-
Acceleration of positive muons by a radio-frequency cavity
Authors:
S. Aritome,
K. Futatsukawa,
H. Hara,
K. Hayasaka,
Y. Ibaraki,
T. Ichikawa,
T. Iijima,
H. Iinuma,
Y. Ikedo,
Y. Imai,
K. Inami,
K. Ishida,
S. Kamal,
S. Kamioka,
N. Kawamura,
M. Kimura,
A. Koda,
S. Koji,
K. Kojima,
A. Kondo,
Y. Kondo,
M. Kuzuba,
R. Matsushita,
T. Mibe,
Y. Miyamoto
, et al. (30 additional authors not shown)
Abstract:
Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emitt…
▽ More
Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emittance of the accelerated muons in the horizontal and vertical planes were $0.85 \pm 0.25 ~\rm{(stat.)}~^{+0.22}_{-0.13} ~\rm{(syst.)}~π~$mm$\cdot$mrad and $0.32\pm 0.03~\rm{(stat.)} ^{+0.05}_{-0.02} ~\rm{(syst.)}~π~$mm$\cdot$mrad, respectively. The measured emittance values demonstrated phase space reduction by a factor of $2.0\times 10^2$ (horizontal) and $4.1\times 10^2$ (vertical) allowing good acceleration efficiency. These results pave the way to realize the first-ever muon accelerator for a variety of applications in particle physics, material science, and other fields.
△ Less
Submitted 17 June, 2025; v1 submitted 15 October, 2024;
originally announced October 2024.
-
Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC
Authors:
K. S. Tanaka,
M. Iwasaki,
O. Kamigaito,
S. Kanda,
N. Kawamura,
Y. Matsuda,
T. Mibe,
S. Nishimura,
N. Saito,
N. Sakamoto,
S. Seo,
K. Shimomura,
P. Strasser,
K. Suda,
T. Tanaka,
H. A. Torii,
A. Toyoda,
Y. Ueno,
M. Yoshida
Abstract:
The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will…
▽ More
The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.
△ Less
Submitted 3 January, 2022; v1 submitted 14 April, 2021;
originally announced April 2021.
-
Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms
Authors:
S. Nishimura,
H. A. Torii,
Y. Fukao,
T. U. Ito,
M. Iwasaki,
S. Kanda,
K. Kawagoe,
D. Kawall,
N. Kawamura,
N. Kurosawa,
Y. Matsuda,
T. Mibe,
Y. Miyake,
N. Saito,
K. Sasaki,
Y. Sato,
S. Seo,
P. Strasser,
T. Suehara,
K. S. Tanaka,
T. Tanaka,
J. Tojo,
A. Toyoda,
Y. Ueno,
T. Yamanaka
, et al. (4 additional authors not shown)
Abstract:
As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency swe…
▽ More
As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $ν_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.
△ Less
Submitted 12 February, 2021; v1 submitted 24 July, 2020;
originally announced July 2020.
-
Study of muonium emission from laser-ablated silica aerogel
Authors:
J. Beare,
G. Beer,
J. H. Brewer,
T. Iijima,
K. Ishida,
M. Iwasaki,
S. Kamal,
K. Kanamori,
N. Kawamura,
R. Kitamura,
S. Li,
G. M. Luke,
G. M. Marshall,
T. Mibe,
Y. Miyake,
Y. Oishi,
K. Olchanski,
A. Olin,
M. Otani,
M. A. Rehman,
N. Saito,
Y. Sato,
K. Shimomura,
K. Suzuki,
M. Tabata
, et al. (1 additional authors not shown)
Abstract:
The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some…
▽ More
The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.
△ Less
Submitted 1 September, 2020; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V
Authors:
Taku Ishida,
Eiichi Wakai,
Shunsuke Makimura,
Andrew M. Casella,
Danny J. Edwards,
Ramprashad Prabhakaran,
David J. Senor,
Kavin Ammigan,
Sujit Bidhar,
Patrick G. Hurh,
Frederique Pellemoine,
Christopher J. Densham,
Michael D. Fitton,
Joe M. Bennett,
Dohyun Kim,
Nikolaos Simos,
Masayuki Hagiwara,
Naritoshi Kawamura,
Shin-ichiro Meigo,
Katsuya Yonehara
Abstract:
A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at beam center region with an irradiation temperature around 120 degree C. Tensile tests sh…
▽ More
A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at beam center region with an irradiation temperature around 120 degree C. Tensile tests showed increased hardness and a large decrease in ductility for the dual alpha+beta-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near alpha-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each alpha-phase grain. The beta-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated omega-phase precipitation in an advanced formation stage. The radiation-induced omega-phase transformation in the beta-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less beta-phase.
