-
Rotational-hyperfine cooling of $^{205}$TlF in a cryogenic beam
Authors:
Olivier Grasdijk,
David DeMille,
Jakob Kastelic,
David Kawall,
Steve Lamoreaux,
Oskari Timgren,
Konrad Wenz,
Tanya Zelevinsky
Abstract:
The aim of CeNTREX (Cold Molecule Nuclear Time-Reversal Experiment) is to search for time-reversal symmetry violation in the thallium nucleus, by measuring the Schiff moment of $^{205}$Tl in the polar molecule thallium fluoride (TlF). CeNTREX uses a cryogenic beam of TlF with a rotational temperature of 6.3(2) K. This results in population spread over dozens of rotational and hyperfine sublevels o…
▽ More
The aim of CeNTREX (Cold Molecule Nuclear Time-Reversal Experiment) is to search for time-reversal symmetry violation in the thallium nucleus, by measuring the Schiff moment of $^{205}$Tl in the polar molecule thallium fluoride (TlF). CeNTREX uses a cryogenic beam of TlF with a rotational temperature of 6.3(2) K. This results in population spread over dozens of rotational and hyperfine sublevels of TlF, while only a single level is useful for the Schiff moment measurement. Here we present a protocol for cooling the rotational and hyperfine degrees of freedom in the CeNTREX beam, transferring the majority of the Boltzmann distribution into a single rotational and hyperfine sublevel by using a single ultraviolet laser and a pair of microwave beams. We achieve a factor of $20.1(4)$ gain in the population of the $J=0$, $F=0$ hyperfine sublevel of the TlF ground state.
△ Less
Submitted 17 June, 2025; v1 submitted 9 January, 2025;
originally announced January 2025.
-
Workshop on a future muon program at FNAL
Authors:
S. Corrodi,
Y. Oksuzian,
A. Edmonds,
J. Miller,
H. N. Tran,
R. Bonventre,
D. N. Brown,
F. Meot,
V. Singh,
Y. Kolomensky,
S. Tripathy,
L. Borrel,
M. Bub,
B. Echenard,
D. G. Hitlin,
H. Jafree,
S. Middleton,
R. Plestid,
F. C. Porter,
R. Y. Zhu,
L. Bottura,
E. Pinsard,
A. M. Teixeira,
C. Carelli,
D. Ambrose
, et al. (68 additional authors not shown)
Abstract:
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e…
▽ More
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
High-Accuracy Absolute Magnetometry with Application to the Fermilab Muon $g-2$ Experiment
Authors:
D. Flay,
D. Kawall,
T. Chupp,
S. Corrodi,
M. Farooq,
M. Fertl,
J. George,
J. Grange,
R. Hong,
R. Osofsky,
S. Ramachandran,
E. Swanson,
P. Winter
Abstract:
We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The $B$-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification…
▽ More
We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The $B$-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at $B = 1.45$\,T but can be modified for a range exceeding 1--3\,T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.
△ Less
Submitted 22 December, 2021; v1 submitted 18 September, 2021;
originally announced September 2021.
-
The fast non-ferric kicker system for the Muon $g-2$ Experiment at Fermilab
Authors:
A. P. Schreckenberger,
D. Allspach,
D. Barak,
J. Bohn,
C. Bradford,
D. Cauz,
S. P. Chang,
A. Chapelain,
S. Chappa,
S. Charity,
R. Chislett,
J. Esquivel,
C. Ferrari,
A. Fioretti,
C. Gabbanini,
M. D. Galati,
L. Gibbons,
J. L. Holzbauer,
M. Incagli,
C. Jensen,
J. Kaspar,
D. Kawall,
A. Keshavarzi,
D. S. Kessler,
B. Kiburg
, et al. (17 additional authors not shown)
Abstract:
We describe the installation, commissioning, and characterization of the new injection kicker system in the Muon $g-2$ Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system…
▽ More
We describe the installation, commissioning, and characterization of the new injection kicker system in the Muon $g-2$ Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon $g-2$'s predecessor experiment, and we present those details in this manuscript.
