-
Increasing quantum speed meter sensitivity using optical spring
Authors:
L. A. Barinov,
F. Ya. Khalili
Abstract:
The double-pass interferometer scheme was proposed in Ref.\,[Light Sci. Appl. {\bf 7}, 11 (2018)] as the method of implementation of the quantum speed meter concept in future laser gravitational-wave (GW) detectors. Later it was shown in Ref.\,[Phys. Rev. D {\bf 110}, 062006 (2024)] that it allows to implement the new type of the optical spring that does not require detuning of the interferometer.…
▽ More
The double-pass interferometer scheme was proposed in Ref.\,[Light Sci. Appl. {\bf 7}, 11 (2018)] as the method of implementation of the quantum speed meter concept in future laser gravitational-wave (GW) detectors. Later it was shown in Ref.\,[Phys. Rev. D {\bf 110}, 062006 (2024)] that it allows to implement the new type of the optical spring that does not require detuning of the interferometer. Here we show that both these regimes can coexist, combining the speed meter type broadband sensitivity gain with the additional lows-frequency minimum in the quantum noise originated from the optical spring. We show that the location of this minimum can be varied without affecting the core optics of the interferometer, allowing to tune the quantum noise shape in real time to follow the ``chirp'' GW signals.
△ Less
Submitted 13 March, 2025;
originally announced March 2025.
-
Computational Analysis of Inspiratory and Expiratory Flow in the Lung Airway
Authors:
Peshala P. T Gamage,
Fardin Khalili,
Azad Md. K,
Hansen A Mansy
Abstract:
Inspiratory and expiratory flow in a multi-generation pig lung airway was numerically studied at a peak tracheal flow rate corresponding to a Reynolds number of 1150. The model was validated by comparing velocity distributions with previous measurements for a simple airway bifurcation. Simulation results at different cross sections of the airway tree provided detailed maps of the axial and seconda…
▽ More
Inspiratory and expiratory flow in a multi-generation pig lung airway was numerically studied at a peak tracheal flow rate corresponding to a Reynolds number of 1150. The model was validated by comparing velocity distributions with previous measurements for a simple airway bifurcation. Simulation results at different cross sections of the airway tree provided detailed maps of the axial and secondary flow patterns. Flow at the main bifurcation and in many other bifurcations showed complex secondary flow structures. The flow morphology in the pig airways differed from that of simplified bifurcation airway models and that of humans, which is likely due to the large differences in the airway geometry of the different species. The inspiratory pressure drop was calculated, and simulation results suggested that the viscous pressure drop values were comparable to earlier studies in human airway geometries. The reported differences between pig and human airways need to be taken into consideration when generalizing results of animal experiments to humans.
△ Less
Submitted 17 April, 2018;
originally announced April 2018.
-
A coupled CFD-FEA study of the sound generated in a stenosed artery and transmitted through tissue layers
Authors:
Fardin Khalili,
Peshala P T Gamage,
Ibrahim A Meguid,
Hansen A Mansy
Abstract:
A new computational approach for simulating the blood flow induced sound generation and propagation in a stenosed artery with one-sided constriction was investigated. This computational hemoacoustic method is based on mapping the transient pressure (force) fluctuations on the vessel wall and solving for the structural vibrations in frequency domain. These vibrations were detected as sound on the e…
▽ More
A new computational approach for simulating the blood flow induced sound generation and propagation in a stenosed artery with one-sided constriction was investigated. This computational hemoacoustic method is based on mapping the transient pressure (force) fluctuations on the vessel wall and solving for the structural vibrations in frequency domain. These vibrations were detected as sound on the epidermal surface. The current hydro vibroacoustic method employs a two step, one way coupled approach for the sound generation in the flow domain and its propagation through the tissue layers. The results were validated by comparing with previous analytical and computational solutions. It was found that the bruits (generated from the flow around the stenosis) are related primarily to the time derivative of the integrated pressure force on the arterial wall downstream of the stenosis. Advantages of the methods used in the current study include: (a) capability of providing accurate solution with a faster solution time; (b) accurately capturing the break frequency of the velocity fluctuation measured on epidermal surface; (c) inclusion of the fluid structure interaction between blood flow and the arterial wall.
