-
Seismic Isolation of Optical Tables Using Piezo Actuators
Authors:
Tailong Wang,
Carl Blair,
Ammar Al-Jodah,
John Winterflood,
Jian Liu,
Alexander Adams,
Aaron Goodwin-Jones,
Chunnong Zhao,
Li Ju
Abstract:
Seismic isolation is crucial for gravitational wave detectors as it minimizes ground vibrations, enabling the detection of faint gravitational wave signals. An active seismic isolation platform for precision measurement experiments is described. The table features piezo actuation along five degrees of freedom: three translational actuations and two tip-tilt degrees of freedom along the horizontal…
▽ More
Seismic isolation is crucial for gravitational wave detectors as it minimizes ground vibrations, enabling the detection of faint gravitational wave signals. An active seismic isolation platform for precision measurement experiments is described. The table features piezo actuation along five degrees of freedom: three translational actuations and two tip-tilt degrees of freedom along the horizontal axes. It is stiff in rotation about the vertical axes. A seismometer is used to sense table motion. Piezo actuators are used to suppress seismic noise with feedback control bandwidth of 0.3 to 3 Hz. Suppression levels ranging from 21 to 36 dB of seismic noise within the frequency range of 0.5 to 1.3 Hz are demonstrated, as measured by a witness seismometer on the table, with the suppression direction along the axis of the longitudinal translation of the suspended mirror on the table. The suppression results in 1 $\mathrm{\mathrm{nm/\sqrt{Hz}}}$ residual horizontal motion at 1 Hz. Limitations such as tilt-to-translation coupling that prevent actuation over the desired range of 0.03 to 3 Hz are discussed.
△ Less
Submitted 19 May, 2025;
originally announced May 2025.
-
Matched Asymptotic Expansions-Based Transferable Neural Networks for Singular Perturbation Problems
Authors:
Zhequan Shen,
Lili Ju,
Liyong Zhu
Abstract:
In this paper, by utilizing the theory of matched asymptotic expansions, an efficient and accurate neural network method, named as "MAE-TransNet", is developed for solving singular perturbation problems in general dimensions, whose solutions usually change drastically in some narrow boundary layers. The TransNet is a two-layer neural network with specially pre-trained hidden-layer neurons. In the…
▽ More
In this paper, by utilizing the theory of matched asymptotic expansions, an efficient and accurate neural network method, named as "MAE-TransNet", is developed for solving singular perturbation problems in general dimensions, whose solutions usually change drastically in some narrow boundary layers. The TransNet is a two-layer neural network with specially pre-trained hidden-layer neurons. In the proposed MAE-TransNet, the inner and outer solutions produced from the matched asymptotic expansions are first approximated by a TransNet with nonuniform hidden-layer neurons and a TransNet with uniform hidden-layer neurons, respectively. Then, these two solutions are combined with a matching term to obtain the composite solution, which approximates the asymptotic expansion solution of the singular perturbation problem. This process enables the MAE-TransNet method to retain the precision of the matched asymptotic expansions while maintaining the efficiency and accuracy of TransNet. Meanwhile, the rescaling of the sharp region allows the same pre-trained network parameters to be applied to boundary layers with various thicknesses, thereby improving the transferability of the method. Notably, for coupled boundary layer problems, a computational framework based on MAE-TransNet is also constructed to effectively address issues resulting from the lack of relevant matched asymptotic expansion theory in such problems. Our MAE-TransNet is compared with TransNet, PINN, and Boundary-Layer PINN on various benchmark problems including 1D linear and nonlinear problems with boundary layers, the 2D Couette flow problem, a 2D coupled boundary layer problem, and the 3D Burgers vortex problem. Numerical results demonstrate that MAE-TransNet significantly outperforms other neural network methods in capturing the characteristics of boundary layers, improving the accuracy, and reducing the computational cost.
△ Less
Submitted 13 May, 2025;
originally announced May 2025.
-
Demonstration of optical spring in an un-detuned cavity containing an optical parametric amplifier
Authors:
Jian Liu,
Juntao Pan,
Carl Blair,
Jue Zhang,
Hengxin Sun,
Li Ju,
Chunnong Zhao
Abstract:
Here we demonstrate the capacity to manipulate the optical spring (OS) effect by employing an optical parametric amplifier (OPA) within an optical cavity. We observed more than a factor of 2 increase in the OS frequency shift with the OPA. We also showed for the first time that the OS can be tuned by solely adjusting the OPA phase and showing an un-detuned cavity exhibiting an optical spring. The…
▽ More
Here we demonstrate the capacity to manipulate the optical spring (OS) effect by employing an optical parametric amplifier (OPA) within an optical cavity. We observed more than a factor of 2 increase in the OS frequency shift with the OPA. We also showed for the first time that the OS can be tuned by solely adjusting the OPA phase and showing an un-detuned cavity exhibiting an optical spring. The method can be applied to gravitational wave detectors in the signal recycling configuration to realize narrow bandwidth high sensitivity. The OS can be tuned to align the detector peak sensitivity frequency to known frequency continuous gravitational wave signals, dynamically tuned to track the gravitational wave signal from merging compact binaries or tuned to search for the post-merger signal of known binary coalescence.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
A new approach for the implementation of contact line motion based on the phase-filed lattice Boltzmann method
Authors:
Long Ju,
Zhaoli Guo,
Bicheng Yan,
Shuyu Sun
Abstract:
This paper proposes a new strategy to implement the free-energy based wetting boundary condition within the phase-field lattice Boltzmann method. The greatest advantage of the proposed method is that the implementation of contact line motion can be significantly simplified while still maintaining good accuracy. For this purpose, the liquid-solid free energy is treated as a part of the chemical pot…
▽ More
This paper proposes a new strategy to implement the free-energy based wetting boundary condition within the phase-field lattice Boltzmann method. The greatest advantage of the proposed method is that the implementation of contact line motion can be significantly simplified while still maintaining good accuracy. For this purpose, the liquid-solid free energy is treated as a part of the chemical potential instead of the boundary condition, thus avoiding complicated interpolations with irregular geometries. Several numerical testing cases including the droplet spreading processes on the idea flat, inclined and curved boundaries are conducted, and the results demonstrate that the proposed method has good ability and satisfactory accuracy to simulate contact line motions.
△ Less
Submitted 1 December, 2023;
originally announced December 2023.
-
A well-balanced lattice Boltzmann model for binary fluids based on the incompressible phase-field theory
Authors:
Long Ju,
Peiyao Liu,
Bicheng Yan,
Jin Bao,
Shuyu Sun,
Zhaoli Guo
Abstract:
Spurious velocities arising from the imperfect offset of the undesired term at the discrete level are frequently observed in numerical simulations of equilibrium multiphase flow systems using the lattice Boltzmann equation (LBE) method. To capture the physical equilibrium state of two-phase fluid systems and eliminate spurious velocities, a well-balanced LBE model based on the incompressible phase…
▽ More
Spurious velocities arising from the imperfect offset of the undesired term at the discrete level are frequently observed in numerical simulations of equilibrium multiphase flow systems using the lattice Boltzmann equation (LBE) method. To capture the physical equilibrium state of two-phase fluid systems and eliminate spurious velocities, a well-balanced LBE model based on the incompressible phase-field theory is developed. In this model, the equilibrium distribution function for the Cahn-Hilliard (CH) equation is designed by treating the convection term as a source to avoid the introduction of undesired terms, enabling achievement of possible discrete force balance. Furthermore, this approach allows for the attainment of a divergence-free velocity field, effectively mitigating the impact of artificial compression effects and enhancing numerical stability. Numerical tests, including a flat interface problem, a stationary droplet, and the coalescence of two droplets, demonstrate the well-balanced properties and improvements in the stability of the present model.
