-
First characterisation of the MAGO cavity, a superconducting RF detector for kHz-MHz gravitational waves
Authors:
Lars Fischer,
Bianca Giaccone,
Ivan Gonin,
Anna Grassellino,
Wolfgang Hillert,
Timergali Khabiboulline,
Tom Krokotsch,
Gudrid Moortgat-Pick,
Andrea Muhs,
Yuriy Orlov,
Michel Paulsen,
Krisztian Peters,
Sam Posen,
Oleg Pronitchev,
Marc Wenskat
Abstract:
Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency gravitational waves detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviat…
▽ More
Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency gravitational waves detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity's gravitational wave coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.
△ Less
Submitted 17 June, 2025; v1 submitted 27 November, 2024;
originally announced November 2024.
-
Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat
Authors:
A. Sukhanov,
C. Contreras-Martinez,
C. Grimm,
B. Hanna,
B. Hansen,
T. Khabiboulline,
M. Parise,
D. Passarelli,
Y. Pischalnikov,
D. Porwisiak,
V. Roger,
J. Subedi,
A. Syed,
P. Varghese,
S. Wijethunga,
V. Yakovlev
Abstract:
As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qua…
▽ More
As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.
△ Less
Submitted 25 November, 2024;
originally announced November 2024.
-
Excellent performance of 650 MHz single-cell niobium cavity after electropolishing
Authors:
V. Chouhan,
D. Bice,
A. Cravatta,
T. Khabiboulline,
O. Melnychuk,
A. Netepenko,
G. Wu,
B. Guilfoyle,
T. Reid
Abstract:
Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was no…
▽ More
Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.
△ Less
Submitted 9 October, 2024;
originally announced October 2024.
-
Gridded RF Gun Design for SRF Linac Applications
Authors:
I. Gonin,
C. Edwards,
S. Kazakov,
T. Khabiboulline,
T. Nicol,
A. Saini,
N. Solyak,
J. C. T. Thangaraj,
V. Yakovlev,
M. Curtis,
K. Gunther
Abstract:
The thermionic gridded gun is described which generates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measurements, which are in…
▽ More
The thermionic gridded gun is described which generates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measurements, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current interception in the SRF cavity.
△ Less
Submitted 11 September, 2024;
originally announced September 2024.
-
Performance of PIP-II High-beta 650 Cryomodule After Transatlantic Shipping
Authors:
J. Ozelis,
M. Barba,
J. Bernardini,
C. Contreras-Martinez,
D. Crawford,
J. Dong,
V. Grzelak,
P. Hanlet,
J. Holzbauer,
Y. Jia,
S. Kazakov,
T. Khabiboulline,
J. Makara,
N. Patel,
V. Patel,
L. Pei,
D. Peterson,
Y. Pischalnikov,
D. Porwisiak,
S. Ranpariya,
J. Steimel,
N. Solyak,
J. Subedi,
A. Sukhanov,
P. Varghese
, et al. (5 additional authors not shown)
Abstract:
After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity f…
▽ More
After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.
△ Less
Submitted 3 September, 2024;
originally announced September 2024.
-
Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II
Authors:
A. Lunin,
T. Khabiboulline,
A. Sukhanov,
V. Yakovlev
Abstract:
Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the…
▽ More
Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.
△ Less
Submitted 20 August, 2024;
originally announced August 2024.
-
On forced RF generation of CW magnetrons for SRF accelerators
Authors:
G. Kazakevich,
R. P. Johnson,
T. Khabiboulline,
G. Romanov,
V. Yakovlev,
Ya Derbenev,
Yu. Eidelman
Abstract:
CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This ca…
▽ More
CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.
△ Less
Submitted 24 April, 2024;
originally announced April 2024.
-
Impact of Solenoid Induced Residual Magnetic Fields on The Prototype SSR1 CM Performance
Authors:
D. Passarelli,
J. Bernardini,
C. Boffo,
S. Chandrasekaran,
A. Hogberg,
T. Khabiboulline,
J. Ozelis,
M. Parise,
V. Roger,
G. Romanov,
A. Sukhanov,
G. Wu,
V. Yakovlev,
Y. Xie
Abstract:
A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, desig…
▽ More
A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.
