-
Polarization-Dependent Disappearance of a Resonance Signal -- Indication for Optical Pumping in a Storage Ring?
Authors:
W. Nörtershäuser,
A. Surzhykov,
R. Sánchez,
B. Botermann,
G. Gwinner,
G. Huber,
S. Karpuk,
T. Kühl,
C. Novotny,
S. Reinhardt,
G. Saathoff,
T. Stöhlker,
A. Wolf
Abstract:
We report on laser spectroscopic measurements on Li$^+$ ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F=\frac{3}{2}) \,\leftrightarrow\,2p\,^3\!P_2\;(F=\frac{5}{2}) \leftrightarrow 2s\,^3\!{S}_1\;(F=\frac{5}{2})$ $Λ$-transition in $^7$Li$^+$ with two superimposed laser beams it was found that the use of circularly polariz…
▽ More
We report on laser spectroscopic measurements on Li$^+$ ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F=\frac{3}{2}) \,\leftrightarrow\,2p\,^3\!P_2\;(F=\frac{5}{2}) \leftrightarrow 2s\,^3\!{S}_1\;(F=\frac{5}{2})$ $Λ$-transition in $^7$Li$^+$ with two superimposed laser beams it was found that the use of circularly polarized light leads to a disappearance of the resonance structure in the fluorescence signal. This can be explained by optical pumping into a dark state of polarized ions. We present a detailed theoretical analysis of this process that supports the interpretation of optical pumping and demonstrates that the polarization induced by the laser light must then be at least partially maintained during the round trip of the ions in the storage ring. Such polarized ion beams in storage rings will provide opportunities for new experiments, especially on parity violation.
△ Less
Submitted 9 February, 2021; v1 submitted 9 November, 2020;
originally announced November 2020.
-
Measurement of the Permanent Electric Dipole Moment of the $^{129}$Xe Atom
Authors:
F. Allmendinger,
I. Engin,
W. Heil,
S. Karpuk,
H. -J. Krause,
B. Niederländer,
A. Offenhäusser,
M. Repetto,
U. Schmidt,
S. Zimmer
Abstract:
We report on a new measurement of the CP-violating permanent Electric Dipole Moment (EDM) of the neutral $^{129}$Xe atom. Our experimental approach is based on the detection of the free precession of co-located nuclear spin-polarized $^3$He and $^{129}$Xe samples. The EDM measurement sensitivity benefits strongly from long spin coherence times of several hours achieved in diluted gases and homogen…
▽ More
We report on a new measurement of the CP-violating permanent Electric Dipole Moment (EDM) of the neutral $^{129}$Xe atom. Our experimental approach is based on the detection of the free precession of co-located nuclear spin-polarized $^3$He and $^{129}$Xe samples. The EDM measurement sensitivity benefits strongly from long spin coherence times of several hours achieved in diluted gases and homogeneous weak magnetic fields of about 400~nT. A finite EDM is indicated by a change in the precession frequency, as an electric field is periodically reversed with respect to the magnetic guiding field. Our result, $\left(-4.7\pm6.4\right)\cdot 10^{-28}$ ecm, is consistent with zero and is used to place a new upper limit on the $^{129}$Xe EDM: $|d_\text{Xe}|<1.5 \cdot 10^{-27}$ ecm (95% C.L.). We also discuss the implications of this result for various CP-violating observables as they relate to theories of physics beyond the standard model.
△ Less
Submitted 12 August, 2019; v1 submitted 28 April, 2019;
originally announced April 2019.
-
Upgrade of the ultracold neutron source at the pulsed reactor TRIGA Mainz
Authors:
Jan Kahlenberg,
Dieter Ries,
Kim Ulrike Ross,
Christian Siemensen,
Marcus Beck,
Christopher Geppert,
Werner Heil,
Nicolas Hild,
Jan Karch,
Sergei Karpuk,
Fabian Kories,
Matthias Kretschmer,
Bernhard Lauss,
Tobias Reich,
Yuri Sobolev,
Norbert Trautmann
Abstract:
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the th…
▽ More
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the thermal bridge and the converter cup. The UCN yield was measured in a `standard' UCN storage bottle (stainless steel) with a volume of 32 litres outside the biological shield at the experimental area yielding UCN densities of 8.5 /cm$^3$; an increase by a factor of 3.5 compared to the former setup. The measured UCN storage curve is in good agreement with the predictions from a Monte Carlo simulation developed to model the source. The growth and formation of the solid deuterium converter during freeze-out are affected by the ortho/para ratio of the H$_2$ premoderator.
