-
Thermalization of a SQUID chip at cryogenic temperature: Thermal conductance measurement for GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement between 20 and 200 mK
Authors:
M. D'Andrea,
G. Torrioli,
C. Macculi,
M. Kiviranta
Abstract:
In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have be…
▽ More
In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have been repeated in subsequent cryostat runs, to highlight degradation effects due to thermal cycles. Here, we present the results obtained by glues and greases widely used in cryogenic environments, i.e. GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
Frequency domain multiplexing readout for large arrays of transition-edge sensors
Authors:
Davide Vaccaro,
Hiroki Akamatsu,
Luciano Gottardi,
Jan van der Kuur,
Kenichiro Nagayoshi,
Emanuele Taralli,
Martin de Wit,
Marcel P. Bruijn,
Anton J. van der Linden,
Bert-Joost van Leeuwen,
Paul van der Hulst,
Kevin Ravensberg,
Cor P. de Vries,
Mikko Kiviranta,
Jian-Rong Gao,
Jan-Willem A. den Herder
Abstract:
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-s…
▽ More
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-stage SQUID amplifiers from VTT Finland, we demonstrated feasibility of our FDM readout technology, with the simultaneous readout of 37 pixels with an energy resolution at of 2.23 eV at an energy of 6 keV. We finally outline our plans for further scaling up and improving our technology.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers
Authors:
H. Akamatsu,
D. Vaccaro,
L. Gottardi,
J. van der Kuur,
C. P. de Vries,
M. Kiviranta,
K. Ravensberg,
M. D'Andrea,
E. Taralli,
M. de Wit,
M. P. Bruijn,
P. van der Hulst,
R. H. den Hartog,
B-J. van Leeuwen,
A. J. van der Linden,
A. J McCalden,
K. Nagayoshi,
A. C. T. Nieuwenhuizen,
M. L. Ridder,
S. Visser,
P. van Winden,
J. R. Gao,
R. W. M. Hoogeveen,
B. D. Jackson,
J-W. A. den Herder
Abstract:
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum inte…
▽ More
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed X-ray spectral resolutions $@$ 5.9 keV are $ΔE_{\rm 31 pix ~MUX}=2.14\pm0.03$ eV and $ΔE_{\rm 37 pix ~MUX}=2.23\pm0.03$ eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution and to increase the number of multiplexed TESs, and to open up applications for TES X-ray microcalorimeters.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
A test platform for the detection and readout chain for the Athena X-IFU
Authors:
Gabriele Betancourt-Martinez,
François Pajot,
Sophie Beaumont,
Gilles Roudil,
Joseph Adams,
Hiroki Akamatsu,
Simon Bandler,
Bernard Bertrand,
Marcel Bruijn,
Florent Castellani,
Edoardo Cucchetti,
William Doriese,
Michel Dupieux,
Hervé Geoffray,
Luciano Gottardi,
Brian Jackson,
Jan van der Kuur,
Mikko Kiviranta,
Antoine Miniussi,
Phillipe Peille,
Kevin Ravensberg,
Laurent Ravera,
Carl Reintsema,
Kazuhiro Sakai,
Stephen Smith
, et al. (4 additional authors not shown)
Abstract:
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of th…
▽ More
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout, and will evolve over time to become more representative of the X-IFU mission baseline. The test bench yields critical feedback on subsystem designs and interfaces, in particular the warm readout electronics, and will provide an in-house detection system for continued testing and development of the warm readout electronics and for the validation of X-ray calibration sources. In this paper, we describe the test bench subsystems and design, characterization of the cryostat, and current status of the project.
△ Less
Submitted 7 July, 2021;
originally announced July 2021.