△ Less
Submitted 26 January, 2024;
originally announced January 2024.
-
Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K
Authors:
C. Contreras-Martinez,
B. Giaccone,
I. Gonin,
T. Khabiboulline,
O. Melnychuk,
Y. Pischalnikov,
S. Posen,
O. Pronitchev,
JC. Yun
Abstract:
At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The…
▽ More
At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
Development of 3-cell Traveling Wave SRF Cavity
Authors:
F. Furuta,
V. Yakovlev,
T. Khabiboulline,
K. McGee,
R. Kostin,
P. Avrakhov
Abstract:
Traveling wave SRF cavity is a new technology and requires a multi-stage process for development. Conceptual designs have been proposed to adopt TW resonance in an SRF cavity The early stages of developments have been funded by several SBIR grants to Euclid Techlabs which were completed in collaboration with Fermilab. A 3-cell proof-of-principle TW cavity was fabricated as part of that and demonst…
▽ More
Traveling wave SRF cavity is a new technology and requires a multi-stage process for development. Conceptual designs have been proposed to adopt TW resonance in an SRF cavity The early stages of developments have been funded by several SBIR grants to Euclid Techlabs which were completed in collaboration with Fermilab. A 3-cell proof-of-principle TW cavity was fabricated as part of that and demonstrated the TW resonance excitation at room temperature. A TW resonance control tuner for the 3-cell was also fabricated and the preliminary tests were performed. Now, the 3-cell cavity is being processed and prepared for the first cryogenic testing.
△ Less
Submitted 18 July, 2023;
originally announced July 2023.
-
The Evaluation of Mechanical Properties of LB650 Cavities
Authors:
J. Holzbauer,
G. Wu,
H. Park,
K. McGee,
A. Wixson,
T. Khabiboulline,
G. Romanov,
S. Adams,
D. Bice,
S. K. Chandrasekaran,
J. Ozelis,
I. Gonin,
C. Narug,
R. Thiede,
R. Treece,
C. Grimm
Abstract:
The PIP-II project's LB650 cavities could potentially be vulnerable to mechanical deformation because of the geometric shape of the cavity due to reduced beta. The mechanical property of the niobium half-cell was measured following various heat treatments. The 5-cell cavities were tested in a controlled drop test fashion and the real-world road test. The result showed that the 900 $°$C heat treatm…
▽ More
The PIP-II project's LB650 cavities could potentially be vulnerable to mechanical deformation because of the geometric shape of the cavity due to reduced beta. The mechanical property of the niobium half-cell was measured following various heat treatments. The 5-cell cavities were tested in a controlled drop test fashion and the real-world road test. The result showed that the 900 $°$C heat treatment was compatible with cavity handling and transportation during production. The test provides the bases of the transportation specification and shipping container design guidelines.
△ Less
Submitted 18 July, 2023;
originally announced July 2023.
-
New Exclusion Limit for Dark Photons from an SRF Cavity-Based Search (Dark SRF)
Authors:
A. Romanenko,
R. Harnik,
A. Grassellino,
R. Pilipenko,
Y. Pischalnikov,
Z. Liu,
O. S. Melnychuk,
B. Giaccone,
O. Pronitchev,
T. Khabiboulline,
D. Frolov,
S. Posen,
A. Berlin,
A. Hook
Abstract:
We conduct the first ``light-shining-through-wall" (LSW) search for dark photons using two state-of-the-art high quality-factor superconducting radio frequency (SRF) cavities and report the results of its pathfinder run. Our new experimental setup enables improvements in sensitivity over previous searches and covers new dark photon parameter space. We design delicate calibration and measurement pr…
▽ More
We conduct the first ``light-shining-through-wall" (LSW) search for dark photons using two state-of-the-art high quality-factor superconducting radio frequency (SRF) cavities and report the results of its pathfinder run. Our new experimental setup enables improvements in sensitivity over previous searches and covers new dark photon parameter space. We design delicate calibration and measurement protocols to utilize the high-$Q$ setup at Dark SRF. Using cavities operating at $1.3 \ \text{GHz}$, we establish a new exclusion limit for kinetic mixing as small as {$ε= 1.6\times 10^{-9}$} and provide the world's best constraints on dark photons in the $2.1\times 10^{-7} \ \text{eV} - 5.7\times10^{-6} \ \text{eV}$ mass range. Our result is the first proof-of-concept for the enabling role of SRF cavities in LSW setups, with ample opportunities for further improvements. In addition, our data sets a competitive lab-based limit on the Standard Model photon mass by searching for longitudinal photon polarization.