△ Less
Submitted 9 November, 2017; v1 submitted 23 June, 2017;
originally announced June 2017.
-
Comparison of ultracold neutron sources for fundamental physics measurements
Authors:
G. Bison,
M. Daum,
K. Kirch,
B. Lauss,
D. Ries,
P. Schmidt-Wellenburg,
G. Zsigmond,
T. Brenner,
P. Geltenbort,
T. Jenke,
O. Zimmer,
M. Beck,
W. Heil,
J. Kahlenberg,
J. Karch,
K. Ross,
K. Eberhardt,
C. Geppert,
S. Karpuk,
T. Reich,
C. Siemensen,
Y. Sobolev,
N. Trautmann
Abstract:
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently o…
▽ More
Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a 'standard' UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.
△ Less
Submitted 26 October, 2016;
originally announced October 2016.
-
Precise Measurement of Magnetic Field Gradients from Free Spin Precession Signals of $^{3}$He and $^{129}$Xe Magnetometers
Authors:
F. Allmendinger,
P. Blümler,
M. Doll,
O. Grasdijk,
W. Heil,
K. Jungmann,
S. Karpuk,
H. -J. Krause,
A. Offenhäusser,
M. Repetto,
U. Schmidt,
Yu. Sobolev,
K. Tullney,
L. Willmann,
S. Zimmer
Abstract:
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relax…
▽ More
We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relaxation rates of both spin species are simultaneously monitored as magnetic field gradients are varied. For transverse relaxation times reaching 100 h, the residual longitudinal field gradient across the spin sample could be deduced to be$|\vec{\nabla}B_z|=(5.6 \pm 0.4)$ pT/cm. The method takes advantage of the high signal-to-noise ratio with which the decaying spin precession signal can be monitored that finally leads to the exceptional accuracy to determine magnetic field gradients at the sub pT/cm scale.
△ Less
Submitted 5 August, 2016;
originally announced August 2016.
-
Limit on Lorentz-Invariance- and CPT-Violating Neutron Spin Interactions Using a $^3$He-$^{129}$Xe Comagnetometer
Authors:
Fabian Allmendinger,
Ulrich Schmidt,
Werner Heil,
Sergej Karpuk,
Yuri Sobolev
Abstract:
We performed a search for a Lorentz-invariance- and CPT-violating coupling of the $^3$He and $^{129}$Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized $^3$He and $^{129}$Xe atoms using SQUID detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the L…
▽ More
We performed a search for a Lorentz-invariance- and CPT-violating coupling of the $^3$He and $^{129}$Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized $^3$He and $^{129}$Xe atoms using SQUID detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field $\tilde{b}^n_{\bot}< 8.4 \cdot 10^{-34}$ GeV (68\% C.L.). Furthermore, this technique was modified to search for an electric dipole moment (EDM) of $^{129}$Xe.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
Test of Time Dilation Using Stored Li+ Ions as Clocks at Relativistic Speed
Authors:
Benjamin Botermann,
Dennis Bing,
Christopher Geppert,
Gerald Gwinner,
Theodor W. Hänsch,
Gerhard Huber,
Sergei Karpuk,
Andreas Krieger,
Thomas Kühl,
Wilfried Nörtershäuser,
Christian Novotny,
Sascha Reinhardt,
Rodolfo Sánchez,
Dirk Schwalm,
Thomas Stöhlker,
Andreas Wolf,
Guido Saathoff
Abstract:
We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of beta = v/c = 0.338 in the storage ring ESR at Darmstadt. A Lambda-type three-level system within the hyperfine structure of the 7Li+ triplet S1-P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers' Doppler shifted freq…
▽ More
We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of beta = v/c = 0.338 in the storage ring ESR at Darmstadt. A Lambda-type three-level system within the hyperfine structure of the 7Li+ triplet S1-P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers' Doppler shifted frequencies required for resonance are measured with an accuracy of < 4 ppb using optical-optical double resonance spectroscopy. This allows us to verify the Special Relativity relation between the time dilation factor gamma and the velocity beta to within 2.3 ppb at this velocity. The result, which is singled out by a high boost velocity beta, is also interpreted within Lorentz Invariance violating test theories.
△ Less
Submitted 28 September, 2014;
originally announced September 2014.
-
Ultrasensitive 3He magnetometer for measurements of high magnetic fields
Authors:
A. Nikiel,
P. Blümler,
W. Heil,
M. Hehn,
S. Karpuk,
A. Maul,
E. Otten,
L. M. Schreiber,
M. Terekhov
Abstract:
We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of o…
▽ More
We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of order minutes which is achieved for spherical sample cells in the regime of motional narrowing where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in-situ using a new, non-standard variant of the metastability exchange optical pumping. We show that miniaturization helps to increase T2* further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10^-4.