△ Less
Submitted 17 November, 2023;
originally announced November 2023.
-
Single and coupled cavity mode sensing schemes using a diagnostic field
Authors:
Aaron W. Goodwin-Jones,
Haochen Zhu,
Carl Blair,
Daniel D. Brown,
Joris van Heijningen,
Li Ju,
Chunnong Zhao
Abstract:
Precise optical mode matching is of critical importance in experiments using squeezed-vacuum states. Automatic spatial-mode matching schemes have the potential to reduce losses and improve loss stability. However, in quantum-enhanced coupled-cavity experiments, such as gravitational-wave detectors, one must also ensure that the sub-cavities are also mode matched. We propose a new mode sensing sche…
▽ More
Precise optical mode matching is of critical importance in experiments using squeezed-vacuum states. Automatic spatial-mode matching schemes have the potential to reduce losses and improve loss stability. However, in quantum-enhanced coupled-cavity experiments, such as gravitational-wave detectors, one must also ensure that the sub-cavities are also mode matched. We propose a new mode sensing scheme, which works for simple and coupled cavities. The scheme requires no moving parts, nor tuning of Gouy phases. Instead a diagnostic field tuned to the HG20/LG10 mode frequency is used. The error signals are derived to be proportional to the difference in waist position, and difference in Rayleigh ranges, between the sub-cavity eigenmodes. The two error signals are separable by 90 degrees of demodulation phase. We demonstrate reasonable error signals for a simplified Einstein Telescope optical design. This work will facilitate routine use of extremely high levels of squeezing in current and future gravitational-wave detectors.
△ Less
Submitted 29 August, 2023;
originally announced August 2023.
-
Developing and implementing an Einsteinian science curriculum from Years 3 to 10: Part B Teacher upskilling: response to training and teacher's classroom experience
Authors:
Tejinder Kaur,
Magdalena Kersting,
Kyla Adams,
David Blair,
David Treagust,
Anastasia Popkova,
Shon Boublil,
Jesse Santoso,
Li Ju,
Marjan Zadnik,
David Wood,
Elaine Horne,
Darren McGoran,
Susan Scott,
Grady Venville
Abstract:
Recent years have seen a growing interest in modernizing physics and science curricula around the world. While many science educators and curriculum developers design instructional resources to successfully introduce topics of Einsteinian physics to young learners, it is clear that successful curriculum development needs to rest on successful teacher professional development.Teachers with or witho…
▽ More
Recent years have seen a growing interest in modernizing physics and science curricula around the world. While many science educators and curriculum developers design instructional resources to successfully introduce topics of Einsteinian physics to young learners, it is clear that successful curriculum development needs to rest on successful teacher professional development.Teachers with or without science backgrounds were trained in short professional learning workshops or completed micro-credential courses. The courses enabled teachers to gain knowledge and confidence to deliver the Einstein-First program. Detailed lesson plans and instructional videos for teachers define the lessons. Questionnaires were used to collect data, and teacher interviews were conducted following the various teacher training programs. The research results show that teachers effectively deliver the Einsteinian physics programs and that their subject matter and pedagogical content knowledge increased. In addition, teacher attitudes were favorable towards modernizing the physics curriculum. We conclude that it is feasible to upskill teachers from diverse backgrounds in Einsteinian physics and break the cycle that has inhibited the modernization of school curricula.
△ Less
Submitted 19 December, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Developing and implementing an Einsteinian science curriculum from Years 3 to 10 : Part A Concepts, rationale and learning outcomes
Authors:
Tejinder Kaur,
Magdalena Kersting,
David Blair,
Kyla Adams,
David Treagust,
Jesse Santoso,
Anastasia Popkova,
Shon Boublil,
Marjan Zadnik,
Li Ju,
David Wood,
Elaine Horne,
Darren McGoran
Abstract:
There has been a growing realisation that school science curricula do not adequately reflect the revolutionary changes in our scientific understanding of the 20th century. This discrepancy between current school education and our modern scientific understanding has led to calls for the modernisation of the science curriculum. Although there have been attempts to introduce topics of Einsteinian phy…
▽ More
There has been a growing realisation that school science curricula do not adequately reflect the revolutionary changes in our scientific understanding of the 20th century. This discrepancy between current school education and our modern scientific understanding has led to calls for the modernisation of the science curriculum. Although there have been attempts to introduce topics of Einsteinian physics (i.e., quantum physics and relativity) to school education, often at the secondary level, we still lack a seamless curriculum in which modern science concepts are gradually introduced in primary and middle schools. Guided by the Model of Educational Reconstruction and following a mixed-methods research design, the Einstein-First project aims to address this gap. Einstein-First has developed and implemented an Einsteinian curriculum from Years 3 to 10 (students aged 7- 16) that resolves the disconnect between science in schools and the modern world. This paper presents the concepts, rationale, and learning outcomes of the curriculum implementation in six Australian schools with 315 students across Years 3 to 10. Our findings lay the foundation for informed curriculum development towards a school education that can enhance students' understanding and appreciation of the fundamental concepts of modern science and its impact on our society.
△ Less
Submitted 21 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Seismic noise characterization at a potential gravitational wave detector site in Australia
Authors:
Hamid Satari,
Carl Blair,
Li Ju,
David Blair,
Chunnong Zhao,
Erdinc Saygin,
Patrick Meyers,
David Lumley
Abstract:
A critical consideration in the design of next generation gravitational wave detectors is the understanding of the seismic environment that can introduce coherent and incoherent noise of seismic origin at different frequencies. We present detailed low-frequency ambient seismic noise characterization (0.1--10~Hz) at the Gingin site in Western Australia. Unlike the microseism band (0.06--1~Hz) for w…
▽ More
A critical consideration in the design of next generation gravitational wave detectors is the understanding of the seismic environment that can introduce coherent and incoherent noise of seismic origin at different frequencies. We present detailed low-frequency ambient seismic noise characterization (0.1--10~Hz) at the Gingin site in Western Australia. Unlike the microseism band (0.06--1~Hz) for which the power shows strong correlations with nearby buoy measurements in the Indian Ocean, the seismic spectrum above 1~Hz is a complex superposition of wind induced seismic noise and anthropogenic seismic noise which can be characterized using beamforming to distinguish between the effects of coherent and incoherent wind induced seismic noise combined with temporal variations in the spatio-spectral properties of seismic noise. This also helps characterizing the anthropogenic seismic noise. We show that wind induced seismic noise can either increase or decrease the coherency of background seismic noise for wind speeds above 6~m/s due to the interaction of wind with various surface objects. In comparison to the seismic noise at the Virgo site, the secondary microseism (0.2~Hz) noise level is higher in Gingin, but the seismic noise level between 1 and 10~Hz is lower due to the sparse population and absence of nearby road traffic.
△ Less
Submitted 22 February, 2023; v1 submitted 14 September, 2022;
originally announced September 2022.
