-
Operation and performance of MEG II detector
Authors:
MEG II Collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (60 additional authors not shown)
Abstract:
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation…
▽ More
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
△ Less
Submitted 8 January, 2024; v1 submitted 18 October, 2023;
originally announced October 2023.
-
The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment
Authors:
The MEG II Collaboration,
Alessandro M. Baldini,
Vladimir Baranov,
Michele Biasotti,
Gianluigi Boca,
Paolo W. Cattaneo,
Gianluca Cavoto,
Fabrizio Cei,
Marco Chiappini,
Gianluigi Chiarello,
Alessandro Corvaglia,
Federica Cuna,
Giovanni dal Maso,
Antonio de Bari,
Matteo De Gerone,
Marco Francesconi,
Luca Galli,
Giovanni Gallucci,
Flavio Gatti,
Francesco Grancagnolo,
Marco Grassi,
Dmitry N. Grigoriev,
Malte Hildebrandt,
Kei Ieki,
Fedor Ignatov
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$)…
▽ More
The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.
△ Less
Submitted 1 September, 2021; v1 submitted 22 July, 2021;
originally announced July 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Beam particle tracking with a low-mass mini time projection chamber in the PEN experiment
Authors:
C. J. Glaser,
D. Pocanic,
A. van der Schaaf,
V. A. Baranov,
N. V. Khomutov,
N. P. Kravchuk,
N. A. Kuchinsky
Abstract:
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the m…
▽ More
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the mini time projection chamber (mTPC) used for pion, muon, and positron beam particle tracking. We also review the use of the extracted trajectory coordinates in the analysis, in particular in constructing observables critical for discriminating background processes, and in maximizing the fiducial volume of the target in which decay event vertices can be accepted for branching ratio extraction without introducing bias.
△ Less
Submitted 20 May, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
The design of the MEG II experiment
Authors:
A. M. Baldini,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
G. Cocciolo,
A. Corvaglia,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
M. Francesconi,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
D. N. Grigoriev,
M. Hildebrandt
, et al. (55 additional authors not shown)
Abstract:
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation…
▽ More
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.
△ Less
Submitted 15 January, 2018;
originally announced January 2018.
-
Muon polarization in the MEG experiment: predictions and measurements
Authors:
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. De Bari,
M. De Gerone,
A. DÓnofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama,
M. Hildebrandt
, et al. (45 additional authors not shown)
Abstract:
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at…
▽ More
The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.
△ Less
Submitted 28 April, 2016; v1 submitted 15 October, 2015;
originally announced October 2015.
-
2-D straw detectors with high rate capability
Authors:
N. A. Kuchinskiy,
V. A. Baranov,
V. N. Duginov,
F. E. Zyazyulya,
A. S. Korenchenko,
A. O. Kolesnikov,
N. P. Kravchuk,
S. A. Movchan,
A. I. Rudenko,
V. S. Smirnov,
N. V. Khomutov,
V. A. Chekhovsky,
A. S. Lobko,
O. V. Misevich
Abstract:
Precise measurement of straw axial coordinate (along the anode wire) with accuracy compatible with straw radial coordinate determination by drift time measurement and increase of straw detector rate capability by using straw cathode readout instead of anode readout are presented.
Precise measurement of straw axial coordinate (along the anode wire) with accuracy compatible with straw radial coordinate determination by drift time measurement and increase of straw detector rate capability by using straw cathode readout instead of anode readout are presented.
△ Less
Submitted 18 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Measurement of the radiative decay of polarized muons in the MEG experiment
Authors:
MEG Collaboration,
A. M. Baldini,
Y. Bao,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
G. Chiarello,
C. Chiri,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
S. Dussoni,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
A. Graziosi,
D. N. Grigoriev,
T. Haruyama
, et al. (46 additional authors not shown)
Abstract:
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV…
▽ More
We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.
△ Less
Submitted 7 March, 2016; v1 submitted 11 December, 2013;
originally announced December 2013.