△ Less
Submitted 27 May, 2014;
originally announced May 2014.
-
New limit on Lorentz and CPT violating neutron spin interactions using a free precession 3He-129Xe co-magnetometer
Authors:
F. Allmendinger,
W. Heil,
S. Karpuk,
W. Kilian,
A. Scharth,
U. Schmidt,
A. Schnabel,
Yu. Sobolev,
K. Tullney
Abstract:
We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor fields which permeate the universe. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low…
▽ More
We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor fields which permeate the universe. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low-noise magnetic flux detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field interacting with the spin of the bound neutron bn< 6.7*10^-34 GeV (68% C.L.). Our result improves our previous limit (data measured in 2009) by a factor of 30 and the world's best limit by a factor of 5.
△ Less
Submitted 11 December, 2013;
originally announced December 2013.
-
Modern Ives-Stilwell Experiments At Storage Rings: Large Boosts Meet High Precision
Authors:
G. Gwinner,
B. Botermann,
C. Geppert,
G. Huber,
S. Karpuk,
A. Krieger,
W. Nörtershäuser,
C. Novotny,
T. Kühl,
R. Sanchez,
T. Stöhlker,
D. Bing,
D. Schwalm,
A. Wolf,
T. W. Hänsch,
S. Reinhardt,
G. Saathoff
Abstract:
We give a brief overview of time dilation tests using high-resolution laser spectroscopy at heavy-ion storage rings. We reflect on the various methods used to eliminate the first-order Doppler effect and on the pitfalls encountered, and comment on possible extensions at future facilities providing relativistic heavy ion beams at $γ\gg 1$.
We give a brief overview of time dilation tests using high-resolution laser spectroscopy at heavy-ion storage rings. We reflect on the various methods used to eliminate the first-order Doppler effect and on the pitfalls encountered, and comment on possible extensions at future facilities providing relativistic heavy ion beams at $γ\gg 1$.
△ Less
Submitted 2 September, 2013;
originally announced September 2013.
-
Probing Physics beyond the Standard Model with He/Xe clock comparison experiments
Authors:
U. Schmidt,
F. Allmendinger,
W. Heil,
S. Karpuk,
A. Scharth,
Y. Sobolev,
K. Tullney,
S. Zimmer
Abstract:
The comparison of the free precession of co-located 3He-129Xe spins (clock comparison) enables us to search for very tiny nonmagnetic spin interactions. With our setup we could establish new limits for Lorentz invariance violating interactions of spins with a relic background field which permeates the Universe and points in a preferred direction in space.
The comparison of the free precession of co-located 3He-129Xe spins (clock comparison) enables us to search for very tiny nonmagnetic spin interactions. With our setup we could establish new limits for Lorentz invariance violating interactions of spins with a relic background field which permeates the Universe and points in a preferred direction in space.
△ Less
Submitted 22 July, 2013;
originally announced July 2013.
-
Using a rotating magnetic guiding field for the 3He-129Xe-Comagnetometer
Authors:
F. Allmendinger,
U. Schmidt,
W. Heil,
S. Karpuk,
A. Scharth,
Y. Sobolev,
K. Tullney,
S. Zimmer
Abstract:
Our search for non-magnetic spin-dependent interactions is based on the measurement of free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT. We report on our approach to perform an adiabatic rotation of the guiding field that allows us to modulate possible non-magnetic spin-dependent interactions and to find an optimization procedure…
▽ More
Our search for non-magnetic spin-dependent interactions is based on the measurement of free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT. We report on our approach to perform an adiabatic rotation of the guiding field that allows us to modulate possible non-magnetic spin-dependent interactions and to find an optimization procedure for long transverse relaxation times T2* both for Helium and Xenon.
△ Less
Submitted 19 July, 2013;
originally announced July 2013.
-
Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"
Authors:
G. Saathoff,
S. Reinhardt,
R. Holzwarth,
T. W. Hänsch,
Th. Udem,
D. Bing,
D. Schwalm,
A. Wolf,
S. Karpuk,
G. Huber,
C. Novotny,
B. Botermann,
C. Geppert,
W. Nörtershäuser,
T. Kühl,
T. Stöhlker,
G. Gwinner
Abstract:
In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experim…
▽ More
In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.
△ Less
Submitted 28 February, 2011;
originally announced February 2011.