-
Low coherency of wind induced seismic noise: Implications for gravitational wave detection
Authors:
Hamid Satari,
Carl Blair,
Li Ju,
Erdinc Saygin,
David Blair,
Chunnong Zhao,
David Lumley,
Patrick Meyers
Abstract:
Seismic noise poses challenges for gravitational wave detection. Effective vibration isolation and methods to subtract unsheildable Newtonian Noise are examples. Seismic arrays offer one way to deal with these issues assuming seismic coherency. In this paper we find that wind induced seismic noise is incoherent and will dramatically reduce the projected low frequency sensitivity of future gravitat…
▽ More
Seismic noise poses challenges for gravitational wave detection. Effective vibration isolation and methods to subtract unsheildable Newtonian Noise are examples. Seismic arrays offer one way to deal with these issues assuming seismic coherency. In this paper we find that wind induced seismic noise is incoherent and will dramatically reduce the projected low frequency sensitivity of future gravitational wave detectors. To quantify this, we measure the coherence length of wind induced seismic noise from 0.06--20~Hz in three distinct locations: close to a building, among tall trees and in shrubs. We show that wind induced seismic noise is ubiquitous and reduces the coherence lengths form several hundred meters to 2--40~m for 0.06--0.1~Hz, from $>$60~m to 3--16~m for 1.5--2.5~Hz and from $>$35~m to 1--16~m around 16.6 Hz frequency bands in the study area. This leads to significant loss of velocity and angular resolution of the array for primary microseism, 5 times worse Newtonian Noise cancellation by wiener filtering at 2~Hz, while it does not pose additional challenge for Newtonian Noise cancellation between 10--20~Hz.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
Demonstration of Parametric Instability suppression through optical feedback
Authors:
Vladimir Bossilkov,
Jian Liu,
Carl Blair,
Chunnong Zhao,
Li Ju
Abstract:
We demonstrate the suppression of parametric instability using through optical actuation in an electro-optical feedback loop, stabilising the high order optical mode content in an 80 metre long Fabry-Perot cavity. The loop suppression of the high order mode is achieved by injecting a high order mode with the same frequency and opposite phase. Frequency matching is achieved by measuring the beat no…
▽ More
We demonstrate the suppression of parametric instability using through optical actuation in an electro-optical feedback loop, stabilising the high order optical mode content in an 80 metre long Fabry-Perot cavity. The loop suppression of the high order mode is achieved by injecting a high order mode with the same frequency and opposite phase. Frequency matching is achieved by measuring the beat note signal between the fundamental and high order mode in transmission of the cavity and applying that signal to an electro-optical modulator to create the required frequency sideband. Spatial mode matching of the sideband to the high order mode is accomplished through the inherent mode overlap between the input injected beam and the high order mode of the cavity. The paper presents the theoretical analysis and experimental demonstration of parametric instability suppression, for an instability which would normally ring up with a parametric gain of approximately 2.5.
△ Less
Submitted 27 February, 2022;
originally announced February 2022.
-
Parallel Exponential Time Differencing Methods for Geophysical Flow Simulations
Authors:
Rihui Lan,
Wei Leng,
Zhu Wang,
Lili Ju,
Max Gunzburger
Abstract:
Two ocean models are considered for geophysical flow simulations: the multi-layer shallow water equations and the multi-layer primitive equations. For the former, we investigate the parallel performance of exponential time differencing (ETD) methods, including exponential Rosenbrock-Euler, ETD2wave, and B-ETD2wave. For the latter, we take advantage of the splitting of barotropic and baroclinic mod…
▽ More
Two ocean models are considered for geophysical flow simulations: the multi-layer shallow water equations and the multi-layer primitive equations. For the former, we investigate the parallel performance of exponential time differencing (ETD) methods, including exponential Rosenbrock-Euler, ETD2wave, and B-ETD2wave. For the latter, we take advantage of the splitting of barotropic and baroclinic modes and propose a new two-level method in which an ETD method is applied to solve the fast barotropic mode. These methods could improve the computational efficiency of numerical simulations because ETD methods allow for much larger time step sizes than traditional explicit time-stepping techniques that are commonly used in existing computational ocean models. Several standard benchmark tests for ocean modeling are performed and comparison of the numerical results demonstrate a great potential of applying the parallel ETD methods for simulating real-world geophysical flows.
△ Less
Submitted 27 May, 2021;
originally announced June 2021.
-
Multi-blade monolithic Euler springs with optimised stress distribution
Authors:
J. V. van Heijningen,
J. Winterflood,
B. Wu,
L. Ju
Abstract:
Euler springs are used for vertical suspension and vibration isolation as they provide a large static supporting force with a low spring-rate and use minimal spring material. To date, multiple single-width rectangular blades of uniform thickness and stacked flat-face to flat-face have been used in the post buckled state, with half of the blades buckling in each of opposing directions. For ultra-lo…
▽ More
Euler springs are used for vertical suspension and vibration isolation as they provide a large static supporting force with a low spring-rate and use minimal spring material. To date, multiple single-width rectangular blades of uniform thickness and stacked flat-face to flat-face have been used in the post buckled state, with half of the blades buckling in each of opposing directions. For ultra-low-noise isolation the ends need to be clamped which results in stick-slip issues at the joints. In this study we investigate the benefits of forming side-by-side oppositely buckling blades from a single monolithic sheet of spring material. Additionally, we study how to distribute the stress evenly along the length of the blade by contouring its width, as well as finding the optimal contour to distribute the stress evenly around the tearing joints between oppositely bending blade sections. We show that this optimal shaping typically improves the inconveniently small spring working range by over 60 % compared to an equivalent rectangular blade.
△ Less
Submitted 6 February, 2023; v1 submitted 8 April, 2021;
originally announced April 2021.
-
Gravitational wave detectors with broadband high frequency sensitivity
Authors:
Michael A. Page,
Maxim Goryachev,
Haixing Miao,
Yanbei Chen,
Yiqiu Ma,
David Mason,
Massimiliano Rossi,
Carl D. Blair,
Li Ju,
David G. Blair,
Albert Schliesser,
Michael E. Tobar,
Chunnong Zhao
Abstract:
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Res…
▽ More
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Resonant enhancement by signal recycling normally improves the signal to noise ratio at the expense of bandwidth. The concept of optomechanical white light signal recycling (WLSR) has been proposed, but all schemes to date have been reliant on the development of suitable ultra-low mechanical loss components. Here for the first time we show demonstrated optomechanical resonator structures that meet the loss requirements for a WLSR interferometer with strain sensitivity below 10$^{-24}$ Hz$^{-1/2}$ at a few kHz. Experimental data for two resonators are combined with analytic models of 4km interferometers similar to LIGO, to demonstrate sensitivity enhancement across a much broader band of neutron star coalescence frequencies than dual-recycled Fabry-Perot Michelson detectors of the same length. One candidate resonator is a silicon nitride membrane acoustically isolated from the environment by a phononic crystal. The other is a single-crystal quartz lens that supports bulk acoustic longitudinal waves. Optical power requirements could prefer the membrane resonator, although the bulk acoustic wave resonator gives somewhat better thermal noise performance. Both could be implemented as add-on components to existing detectors.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Upconversion nonlinear structured illumination microscopy
Authors:
Baolei Liu,
Chaohao Chen,
Xiangjun Di,
Jiayan Liao,
Shihui Wen,
Qian Peter Su,
Xuchen Shan,
Zai-Quan Xu,
Lining Arnold Ju,
Fan Wang,
Dayong Jin
Abstract:
Video-rate super-resolution imaging through biological tissue can visualize and track biomolecule interplays and transportations inside cellular organisms. Structured illumination microscopy allows for wide-field super resolution observation of biological samples but is limited by the strong absorption and scattering of light by biological tissues, which degrades its imaging resolution. Here we re…
▽ More
Video-rate super-resolution imaging through biological tissue can visualize and track biomolecule interplays and transportations inside cellular organisms. Structured illumination microscopy allows for wide-field super resolution observation of biological samples but is limited by the strong absorption and scattering of light by biological tissues, which degrades its imaging resolution. Here we report a photon upconversion scheme using lanthanide-doped nanoparticles for wide-field super-resolution imaging through the biological transparent window, featured by near-infrared and low-irradiance nonlinear structured illumination. We demonstrate that the 976 nm excitation and 800 nm up-converted emission can mitigate the aberration. We found that the nonlinear response of upconversion emissions from single nanoparticles can effectively generate the required high spatial frequency components in Fourier domain. These strategies lead to a new modality in microscopy with a resolution of 130 nm, 1/7th of the excitation wavelength, and a frame rate of 1 fps.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
Conservative numerical schemes with optimal dispersive wave relations -- Part II. Numerical evaluations
Authors:
Qingshan Chen,
Lili Ju,
Roger Temam
Abstract:
A new energy and enstrophy conserving scheme is evaluated using a suite of test cases over the global spherical domain or bounded domains. The evaluation is organized around a set of pre-defined properties: accuracy of individual opeartors, accuracy of the whole scheme, conservation, control of the divergence variable, representation of the energy and enstrophy spectra, and simulation of nonlinear…
▽ More
A new energy and enstrophy conserving scheme is evaluated using a suite of test cases over the global spherical domain or bounded domains. The evaluation is organized around a set of pre-defined properties: accuracy of individual opeartors, accuracy of the whole scheme, conservation, control of the divergence variable, representation of the energy and enstrophy spectra, and simulation of nonlinear dynamics. The results confirm that the scheme is between the first and second order accurate, and conserves the total energy and potential enstrophy up to the time truncation errors. The scheme is capable of producing more physically realistic energy and enstrophy spectra, indicating that the new scheme can help prevent the unphysical energy cascade towards the finest resolvable scales. With an optimal representation of the dispersive wave relations, the scheme is able to keep the flow close to being non-divergent, maintain the geostrophically balanced structures with large-scale geophysical flows over long-term simulations.