△ Less
Submitted 30 July, 2020; v1 submitted 24 April, 2020;
originally announced April 2020.
-
New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam
Authors:
S. Kanda,
Y. Fukao,
Y. Ikedo,
K. Ishida,
M. Iwasaki,
D. Kawall,
N. Kawamura,
K. M. Kojima,
N. Kurosawa,
Y. Matsuda,
T. Mibe,
Y. Miyake,
S. Nishimura,
N. Saito,
Y. Sato,
S. Seo,
K. Shimomura,
P. Strasser,
K. S. Tanaka,
T. Tanaka,
H. A. Torii,
A. Toyoda,
Y. Ueno
Abstract:
A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The…
▽ More
A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of $ν_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.
△ Less
Submitted 2 March, 2021; v1 submitted 13 April, 2020;
originally announced April 2020.
-
Compact buncher cavity for muons accelerated by a radio-frequency quadrupole
Authors:
M. Otani,
Y. Sue,
K. Futatsukawa,
T. Iijima,
H. Iinuma,
N. Kawamura,
R. Kitamura,
Y. Kondo,
T. Morishita,
Y. Nakazawa,
H. Yasuda,
M. Yotsuzuka,
N. Saito,
T. Yamazaki
Abstract:
A buncher cavity has been developed for the muons accelerated by a radio-frequency quadrupole linac (RFQ). The buncher cavity is designed for $β=v/c=0.04$ at an operational frequency of 324 MHz. It employs a double-gap structure operated in the TEM mode for the required effective voltage with compact dimensions, in order to account for the limited space of the experiment. The measured resonant fre…
▽ More
A buncher cavity has been developed for the muons accelerated by a radio-frequency quadrupole linac (RFQ). The buncher cavity is designed for $β=v/c=0.04$ at an operational frequency of 324 MHz. It employs a double-gap structure operated in the TEM mode for the required effective voltage with compact dimensions, in order to account for the limited space of the experiment. The measured resonant frequency and unloaded quality factor are 323.95 MHz and $3.06\times10^3$, respectively. The buncher cavity was successfully operated for longitudinal bunch size measurement of the muons accelerated by the RFQ.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment
Authors:
M. Abe,
S. Bae,
G. Beer,
G. Bunce,
H. Choi,
S. Choi,
M. Chung,
W. da Silva,
S. Eidelman,
M. Finger,
Y. Fukao,
T. Fukuyama,
S. Haciomeroglu,
K. Hasegawa,
K. Hayasaka,
N. Hayashizaki,
H. Hisamatsu,
T. Iijima,
H. Iinuma,
K. Inami,
H. Ikeda,
M. Ikeno,
K. Ishida,
T. Itahashi,
M. Iwasaki
, et al. (71 additional authors not shown)
Abstract:
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon…
▽ More
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.
△ Less
Submitted 10 March, 2019; v1 submitted 10 January, 2019;
originally announced January 2019.
-
First muon acceleration using a radio frequency accelerator
Authors:
S. Bae,
H. Choi,
S. Choi,
Y. Fukao,
K. Futatsukawa,
K. Hasegawa,
T. Iijima,
H. Iinuma,
K. Ishida,
N. Kawamura,
B. Kim,
R. Kitamura,
H. S. Ko,
Y. Kondo,
S. Li,
T. Mibe,
Y. Miyake,
T. Morishita,
Y. Nakazawa,
M. Otani,
G. P. Razuvaev,
N. Saito,
K. Shimomura,
Y. Sue,
E. Won
, et al. (1 additional authors not shown)
Abstract:
Muons have been accelerated by using a radio frequency accelerator for the first time. Negative muonium atoms (Mu$^-$), which are bound states of positive muons ($μ^+$) and two electrons, are generated from $μ^+$'s through the electron capture process in an aluminum degrader. The generated Mu$^-$'s are initially electrostatically accelerated and injected into a radio frequency quadrupole linac (RF…
▽ More
Muons have been accelerated by using a radio frequency accelerator for the first time. Negative muonium atoms (Mu$^-$), which are bound states of positive muons ($μ^+$) and two electrons, are generated from $μ^+$'s through the electron capture process in an aluminum degrader. The generated Mu$^-$'s are initially electrostatically accelerated and injected into a radio frequency quadrupole linac (RFQ). In the RFQ, the Mu$^-$'s are accelerated to 89 keV. The accelerated Mu$^-$'s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.