△ Less
Submitted 9 April, 2018;
originally announced April 2018.
-
Verification of Turbulence Models for Flow in a Constricted Pipe at Low Reynolds Number
Authors:
Fardin Khalili,
Peshala P. T. Gamage,
Hansen A. Mansy
Abstract:
Computational fluid dynamics (CFD) is a useful tool for prediction of turbulence in aerodynamic and biomedical applications. The choice of appropriate turbulence models is key to reaching accurate predictions. The present investigation concentrated on the comparison of different turbulence models for predicting the flow field downstream of a constricted pipe. This geometry is relevant to arterial…
▽ More
Computational fluid dynamics (CFD) is a useful tool for prediction of turbulence in aerodynamic and biomedical applications. The choice of appropriate turbulence models is key to reaching accurate predictions. The present investigation concentrated on the comparison of different turbulence models for predicting the flow field downstream of a constricted pipe. This geometry is relevant to arterial stenosis in patients with vascular diseases. More specifically, the results of Unsteady Reynolds-Averaged Navier-Stokes (URANS) and scale resolving simulation (SRS) turbulence models such as Large Eddy Simulation (LES) and Detached Eddy Simulation (DES) were compared with experimental measurements. Comparisons included the mean flow and fluctuations downstream of the constriction. Results showed that the LES model was in better agreement with the velocity measurements performed using a Laser Doppler Anemometry (LDA). In addition, although URANS models predicted a wake region size and mean flow velocities comparable to SRS turbulence models, no small-scale vortical structures can be observed in the URANS solution due to the nature of these models. Modeling of these structures would, however, be helpful when more detailed flow behavior is needed such as in studies of acoustic sources. Hence, LES would be an optimal turbulence model for the flow under consideration, especially when sound generation would be of interest.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Numerical Modeling of Pulse Wave Propagation in a Stenosed Artery using Two-Way Coupled Fluid Structure Interaction (FSI)
Authors:
Peshala P. T Gamage,
Fardin Khalili,
Hansen A Mansy
Abstract:
As the heart beats, it creates fluctuation in blood pressure leading to a pulse wave that propagates by displacing the arterial wall. These waves travel through the arterial tree and carry information about the medium that they propagate through as well as information of the geometry of the arterial tree. Pulse wave velocity (PWV) can be used as a non-invasive diagnostic tool to study the function…
▽ More
As the heart beats, it creates fluctuation in blood pressure leading to a pulse wave that propagates by displacing the arterial wall. These waves travel through the arterial tree and carry information about the medium that they propagate through as well as information of the geometry of the arterial tree. Pulse wave velocity (PWV) can be used as a non-invasive diagnostic tool to study the functioning of cardiovascular system. A stenosis in an artery can dampen the pulse wave leading to changes in the propagating pulse. Hence, PWV analysis can be performed to detect a stenosed region in arteries. This paper presents a numerical study of pulse wave propagation in a stenosed artery by means of two-way coupled fluid structure interaction (FSI). The computational model was validated by the comparison of the simulated PWV results with theoretical values for a healthy artery. Propagation of the pulse waves in the stenosed artery was compared with healthy case using spatiotemporal maps of wall displacements. The analysis for PWV showed significance differences between the healthy and stenosed arteries including damping of propagating waves and generation of high wall displacements downstream the stenosis caused by flow instabilities. This approach can be used to develop patient-specific models that are capable of predicting PWV signatures associated with stenosis changes. The knowledge gained from these models may increase utility of this approach for managing patients at risk of stenosis occurrence.
△ Less
Submitted 9 March, 2018;
originally announced March 2018.