△ Less
Submitted 9 December, 2020; v1 submitted 6 February, 2020;
originally announced February 2020.
-
Simulating the external magnetic field in short-pulse intense laser-plasma interaction
Authors:
K. Jiang,
C. T. Zhou,
S. Z. Wu,
H. Zhang,
C. N. Wu,
T. Y. Long,
L. Li,
T. W. Huang,
L. B. Ju,
B. Qiao,
M. Y. Yu,
S. P. Zhu,
S. C. Ruan
Abstract:
Imposing an external magnetic field in short-pulse intense laser-plasma interaction is of broad scientific interest in related plasma research areas. We propose a simple method using a virtual current layer by introducing an extra current density term to simulate the external magnetic field, and demonstrate it with three-dimensional particle-in-cell simulations. The field distribution and its evol…
▽ More
Imposing an external magnetic field in short-pulse intense laser-plasma interaction is of broad scientific interest in related plasma research areas. We propose a simple method using a virtual current layer by introducing an extra current density term to simulate the external magnetic field, and demonstrate it with three-dimensional particle-in-cell simulations. The field distribution and its evolution in sub-picosecond time scale are obtained. The magnetization process takes a much longer time than that of laser-plasma interaction due to plasma diamagnetism arising from collective response. The long-time evolution of magnetic diffusion and diamagnetic current can be predicted based on a simplified analytic model in combination with simulations.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.
-
Conservative numerical schemes with optimal dispersive wave relations -- Part I. Derivations and analyses
Authors:
Qingshan Chen,
Lili Ju,
Roger Temam
Abstract:
An energy-conserving and an energy-and-enstrophy conserving numerical schemes are derived, by approximating the Hamiltonian formulation, based on the Poisson brackets and the vorticity-divergence variables, of the inviscid shallow water flows. The conservation of the energy and/or enstrophy stems from skew-symmetry of the Poisson brackets, which is retained in the discrete approximations. These sc…
▽ More
An energy-conserving and an energy-and-enstrophy conserving numerical schemes are derived, by approximating the Hamiltonian formulation, based on the Poisson brackets and the vorticity-divergence variables, of the inviscid shallow water flows. The conservation of the energy and/or enstrophy stems from skew-symmetry of the Poisson brackets, which is retained in the discrete approximations. These schemes operate on unstructured orthogonal dual meshes, over bounded or unbounded domains, and they are also shown to possess the same optimal dispersive wave relations as those of the Z-grid scheme.
△ Less
Submitted 28 May, 2019;
originally announced May 2019.
-
Direction and divergence control of laser-driven energetic proton beam using a disk-solenoid target
Authors:
K. Jiang,
C. T. Zhou,
T. W. Huang,
L. B. Ju,
C. N. Wu,
L. Li,
H. Zhang,
S. Z. Wu,
T. X. Cai,
B. Qiao,
M. Y. Yu,
S. C. Ruan
Abstract:
A scheme for controlling the direction of energetic proton beam driven by intense laser pulse is proposed. Simulations show that a precisely directed and collimated proton bunch can be produced by a sub-picosecond laser pulse interacting with a target consisting of a thin solid-density disk foil with a solenoid coil attached to its back at the desired angle. It is found that two partially overlapp…
▽ More
A scheme for controlling the direction of energetic proton beam driven by intense laser pulse is proposed. Simulations show that a precisely directed and collimated proton bunch can be produced by a sub-picosecond laser pulse interacting with a target consisting of a thin solid-density disk foil with a solenoid coil attached to its back at the desired angle. It is found that two partially overlapping sheath fields are induced. As a result, the accelerated protons are directed parallel to the axis of the solenoid, and their spread angle is also reduced by the overlapping sheath fields. The proton properties can thus be controlled by manipulating the solenoid parameters. Such highly directional and collimated energetic protons are useful in the high-energy-density as well as medical sciences.
△ Less
Submitted 28 December, 2018;
originally announced December 2018.
-
Angular instability in high optical power suspended cavities
Authors:
Jian Liu,
Vladimir Bossilkov,
Carl Blair,
Chunnong Zhao,
Li Ju,
David Blair
Abstract:
Advanced gravitational wave detectors use suspended test masses to form optical resonant cavities for enhancing the detector sensitivity. These cavities store hundreds of kilowatts of coherent light and even higher optical power for future detectors. With such high optical power, the radiation pressure effect inside the cavity creates sufficiently strong coupling between test masses whose dynamics…
▽ More
Advanced gravitational wave detectors use suspended test masses to form optical resonant cavities for enhancing the detector sensitivity. These cavities store hundreds of kilowatts of coherent light and even higher optical power for future detectors. With such high optical power, the radiation pressure effect inside the cavity creates sufficiently strong coupling between test masses whose dynamics are significantly altered. The dynamics of two independent nearly free masses become a coupled mechanical resonator system. The transfer function of the local control system used for controlling the test masses is modified by the radiation pressure effect. The changes in the transfer function of the local control systems can result in a new type of angular instability which occurs at only 1.3 \% of the Sidles-Sigg instability threshold power. We report experimental results on a 74~m suspended cavity with a few kilowatts of circulating power, for which the power to mass ratio is comparable to the current Advanced LIGO. The radiation pressure effect on the test masses behaves like an additional optical feedback with respect to the local angular control, potentially making the mirror control system unstable. When the local angular control system is optimized for maximum stability margin, the instability threshold power increases from 4~kW to 29~kW. The system behavior is consistent with our simulation and the power dependent evolution of both the cavity soft and hard mode is observed. We show that this phenomenon is likely to significantly affect proposed gravitational wave detectors that require very high optical power.
△ Less
Submitted 30 November, 2018;
originally announced December 2018.
