Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
L. Burmeister,
F. Casadei,
E. Cipelli,
J. Burkhart,
L. Canonica,
J. Dohm,
F. Dominsky,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
E. Fascione,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
D. Hauff
, et al. (37 additional authors not shown)
Abstract:
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observa…
▽ More
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $γ$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.
△ Less
Submitted 4 June, 2025;
originally announced June 2025.
-
Sub-keV Electron Recoil Calibration for Cryogenic Detectors using a Novel X-ray Fluorescence Source
Authors:
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
V. M. Ghete,
M. Giammei,
C. Goupy,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoene…
▽ More
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoenergetic X-rays from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in detectors based on transition edge sensors (TES).
△ Less
Submitted 23 May, 2025;
originally announced May 2025.
-
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
Authors:
H. Abele,
P. Ajello,
A. Armatol,
B. Arnold,
J. Billard,
E. Bossio,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
J. Colas,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
C. Doutre,
A. Erhart,
S. Fichtinger,
M. Friedl,
P. Garin,
R. Gergen,
C. Goupy,
D. Hainz,
D. Hauff,
E. Jericha
, et al. (29 additional authors not shown)
Abstract:
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined…
▽ More
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $γ$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $γ$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.
△ Less
Submitted 21 May, 2025;
originally announced May 2025.
-
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
Authors:
G. Angloher,
S. Banik,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
E. R. Cipelli,
S. Di Lorenzo,
J. Dohm,
F. Dominsky,
L. Einfalt,
A. Erb,
E. Fascione,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (32 additional authors not shown)
Abstract:
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses rangin…
▽ More
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new generation of experiments is being developed. The upcoming upgrade of the CRESST experiment will incorporate $\mathcal{O}$(100) detectors with different masses ranging from $\sim$2g to $\sim$24g, aiming to achieve unprecedented sensitivity to sub-GeV dark matter particles with a focus on spin-independent dark matter-nucleus scattering. This paper presents a comprehensive analysis of the planned upgrade, detailed experimental strategies, anticipated challenges, and projected sensitivities. Approaches to address and mitigate low-energy excess backgrounds $-$ a key limitation in previous and current sub-GeV dark matter searches $-$ are also discussed. In addition, a long-term roadmap for the next decade is outlined, including other potential scientific applications.
△ Less
Submitted 2 May, 2025;
originally announced May 2025.
-
Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors
Authors:
Daniel Baxter,
Rouven Essig,
Yonit Hochberg,
Margarita Kaznacheeva,
Belina von Krosigk,
Florian Reindl,
Roger K. Romani,
Felix Wagner
Abstract:
Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others…
▽ More
Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids. Their understanding is essential for interpreting particle interactions at and below the eV-scale.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
Authors:
The NUCLEUS collaboration,
A. Wex,
J. Rothe,
L. Peters,
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
L. Canonica,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
A. Garai
, et al. (42 additional authors not shown)
Abstract:
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a…
▽ More
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
△ Less
Submitted 7 April, 2025; v1 submitted 8 January, 2025;
originally announced January 2025.
-
Scintillating low-temperature calorimeters for direct dark matter search
Authors:
Margarita Kaznacheeva,
Karoline Schäffner
Abstract:
The lack of an unambiguous signal for thermally produced dark matter particles in direct detection, indirect detection, and collider searches calls for broadening the search strategies by probing a wider range of dark matter masses with different detection techniques. One of the most common approaches is to search for nuclear recoils induced by dark matter particles scattering off the target mater…
▽ More
The lack of an unambiguous signal for thermally produced dark matter particles in direct detection, indirect detection, and collider searches calls for broadening the search strategies by probing a wider range of dark matter masses with different detection techniques. One of the most common approaches is to search for nuclear recoils induced by dark matter particles scattering off the target material's nuclei. Low-temperature detectors have proven to provide the required performance to probe dark matter masses from 100 MeV/c$^2$ to 100 GeV/c$^2$ via this channel. Using scintillation light as an ancillary channel is a powerful tool for particle identification and background suppression at the keV-recoil energy scale. The CRESST-III experiment, employing scintillating cryogenic detectors with highly sensitive transition edge sensors and multi-target absorber crystals, achieved unprecedented sensitivities to explore sub-GeV dark matter masses. COSINUS, instead, is a new experiment exploiting the phonon-light technique using sodium iodide crystals with the scope to clarify the long-lasting dark matter claim of the DAMA/LIBRA collaboration. This article reviews the principle of scintillating low-temperature calorimeters with emphasis on the benefits and challenges of this technique for direct dark matter searches in light of the current status and future developments.
△ Less
Submitted 6 September, 2024; v1 submitted 3 June, 2024;
originally announced June 2024.
-
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils i…
▽ More
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
Optimal operation of cryogenic calorimeters through deep reinforcement learning
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an…
▽ More
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.
△ Less
Submitted 25 November, 2023;
originally announced November 2023.