-
Josephson dynamical simulation using the electronic circuit simulator APLAC: a tutorial
Authors:
Mikko Kiviranta
Abstract:
Analysis Program for Linear Active Circuits (APLAC) is a general-purpose electronics circuit simulator, which has included a built-in model of the Josephson junction (JJ) since late 80's. It capabilities in simulating eg. noisy Superconducting Quantum Interference Devices (SQUIDs), Rapid Single Flux Quantum (RSFQ) logic circuits, or Superconducting Transition Edge Sensors (TESes) are relatively un…
▽ More
Analysis Program for Linear Active Circuits (APLAC) is a general-purpose electronics circuit simulator, which has included a built-in model of the Josephson junction (JJ) since late 80's. It capabilities in simulating eg. noisy Superconducting Quantum Interference Devices (SQUIDs), Rapid Single Flux Quantum (RSFQ) logic circuits, or Superconducting Transition Edge Sensors (TESes) are relatively unknown within the superconducting electronics community. Here we give a brief step-to-step tutorial for APLAC users to unleash those capabilities.
△ Less
Submitted 21 March, 2021;
originally announced March 2021.
-
Two-stage SQUID amplifier with bias current re-use
Authors:
Mikko Kiviranta
Abstract:
We have designed and fabricated an integrated two-stage SQUID amplifier, requiring only one bias line and one flux setpoint line. From the biasing viewpoint the two stages are connected in series while from the signal propagation viewpoint the stages are cascaded. A proof-of principle demonstration at T = 4.2 K is presented.
We have designed and fabricated an integrated two-stage SQUID amplifier, requiring only one bias line and one flux setpoint line. From the biasing viewpoint the two stages are connected in series while from the signal propagation viewpoint the stages are cascaded. A proof-of principle demonstration at T = 4.2 K is presented.
△ Less
Submitted 30 December, 2020;
originally announced December 2020.
-
Class-B cable-driving SQUID amplifier
Authors:
Mikko Kiviranta
Abstract:
We suggest a SQUID amplifier configuration with improved power efficiency, for applications where cooling budgets are limited, in particular superconducting detector array readouts in space observatories. The suggested two-SQUID configuration keeps one SQUID in a zero-voltage state during a half-cycle of the input while the other SQUID generates voltage. For the other half-cycle the roles of the S…
▽ More
We suggest a SQUID amplifier configuration with improved power efficiency, for applications where cooling budgets are limited, in particular superconducting detector array readouts in space observatories. The suggested two-SQUID configuration keeps one SQUID in a zero-voltage state during a half-cycle of the input while the other SQUID generates voltage. For the other half-cycle the roles of the SQUIDs are reversed. The circuit is an electrostatic dual of a transistor-based amplifier operating in class-B. A proof-of principle demonstration at T = 4.2 K is presented.
△ Less
Submitted 27 November, 2020; v1 submitted 23 November, 2020;
originally announced November 2020.
-
Magnetic field sensing with the kinetic inductance of a high-$T_\mathrm{c}$ superconductor
Authors:
V. Vesterinen,
S. Ruffieux,
A. Kalabukhov,
H. Sipola,
M. Kiviranta,
D. Winkler,
J. F. Schneiderman,
J. Hassel
Abstract:
We carry out an experimental feasibility study of a magnetic field sensor based on the kinetic inductance of the high-$T_\mathrm{c}$ superconductor yttrium barium copper oxide. We pattern thin superconducting films into radio-frequency resonators that feature a magnetic field pick-up loop. At 77 K and for film thicknesses down to 75 nm, we observe the persistence of screening currents that modulat…
▽ More
We carry out an experimental feasibility study of a magnetic field sensor based on the kinetic inductance of the high-$T_\mathrm{c}$ superconductor yttrium barium copper oxide. We pattern thin superconducting films into radio-frequency resonators that feature a magnetic field pick-up loop. At 77 K and for film thicknesses down to 75 nm, we observe the persistence of screening currents that modulate the loop kinetic inductance. According to the experimental results the device concept appears attractive for sensing applications in ambient magnetic field environments. We report on a device with a magnetic field sensitivity of 4 pT/Hz${}^{1/2}$, an instantaneous dynamic range of 11 $μ$T, and operability in magnetic fields up to 28 $μ$T.