-
The use of segmented cathode of a drift tube for designing a track detector with a high rate capability
Authors:
N. A. Kuchinskiy,
V. A. Baranov,
V. N. Duginov,
F. E. Zyazyulya,
A. S. Korenchenko,
A. O. Kolesnikov,
N. P. Kravchuk,
S. A. Movchan,
A. I. Rudenko,
V. S. Smirnov,
N. V. Khomutov,
V. A. Chekhovsky
Abstract:
Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method…
▽ More
Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method of increasing detector rate capability is increasing their granularity (a number of readout channels) by reducing the straw diameter and/or by dividing the straw anode wire into two parts (for decreasing the rate per readout channel). A new method of designing straw detectors with a high rate capability is presented and tested. The method is based on dividing the straw cathode into parts and independent readout of each part.
△ Less
Submitted 18 October, 2013;
originally announced October 2013.
-
MEG Upgrade Proposal
Authors:
A. M. Baldini,
F. Cei,
C. Cerri,
S. Dussoni,
L. Galli,
M. Grassi,
D. Nicolò,
F. Raffaelli,
F. Sergiampietri,
G. Signorelli,
F. Tenchini,
D. Bagliani,
M. De Gerone,
F. Gatti,
E. Baracchini,
Y. Fujii,
T. Iwamoto,
D. Kaneko,
T. Mori,
M. Nishimura,
W. Ootani,
R. Sawada,
Y. Uchiyama,
G. Boca,
P. W. Cattaneo
, et al. (43 additional authors not shown)
Abstract:
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to ena…
▽ More
We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.
△ Less
Submitted 4 February, 2013; v1 submitted 30 January, 2013;
originally announced January 2013.
-
Detector with a profile-based cathode and a two-coordinate pad-strip readout system
Authors:
N. A. Kuchinskiy,
V. A. Baturitskii,
N. P. Kravchuk,
A. S. Korenchenko,
N. V. Khomutov,
V. S. Smirnov,
V. A. Chekhovskii,
S. A. Movchan,
F. E. Zyazyulya
Abstract:
A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a sin…
▽ More
A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a single detector plane.
△ Less
Submitted 19 December, 2011;
originally announced December 2011.
-
Using the cathode surface of straw tube for measuring the track coordinates along the wire
Authors:
V. A. Baranov,
B. A. Chekhovskiy,
N. P. Kravchuk,
A. S. Korenchenko,
N. A. Kuchinskiy,
N. V. Khomutov,
S. A. Movchan,
V. S. Smirnov,
F. E. Zyazyulya
Abstract:
The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tu…
▽ More
The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tube detector using the signals from the cathodes of the detector.
△ Less
Submitted 27 January, 2012; v1 submitted 11 May, 2011;
originally announced May 2011.
-
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Authors:
I. Altarev,
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
P. Fierlinger,
B. Franke,
E. Gutsmiedl,
W. Heil,
R. Henneck,
M. Horras,
N. Khomutov,
K. Kirch,
S. Kistryn,
A. Kraft,
A. Knecht,
P. Knowles,
A. Kozela,
T. Lauer,
B. Lauss,
T. Lefort,
Y. Lemière,
A. Mtchedlishvili,
O. Naviliat-Cuncic
, et al. (16 additional authors not shown)
Abstract:
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in…
▽ More
Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
△ Less
Submitted 30 September, 2010;
originally announced September 2010.
-
Design, Commissioning and Performance of the PIBETA Detector at PSI
Authors:
E. Frlez,
D. Pocanic,
K. A. Assamagan,
Yu. Bagaturia,
V. A. Baranov,
W. Bertl,
Ch. Broennimann,
M. A. Bychkov,
J. F. Crawford,
M. Daum,
Th. Fluegel,
R. Frosch,
R. Horisberger,
V. A. Kalinnikov,
V. V. Karpukhin,
N. V. Khomutov,
J. E. Koglin,
A. S. Korenchenko,
S. M. Korenchenko,
T. Kozlowski,
B. Krause,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
D. W. Lawrence
, et al. (19 additional authors not shown)
Abstract:
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an ac…
▽ More
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.
△ Less
Submitted 4 December, 2003;
originally announced December 2003.