△ Less
Submitted 26 January, 2023;
originally announced January 2023.
-
Tests Of The Extended Range SRF Cavity Tuners For The LCLS-II-HE Project*
Authors:
C. Contreras-Martinez,
T. Arkan,
A. Cravatta,
B. Hartsell,
J. Kaluzny,
T. Khabiboulline,
Y. Pischalnikov,
S. Posen,
G. Romanov,
JC. Yun
Abstract:
The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in the verification cryomodule (vCM) and CM 1 at Fermilab at 2 K. In both cases, the tuners achieved a frequency shift of -565$\pm$80 kHz. This…
▽ More
The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in the verification cryomodule (vCM) and CM 1 at Fermilab at 2 K. In both cases, the tuners achieved a frequency shift of -565$\pm$80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Validation of the 650 MHZ SRF tuner on the low and high beta cavities for PIP-II at 2 K*
Authors:
C. Contreras-Martinez,
S. Chandrasekaran,
S. Cheban,
G. Eremeev,
I. Gonin,
T. Khabiboulline,
Y. Pischalnikov,
O. Prokofiev,
A. Sukhanov,
JC. Yun
Abstract:
The PIP-II linac will include thirty-six beta=0.61 and twenty-four beta=0.92 650 MHz 5 cell elliptical SRF cavities. Each cavity will be equipped with a tuning system consisting of a double lever slow tuner for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. The same tuner will be used for both the beta=0.61 and beta=0.92 cavities. Results of testing the cavity-tune…
▽ More
The PIP-II linac will include thirty-six beta=0.61 and twenty-four beta=0.92 650 MHz 5 cell elliptical SRF cavities. Each cavity will be equipped with a tuning system consisting of a double lever slow tuner for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. The same tuner will be used for both the beta=0.61 and beta=0.92 cavities. Results of testing the cavity-tuner system for the beta=0.61 will be presented for the first time.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Design of axion and axion dark matter searches based on ultra high Q SRF cavities
Authors:
Bianca Giaccone,
Asher Berlin,
Ivan Gonin,
Anna Grassellino,
Roni Harnik,
Yonatan Kahn,
Timergali Khabiboulline,
Andrei Lunin,
Oleksandr Melnychuk,
Alexander Netepenko,
Roman Pilipenko,
Yuriy Pischalnikov,
Sam Posen,
Oleg Pronitchev,
Alex Romanenko,
Vyacheslav Yakovlev
Abstract:
The Superconducting Quantum Materials and Systems center is developing searches for dark photons, axions and ALPs with the goal of improving upon the current state-of-the-art sensitivity. These efforts leverage on Fermi National Accelerator expertise on ultra-high quality factor superconducting radio frequency cavities combined with the center research on quantum technology. Here we focus on multi…
▽ More
The Superconducting Quantum Materials and Systems center is developing searches for dark photons, axions and ALPs with the goal of improving upon the current state-of-the-art sensitivity. These efforts leverage on Fermi National Accelerator expertise on ultra-high quality factor superconducting radio frequency cavities combined with the center research on quantum technology. Here we focus on multiple axion searches that utilize ~1E10 quality factor superconducting radio frequency cavities and their resonant modes to enhance the production and/or detection of axions in the cavity volume. In addition, we present preliminary results of single-mode and multi-mode nonlinearity measurements that were carried out as part of an experimental feasibility study to gain insight on the behavior of the ultra-high quality factor resonators and the experimental RF system in the regime relevant for axion searches.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Tuning of Multicell Superconducting Accelerating Cavities using Pressurized Balloons
Authors:
Mohamed H. Awida,
Donato Passarelli,
Marco Castellari,
Alessandro Tesi,
Timergali Khabiboulline
Abstract:
Plastic tuning of multicell superconducting accelerating cavities is crucial in the development cycle of cavities for particle accelerators. Cavities must meet stringent requirements regarding the operating mode frequency, field flatness, and eccentricity before lining them up in a cryomodule string. After dressing bare cavities with helium vessels, the welded vessel prevents access to individual…
▽ More