-
The Influence of the Aortic Root Geometry on Flow Characteristics of a Bileaflet Mechanical Heart Valve
Authors:
Fardin Khalili,
Peshala P. T. Gamage,
Hansen A. Mansy
Abstract:
Bileaflet mechanical heart valves have one of the most successful valve designs for more than 30 years. These valves are often used for aortic valve replacement, where the geometry of the aortic root sinuses may vary due to valvular disease and affect valve performance. Common geometrical sinus changes may be due to valve stenosis and insufficiency. In the current study, the effect of these geomet…
▽ More
Bileaflet mechanical heart valves have one of the most successful valve designs for more than 30 years. These valves are often used for aortic valve replacement, where the geometry of the aortic root sinuses may vary due to valvular disease and affect valve performance. Common geometrical sinus changes may be due to valve stenosis and insufficiency. In the current study, the effect of these geometrical changes on the mean flow and velocity fluctuations downstream of the valve and aortic sinuses were investigated. The study focused on the fully-open leaflet position where blood velocities are close to their maximum. Simulation results were validated using previous experimental laser Doppler anemometry (LDA) measurements. Results showed that as the stenosis and insufficiency increased there were more flow separation and increased local mean velocity downstream of the leaflets. In addition, the detected elevated velocity fluctuations were associated with higher Reynolds shear stresses levels, which may increase the chances of blood damage and platelet activation and may lead to increased risk of blood clot formation.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Prediction of Turbulent Shear Stresses through Dysfunctional Bileaflet Mechanical Heart Valves using Computational Fluid Dynamics
Authors:
Fardin Khalili,
Peshala T. Gamage,
Hansen Mansy
Abstract:
There are more than 300,000 heart valves implanted annually worldwide with about 50% of them being mechanical valves. The heart valve replacement is often a common treatment for severe valvular disease. However, valves may dysfunction leading to adverse hemodynamic conditions. The current computational study investigated the flow around a bileaflet mechanical heart valve at different leaflet dysfu…
▽ More
There are more than 300,000 heart valves implanted annually worldwide with about 50% of them being mechanical valves. The heart valve replacement is often a common treatment for severe valvular disease. However, valves may dysfunction leading to adverse hemodynamic conditions. The current computational study investigated the flow around a bileaflet mechanical heart valve at different leaflet dysfunction levels of 0%, 50%, and 100%, and documented the relevant flow characteristics such as vortical structures and turbulent shear stresses. Studying the flow characteristics through these valves during their normal operation and dysfunction can lead to better understanding of their performance, possibly improved designs, and help identify conditions that may increase the potential risk of blood cell damage. Results suggested that maximum flow velocities increased with dysfunction from 2.05 to 4.49 ms-1 which were accompanied by growing eddies and velocity fluctuations. These fluctuations led to higher turbulent shear stresses from 90 to 800 N.m-2 as dysfunctionality increased. These stress values exceeded the thresholds corresponding to elevated risk of hemolysis and platelet activation. The regions of elevated stresses were concentrated around and downstream of the functional leaflet where high jet velocity and stronger helical structures existed.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Hemodynamics of a Bileaflet Mechanical Heart Valve with Different Levels of Dysfunction
Authors:
Fardin Khalili,
Peshala P. T. Gamage,
Hansen A. Mansy
Abstract:
Heart disease is one of leading causes of mortality worldwide. Healthy heart valves are key for proper heart function. When these valves dysfunction, a replacement is often necessary in severe cases. The current study presents an investigation of the pulsatile blood flow through a bileaflet mechanical heart valve (BMHV) where one leaflet is healthy and can fully open and the other leaflet cannot f…
▽ More
Heart disease is one of leading causes of mortality worldwide. Healthy heart valves are key for proper heart function. When these valves dysfunction, a replacement is often necessary in severe cases. The current study presents an investigation of the pulsatile blood flow through a bileaflet mechanical heart valve (BMHV) where one leaflet is healthy and can fully open and the other leaflet cannot fully open with different levels of dysfunction. To better understand the implications that a dysfunctional leaflet has on the blood flow through these valves, analysis of flow characteristics such as velocity, pressure drop, wall shear stress and vorticity profiles was performed. Results suggested that leaflet dysfunction caused increased local velocities, separation regions and wall shear stresses. For example, the maximum velocity increased from 2.53 m/s to 4.9 m/s when dysfunction increased from 0% to 100%. The pressure drop increased (by up to 300%) with dysfunctionality. Results suggested that leaflet dysfunction also caused increased wall shear stresses on the valve frame where higher stresses developed around the hinges (at 75% and 100% dysfunctions). Analysis also showed that increased dysfunctionality of one leaflet led to higher net shear forces on both the healthy and dysfunctional leaflets (by up to 200% and 600%, respectively).
