattering more than once. A one ton LAr detector is presently installed on surface at CERN to fully test all functionalities and it will be soon moved to an underground location. We will emphasize here the lessons learned from such a device for the design of a large LAr TPC for neutrino oscillation, proton decay and astrophysical neutrinos searches.
△ Less
Submitted 29 December, 2010;
originally announced December 2010.
-
First operation of a double phase LAr Large Electron Multiplier Time Projection Chamber with a two-dimensional projective readout anode
Authors:
A. Badertscher,
A. Curioni,
L. Knecht,
D. Lussi,
A. Marchionni,
G. Natterer,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of adjustable charge amplification, a promising readout technology for next-generation neutrino detectors and direct Dark Matter searches. In this…
▽ More
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of adjustable charge amplification, a promising readout technology for next-generation neutrino detectors and direct Dark Matter searches. In this paper, we report on the first operation of a LAr LEM-TPC prototype - with an active area of 10$\times$10 cm$^2$ and 21 cm drift length - equipped with a single 1 mm thick LEM amplifying stage and a two dimensional projective readout anode. Cosmic muon events were collected, fully reconstructed and used to characterize the performance of the chamber. The obtained signals provide images of very high quality and the energy loss distributions of minimum ionizing tracks give a direct estimate of the amplification. We find that a stable gain of 27 can be achieved with this detector configuration corresponding to a signal-over-noise ratio larger than 200 for minimum ionizing tracks. The decoupling of the amplification stage and the use of the 2D readout anode offer several advantages which are described in the text.
△ Less
Submitted 2 December, 2010;
originally announced December 2010.
-
Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
G. Natterer,
A. Rubbia,
Th. Strauss
Abstract:
Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical curren…
▽ More
Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical current $I_c$ of HTS cables in an external magnetic field was measured at liquid nitrogen and liquid argon temperatures and a small prototype HTS solenoid was built and tested.
△ Less
Submitted 27 October, 2010;
originally announced October 2010.
-
Stable operation with gain of a double phase Liquid Argon LEM-TPC with a 1 mm thick segmented LEM
Authors:
A. Badertscher,
A. Curioni,
S. Horikawa,
L. Knecht,
D. Lussi,
A. Marchionni,
G. Natterer,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for next-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3~lt chamber equipped with a 10$\times$10~cm$^2$ readout,…
▽ More
In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for next-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3~lt chamber equipped with a 10$\times$10~cm$^2$ readout, cosmic muon data was recorded during three weeks of data taking. A maximum gain of 6.5 was achieved and the liquid argon was kept pure enough to ensure 20~cm drift (O(ppb)~O$_2$ equivalent).
△ Less
Submitted 12 October, 2010;
originally announced October 2010.
-
Towards a liquid Argon TPC without evacuation: filling of a 6 m^3 vessel with argon gas from air to ppm impurities concentration through flushing
Authors:
A. Curioni,
L. Epprecht,
A. Gendotti,
L. Knecht,
D. Lussi,
A. Marchionni,
G. Natterer,
F. Resnati,
A. Rubbia,
J. Coleman,
M. Lewis,
K. Mavrokoridis,
K. McCormick,
C. Touramanis
Abstract:
In this paper we present a successful experimental test of filling a volume of 6 m$^3$ with argon gas, starting from normal ambient air and reducing the impurities content down to few parts per million (ppm) oxygen equivalent. This level of contamination was directly monitored measuring the slow component of the scintillation light of the Ar gas, which is sensitive to {\it all} sources of impuriti…
▽ More
In this paper we present a successful experimental test of filling a volume of 6 m$^3$ with argon gas, starting from normal ambient air and reducing the impurities content down to few parts per million (ppm) oxygen equivalent. This level of contamination was directly monitored measuring the slow component of the scintillation light of the Ar gas, which is sensitive to {\it all} sources of impurities affecting directly the argon scintillation.
△ Less
Submitted 22 September, 2010; v1 submitted 21 September, 2010;
originally announced September 2010.