-
Detector development for the CRESST experiment
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of t…
▽ More
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
Authors:
A. Erhart,
V. Wagner,
A. Wex,
C. Goupy,
D. Lhuillier,
E. Namuth,
C. Nones,
R. Rogly,
V. Savu,
M. Schwarz,
R. Strauss,
M. Vivier,
H. Abele,
G. Angloher,
A. Bento,
J. Burkhart,
L. Canonica,
F. Cappella,
N. Casali,
R. Cerulli,
A. Cruciani,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer
, et al. (37 additional authors not shown)
Abstract:
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we…
▽ More
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Light Dark Matter Search Using a Diamond Cryogenic Detector
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (34 additional authors not shown)
Abstract:
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. W…
▽ More
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 9 January, 2025; v1 submitted 19 July, 2023;
originally announced July 2023.
-
Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff
, et al. (36 additional authors not shown)
Abstract:
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Re…
▽ More
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.
△ Less
Submitted 25 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
Authors:
The NUCLEUS collaboration,
C. Goupy,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friendl,
A. Garai,
V. M. Ghete,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva,
A. Kinast
, et al. (37 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for…
▽ More
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.
△ Less
Submitted 10 November, 2022; v1 submitted 8 November, 2022;
originally announced November 2022.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
Towards an automated data cleaning with deep learning in CRESST
Authors:
G. Angloher,
S. Banik,
D. Bartolot,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta
, et al. (40 additional authors not shown)
Abstract:
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. Wit…
▽ More
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.
△ Less
Submitted 7 January, 2023; v1 submitted 1 November, 2022;
originally announced November 2022.
-
Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (36 additional authors not shown)
Abstract:
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-b…
▽ More
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.
△ Less
Submitted 24 January, 2023; v1 submitted 22 August, 2022;
originally announced September 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Development of a compact muon veto for the NUCLEUS experiment
Authors:
V. Wagner,
R. Rogly,
A. Erhart,
V. Savu,
C. Goupy,
D. Lhuillier,
M. Vivier,
L. Klinkenberg,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. del Castello,
M. Friedl,
A. Garai,
V. M. Ghete,
V. Guidi,
D. Hauff,
M. Kaznacheeva,
A. Kinast
, et al. (30 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spati…
▽ More
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spatial requirements to fit the constraints given by the experimental site and to minimize the induced detector dead-time. We developed highly efficient and compact muon veto modules based on plastic scintillators equipped with wavelength shifting fibers and silicon photo multipliers to collect and detect the scintillation light. In this paper, we present the full characterization of a prototype module with different light read-out configurations. We conclude that an efficient and compact muon veto system can be built for the NUCLEUS experiment from a cube assembly of the developed modules. Simulations show that an efficiency for muon identification of >99 % and an associated rate of 325 Hz is achievable, matching the requirements of the NUCLEUS experiment.
△ Less
Submitted 26 April, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
Probing spin-dependent dark matter interactions with $^6$Li
Authors:
G. Angloher,
G. Benato,
A. Bento,
E. Bertoldo,
A. Bertolini,
R. Breier,
C. Bucci,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of…
▽ More
CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
Calibration of nuclear recoils at the 100 eV scale using neutron capture
Authors:
L. Thulliez,
D. Lhuillier,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
E. Dumonteil,
A. Erhart,
A. Giuliani,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
A. Langenkämper,
T. Lasserre,
A. Letourneau,
O. Litaize,
P. de Marcillac,
S. Marnieros,
T. Materna,
B. Mauri,
E. Mazzucato,
C. Nones,
T. Ortmann
, et al. (12 additional authors not shown)
Abstract:
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear…
▽ More
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear recoils resulting from the $γ$ emission following thermal neutron capture. In particular, several MeV-scale single-$γ$ transitions induce well-defined nuclear recoil peaks in the 100 eV range. Using the FIFRELIN code, complete schemes of $γ$-cascades for various isotopes can be predicted with high accuracy to determine the continuous background of nuclear recoils below the calibration peaks. We present a comprehensive experimental concept for the calibration of CaWO$_4$ and Ge cryogenic detectors at a research reactor. For CaWO$_4$ the simulations show that two nuclear recoil peaks at 112.5 eV and 160.3 eV should be visible above background simply in the spectrum of the cryogenic detector. Then we discuss how the additional tagging for the associated $γ$ increases the sensitivity of the method and extends its application to a wider energy range and to Ge cryogenic detectors.
△ Less
Submitted 23 May, 2021; v1 submitted 27 November, 2020;
originally announced November 2020.
-
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter
Authors:
A. H. Abdelhameed,
G. Angloher,
P. Bauer,
A. Bento,
E. Bertoldo,
R. Breier,
C. Bucci,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
V. M. Ghete,
A. Garai,
P. Gorla,
D. Hauff,
M. Ješkovský,
J. Jochum,
J. Kaizer,
M. Kaznacheeva,
A. Kinast
, et al. (34 additional authors not shown)
Abstract:
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cry…
▽ More
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
△ Less
Submitted 15 December, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.