△ Less
Submitted 21 March, 2018;
originally announced March 2018.
-
Enhancement of muonium emission rate from silica aerogel with a laser ablated surface
Authors:
G. A. Beer,
Y. Fujiwara,
S. Hirota,
K. Ishida,
M. Iwasaki,
S. Kanda,
H. Kawai,
N. Kawamura,
R. Kitamura,
S. Lee,
W. Lee G. M. Marshall,
T. Mibe,
Y. Miyake,
S. Okada,
K. Olchanski,
A. Olin,
Y. Oishi,
H. Onishi,
M. Otani,
N. Saito,
K. Shimomura,
P. Strasser,
M. Tabata,
D. Tomono,
K. Ueno
, et al. (2 additional authors not shown)
Abstract:
Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.
Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.
△ Less
Submitted 30 July, 2014;
originally announced July 2014.
-
Measurement of muonium emission from silica aerogel
Authors:
P. Bakule,
G. A. Beer,
D. Contreras,
M. Esashi,
Y. Fujiwara,
Y. Fukao,
S. Hirota,
H. Iinuma,
K. Ishida,
M. Iwasaki,
T. Kakurai,
S. Kanda,
H. Kawai,
N. Kawamura,
G. M. Marshall,
H. Masuda,
Y. Matsuda,
T. Mibe,
Y. Miyake,
S. Okada,
K. Olchanski,
A. Olin,
H. Onishi,
N. Saito,
K. Shimomura
, et al. (6 additional authors not shown)
Abstract:
Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expect…
▽ More
Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.
△ Less
Submitted 17 June, 2013;
originally announced June 2013.
-
J-PARC MUSE H-line optimization for the g-2 and MuHFS experiments
Authors:
A. Toyoda,
Y. Fujiwara,
Y. Fukao,
O. Kamigaito,
N. Kawamura,
Y. Matsuda,
T. Mibe,
T. Ogitsu,
N. Saito,
K. Sasaki,
K. Shimomura,
M. Sugano,
K. Tanaka,
D. Tomono,
H. A. Torii
Abstract:
Significant deviation of the anomalous magnetic moment value (g-2) observed by the muon g-2 experiment should be confirmed by the other experiment. This value is experimentally determined by frequency difference observed by the g-2/EDM experiment and muon magnetic moment observed by the muonium hyperfine splitting experiment (MuHFS). Both two experiments are planned to be performed at H-line of th…
▽ More
Significant deviation of the anomalous magnetic moment value (g-2) observed by the muon g-2 experiment should be confirmed by the other experiment. This value is experimentally determined by frequency difference observed by the g-2/EDM experiment and muon magnetic moment observed by the muonium hyperfine splitting experiment (MuHFS). Both two experiments are planned to be performed at H-line of the J-PARC/MUSE under construction. We optimized the beamline layout for each experiment with G4beamline. For both experiments, statistics is the most important, thus beamline transmission efficiency should be maximized. Especially for the g-2, the purpose of the present effort is to compromise between small beam size and small leakage field. For the MuHFS, it is crucial to minimize leakage field at around final focus position, and to get all stopped muons within good field region of MuHFS magnet. Conceptual design of the several final focusing systems will be presented. contribution (or invited paper) to NUFACT 11, XIIIth International Workshop on Neutrino Factories, Super beams and Beta beams, 1-6 August 2011, CERN and University of Geneva
△ Less
Submitted 5 October, 2011;
originally announced October 2011.