-
Programmable Photonic Unitary Processor Enables Parametrized Differentiable Long-Haul Spatial Division Multiplexed Transmission
Authors:
Mitsumasa Nakajima,
Kohki Shibahara,
Kohei Ikeda,
Akira Kawai,
Masaya Notomi,
Yutaka Miyamoto,
Toshikazu Hashimoto
Abstract:
The explosive growth of global data traffic demands scalable and energy-efficient optical communication systems. Spatial division multiplexing (SDM) using multicore or multimode fibers is a promising solution to overcome the capacity limit of single-mode fibers. However, long-haul SDM transmission faces significant challenges due to modal dispersion, which imposes heavy computational loads on digi…
▽ More
The explosive growth of global data traffic demands scalable and energy-efficient optical communication systems. Spatial division multiplexing (SDM) using multicore or multimode fibers is a promising solution to overcome the capacity limit of single-mode fibers. However, long-haul SDM transmission faces significant challenges due to modal dispersion, which imposes heavy computational loads on digital signal processing (DSP) for signal equalization. Here, we propose parameterized SDM transmission, where programmable photonic unitary processors are installed at intermediate nodes. Instead of relying on conventional digital equalization only on the receiver side, our approach enables direct optimization of the SDM transmission channel itself by the programmable unitary processor, which reduces digital post-processing loads. We introduce a gradient-based optimization algorithm using a differentiable SDM transmission model to determine the optimal unitary transformation. As a key enabler, we first implemented telecom-grade programmable photonic unitary processor, achieving a low-loss (2.1 dB fiber-to-fiber), wideband (full C-band), polarization-independent, and high-fidelity (R2>96% across the C-band) operation. We experimentally demonstrate 1300-km transmission using a three-mode fiber, achieving strong agreement between simulation and experiment. The optimized photonic processor significantly reduces modal dispersion and post-processing complexity. Our results establish a scalable framework for integrating photonic computation into the optical layer, enabling more efficient, high-capacity optical networks.
△ Less
Submitted 22 May, 2025;
originally announced May 2025.
-
Compressive dual-comb spectroscopy
Authors:
Akira Kawai,
Takahiro Kageyama,
Ryoichi Horisaki,
Takuro Ideguchi
Abstract:
Broadband, high resolution and rapid measurement of dual-comb spectroscopy (DCS) generates a large amount of data stream. We numerically demonstrate significant data compression of DCS spectra by using a compressive sensing technique. Our numerical simulation shows a compression rate of more than 100 with 3% error in mole fraction estimation of mid-infrared (MIR) DCS of two molecular species in a…
▽ More
Broadband, high resolution and rapid measurement of dual-comb spectroscopy (DCS) generates a large amount of data stream. We numerically demonstrate significant data compression of DCS spectra by using a compressive sensing technique. Our numerical simulation shows a compression rate of more than 100 with 3% error in mole fraction estimation of mid-infrared (MIR) DCS of two molecular species in a broadband (~30 THz) and high resolution (~115 MHz) condition. We also numerically demonstrate a massively parallel MIR DCS spectrum of 10 different molecular species can be reconstructed with a compression rate of 10.5 with a transmittance error of 0.003 from the original spectrum.
△ Less
Submitted 14 February, 2021; v1 submitted 2 July, 2020;
originally announced July 2020.
-
Time-stretch infrared spectroscopy
Authors:
Akira Kawai,
Kazuki Hasihmoto,
Venkata Ramaiah Badarla,
Takayuki Imamura,
Takuro Ideguchi
Abstract:
Improving spectral acquisition rate of broadband mid-infrared spectroscopy promises further advancements of molecular science and technology. Unlike the pump-probe spectroscopy that requires repeated measurements with different pump-probe delays, continuous spectroscopy running at a high spectral acquisition rate enables transient measurements of rapidly changing non-repeating phenomena or statist…
▽ More
Improving spectral acquisition rate of broadband mid-infrared spectroscopy promises further advancements of molecular science and technology. Unlike the pump-probe spectroscopy that requires repeated measurements with different pump-probe delays, continuous spectroscopy running at a high spectral acquisition rate enables transient measurements of rapidly changing non-repeating phenomena or statistical analysis of a large amount of spectral data acquired within a short time. Recently, Fourier-transform infrared spectrometers (FT-IR) with rapid delay scan mechanisms including dual-comb spectrometers have significantly improved the measurement rate up to ~1 MSpectra/s that is fundamentally limited by the signal-to-noise ratio. Here, we overcome the limit and demonstrate the fastest continuous broadband vibrational spectrometer running at 80 MSpectra/s by implementing wavelength-swept time-stretch spectroscopy technique in the mid-infrared region. Our proof-of-concept experiment of the time-stretch infrared spectroscopy (TS-IR) demonstrates broadband absorption spectroscopy of phenylacetylene from 4.4 to 4.9 μm (2040-2270 cm-1) at a resolution of 15 nm (7.7 cm-1) with a superior signal-to-noise ratio of 85 without averaging and a shot-to-shot fluctuation of 1.3%.
△ Less
Submitted 3 June, 2020; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Complementary Vibrational Spectroscopy
Authors:
Kazuki Hashimoto,
Venkata Ramaiah Badarla,
Akira Kawai,
Takuro Ideguchi
Abstract:
Vibrational spectroscopy, comprised of infrared absorption and Raman scattering spectroscopy, is widely used for label-free optical sensing and imaging in various scientific and industrial fields. The group theory states that the two molecular spectroscopy methods are sensitive to vibrations categorized in different point groups and provide complementary vibrational spectra. Therefore, complete vi…
▽ More
Vibrational spectroscopy, comprised of infrared absorption and Raman scattering spectroscopy, is widely used for label-free optical sensing and imaging in various scientific and industrial fields. The group theory states that the two molecular spectroscopy methods are sensitive to vibrations categorized in different point groups and provide complementary vibrational spectra. Therefore, complete vibrational information cannot be acquired by a single spectroscopic device, which has impeded the full potential of vibrational spectroscopy. Here, we demonstrate simultaneous infrared absorption and Raman scattering spectroscopy that allows us to measure the complete broadband vibrational spectra in the molecular fingerprint region with a single instrument based on an ultrashort pulsed laser. The system is based on dual-modal Fourier-transform spectroscopy enabled by efficient use of nonlinear optical effects. Our proof-of-concept experiment demonstrates rapid, broadband and high spectral resolution measurements of complementary spectra of organic liquids for precise and accurate molecular analysis.
△ Less
Submitted 4 April, 2019;
originally announced April 2019.