THz-Pump and X-Ray-Probe Sources Based on an Electron Linac
Authors:
Sadiq Setiniyaz,
Seong Hee Park,
Hyun Woo Kim,
Nikolay A. Vinokurov,
Kyu-Ha Jang,
Kitae Lee,
In Hyung Baek,
Young Uk Jeong
Abstract:
We describe a compact THz-pump and X-ray-probe beamline, based on an electron linac, for ultrafast time-resolved diffraction applications. Two high-energy electron ($γ>50$) bunches, $5~$ns apart, impinge upon a single-foil or a multifoil radiator and generate THz radiation and X-rays simultaneously. The THz pulse from the first bunch is synchronized to the X-ray beam of the second bunch by using a…
▽ More
We describe a compact THz-pump and X-ray-probe beamline, based on an electron linac, for ultrafast time-resolved diffraction applications. Two high-energy electron ($γ>50$) bunches, $5~$ns apart, impinge upon a single-foil or a multifoil radiator and generate THz radiation and X-rays simultaneously. The THz pulse from the first bunch is synchronized to the X-ray beam of the second bunch by using an adjustable optical delay of THz pulse. The peak power of THz radiation from the multifoil radiator is estimated to be $0.14~$GW for a $200~$pC well-optimized electron bunch. GEANT4 simulations show a carbon foil with thickness of $0.5~-~1.0~$mm has the highest yield of $10~-~20~$keV hard X-rays for a $25~$MeV beam, which is approximately $10^3$ photons/(keV pC-electrons) within a few degrees of the polar angle. A carbon multifoil radiator with $35$ foils ($25~$$μm~$thick each) can generate close to $10^3$ hard X-rays/(keV pC-electrons) within a $2^\circ$ acceptance angle. With $200~$pC charge and $100~$Hz repetition rate, we can generate $10^7$ X-rays per $1~$keV energy bin per second or $10^5$ X-rays per $1~$keV energy bin per pulse. The longitudinal time profile of X-ray pulse ranges from $400~-~600~$fs depending on the acceptance angle. The broadening of the time duration of X-ray pulse is observed owing to its diverging effect. A double-crystal monochromator (DCM) will be used to select and transport the desired X-rays to the sample. The heating of the radiators by an electron beam is negligible because of the low beam current.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
Beam Characterization at the KAERI UED Beamline
Authors:
Sadiq Setiniyaz,
Hyun Woo Kim,
In-Hyung Baek,
Jinhee Nam,
MoonSik Chae,
Byung-Heon Han,
Boris Gudkov,
Kyu Ha Jang,
Sunjeong Park,
Sergey Miginsky,
Nikolay Vinokurov,
Young Uk Jeong
Abstract:
The UED (ultrafast electron diffraction) beamline of the KAERI's (the Korea Atomic Energy Research Institute's) WCI (World Class Institute) Center has been successfully commissioned. We have measured the beam emittance by using the quadrupole scan technique and the charge by using a novel measurement system we have developed. In the quadrupole scan, a larger drift distance between the quadrupole a…
▽ More
The UED (ultrafast electron diffraction) beamline of the KAERI's (the Korea Atomic Energy Research Institute's) WCI (World Class Institute) Center has been successfully commissioned. We have measured the beam emittance by using the quadrupole scan technique and the charge by using a novel measurement system we have developed. In the quadrupole scan, a larger drift distance between the quadrupole and the screen is preferred because it gives a better thin-lens approximation. A high bunch-charge beam, however, will undergo emittance growth in the long drift caused by the space-charge force. We present a method that mitigates this growth by introducing a quadrupole scan with a short drift and without using the thin-lens approximation. The quadrupole in this method is treated as a thick lens, and the emittance is extracted by using the thick-lens equations. Apart from being precise, our method can be readily applied without making any change to the beamline and has no need for a big drift space. For charge measurement, we have developed a system consisting of an in-air Faraday cup (FC) and a preamplifier. Tests performed utilizing 3.3-MeV electrons show that the system was able to measure bunches with pulse durations of tens of femtoseconds at 10 fC sensitivity.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.