△ Less
Submitted 3 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Systematic and Statistical Uncertainties of the Hilbert-Transform Based High-precision FID Frequency Extraction Method
Authors:
Ran Hong,
Simon Corrodi,
Saskia Charity,
Stefan Baessler,
Jason Bono,
Timothy Chupp,
Martin Fertl,
David Flay,
Alejandro Garcia,
Jimin George,
Kevin Louis Giovanetti,
Timothy Gorringe,
Joseph Grange,
Kyun Woo Hong,
David Kawall,
Brendan Kiburg,
Bingzhi Li,
Rachel Osofsky,
Dinko Pocanic,
Suvarna Ramachandran,
Matthias Smith,
Herbert Erik Swanson,
Alec Tewsley-Booth,
Peter Winter,
Tianyu Yang
, et al. (1 additional authors not shown)
Abstract:
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation…
▽ More
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $χ^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $χ^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.
△ Less
Submitted 27 January, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
CeNTREX: A new search for time-reversal symmetry violation in the $^{205}$Tl nucleus
Authors:
Olivier Grasdijk,
Oskari Timgren,
Jakob Kastelic,
Trevor Wright,
Steve Lamoreaux,
David DeMille,
Konrad Wenz,
Michael Aitken,
Tanya Zelevinsky,
Tristan Winick,
David Kawall
Abstract:
The Cold molecule Nuclear Time-Reversal EXperiment (CeNTREX) is a new effort aiming for a significant increase in sensitivity over the best present upper bounds on the strength of hadronic time reversal ($T$) violating fundamental interactions. The experimental signature will be shifts in nuclear magnetic resonance frequencies of $^{205}$Tl in electrically-polarized thallium fluoride (TlF) molecul…
▽ More
The Cold molecule Nuclear Time-Reversal EXperiment (CeNTREX) is a new effort aiming for a significant increase in sensitivity over the best present upper bounds on the strength of hadronic time reversal ($T$) violating fundamental interactions. The experimental signature will be shifts in nuclear magnetic resonance frequencies of $^{205}$Tl in electrically-polarized thallium fluoride (TlF) molecules. Here we describe the motivation for studying these $T$-violating interactions and for using TlF to do so. To achieve higher sensitivity than earlier searches for $T$-violation in TlF, CeNTREX uses a cryogenic molecular beam source, optical state preparation and detection, and modern methods of coherent quantum state manipulation. Details of the measurement scheme and the current state of the apparatus are presented, with quantitative measurements of the TlF beam. Finally, the estimated sensitivity and methods to control systematic errors are discussed.
△ Less
Submitted 30 November, 2020; v1 submitted 3 October, 2020;
originally announced October 2020.
-
Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms
Authors:
S. Nishimura,
H. A. Torii,
Y. Fukao,
T. U. Ito,
M. Iwasaki,
S. Kanda,
K. Kawagoe,
D. Kawall,
N. Kawamura,
N. Kurosawa,
Y. Matsuda,
T. Mibe,
Y. Miyake,
N. Saito,
K. Sasaki,
Y. Sato,
S. Seo,
P. Strasser,
T. Suehara,
K. S. Tanaka,
T. Tanaka,
J. Tojo,
A. Toyoda,
Y. Ueno,
T. Yamanaka
, et al. (4 additional authors not shown)
Abstract:
As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency swe…
▽ More
As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $ν_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.
△ Less
Submitted 12 February, 2021; v1 submitted 24 July, 2020;
originally announced July 2020.
-
New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam
Authors:
S. Kanda,
Y. Fukao,
Y. Ikedo,
K. Ishida,
M. Iwasaki,
D. Kawall,
N. Kawamura,
K. M. Kojima,
N. Kurosawa,
Y. Matsuda,
T. Mibe,
Y. Miyake,
S. Nishimura,
N. Saito,
Y. Sato,
S. Seo,
K. Shimomura,
P. Strasser,
K. S. Tanaka,
T. Tanaka,
H. A. Torii,
A. Toyoda,
Y. Ueno
Abstract:
A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The…
▽ More
A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of $ν_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.
△ Less
Submitted 2 March, 2021; v1 submitted 13 April, 2020;
originally announced April 2020.
-
Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment
Authors:
S. Corrodi,
P. De Lurgio,
D. Flay,
J. Grange,
R. Hong,
D. Kawall,
M. Oberling,
S. Ramachandran,
P. Winter
Abstract:
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_μ$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $ω^{}_a$, and the average magnetic field in terms of the shielded proton Larmor frequency, $ω'^{}_p$. The measurement of $ω'^{}_p$ with a total systematic uncer…
▽ More
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_μ$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $ω^{}_a$, and the average magnetic field in terms of the shielded proton Larmor frequency, $ω'^{}_p$. The measurement of $ω'^{}_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration. A crucial element for the multi-step measurement of $ω'^{}_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.