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Observation of generalized optomechanical coupling and cooling on cavity resonance
Authors:
Andreas Sawadsky,
Henning Kaufer,
Ramon Moghadas Nia,
Sergey P. Tarabrin,
Farid Ya. Khalili,
Klemens Hammerer,
Roman Schnabel
Abstract:
Optomechanical coupling between a light field and the motion of a cavity mirror via radiation pressure plays an important role for the exploration of macroscopic quantum physics and for the detection of gravitational waves (GWs). It has been used to cool mechanical oscillators into their quantum ground states and has been considered to boost the sensitivity of GW detectors, e.g. via the optical sp…
▽ More
Optomechanical coupling between a light field and the motion of a cavity mirror via radiation pressure plays an important role for the exploration of macroscopic quantum physics and for the detection of gravitational waves (GWs). It has been used to cool mechanical oscillators into their quantum ground states and has been considered to boost the sensitivity of GW detectors, e.g. via the optical spring effect. Here, we present the experimental characterization of generalized, that is, dispersive and dissipative optomechanical coupling, with a macroscopic (1.5mm)^2-sized silicon nitride (SiN) membrane in a cavity-enhanced Michelson-type interferometer. We report for the first time strong optomechanical cooling based on dissipative coupling, even on cavity resonance, in excellent agreement with theory. Our result will allow for new experimental regimes in macroscopic quantum physics and GW detection.
△ Less
Submitted 26 January, 2015; v1 submitted 11 September, 2014;
originally announced September 2014.
-
Anomalous dynamic back-action in interferometers
Authors:
Sergey P. Tarabrin,
Henning Kaufer,
Farid Ya. Khalili,
Roman Schnabel,
Klemens Hammerer
Abstract:
We analyze the dynamic optomechanical back-action in signal-recycled Michelson and Michelson-Sagnac interferometers that are operated off dark port. We show that in this case --- and in contrast to the well-studied canonical form of dynamic back-action on dark port --- optical damping in a Michelson-Sagnac interferometer acquires a non-zero value on cavity resonance, and additional stability/insta…
▽ More
We analyze the dynamic optomechanical back-action in signal-recycled Michelson and Michelson-Sagnac interferometers that are operated off dark port. We show that in this case --- and in contrast to the well-studied canonical form of dynamic back-action on dark port --- optical damping in a Michelson-Sagnac interferometer acquires a non-zero value on cavity resonance, and additional stability/instability regions on either side of the resonance, revealing new regimes of cooling/heating of micromechanical oscillators. In a free-mass Michelson interferometer for a certain region of parameters we predict a stable single-carrier optical spring (positive spring and positive damping), which can be utilized for the reduction of quantum noise in future-generation gravitational-wave detectors.