Plastic tuning of multicell superconducting accelerating cavities is crucial in the development cycle of cavities for particle accelerators. Cavities must meet stringent requirements regarding the operating mode frequency, field flatness, and eccentricity before lining them up in a cryomodule string. After dressing bare cavities with helium vessels, the welded vessel prevents access to individual cavity cells disallowing any further localized tuning. Currently, there is no straightforward way to tune dressed cavities other than cutting the vessel and then tuning the bare cavity and dressing it back, which would significantly impact cost and schedule. In this paper, we present a novel tuning technique for already jacketed cavities that is non-invasive and cost-effective. The proposed scheme employs pressurized balloons to be temporarily deployed inside the cavity as a means to localize mechanical deformation in specific cells. The proposed tuning technique was successfully utilized to recover a 9-cell 1.3 GHz tesla-style cavity.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
Measurement of high quality factor superconducting cavities in tesla-scale magnetic fields for dark matter searches
Authors:
S. Posen,
M. Checchin,
O. S. Melnychuk,
T. Ring,
I. Gonin,
T. Khabiboulline
Abstract:
In dark matter searches using axion haloscopes, the search sensitivity depends on the quality factors ($Q_0$) of radiofrequency cavities immersed in multi-tesla magnetic fields. Increasing $Q_0$ would increase the scan rate through the parameter space of interest. Researchers developing superconducting radiofrequency cavities for particle accelerators have developed methods for obtaining extremely…
▽ More
In dark matter searches using axion haloscopes, the search sensitivity depends on the quality factors ($Q_0$) of radiofrequency cavities immersed in multi-tesla magnetic fields. Increasing $Q_0$ would increase the scan rate through the parameter space of interest. Researchers developing superconducting radiofrequency cavities for particle accelerators have developed methods for obtaining extremely high $Q_0\sim10^{11}$ in $μ$T-scale magnetic fields. In this paper, we describe efforts to develop high Q cavities made from Nb$_3$Sn films using a technique developed for particle accelerator cavities. Geometry optimization for this application is explored, and two cavities are tested: an existing particle accelerator-style cavity and a geometry developed and fabricated for use in high fields. A quality factor of ($5.3\pm0.3$)$\times 10^5$ is obtained at 3.9~GHz and 6~T at 4.2~K.
△ Less
Submitted 15 November, 2022; v1 submitted 25 January, 2022;
originally announced January 2022.
-
Design of a medium energy, high average power superconducting e-beam accelerator for environmental applications
Authors:
R. C. Dhuley,
I. Gonin,
K. Zeller,
R. Kostin,
S. Kazakov,
B. Coriton,
T. Khabiboulline,
A. Sukhanov,
V. Yakovlev,
A. Saini,
N. Solyak,
A. Sauers,
J. C. T. Thangaraj
Abstract:
We present the technical and engineering design of a medium energy (10 MeV) and high average power (1 MW) electron beam accelerator intended for irradiation treatment of high volume industrial and municipal wastewater. The accelerator uses superconducting radiofrequency (SRF) cavity technology for producing the high average beam power with $>$90% RF to beam efficiency. The design of the accelerato…
▽ More
We present the technical and engineering design of a medium energy (10 MeV) and high average power (1 MW) electron beam accelerator intended for irradiation treatment of high volume industrial and municipal wastewater. The accelerator uses superconducting radiofrequency (SRF) cavity technology for producing the high average beam power with $>$90% RF to beam efficiency. The design of the accelerator is simplified and tailored for industrial settings by adopting the cryocooler conduction-cooling technique for the SRF cavity instead of a conventional liquid helium bath cryo-system. The technical design is supplemented with a detailed analysis of capital and operating cost of the accelerator. The designed accelerator can treat up to 12 million gallons per day of wastewater, requires capital of $\sim\$$8M for construction, and has $\sim$13.5 cents/ton/kGy in material processing cost.