-
An Exponential Time-Integrator Scheme for Steady and Unsteady Inviscid Flows
Authors:
Shu-Jie Li,
Li-Shi Luo,
Z. J. Wang,
Lili Ju
Abstract:
An exponential time-integrator scheme of second-order accuracy based on the predictor-corrector methodology, denoted PCEXP, is developed to solve multi-dimensional nonlinear partial differential equations pertaining to fluid dynamics. The effective and efficient implementation of PCEXP is realized by means of the Krylov method. The linear stability and truncation error are analyzed through a one-d…
▽ More
An exponential time-integrator scheme of second-order accuracy based on the predictor-corrector methodology, denoted PCEXP, is developed to solve multi-dimensional nonlinear partial differential equations pertaining to fluid dynamics. The effective and efficient implementation of PCEXP is realized by means of the Krylov method. The linear stability and truncation error are analyzed through a one-dimensional model equation. The proposed PCEXP scheme is applied to the Euler equations discretized with a discontinuous Galerkin method in both two and three dimensions. The effectiveness and efficiency of the PCEXP scheme are demonstrated for both steady and unsteady inviscid flows. The accuracy and efficiency of the PCEXP scheme are verified and validated through comparisons with the explicit third-order total variation diminishing Runge-Kutta scheme (TVDRK3), the implicit backward Euler (BE) and the implicit second-order backward difference formula (BDF2). For unsteady flows, the PCEXP scheme generates a temporal error much smaller than the BDF2 scheme does, while maintaining the expected acceleration at the same time. Moreover, the PCEXP scheme is also shown to achieve the computational efficiency comparable to the implicit schemes for steady flows.
△ Less
Submitted 19 January, 2018;
originally announced January 2018.
-
Injection dynamics of direct-laser accelerated electrons in a relativistic transparency regime
Authors:
K. Jiang,
C. T. Zhou,
T. W. Huang,
L. B. Ju,
H. Zhang,
B. Qiao,
S. C. Ruan
Abstract:
The dynamics of electron injection in the direct laser acceleration (DLA) regime was investigated by means of three-dimensional particle-in-cell simulations and theoretical analysis. It is shown that when an ultra-intense laser pulse propagates into a near-critical density or relativistically transparent plasma, the longitudinal charge-separation electric field excites an ion wave. The ion wave mo…
▽ More
The dynamics of electron injection in the direct laser acceleration (DLA) regime was investigated by means of three-dimensional particle-in-cell simulations and theoretical analysis. It is shown that when an ultra-intense laser pulse propagates into a near-critical density or relativistically transparent plasma, the longitudinal charge-separation electric field excites an ion wave. The ion wave modulates the local electric field and acts as a set of potential wells to guide the electrons, located on the edge of the plasma channel, to the central region, where the DLA takes place later on. In addition, it is pointed out that the self-generated azimuthal magnetic fields tend to suppress the injection process of electrons by deflecting them away from the laser field region. Understanding these physical processes paves the way for further optimizing the properties of direct-laser accelerated electron beams and the associated X/gamma-ray sources.
△ Less
Submitted 27 November, 2017; v1 submitted 9 November, 2017;
originally announced November 2017.
-
Conservative finite volume schemes for the quasi-geostrophic equation on coastal-conforming unstructured primal-dual meshes
Authors:
Qingshan Chen,
Lili Ju
Abstract:
In this paper we propose finite volume schemes for solving the inviscid and viscous quasi-geostrophic equations on coastal-conforming unstructured primal-dual meshes. Several approaches for enforcing the boundary conditions are also explored along with these schemes. The pure transport part in these schemes are shown to conserve the potential vorticity along fluid paths in an averaged sense, and c…
▽ More
In this paper we propose finite volume schemes for solving the inviscid and viscous quasi-geostrophic equations on coastal-conforming unstructured primal-dual meshes. Several approaches for enforcing the boundary conditions are also explored along with these schemes. The pure transport part in these schemes are shown to conserve the potential vorticity along fluid paths in an averaged sense, and conserve the potential enstrophy up to the time truncation errors. Numerical tests based on the centroidal Voronoi-Delaunay meshes are performed to confirm these properties, and to distinguish the dynamical behaviors of these schemes. Finally some potential applications of these schemes in different situations are discussed.
△ Less
Submitted 5 March, 2018; v1 submitted 7 September, 2017;
originally announced September 2017.
-
Thermal modulation for suppression of parametric instability in advanced gravitational wave detectors
Authors:
Y. B. Ma,
J. Liu,
Y. Q. Ma,
C. Zhao,
L. Ju,
D. G. Blair,
Z. H. Zhu
Abstract:
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could be suppressed by time variation of the mirror radius of curvature. In this paper, we present three dimensional finite element analysis of this thermo-acousto-opt…
▽ More
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could be suppressed by time variation of the mirror radius of curvature. In this paper, we present three dimensional finite element analysis of this thermo-acousto-optics system to determine whether thermal modulation could provide sufficient instability's suppression without degrading time averaged optical performance. It is shown that deformations due to the time averaged heating profile on the mirror surface can be compensated by rear surface heating of the test mass. Results show that a $CO_2$ laser heating beam with a modulation amplitude of $1$ Watt at 0.01 Hz is sufficient to stabilize acoustic mode with parametric gain up to 3. The parametric gain suppression factor is linearly proportional to the peak modulation power.
△ Less
Submitted 7 February, 2017;
originally announced February 2017.
-
Study of Parametric Instability of gravitational wave detectors using silicon test masses
Authors:
Jue Zhang,
Chunnong Zhao,
Li Ju,
David Blair
Abstract:
Parametric instability is an intrinsic risk in high power laser interferometer gravitational wave detectors, in which the optical cavity modes interact with the acoustic modes of the mirrors leading to exponential growth of the acoustic vibration. In this paper, we investigate the potential parametric instability for a proposed next generation gravitational wave detector based on cooled silicon te…
▽ More
Parametric instability is an intrinsic risk in high power laser interferometer gravitational wave detectors, in which the optical cavity modes interact with the acoustic modes of the mirrors leading to exponential growth of the acoustic vibration. In this paper, we investigate the potential parametric instability for a proposed next generation gravitational wave detector based on cooled silicon test masses. It is shown that there would be about 2 unstable modes per test mass, with the highest parametric gain of ~76. The importance of developing suitable instability suppression schemes is emphasized.
△ Less
Submitted 9 September, 2016; v1 submitted 6 September, 2016;
originally announced September 2016.
-
Track segment finding with CGEM-IT and matching to tracks in ODC
Authors:
Huai-Min Liu,
Ling-Hui Wu,
Liang-Liang Wang,
Liao-Yuan Dong,
Ming-Yi Dong,
Qing-Lei Xiu,
Qun Ou-Yang,
Wei-Dong Li,
Wei-Guo,
Li Xu-Dong Ju,
Xin-Hua Sun,
Ye Yuan,
Yao Zhang
Abstract:
The relative differences in coordinates of Cylindrical-Gas-Electron-Multiplier-Detector-based Inner Tracker (CGEM-IT) clusters are studied to search for track segments in CGEM-IT. With the full simulation of single muon track samples, clear patterns are found and parameterized for the correct cluster combinations. The cluster combinations satisfying the patterns are selected as track segment candi…
▽ More
The relative differences in coordinates of Cylindrical-Gas-Electron-Multiplier-Detector-based Inner Tracker (CGEM-IT) clusters are studied to search for track segments in CGEM-IT. With the full simulation of single muon track samples, clear patterns are found and parameterized for the correct cluster combinations. The cluster combinations satisfying the patterns are selected as track segment candidates in CGEM-IT with an efficiency higher than 99%. The parameters of the track segments are obtained by a helix fitting. Some chi-squared quantities, evaluating the differences in track parameters between the track segments in CGEM-IT and the tracks found in Outer-Drift-Chamber (ODC), are calculated and used to match them. Proper chi-squared requirements are determined as a function of transverse momentum and the matching efficiency is found reasonable.
△ Less
Submitted 11 April, 2016;
originally announced April 2016.