-
First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches
Authors:
C. Amsler,
A. Badertscher,
V. Boccone,
A. Bueno,
M. C. Carmona-Benitez,
W. Creus,
A. Curioni,
M. Daniel,
E. J. Dawe,
U. Degunda,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
P. K. Lightfoot,
D. Lussi,
J. Lozano,
A. Marchionni,
K. Mavrokoridis,
A. Melgarejo,
P. Mijakowski,
G. Natterer
, et al. (16 additional authors not shown)
Abstract:
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM…
▽ More
ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
△ Less
Submitted 27 October, 2010; v1 submitted 19 September, 2010;
originally announced September 2010.
-
The ArDM experiment
Authors:
ArDM Collaboration,
C. Amsler,
A. Badertscher,
V. Boccone,
N. Bourgeois,
A. Bueno,
M. C. Carmona-Benitez,
M. Chorowski,
W. Creus,
A. Curioni,
E. Daw,
U. Degunda,
A. Dell'Antone,
M. Droge,
L. Epprecht,
C. Haller,
M. Haranczyk,
S. Horikawa,
L. Kaufmann,
J. Kisiel,
L. Knecht,
M. Laffranchi,
J. Lagoda,
C. Lazzaro,
P. Lightfoot
, et al. (29 additional authors not shown)
Abstract:
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin…
▽ More
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
△ Less
Submitted 28 June, 2010;
originally announced June 2010.
-
Giant Liquid Argon Observatory for Proton Decay, Neutrino Astrophysics and CP-violation in the Lepton Sector (GLACIER)
Authors:
A. Badertscher,
A. Curioni,
U. Degunda,
L. Epprecht,
S. Horikawa,
L. Knecht,
C. Lazzaro,
D. Lussi,
A. Marchionni,
G. Natterer,
P. Otiougova,
F. Resnati,
A. Rubbia,
C. Strabel,
J. Ulbricht,
T. Viant
Abstract:
GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) is a large underground observatory for proton decay search, neutrino astrophysics and CP-violation studies in the lepton sector. Possible underground sites are studied within the FP7 LAGUNA project (Europe) and along the JPARC neutrino beam in collaboration with KEK (Japan). The concept is scalable to very large masses.
GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) is a large underground observatory for proton decay search, neutrino astrophysics and CP-violation studies in the lepton sector. Possible underground sites are studied within the FP7 LAGUNA project (Europe) and along the JPARC neutrino beam in collaboration with KEK (Japan). The concept is scalable to very large masses.
△ Less
Submitted 30 December, 2009;
originally announced January 2010.
-
Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
D. Lussi,
A. Marchionni,
G. Natterer,
P. Otiougova,
F. Resnati,
A. Rubbia,
T. Viant
Abstract:
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM w…
▽ More
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.
△ Less
Submitted 16 July, 2009;
originally announced July 2009.
-
Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector
Authors:
The ArDM Collaboration,
V. Boccone,
P. K. Lightfoot,
K. Mavrokoridis,
C. Regenfus,
C. Amsler,
A. Badertscher,
A. Bueno,
H. Cabrera,
M. C. Carmona-Benitez,
M. Daniel,
E. J. Daw,
U. Degunda,
A. Dell'Antone,
A. Gendotti,
L. Epprecht,
S. Horikawa,
L. Kaufmann,
L. Knecht,
M. Laffranchi,
C. Lazzaro,
D. Lussi,
J. Lozano,
A. Marchionni,
A. Melgarejo
, et al. (16 additional authors not shown)
Abstract:
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were…
▽ More
To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
Construction and operation of a Double Phase LAr Large Electron Multiplier Time Projection Chamber
Authors:
A. Badertscher,
L. Knecht,
M. Laffranchi,
A. Marchionni,
G. Natterer,
P. Otiougova,
F. Resnati,
A. Rubbia
Abstract:
We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where cha…
▽ More
We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where charge amplification occurs. Each LEM is a thick macroscopic hole multiplier of 10x10 cm$^2$ manufactured with standard PCB techniques. The electrons signal is readout via two orthogonal coordinates, one using the induced signal on the segmented upper electrode of the LEM itself and the other by collecting the electrons on a segmented anode. Custom-made preamplifiers have been especially developed for this purpose. Cosmic ray tracks have been successfully observed in pure gas at room temperature and in double phase Ar operation. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.
△ Less
Submitted 20 November, 2008;
originally announced November 2008.