△ Less
Submitted 26 December, 2021; v1 submitted 16 December, 2021;
originally announced December 2021.
-
LCLS-II-HE verification cryomodule high gradient performance and quench behavior
Authors:
S. Posen,
A. Cravatta,
M. Checchin,
S. Aderhold,
C. Adolphsen,
T. Arkan,
D. Bafia,
A. Benwell,
D. Bice,
B. Chase,
C. Contreras-Martinez,
L. Dootlittle,
J. Fuerst,
D. Gonnella,
A. Grassellino,
C. Grimm,
B. Hansen,
E. Harms,
B. Hartsell,
G. Hays,
J. Holzbauer,
S. Hoobler,
J. Kaluzny,
T. Khabiboulline,
M. Kucera
, et al. (21 additional authors not shown)
Abstract:
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipac…
▽ More
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Stimulated Generation of Magnetrons powered below the Self-Excitation Threshold Voltage
Authors:
G. Kazakevich,
R. P. Johnson,
T. Khabiboulline,
V. Lebedev,
G. Romanov,
V. Yakovlev
Abstract:
Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, so…
▽ More
Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time. The developed technique, its experimental verification and a brief explanation of the kinetic model substantiating the technique are presented and discussed in this article.
△ Less
Submitted 11 May, 2019;
originally announced May 2019.
-
Low RF power plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities
Authors:
P. Berrutti,
B. Giaccone,
M. Martinello,
A. Grassellino,
T. Khabiboulline,
M. Doleans,
S. Kim,
D. Gonnella,
G. Lanza,
M. Ross
Abstract:
Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established…
▽ More
Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.
△ Less
Submitted 8 February, 2019;
originally announced February 2019.
-
Commissioning And First Results From The Fermilab Cryomodule Test Stand
Authors:
E. R. Harms,
M. Awida,
C. Baffes,
K. Carlson,
S. Chandrasekaran,
B. Chase,
E. Cullerton,
J. Edelen,
J. Einstein-Curtis,
C. Ginsburg,
A. Grassellino,
B. Hansen,
J. Holzbauer,
S. Kazakov,
T. Khabiboulline,
M. Kucera,
J. Leibfritz,
A. Lunin,
D. McDowell,
M. McGee,
D. Nicklaus,
D. Orris,
J. Ozelis,
J. Patrick,
T. Petersen
, et al. (12 additional authors not shown)
Abstract:
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overv…
▽ More
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.
△ Less
Submitted 7 May, 2018;
originally announced May 2018.
-
Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun
Authors:
O. Mohsen,
I. Gonin,
R. Kephart,
T. Khabiboulline,
P. Piot,
N. Solyak,
J. C. Thangaraj,
V. Yakovlev
Abstract:
High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\sim$ 300 kW ave…
▽ More
High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\sim$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.
△ Less
Submitted 5 January, 2018;
originally announced January 2018.
-
Three-dimensional single gyroid photonic crystals with a mid-infrared bandgap
Authors:
Siying Peng,
Runyu Zhang,
Valerian H. Chen,
Emil T. Khabiboulline,
Paul Braun,
Harry A. Atwater
Abstract:
A gyroid structure is a distinct morphology that is triply periodic and consists of minimal isosurfaces containing no straight lines. We have designed and synthesized amorphous silicon (a-Si) mid-infrared gyroid photonic crystals that exhibit a complete bandgap in infrared spectroscopy measurements. Photonic crystals were synthesized by deposition of a-Si/Al2O3 coatings onto a sacrificial polymer…
▽ More
A gyroid structure is a distinct morphology that is triply periodic and consists of minimal isosurfaces containing no straight lines. We have designed and synthesized amorphous silicon (a-Si) mid-infrared gyroid photonic crystals that exhibit a complete bandgap in infrared spectroscopy measurements. Photonic crystals were synthesized by deposition of a-Si/Al2O3 coatings onto a sacrificial polymer scaffold defined by two-photon lithography. We observed a 100% reflectance at 7.5 \mum for single gyroids with a unit cell size of 4.5 \mum, in agreement with the photonic bandgap position predicted from full-wave electromagnetic simulations, whereas the observed reflection peak shifted to 8 um for a 5.5 \mum unit cell size. This approach represents a simulation-fabrication-characterization platform to realize three-dimensional gyroid photonic crystals with well-defined dimensions in real space and tailored properties in momentum space.