-
The next detectors for gravitational wave astronomy
Authors:
David Blair,
Li Ju,
Chunnong Zhao,
Linqing Wen,
Haixing Miao,
Ronggen Cai,
Jiangrui Gao,
Xuechun Lin,
Dong Liu,
Ling-An Wu,
Zonghong Zhu,
Giles Hammond,
Ho Jung Paik,
Viviana Fafone,
Alessio Rocchi,
Chunnong Zhao,
Yiqiu Ma,
Jiayi Qin,
Michael Page
Abstract:
This paper focuses on the next detectors for gravitational wave astronomy which will be required after the current ground based detectors have completed their initial observations, and probably achieved the first direct detection of gravitational waves. The next detectors will need to have greater sensitivity, while also enabling the world array of detectors to have improved angular resolution to…
▽ More
This paper focuses on the next detectors for gravitational wave astronomy which will be required after the current ground based detectors have completed their initial observations, and probably achieved the first direct detection of gravitational waves. The next detectors will need to have greater sensitivity, while also enabling the world array of detectors to have improved angular resolution to allow localisation of signal sources. Sect. 1 of this paper begins by reviewing proposals for the next ground based detectors, and presents an analysis of the sensitivity of an 8 km armlength detector, which is proposed as a safe and cost-effective means to attain a 4-fold improvement in sensitivity. The scientific benefits of creating a pair of such detectors in China and Australia is emphasised. Sect. 2 of this paper discusses the high performance suspension systems for test masses that will be an essential component for future detectors, while sect. 3 discusses solutions to the problem of Newtonian noise which arise from fluctuations in gravity gradient forces acting on test masses. Such gravitational perturbations cannot be shielded, and set limits to low frequency sensitivity unless measured and suppressed. Sects. 4 and 5 address critical operational technologies that will be ongoing issues in future detectors. Sect. 4 addresses the design of thermal compensation systems needed in all high optical power interferometers operating at room temperature. Parametric instability control is addressed in sect. 5. Only recently proven to occur in Advanced LIGO, parametric instability phenomenon brings both risks and opportunities for future detectors. The path to future enhancements of detectors will come from quantum measurement technologies. Sect. 6 focuses on the use of optomechanical devices for obtaining enhanced sensitivity, while sect. 7 reviews a range of quantum measurement options.
△ Less
Submitted 16 February, 2016;
originally announced February 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Towards thermal noise free optomechanics
Authors:
Michael Page,
Yiqiu Ma,
Chunnong Zhao,
David Blair,
Li Ju,
Huang-Wei Pan,
Shiuh Chao,
Valery Mitrofanov,
Hamed Sadeghian
Abstract:
Thermal noise generally greatly exceeds quantum noise in optomechanical devices unless the mechanical frequency is very high or the thermodynamic temperature is very low. This paper addresses the design concept for a novel optomechanical device capable of ultrahigh quality factors in the audio frequency band with negligible thermal noise. The proposed system consists of a minimally supported milli…
▽ More
Thermal noise generally greatly exceeds quantum noise in optomechanical devices unless the mechanical frequency is very high or the thermodynamic temperature is very low. This paper addresses the design concept for a novel optomechanical device capable of ultrahigh quality factors in the audio frequency band with negligible thermal noise. The proposed system consists of a minimally supported millimeter scale pendulum mounted in a Double End-Mirror Sloshing (DEMS) cavity that is topologically equivalent to a Membrane-in-the-Middle (MIM) cavity. The radiation pressure inside the high-finesse cavity allows for high optical stiffness, cancellation of terms which lead to unwanted negative damping and suppression of quantum radiation pressure noise. We solve for the optical spring dynamics of the system using the Hamiltonian, find the noise spectral density and show that stable optical trapping is possible. We also assess various loss mechanisms, one of the most important being the acceleration loss due to the optical spring. We show that practical devices, starting from a centre-of-mass pendulum frequency of 0.1 Hz, could achieve a maximum quality factor of $10^{14}$ with optical spring stiffened frequency 1-10 kHz. Small resonators of mass 1 $μ$g or less could achieve a Q-factor of $10^{11}$ at a frequency of 100 kHz. Applications for such devices include white light cavities for improvement of gravitational wave detectors, or sensors able to operate near the quantum limit.
△ Less
Submitted 22 August, 2016; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Gravitational wave astronomy: the current status
Authors:
David Blair,
Li Ju,
Chunnong Zhao,
Linqing Wen,
Qi Chu,
Qi Fang,
RongGen Cai,
JiangRui Gao,
XueChun Lin,
Dong Liu,
Ling-An Wu,
ZongHong Zhu,
David H. Reitze,
Koji Arai,
Fan Zhang,
Raffaele Flaminio,
Xingjiang Zhu,
George Hobbs,
Richard N. Manchester,
Ryan M. Shannon,
Carlo Baccigalupi,
Peng Xu,
Xing Bian,
Zhoujian Cao,
ZiJing Chang
, et al. (14 additional authors not shown)
Abstract:
In the centenary year of Einstein's General Theory of Relativity, this paper reviews the current status of gravitational wave astronomy across a spectrum which stretches from attohertz to kilohertz frequencies. Sect. 1 of this paper reviews the historical development of gravitational wave astronomy from Einstein's first prediction to our current understanding the spectrum. It is shown that detecti…
▽ More
In the centenary year of Einstein's General Theory of Relativity, this paper reviews the current status of gravitational wave astronomy across a spectrum which stretches from attohertz to kilohertz frequencies. Sect. 1 of this paper reviews the historical development of gravitational wave astronomy from Einstein's first prediction to our current understanding the spectrum. It is shown that detection of signals in the audio frequency spectrum can be expected very soon, and that a north-south pair of next generation detectors would provide large scientific benefits. Sect. 2 reviews the theory of gravitational waves and the principles of detection using laser interferometry. The state of the art Advanced LIGO detectors are then described. These detectors have a high chance of detecting the first events in the near future. Sect. 3 reviews the KAGRA detector currently under development in Japan, which will be the first laser interferometer detector to use cryogenic test masses. Sect. 4 of this paper reviews gravitational wave detection in the nanohertz frequency band using the technique of pulsar timing. Sect. 5 reviews the status of gravitational wave detection in the attohertz frequency band, detectable in the polarisation of the cosmic microwave background, and discusses the prospects for detection of primordial waves from the big bang. The techniques described in sects. 1-5 have already placed significant limits on the strength of gravitational wave sources. Sects. 6 and 7 review ambitious plans for future space based gravitational wave detectors in the millihertz frequency band. Sect. 6 presents a roadmap for development of space based gravitational wave detectors by China while sect. 7 discusses a key enabling technology for space interferometry known as time delay interferometry.
△ Less
Submitted 9 February, 2016;
originally announced February 2016.
-
Linear negative dispersion with a gain doublet via optomechanical interactions
Authors:
Jiayi Qin,
Chunnong Zhao,
Yiqiu Ma,
Li Ju,
David G. Blair
Abstract:
Optical cavities containing a negative dispersion medium have been proposed as a means of improving the sensitivity of laser interferometric gravitational wave (GW) detectors through the creation of white light signal recycling cavities. Here we classically demonstrate that negative dispersion can be realized using an optomechanical cavity pumped by a blue detuned doublet. We used an 85mm cavity w…
▽ More
Optical cavities containing a negative dispersion medium have been proposed as a means of improving the sensitivity of laser interferometric gravitational wave (GW) detectors through the creation of white light signal recycling cavities. Here we classically demonstrate that negative dispersion can be realized using an optomechanical cavity pumped by a blue detuned doublet. We used an 85mm cavity with an intra-cavity silicon nitride membrane. Tunable negative dispersion is demonstrated, with a phase derivative $d\varphi/df$ from $-0.14$ Deg$\cdot$Hz$^{-1}$ to $-4.2\times10^{-3}$ Deg$\cdot$Hz$^{-1}$.