△ Less
Submitted 30 October, 2018;
originally announced October 2018.
-
Two SQUID amplifiers intended to alleviate the summing node inductance problem in multiplexed arrays of Transition Edge Sensors
Authors:
Mikko Kiviranta,
Leif Grönberg,
Jan van der Kuur
Abstract:
Frequency Domain Multiplexed detector arrays constructed of superconducting Transition Edge Sensors in the current-summing configuration suffer from the finite impedance of the summing node which should ideally be zero. We suggest two circuits to alleviate the effect. The first circuit uses a capacitive resonant transformer to increase the voltages and decrease the currents of TES signals to overc…
▽ More
Frequency Domain Multiplexed detector arrays constructed of superconducting Transition Edge Sensors in the current-summing configuration suffer from the finite impedance of the summing node which should ideally be zero. We suggest two circuits to alleviate the effect. The first circuit uses a capacitive resonant transformer to increase the voltages and decrease the currents of TES signals to overcome the parasitic inductance of the interconnections. On the SQUID chip impedance transform to the opposite direction takes place. The second circuit implements a power combiner having a better branch-to-branch isolation than a simple T-junction. Two SQUID devices have been designed and fabricated for a proof-of-principle demonstration of the circuits.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Low-dissipating push-pull SQUID amplifier for TES detector readout
Authors:
Mikko Kiviranta
Abstract:
We suggest SQUID amplifier configuration intended for millikelvin refrigerators where cooling power is limited and hence high power efficiency is desirable. The configuration operates the SQUIDs in class-AB rather than the traditional class-A. A proof-of principle demonstration at T = 4.2 K is presented.
We suggest SQUID amplifier configuration intended for millikelvin refrigerators where cooling power is limited and hence high power efficiency is desirable. The configuration operates the SQUIDs in class-AB rather than the traditional class-A. A proof-of principle demonstration at T = 4.2 K is presented.
△ Less
Submitted 10 October, 2018;
originally announced October 2018.
-
Side-wall spacer passivated sub-um Josephson junction fabrication process
Authors:
Leif Grönberg,
Mikko Kiviranta,
Visa Vesterinen,
Janne Lehtinen,
Slawomir Simbierowicz,
Juho Luomahaara,
Mika Prunnila,
Juha Hassel
Abstract:
We present a structure and a fabrication method for superconducting tunnel junctions down to the dimensions of 200 nm using i-line UV lithography. The key element is a side-wall-passivating spacer structure (SWAPS) which is shaped for smooth crossline contacting and low parasitic capacitance. The SWAPS structure enables formation of junctions with dimensions at or below the lithography-limited lin…
▽ More
We present a structure and a fabrication method for superconducting tunnel junctions down to the dimensions of 200 nm using i-line UV lithography. The key element is a side-wall-passivating spacer structure (SWAPS) which is shaped for smooth crossline contacting and low parasitic capacitance. The SWAPS structure enables formation of junctions with dimensions at or below the lithography-limited linewidth. An additional benefit is avoiding the excessive use of amorphous dielectric materials which is favorable in sub-Kelvin microwave applications often plagued by nonlinear and lossy dielectrics. We apply the structure to niobium trilayer junctions, and provide characterization results yielding evidence on wafer-scale scalability, and critical current density tuning in the range of 0.1 -- 3.0 kA/cm$^2$. We discuss the applicability of the junction process in the context of different applications, such as, SQUID magnetometers and Josephson parametric amplifiers.
△ Less
Submitted 9 March, 2018; v1 submitted 20 June, 2017;
originally announced June 2017.