△ Less
Submitted 23 August, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
Interferometer readout-noise below the Standard Quantum Limit of a membrane
Authors:
Tobias Westphal,
Daniel Friedrich,
Henning Kaufer,
Kazuhiro Yamamoto,
Stefan Gossler,
Helge Mueller-Ebhardt,
Stefan L. Danilishin,
Farid Ya. Khalili,
Karsten Danzmann,
Roman Schnabel
Abstract:
Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of 3E-16 m/sqrt(Hz) at frequencies around the fundamental resonance of a SiN_x membrane at about 100 kHz, without using optical cavities. The read…
▽ More
Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of 3E-16 m/sqrt(Hz) at frequencies around the fundamental resonance of a SiN_x membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This reduction is significantly higher than those of previous works with nano-wires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and conclude that neither our nor previous experiments achieved a total noise spectral density as low as the SQL.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Laser interferometry with translucent and absorbing mechanical oscillators
Authors:
D. Friedrich,
H. Kaufer,
T. Westphal,
K. Yamamoto,
A. Sawadsky,
F. Ya. Khalili,
S. Danilishin,
S. Goßler,
K. Danzmann,
R. Schnabel
Abstract:
The sensitivity of laser interferometers can be pushed into regimes that enable the direct observation of quantum behaviour of mechanical oscillators. In the past, membranes with subwavelength thickness (thin films) have been proposed as high-mechanical-quality, low-thermal-noise oscillators. Thin films from a homogenous material, however, generally show considerable light transmission accompanied…
▽ More
The sensitivity of laser interferometers can be pushed into regimes that enable the direct observation of quantum behaviour of mechanical oscillators. In the past, membranes with subwavelength thickness (thin films) have been proposed as high-mechanical-quality, low-thermal-noise oscillators. Thin films from a homogenous material, however, generally show considerable light transmission accompanied by heating due to light absorption, which typically reduces the mechanical quality and limits quantum opto-mechanical experiments in particular at low temperatures. In this work, we experimentally analyze a Michelson-Sagnac interferometer including a translucent silicon nitride (SiN) membrane with subwavelength thickness. We find that such an interferometer provides an operational point being optimally suited for quantum opto-mechanical experiments with translucent oscillators. In case of a balanced beam splitter of the interferometer, the membrane can be placed at a node of the electro-magnetic field, which simultaneously provides lowest absorption and optimum laser noise rejection at the signal port. We compare the optical and mechanical model of our interferometer with experimental data and confirm that the SiN membrane can be coupled to a laser power of the order of one Watt at 1064 nm without significantly degrading the membrane's quality factor of the order 10^6, at room temperature.
△ Less
Submitted 16 April, 2011;
originally announced April 2011.
-
Negative optical inertia for enhancing the sensitivity of future gravitational-wave detectors
Authors:
Farid Khalili,
Stefan Danilishin,
Helge Mueller-Ebhardt,
Haixing Miao,
Yanbei Chen,
Chunnong Zhao
Abstract:
We consider enhancing the sensitivity of future gravitational-wave detectors by using double optical spring. When the power, detuning and bandwidth of the two carriers are chosen appropriately, the effect of the double optical spring can be described as a "negative inertia", which cancels the positive inertia of the test masses and thus increases their response to gravitational waves. This allows…
▽ More
We consider enhancing the sensitivity of future gravitational-wave detectors by using double optical spring. When the power, detuning and bandwidth of the two carriers are chosen appropriately, the effect of the double optical spring can be described as a "negative inertia", which cancels the positive inertia of the test masses and thus increases their response to gravitational waves. This allows us to surpass the free-mass Standard Quantum Limit (SQL) over a broad frequency band, through signal amplification, rather than noise cancelation, which has been the case for all broadband SQL-beating schemes so far considered for gravitational-wave detectors. The merit of such signal amplification schemes lies in the fact that they are less susceptible to optical losses than noise cancelation schemes. We show that it is feasible to demonstrate such an effect with the {\it Gingin High Optical Power Test Facility}, and it can eventually be implemented in future advanced GW detectors.
△ Less
Submitted 6 October, 2010;
originally announced October 2010.
-
Optimal configurations of filter cavity in future gravitational-wave detectors
Authors:
Farit Ya. Khalili
Abstract:
Sensitivity of future laser interferometric gravitational-wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during last years, assuming the case of a single relatively short (tens of meters) filter cavi…
▽ More
Sensitivity of future laser interferometric gravitational-wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during last years, assuming the case of a single relatively short (tens of meters) filter cavity suitable for implementation already during the life cycle of the second generation detectors, like Advanced LIGO. Using numerical optimization, we show that the phase filtering scheme proposed by Kimble et al [Phys.Rev.D 65, 022002 (2001)] looks as the best candidate for this scenario.
△ Less
Submitted 15 March, 2010;
originally announced March 2010.