△ Less
Submitted 10 February, 2021; v1 submitted 13 March, 2020;
originally announced March 2020.
-
A Storage Ring Experiment to Detect a Proton Electric Dipole Moment
Authors:
V. Anastassopoulos,
S. Andrianov,
R. Baartman,
M. Bai,
S. Baessler,
J. Benante,
M. Berz,
M. Blaskiewicz,
T. Bowcock,
K. Brown,
B. Casey,
M. Conte,
J. Crnkovic,
G. Fanourakis,
A. Fedotov,
P. Fierlinger,
W. Fischer,
M. O. Gaisser,
Y. Giomataris,
M. Grosse-Perdekamp,
G. Guidoboni,
S. Haciomeroglu,
G. Hoffstaetter,
H. Huang,
M. Incagli
, et al. (66 additional authors not shown)
Abstract:
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the…
▽ More
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
High-resolution saturation spectroscopy of singly-ionized iron with a pulsed uv laser
Authors:
M Ascoli,
E E Eyler,
D Kawall,
David DeMille
Abstract:
We describe the design and realization of a scheme for uv laser spectroscopy of singly-ionized iron (Fe II) with very high resolution. A buffer-gas cooled laser ablation source is used to provide a plasma close to room temperature with a high density of Fe II. We combine this with a scheme for pulsed-laser saturation spectroscopy to yield sub-Doppler resolution. In a demonstration experiment, we…
▽ More
We describe the design and realization of a scheme for uv laser spectroscopy of singly-ionized iron (Fe II) with very high resolution. A buffer-gas cooled laser ablation source is used to provide a plasma close to room temperature with a high density of Fe II. We combine this with a scheme for pulsed-laser saturation spectroscopy to yield sub-Doppler resolution. In a demonstration experiment, we have examined an Fe II transition near 260 nm, attaining a linewidth of about 250 MHz. The method is well-suited to measuring transition frequencies and hyperfine structure. It could also be used to measure small isotope shifts in isotope-enriched samples.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
Stark-modulation spectroscopy of the B(1)$[^3Π]$ state of PbO
Authors:
D. Kawall,
Y. V. Gurevich,
C. Cheung,
S. Bickman,
Y. Jiang,
D. DeMille
Abstract:
We report detailed spectroscopic measurements of the X(0)$[^3Σ^+]$(v=0) to B(1)$[^3Π]$ (v=5) transition in PbO. Using a Stark-modulated laser absorption technique, we have measured the hyperfine constant of $^{207}$PbO in the B(1) state, as well as B(1)(v=5) rotational constant, X-B isotope shifts, etc. The hyperfine structure of the B(1) state is of interest as a benchmark for calculations of P…
▽ More
We report detailed spectroscopic measurements of the X(0)$[^3Σ^+]$(v=0) to B(1)$[^3Π]$ (v=5) transition in PbO. Using a Stark-modulated laser absorption technique, we have measured the hyperfine constant of $^{207}$PbO in the B(1) state, as well as B(1)(v=5) rotational constant, X-B isotope shifts, etc. The hyperfine structure of the B(1) state is of interest as a benchmark for calculations of PbO electronic structure, related to experiments to search for the electric dipole moment of the electron.
△ Less
Submitted 5 October, 2005; v1 submitted 21 September, 2005;
originally announced September 2005.
-
Proof of principle for a high sensitivity search for the electric dipole moment of the electron using the metastable a(1)[^3Σ^+] state of PbO
Authors:
D. Kawall,
F. Bay,
S. Bickman,
Y. Jiang,
D. DeMille
Abstract:
The metastable a(1)[^3Σ^+] state of PbO has been suggested as a suitable system in which to search for the electric dipole moment (EDM) of the electron. We report here the development of experimental techniques allowing high-sensitivity measurements of Zeeman and Stark effects in this system, similar to those required for an EDM search. We observe Zeeman quantum beats in fluorescence from a vapo…
▽ More
The metastable a(1)[^3Σ^+] state of PbO has been suggested as a suitable system in which to search for the electric dipole moment (EDM) of the electron. We report here the development of experimental techniques allowing high-sensitivity measurements of Zeeman and Stark effects in this system, similar to those required for an EDM search. We observe Zeeman quantum beats in fluorescence from a vapor cell, with shot-noise limited extraction of the quantum beat frequencies, high counting rates, and long coherence times. We argue that improvement in sensitvity to the electron EDM by at least two orders of magnitude appears possible using these techniques.
△ Less
Submitted 30 September, 2003;
originally announced September 2003.