The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV
Authors:
H. Abramowicz,
D. Ahmadi,
J. Alcaraz,
O. Alonso,
L. Andricek,
J. Anguiano,
O. Arquero,
F. Arteche,
D. Attie,
O. Bach,
M. Basso,
J. Baudot,
A. Bean,
T. Behnke,
A. Bellerive,
Y. Benhammou,
M. Berggren,
G. Bertolone,
M. Besancon,
A. Besson,
O. Bezshyyko,
G. Blazey,
B. Bliewert,
J. Bonis,
R. Bosley
, et al. (254 additional authors not shown)
Abstract:
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magneti…
▽ More
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.
△ Less
Submitted 6 June, 2025;
originally announced June 2025.
-
Metrology requirements for the integrated luminosity measurement using small angle Bhabha scattering at ILC
Authors:
Ivan Smiljanić,
Ivanka Božović,
Goran Kačarević,
Mirko Radulović,
Jasna Stevanović
Abstract:
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review the metrology requirements for t…
▽ More
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review the metrology requirements for the targeted precision of $\mathcal{L}$ at foreseen ILC center-of-mass energies: 91.2 GeV, 250 GeV, 500 GeV and 1 TeV, using small-angle Bhabha scattering.
△ Less
Submitted 24 December, 2024; v1 submitted 3 July, 2024;
originally announced July 2024.
-
Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic,
Goran Kacarevic
Abstract:
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accele…
▽ More
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.
△ Less
Submitted 3 July, 2024; v1 submitted 29 April, 2024;
originally announced April 2024.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Measurement of the H to ZZ branching fraction at 350 GeV and 3 TeV CLIC
Authors:
N. Vukašinović,
I. Božović-Jelisavčić,
G. Kačarević,
M. Radulović,
J. Stevanović,
G. Milutinović-Dumbelović,
T. Agatonović-Jovin,
I. Smiljanić
Abstract:
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. I…
▽ More
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. It is shown that the product of the Higgs production cross-section and the branching fraction BR(${H\rightarrow\thinspace ZZ^\ast}$) can be measured with a relative statistical uncertainty of 20% (3.0%) at a centre-of-mass energy of 350 GeV (3 TeV) using semileptonic final states, assuming an integrated luminosity of 1 ab$^{-1}$ (5 ab$^{-1}$).
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
MEASUREMENT OF THE HIGGS BRANCHING RATIO BR($H\rightarrowγγ$) AT 3 TeV CLIC
Authors:
G. Kacarevic,
I. Bozovic Jelisavcic,
N. Vukasinovic,
I. Smiljanic,
M. Radulovic,
J. Stevanovic,
T. Agatonovic Jovin,
G. Milutinovic Dumbelovic
Abstract:
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the meas…
▽ More
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the measured BR($H\rightarrowγγ$), and consequently of the Higgs coupling $g_{Hγγ}$ from the predictions of the Standard Model, may indicate New Physics. The Higgs decay to two photons is thus an interesting probe of the Higgs sector.
This study is performed using simulation of the detector for CLIC and by considering all relevant physics and beam-induced processes in a full reconstruction chain. It is shown that the product of the Higgs production cross-section in $W^+W^-$ fusion and BR($H\rightarrowγγ$) can be measured with a relative statistical uncertainty of 5.5\%, assuming the integrated luminosity of 5 ab$^{-1}$ and unpolarized beams.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanić,
Ivanka Božović-Jelisavčić,
Goran Kačarević,
Nataša Vukašinović,
Tatjana Agatonović-Jovin,
Gordana Milutinović-Dumbelović,
Jasna Stevanović,
Mirko Radulović
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning, beam-related requirements and physics background.A method of the effective center-of-mass determination from $e^+e^- \to μ^+μ^-$, initially proposed for FCC, is also discussed for the CEPC beams.
△ Less
Submitted 31 January, 2022; v1 submitted 13 May, 2021;
originally announced May 2021.
-
Systematic uncertainties in integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic Jelisavcic,
Goran Kacarevic,
Natasa Vukasinovic,
Ivana Vidakovic,
Vladimir Rekovic
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechani…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams.
△ Less
Submitted 23 November, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
Beam-spread determination for luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic-Jelisavcic,
Goran Kacarevic
Abstract:
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in o…
▽ More
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in order to control the uncertainty of Bhabha count at the level of 0.01%. Here we discuss the method, initially proposed for FCCee, to determine variation of the beam-spread from the measurement of the effective center-of-mass energy in $e^+e^- \to μ^+μ^-$ collisions.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
O. Borysov,
M. Borysova,
I. Bozovic- Jelisavcic,
W. Daniluk,
D. Dannheim,
M. Demichev,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempelb,
H. Henschel,
M. Idzik,
A. Ignatenkoc,
A. Ishikawa,
A. Joffe,
G. Kacarevic,
S. Kananov,
O. Karachebanb
, et al. (29 additional authors not shown)
Abstract:
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi…
▽ More
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
△ Less
Submitted 25 October, 2019; v1 submitted 29 December, 2018;
originally announced December 2018.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.