△ Less
Submitted 21 February, 2015;
originally announced February 2015.
-
Observation of Parametric Instability in Advanced LIGO
Authors:
Matthew Evans,
Slawek Gras,
Peter Fritschel,
John Miller,
Lisa Barsotti,
Denis Martynov,
Aidan Brooks,
Dennis Coyne,
Rich Abbott,
Rana Adhikari,
Koji Arai,
Rolf Bork,
Bill Kells,
Jameson Rollins,
Nicolas Smith-Lefebvre,
Gabriele Vajente,
Hiroaki Yamamoto,
Ryan Derosa,
Anamaria Effler,
Keiko Kokeyama,
Joseph Betzweiser,
Valera Frolov,
Adam Mullavey,
Sheila Dwyer,
Kiwamu Izumi
, et al. (19 additional authors not shown)
Abstract:
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrie…
▽ More
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrier to progress.
△ Less
Submitted 27 February, 2015; v1 submitted 20 February, 2015;
originally announced February 2015.
-
Parametric Instability in Long Optical Cavities and Suppression by Dynamic Transverse Mode Frequency Modulation
Authors:
Chunnong Zhao,
Li Ju,
Qi Fang,
Carl Blair,
Jiayi Qin,
David Blair,
Jerome Degallaix,
Hiroaki Yamamoto
Abstract:
Three mode parametric instability has been predicted in Advanced gravitational wave detectors. Here we present the first observation of this phenomenon in a large scale suspended optical cavity designed to be comparable to those of advanced gravitational wave detectors. Our results show that previous modelling assumptions that transverse optical modes are stable in frequency except for frequency d…
▽ More
Three mode parametric instability has been predicted in Advanced gravitational wave detectors. Here we present the first observation of this phenomenon in a large scale suspended optical cavity designed to be comparable to those of advanced gravitational wave detectors. Our results show that previous modelling assumptions that transverse optical modes are stable in frequency except for frequency drifts on a thermal deformation time scale is unlikely to be valid for suspended mass optical cavities. We demonstrate that mirror figure errors cause a dependence of transverse mode offset frequency on spot position. Combined with low frequency residual motion of suspended mirrors, this leads to transverse mode frequency modulation which suppresses the effective parametric gain. We show that this gain suppression mechanism can be enhanced by laser spot dithering or fast thermal modulation. Using Advanced LIGO test mass data and thermal modelling we show that gain suppression factors of 10-20 could be achieved for individual modes, sufficient to greatly ameliorate the parametric instability problem.
△ Less
Submitted 13 January, 2015; v1 submitted 7 January, 2015;
originally announced January 2015.
-
Observation of the Three-Mode Parametric Instability
Authors:
X. Chen,
C. Zhao,
S. Danilishin,
L. Ju,
D. Blair,
H. Wang,
S. P. Vyatchanin,
C. Molinelli,
A. Kuhn,
S. Gras,
T. Briant,
P. -F. Cohadon,
A. Heidmann,
I. Roch-Jeune,
R. Flaminio,
C. Michel,
L. Pinard
Abstract:
Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. Th…
▽ More
Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. They can pump energy into acoustic modes, leading to parametric instability, but they can also extract acoustic energy, leading to optomechanical cooling. We develop a large amplitude model of three-mode interactions that explains the ring-up amplitude saturation after instability occurs. We also demonstrate both radiation-pressure cooling and mechanical amplification in two different three-mode optomechanical systems, including the first observation of the three-mode parametric instability in a free-space Fabry-Perot cavity. The experimental data agrees well with the theoretical model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques to overcome instability.
△ Less
Submitted 11 November, 2014;
originally announced November 2014.
-
PandaX: A Liquid Xenon Dark Matter Experiment at CJPL
Authors:
X. G. Cao,
X. Chen,
Y. H. Chen,
X. Y. Cui,
D. Q. Fang,
C. B. Fu,
K. L. Giboni,
H. W. Gong,
G. D. Guo,
M. He,
J. Hu,
X. T. Huang,
X. D. Ji,
Y. L. Ju,
S. L. Li,
Q. Lin,
H. X. Liu,
J. L. Liu,
X. Liu,
W. Lorenzon,
Y. G. Ma,
Y. J. Mao,
K. X. Ni,
K. Pushkin,
X. X. Ren
, et al. (25 additional authors not shown)
Abstract:
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time proj…
▽ More
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.
△ Less
Submitted 12 May, 2014;
originally announced May 2014.
-
Three mode interaction noise in laser interferometer gravitational wave detectors
Authors:
Li Ju,
Chunnong Zhao,
Yiqiu Ma,
David. G. Blair,
Stefan. L. Danilishin,
Slawek Gras
Abstract:
Triply resonant three mode interactions in long optical cavities have been shown to lead to enhanced scattering of carrier light by the ultrasonic acoustic modes of the test mass mirrors. At high optical power, this can lead to parametric instability (parametric gain R > 1) for a few acoustic modes with strong spectral and spatial overlap. Numerous ?~10^3 acoustic modes of the test masses are pred…
▽ More
Triply resonant three mode interactions in long optical cavities have been shown to lead to enhanced scattering of carrier light by the ultrasonic acoustic modes of the test mass mirrors. At high optical power, this can lead to parametric instability (parametric gain R > 1) for a few acoustic modes with strong spectral and spatial overlap. Numerous ?~10^3 acoustic modes of the test masses are predicted to have R > 10^2. Experimental studies have shown that such modes also strongly scatter the carrier light, enabling very sensitive readout of the acoustic modes. The 3-mode scattering from the thermal fluctuation of large population of ultrasonic modes would causes random changes in occupation number of the carrier light and cavity transverse optical modes. Because the thermal fluctuation time scale (set by the acoustic mode relaxation times) is typically a few seconds, the noise spectrum from thermally induced photon number fluctuations is strongly peaked at low frequency. The noise level depends on the acoustic mode structure and acoustic losses of the test masses, the transverse optical mode spectrum of the optical cavities and on the test mass temperature. We theoretically investigate the possible effect of this noise and show that in advanced detectors under construction three mode interaction noise is below the standard quantum limit, but could set limits on future low frequency detectors that aim to exceed the free mass standard quantum limit.
△ Less
Submitted 7 March, 2014;
originally announced March 2014.
-
Three Mode Interactions as a Precision Monitoring Tool for Advanced Laser Interferometers
Authors:
L Ju,
C Zhao,
D G Blair,
S Susmithan,
Q Fang,
C D Blair
Abstract:
Three-mode opto-acoustic interactions in advanced laser interferometer gravitational wave detectors have high sensitivity to thermally excited ultrasonic modes in their test masses. Three mode interaction signal gain can change by 100% for thermally induced radius of curvature variations ~ 10-5, allowing the monitoring of thermal distortions corresponding to wavefront changes ~2 x 10-13m. We show…
▽ More
Three-mode opto-acoustic interactions in advanced laser interferometer gravitational wave detectors have high sensitivity to thermally excited ultrasonic modes in their test masses. Three mode interaction signal gain can change by 100% for thermally induced radius of curvature variations ~ 10-5, allowing the monitoring of thermal distortions corresponding to wavefront changes ~2 x 10-13m. We show that the three-mode gain for single cavity interactions can be monitored by observing beat signals in the transmitted or reflected light due to the thermal excitation of the many hundreds of detectable acoustic modes. We show that three mode interaction signals can be used at low optical power to predict parametric instabilities that could occur at higher power. In addition, at any power, the observed mode amplitudes can be used to control the interferometer operating point against slow environmental perturbations. We summarize data on an 80m cavity that demonstrates these effects and propose testing on full scale interferometer cavities to evaluate whether the technique has practical benefits that can be extended from single cavities to dual recycling interferometers.