-
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
Authors:
J. van der Kuur,
L. G. Gottardi,
H. Akamatsu,
B. J. van Leeuwen,
R. den Hartog,
D. Haas,
M. Kiviranta,
B. J. Jackson
Abstract:
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 38…
▽ More
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based on a large cryogenic imaging array of Transition Edge Sensors (TES) based microcalorimeters operating at a temperature of 100mK. The imaging array consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a field of view with a diameter of of 5 arc minutes. Multiplexed readout of the cryogenic microcalorimeter array is essential to comply with the cooling power and complexity constraints on a space craft. Frequency domain multiplexing has been under development for the readout of TES-based detectors for this purpose, not only for the X-IFU detector arrays but also for TES-based bolometer arrays for the Safari instrument of the Japanese SPICA observatory. This paper discusses the design considerations which are applicable to optimise the multiplex factor within the boundary conditions as set by the space craft. More specifically, the interplay between the science requirements such as pixel dynamic range, pixel speed, and cross talk, and the space craft requirements such as the power dissipation budget, available bandwidth, and electromagnetic compatibility will be discussed.
△ Less
Submitted 16 November, 2016;
originally announced November 2016.
-
Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Marcel P. Bruijn,
Roland den Hartog,
Jan-Willem den Herder,
Brian Jackson,
Mikko Kiviranta,
Jan van der Kuur,
Henk van Weers
Abstract:
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on…
▽ More
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.
△ Less
Submitted 3 April, 2016;
originally announced April 2016.
-
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Authors:
Luciano Gottardi,
Hiroki Akamatsu,
Didier Barret,
Marcel P. Bruijn,
Roland H. den Hartog,
Jan-Willem den Herder,
Henk F. C. Hoevers,
Mikko Kiviranta,
Jan van der Kuur,
Anton J. van der Linden,
Brian D. Jackson,
Madu Jambunathan,
Marcel L. Ridder
Abstract:
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with diff…
▽ More
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
△ Less
Submitted 2 April, 2016;
originally announced April 2016.
-
Multiplexed readout demonstration of a TES-based detector array in a resistance locked loop
Authors:
Jan van der Kuur,
Luciano Gottardi,
Mikko Kiviranta,
Hiroki Akamatsu,
Pourya Khosropanah,
Roland den Hartog,
Toyoaki Suzuki,
Brian Jackson
Abstract:
TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the instruments. In an effort to improve the properties of TES-based detectors, fixing the TES resistance in a resistance-locked loop (RLL) under optical loading ha…
▽ More
TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the instruments. In an effort to improve the properties of TES-based detectors, fixing the TES resistance in a resistance-locked loop (RLL) under optical loading has recently been proposed. Earlier theoretical work on this mode of operation has shown that the detector speed, linearity and dynamic range should improve with respect to voltage biased operation.
This paper presents an experimental demonstration of multiplexed readout in this mode of operation in a TES-based detector array with noise equivalent power values (NEP) of $3.5\cdot 10^{-19} $W/$\sqrt{\mathrm{Hz}}$. The measured noise and dynamic properties of the detector in the RLL will be compared with the earlier modelling work. Furthermore, the practical implementation routes for future FDM systems for the readout of bolometer and microcalorimeter arrays will be discussed.
△ Less
Submitted 19 January, 2015;
originally announced January 2015.
-
Operation of transition edge sensors in a resistance locked loop
Authors:
Jan van der Kuur,
Mikko Kiviranta
Abstract:
We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal power. By combining a large negative electrothermal feedback with a load independent resistance, this approach can significantly linearise the response of the de…
▽ More
We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal power. By combining a large negative electrothermal feedback with a load independent resistance, this approach can significantly linearise the response of the detector in the large signal limit. The electrothermal feedback is enhanced in comparison with the commonly applied voltage biasing, which further increases the speed of the detector. Furthermore, in frequency domain multiplexed (FDM) readout, the sinusoidal bias voltages for each TES can be generated cryogenically with the readout SQUIDs.
△ Less
Submitted 24 November, 2012;
originally announced November 2012.