-
A Sub-5mW Evanescent Field Atom Guide with Nanofibers towards Guided Atom Interferometry with Membrane Waveguides
Authors:
Adrian Orozco,
William Kindel,
Nicholas Karl,
Yuan-Yu Jau,
Michael Gehl,
Grant Biedermann,
Jongmin Lee
Abstract:
Great progress has been made in the field of quantum inertial sensors, from the laboratory to the real-world use, which will ultimately require sensor miniaturization and ruggedization for dynamic motion. However, lateral atomic movement with respect to the sensing axis limits inertial sensing, which inspires the atom guides to ensure transverse atomic confinement. Compared to a relatively large f…
▽ More
Great progress has been made in the field of quantum inertial sensors, from the laboratory to the real-world use, which will ultimately require sensor miniaturization and ruggedization for dynamic motion. However, lateral atomic movement with respect to the sensing axis limits inertial sensing, which inspires the atom guides to ensure transverse atomic confinement. Compared to a relatively large free-space optical mode, an evanescent field (EF) mode with an advantageously small mode area allows for stronger atom-light interactions and lower optical power requirements for the atom guides. We study EF atom guides in nanofibers and waveguides with traveling evanescent waves, rather than EF optical lattices with standing evanescent waves. Our preliminary demonstration of an EF atom guide takes place on a nanofiber using 685 nm and 937 nm lights, and we experimentally show that the atomic coherence of the EF atom guide (685/937 nm) is similar to the EF optical lattice. By replacing the 685 nm light with 793 nm light, we further demonstrate the sub-5mW EF atom guide (793/937 nm) on nanofibers and assess relative power reduction of 61$\%$ on nanofibers and 78$\%$ on membrane waveguides, compared to nanofibers (685/937 nm), for the same optical potential depth. Power reduction is beneficial for reducing total optical power requirements and improving heat dissipation in vacuum for atom guiding on chip-based membrane-photonic devices. To connect this work with EF-guided atom interferometry, we evaluate the viability and potential benefits of using the low-power light configuration on membrane waveguides, presenting fabricated linear and circular waveguides for future demonstrations. This is a promising step towards a chip-scale quantum inertial sensor array with reduced size, weight, and power.
△ Less
Submitted 12 November, 2023;
originally announced November 2023.
-
A Compact Cold-Atom Interferometer with a High Data-Rate Grating Magneto-Optical Trap and a Photonic-Integrated-Circuit-Compatible Laser System
Authors:
Jongmin Lee,
Roger Ding,
Justin Christensen,
Randy R. Rosenthal,
Aaron Ison,
Daniel Paul Gillund,
David Bossert,
Kyle H. Fuerschbach,
William Kindel,
Patrick S. Finnegan,
Joel R. Wendt,
Michael Gehl,
Ashok Kodigala,
Hayden McGuinness,
Charles A. Walker,
Shanalyn A. Kemme,
Anthony Lentine,
Grant Biedermann,
Peter D. D. Schwindt
Abstract:
The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tet…
▽ More
The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 uK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0 - 4.5 ms interrogation time, resulting in $Δ$ g / g = 2.0e-6. This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
△ Less
Submitted 1 September, 2022; v1 submitted 10 July, 2021;
originally announced July 2021.
-
Characterization of Suspended Membrane Waveguides towards a Photonic Atom Trap Integrated Platform
Authors:
Michael Gehl,
William Kindel,
Nicholas Karl,
Adrian Orozco,
Katherine Musick,
Douglas Trotter,
Christina Dallo,
Andrew Starbuck,
Andrew Leenheer,
Christopher DeRose,
Grant Biedermann,
Yuan-Yu Jau,
Jongmin Lee
Abstract:
We demonstrate an optical waveguide device, capable of supporting the high, in-vacuum, optical power necessary for trapping a single atom or a cold atom ensemble with evanescent fields. Our photonic integrated platforms, with suspended membrane waveguides, successfully manages optical powers of 6 mW (500 um span) to nearly 30 mW (125 um span) over an un-tethered waveguide span. This platform is co…
▽ More
We demonstrate an optical waveguide device, capable of supporting the high, in-vacuum, optical power necessary for trapping a single atom or a cold atom ensemble with evanescent fields. Our photonic integrated platforms, with suspended membrane waveguides, successfully manages optical powers of 6 mW (500 um span) to nearly 30 mW (125 um span) over an un-tethered waveguide span. This platform is compatible with laser cooling and magneto-optical traps (MOTs) in the vicinity of the suspended waveguide, called the membrane MOT and the needle MOT, a key ingredient for efficient trap loading. We evaluate two novel designs that explore critical thermal management features that enable this large power handling. This work represents a significant step toward an integrated platform for coupling neutral atom quantum systems to photonic and electronic integrated circuits on silicon.
△ Less
Submitted 18 March, 2021; v1 submitted 2 January, 2021;
originally announced January 2021.
-
Results from phase 1 of the HAYSTAC microwave cavity axion experiment
Authors:
L. Zhong,
S. Al Kenany,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
R. H. Maruyama,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
D. H. Speller,
I. Urdinaran,
K. A. van Bibber
Abstract:
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range…
▽ More
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling $g_{aγγ}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}$, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15$\,<\,$$m_a \,$<$\,$24.0$\,μ\rm eV$. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature $T<hν/2k_B$ and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Authors:
S. Al Kenany,
M. A. Anil,
K. M. Backes,
B. M. Brubaker,
S. B. Cahn,
G. Carosi,
Y. V. Gurevich,
W. F. Kindel,
S. K. Lamoreaux,
K. W. Lehnert,
S. M. Lewis,
M. Malnou,
D. A. Palken,
N. M. Rapidis,
J. R. Root,
M. Simanovskaia,
T. M. Shokair,
I. Urdinaran,
K. A. van Bibber,
L. Zhong
Abstract:
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently comple…
▽ More
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: μ$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
△ Less
Submitted 22 February, 2017; v1 submitted 21 November, 2016;
originally announced November 2016.