△ Less
Submitted 13 April, 2016;
originally announced April 2016.
-
Nitrogen and argon doping of niobium for superconducting radio frequency cavities: a pathway to highly efficient accelerating structures
Authors:
A. Grassellino,
A. Romanenko,
O. Melnychuk,
Y. Trenikhina,
A. Crawford,
A. Rowe,
M. Wong,
D. Sergatskov,
T. Khabiboulline,
F. Barkov
Abstract:
We report a surface treatment that systematically improves the quality factor of niobium radio frequency cavities beyond the expected limit for niobium. A combination of annealing in a partial pressure of nitrogen or argon gas and subsequent electropolishing of the niobium cavity surface leads to unprecedented low values of the microwave surface resistance, and an improvement in the efficiency of…
▽ More
We report a surface treatment that systematically improves the quality factor of niobium radio frequency cavities beyond the expected limit for niobium. A combination of annealing in a partial pressure of nitrogen or argon gas and subsequent electropolishing of the niobium cavity surface leads to unprecedented low values of the microwave surface resistance, and an improvement in the efficiency of the accelerating structures up to a factor of 3, reducing the cryogenic load of superconducting cavities for both pulsed and continuous duty cycles. The field dependence of the surface resistance is reversed compared to standardly treated niobium.
△ Less
Submitted 24 June, 2013; v1 submitted 2 June, 2013;
originally announced June 2013.
-
High Gradient Tests of the Fermilab SSR1 Cavity
Authors:
T. Khabiboulline,
C. M. Ginsburg,
I. Gonin,
R. Madrak,
O. Melnychuk,
J. Ozelis,
Y. Pischalnikov,
L. Ristori,
A. Rowe,
D. A. Sergatskov,
A. Sukhanov,
I. Terechkine,
R. Wagner,
R. Webber,
V. Yakovlev
Abstract:
In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavi…
▽ More
In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavities were manufactured in the industry and on-going cold test results will be presented in this poster.
△ Less
Submitted 23 January, 2013;
originally announced January 2013.
-
First high power pulsed tests of a dressed 325 MHz superconducting single spoke resonator at Fermilab
Authors:
R. Madrak,
J. Branlard,
B. Chase,
C. Darve,
P. Joireman,
T. Khabiboulline,
A. Mukherjee,
T. Nicol,
E. Peoples-Evans,
D. Peterson,
Y. Pischalnikov,
L. Ristori,
W. Schappert,
D. Sergatskov,
W. Soyars,
J. Steimel,
I. Terechkine,
V. Tupikov,
R. Wagner,
R. C. Webber,
D. Wildman
Abstract:
In the recently commissioned superconducting RF cavity test facility at Fermilab (SCTF), a 325 MHz, β=0.22 superconducting single-spoke resonator (SSR1) has been tested for the first time with its input power coupler. Previously, this cavity had been tested CW with a low power, high Qext test coupler; first as a bare cavity in the Fermilab Vertical Test Stand and then fully dressed in the SCTF. Fo…
▽ More
In the recently commissioned superconducting RF cavity test facility at Fermilab (SCTF), a 325 MHz, β=0.22 superconducting single-spoke resonator (SSR1) has been tested for the first time with its input power coupler. Previously, this cavity had been tested CW with a low power, high Qext test coupler; first as a bare cavity in the Fermilab Vertical Test Stand and then fully dressed in the SCTF. For the tests described here, the design input coupler with Qext ~ 106 was used. Pulsed power was provided by a Toshiba E3740A 2.5 MW klystron.
△ Less
Submitted 17 February, 2012;
originally announced February 2012.