△ Less
Submitted 20 February, 2014;
originally announced February 2014.
-
Radiation pressure excitation of test mass ultrasonic modes via three mode opto-acoustic interactions in a suspended Fabry-Perot cavity
Authors:
Carl Blair,
Sunil Susmithian,
Chunnong Zhao,
Fang Qi,
Li Ju,
David Blair
Abstract:
Three-mode parametric-instabilities risk stable operation of gravitational-wave detectors. Instabilities occur through time varying radiation-pressure distributions, derived from beating between two optical modes, exciting mirror acoustic modes in Fabry-Perot cavities. Here we report the first demonstration of radiation-pressure driving of ultrasonic-acoustic modes via pairs of optical modes in gr…
▽ More
Three-mode parametric-instabilities risk stable operation of gravitational-wave detectors. Instabilities occur through time varying radiation-pressure distributions, derived from beating between two optical modes, exciting mirror acoustic modes in Fabry-Perot cavities. Here we report the first demonstration of radiation-pressure driving of ultrasonic-acoustic modes via pairs of optical modes in gravitational-wave type optical cavities. In this experiment ~0.4W of TEM01 mode and ~1kW of TEM00 mode circulated inside the cavity, an ~181.6kHz excitation was observed with amplitude ~5E-13m. The results verify the driving force term in Braginsky's parametric instability feedback model. The interaction parametric gain was (3.8+/-0.5)E-3 and mass-ratio scaled opto-acoustic overlap 2.7+/-0.4.
△ Less
Submitted 8 April, 2013;
originally announced April 2013.
-
High quality factor mg-scale silicon mechanical resonators for 3-mode optoacoustic parametric amplifiers
Authors:
Francis Achilles Torres,
Phillip Meng,
Li Ju,
Chunnong Zhao,
David Gerald Blair,
Kai-Yu Liu,
Shiuh Chao,
Mariusz Martyniuk,
Isabelle Roch-Jeune,
Raffaele Flaminio,
Christophe Michel
Abstract:
Milligram-scale resonators have been shown to be suitable for the creation of 3-mode optoacoustic parametric amplifiers, based on a phenomena first predicted for advanced gravitational-wave detectors. To achieve practical optoacoustic parametric amplification, high quality factor resonators are required. We present millimetre-scale silicon resonators designed to exhibit a torsional vibration mode…
▽ More
Milligram-scale resonators have been shown to be suitable for the creation of 3-mode optoacoustic parametric amplifiers, based on a phenomena first predicted for advanced gravitational-wave detectors. To achieve practical optoacoustic parametric amplification, high quality factor resonators are required. We present millimetre-scale silicon resonators designed to exhibit a torsional vibration mode with a frequency in the 10^5 - 10^6 Hz range, for observation of 3-mode optoacoustic interactions in a compact table-top system. Our design incorporates an isolation stage and minimizes the acoustic loss from optical coating. We observe a quality factor of 7.5 x 10^5 for a mode frequency of 401.5 kHz, at room temperature and pressure of 10^-3 Pa. We confirmed the mode shape by mapping the amplitude response across the resonator and comparing to finite element modelling. This study contributes towards the development of 3-mode optoacoustic parametric amplifiers for use in novel high-sensitivity signal transducers and quantum measurement experiments.
△ Less
Submitted 24 March, 2013;
originally announced March 2013.
-
Observation of Three-Mode Parametric Instability
Authors:
Xu Chen,
Chunnong Zhao,
Li Ju,
Stefan Danilishin,
David Blair,
Haibo Wang,
Sergey P. Vyatchanin
Abstract:
Three-mode parametric interactions can occur in triply-resonant opto-mechanical systems in which two orthogonal optical modes are coupled with an appropriate mechanical mode. Using an optical cavity with a membrane inside, we report the first observation of three-mode parametric instability in a Fabry-Perot cavity, a phenomenon predicted to occur in long baseline advanced gravitational wave detect…
▽ More
Three-mode parametric interactions can occur in triply-resonant opto-mechanical systems in which two orthogonal optical modes are coupled with an appropriate mechanical mode. Using an optical cavity with a membrane inside, we report the first observation of three-mode parametric instability in a Fabry-Perot cavity, a phenomenon predicted to occur in long baseline advanced gravitational wave detectors. We present a large signal model for the phenomenon, which predicts exponential growth of mechanical oscillation followed by saturation. Our experimental results are consistent with this model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques in Advanced gravitational wave detectors.
△ Less
Submitted 4 July, 2013; v1 submitted 19 March, 2013;
originally announced March 2013.
-
Three-mode opto-acoustic parametric interactions with coupled cavity
Authors:
H. Miao,
C. Zhao,
L. Ju,
S. Gras,
P. Barriga,
Z. Zhang,
D. G. Blair
Abstract:
We theoretically analyze three-mode opto-acoustic parametric interactions in a coupled Fabry-Perot cavity, where one acoustic mode interacts with two optical modes. We show explicitly that extra degrees of freedom in a coupled cavity allow explorations of both parametric instability and cooling regimes with high parametric gain in a single table top experiment. This work can motivate experimenta…
▽ More
We theoretically analyze three-mode opto-acoustic parametric interactions in a coupled Fabry-Perot cavity, where one acoustic mode interacts with two optical modes. We show explicitly that extra degrees of freedom in a coupled cavity allow explorations of both parametric instability and cooling regimes with high parametric gain in a single table top experiment. This work can motivate experimental realizations of the three-mode parametric instability which might be an issue in next-generation gravitational-wave detectors with high optical-power cavities, helping in the development of better models, and in developing techniques for controls. In addition, we show that the same scheme can be implemented in the resolved-sideband acoustic-mode cooling.
△ Less
Submitted 8 November, 2008; v1 submitted 24 February, 2008;
originally announced February 2008.
-
Direct string magnetic gradiometer for space applications
Authors:
Andrew Sunderland,
Alexey V. Veryaskin,
Wayne McRae,
Li Ju,
David G. Blair
Abstract:
Recently, a novel Direct String Magnetic Gradiometer (DSMG) has been developed, where a vibrating wire, driven by an AC current, is used as a single sensitive element. It is designed to directly measure the local off-diagonal components of the magnetic gradient tensor, Bxz, Byz and Bxy, provided the distance to an object creating magnetic anomalies is much larger than the length of the string. T…
▽ More
Recently, a novel Direct String Magnetic Gradiometer (DSMG) has been developed, where a vibrating wire, driven by an AC current, is used as a single sensitive element. It is designed to directly measure the local off-diagonal components of the magnetic gradient tensor, Bxz, Byz and Bxy, provided the distance to an object creating magnetic anomalies is much larger than the length of the string. This requirement is well satisfied in space, if the sensor is deployed from a satellite platform orbiting near the planet under surveillance. Current instruments operating at $1{kPa}$ pressure achieve sensitivity of $1.8 \times 10^{-10}{T}/{m}$ in the band $0.0001{Hz}$ to $0.1{Hz}$. In this paper we show that proposed modifications to the current gradiometer design, specifically aimed at the deployment in space, could have a magnetic gradient sensitivity better than $10^{-13}{T}/{m}/\sqrt{Hz}$ in the frequency range of interest for specific missions both for fundamental research and for such applications as geophysical exploration on Mars and other solar system planets. Also, by combining a few single-axis magnetic gradiometer modules, it is possible to deploy a full tensor magnetic gradiometer.
△ Less
Submitted 8 January, 2008;
originally announced January 2008.