-
CW RF system of the Project-X accelerator front end
Authors:
T. Khabiboulline,
S. Barbanotti,
I. Gonin,
N. Solyak,
I. Terechkine,
V. Yakovlev
Abstract:
Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 MeV to 160 MeV. SC Single Spoke Resonators (SSR) will be used in the linac, because Fermilab already successfully developed and tested a SSR for beta=0.21. Two manufactured cavities achieve 2.5 times more than design accel…
▽ More
Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 MeV to 160 MeV. SC Single Spoke Resonators (SSR) will be used in the linac, because Fermilab already successfully developed and tested a SSR for beta=0.21. Two manufactured cavities achieve 2.5 times more than design accelerating gradients. One of these cavities completely dressed, e.g. welded to helium vessel with integrated slow and fast tuners, and tested in CW regime. Successful tests of beta=0.21 SSR give us a confidence to use this type of cavity for low beta (0.117) and for high-beta (0.4) as well. Both types of these cavities are under development. In present report the basic constrains, parameters, electromagnetic and mechanical design for all the three SSR cavities, and first test results of beta=0.21 SSR are presented.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
First high gradient test results of a dressed 325 MHz superconducting single spoke resonator at Fermilab
Authors:
R. C. Webber,
T. Khabiboulline,
R. Madrak,
T. Nicol,
L. Ristori,
W. Soyars,
R. Wagner
Abstract:
A new superconducting RF cavity test facility has been commissioned at Fermilab in conjunction with first tests of a 325 MHz, β = 0.22 superconducting single-spoke cavity dressed with a helium jacket and prototype tuner. The facility is described and results of full gradient, CW cavity tests with a high Qext drive coupler are reported. Sensitivities to Q disease and externally applied magnetic fie…
▽ More
A new superconducting RF cavity test facility has been commissioned at Fermilab in conjunction with first tests of a 325 MHz, β = 0.22 superconducting single-spoke cavity dressed with a helium jacket and prototype tuner. The facility is described and results of full gradient, CW cavity tests with a high Qext drive coupler are reported. Sensitivities to Q disease and externally applied magnetic fields were investigated. Results are compared to bare cavity results obtained prior to hydrogen degassing and welding into the helium jacket.
△ Less
Submitted 7 February, 2012;
originally announced February 2012.
-
Experiences with the Fermilab HINS 325 MHz RFQ
Authors:
R. C. Webber,
T. Khabiboulline,
R. Madrak,
G. Romanov,
V. Scarpine,
J. Steimel,
D. Wildman
Abstract:
The Fermilab High Intensity Neutrino Source program has built and commissioned a pulsed 325 MHz RFQ. The RFQ has successfully accelerated a proton beam at the RFQ design RF power. Experiences encountered during RFQ conditioning, including the symptoms and cause of a run-away detuning problem, and the first beam results are first reported.
The Fermilab High Intensity Neutrino Source program has built and commissioned a pulsed 325 MHz RFQ. The RFQ has successfully accelerated a proton beam at the RFQ design RF power. Experiences encountered during RFQ conditioning, including the symptoms and cause of a run-away detuning problem, and the first beam results are first reported.
△ Less
Submitted 7 February, 2012;
originally announced February 2012.
-
Higher Order Modes in Third Harmonic Cavities for XFEL/FLASH
Authors:
I. R. R. Shinton,
N. Baboi,
N. Eddy,
T. Flisgen,
H. W. Glock,
R. M. Jones,
N. Juntong,
T. N. Khabiboulline,
U van Rienen,
P. Zhang
Abstract:
We analyse higher order modes in the 3.9 GHz bunch shaping cavities recently installed in the FLASH facility at DESY. We report on recent experimental results on the frequency spectrum from probe based measurements made at CMTB at DESY. These are compared to those predicted by finite difference and finite element computer codes. This study is focused mainly on the dipole component of the multi-pol…
▽ More
We analyse higher order modes in the 3.9 GHz bunch shaping cavities recently installed in the FLASH facility at DESY. We report on recent experimental results on the frequency spectrum from probe based measurements made at CMTB at DESY. These are compared to those predicted by finite difference and finite element computer codes. This study is focused mainly on the dipole component of the multi-pole expansion of the wakefield.. The modes are readily identifiable as single-cavity modes provided the frequencies of these modes are below the cut-off of the inter-connecting beam pipes. The modes above cut-off are coupled to the 4 cavities and are distinct from single cavity modes
△ Less
Submitted 1 June, 2010;
originally announced June 2010.