-
Forward scattering effects on muon imaging
Authors:
H. Gómez,
D. Gibert,
C. Goy,
K. Jourde,
Y. Karyotakis,
S. Katsanevas,
J. Marteau,
M. Rosas-Carbajal,
A. Tonazzo
Abstract:
Muon imaging is one of the most promising non-invasive techniques for density structure scanning, specially for large objects reaching the kilometre scale. It has already interesting applications in different fields like geophysics or nuclear safety and has been proposed for some others like engineering or archaeology. One of the approaches of this technique is based on the well-known radiography…
▽ More
Muon imaging is one of the most promising non-invasive techniques for density structure scanning, specially for large objects reaching the kilometre scale. It has already interesting applications in different fields like geophysics or nuclear safety and has been proposed for some others like engineering or archaeology. One of the approaches of this technique is based on the well-known radiography principle, by reconstructing the incident direction of the detected muons after crossing the studied objects. In this case, muons detected after a previous forward scattering on the object surface represent an irreducible background noise, leading to a bias on the measurement and consequently on the reconstruction of the object mean density. Therefore, a prior characterization of this effect represents valuable information to conveniently correct the obtained results. Although the muon scattering process has been already theoretically described, a general study of this process has been carried out based on Monte Carlo simulations, resulting in a versatile tool to evaluate this effect for different object geometries and compositions. As an example, these simulations have been used to evaluate the impact of forward scattered muons on two different applications of muon imaging: archaeology and volcanology, revealing a significant impact on the latter case. The general way in which all the tools used have been developed can allow to make equivalent studies in the future for other muon imaging applications following the same procedure.
△ Less
Submitted 13 December, 2017; v1 submitted 15 September, 2017;
originally announced September 2017.
-
Three-dimensional density structure of La Soufrieère de Guadeloupe lava dome from simultaneous muon radiographies and gravity data
Authors:
Marina Rosas-Carbajal,
Kevin Jourde,
Jacques Marteau,
Sébastien Deroussi,
Jean-Christophe Komorowski,
Dominique Gibert
Abstract:
Muon imaging has recently emerged as a powerful method to complement standard geophysical tools in the understanding of the Earth's subsurface. Muon measurements can yield a radiography of the average density along the muon path, allowing to image large volumes of a geological body from a single observation point. Here we jointly invert muon data from three simultaneous telescope acquisitions toge…
▽ More
Muon imaging has recently emerged as a powerful method to complement standard geophysical tools in the understanding of the Earth's subsurface. Muon measurements can yield a radiography of the average density along the muon path, allowing to image large volumes of a geological body from a single observation point. Here we jointly invert muon data from three simultaneous telescope acquisitions together with gravity data to estimate the three-dimensional density structure of the La Soufrière de Guadeloupe lava Dome. Our unique dataset allows us to achieve an unprecedented spatial resolution with this novel technique. The retrieved density model reveals an extensive, low-density anomaly where the most active part of the volcanic hydrothermal system is located, supporting previous studies that indicate this region as the most likely to be involved in a partial edifice collapse.
△ Less
Submitted 9 July, 2017;
originally announced July 2017.
-
DIAPHANE: Muon tomography applied to volcanoes, civil engineering, archaelogy
Authors:
Jacques Marteau,
Jean de Bremond d'Ars,
Dominique Gibert,
Kevin Jourde,
Jean-Christophe Ianigro,
Bruno Carlus
Abstract:
Muography techniques applied to geological structures greatly improved in the past ten years. Recent applications demonstrate the interest of the method not only to perform structural imaging but also to monitor the dynamics of inner movements like magma ascent inside volcanoes or density variations in hydrothermal systems. Muography time-resolution has been studied thanks to dedicated experiments…
▽ More
Muography techniques applied to geological structures greatly improved in the past ten years. Recent applications demonstrate the interest of the method not only to perform structural imaging but also to monitor the dynamics of inner movements like magma ascent inside volcanoes or density variations in hydrothermal systems. Muography time-resolution has been studied thanks to dedicated experiments, e.g. in a water tower tank. This paper presents the activities of the DIAPHANE collaboration between particle- and geo-physicists and the most recent results obtained in the field of volcanology, with a focus on the main target, the Soufrière of Guadeloupe active volcano. Special emphasis is given on the monitoring of the dome's inner volumes opacity variations, that could be inferred to the hydrothermal system dynamics (vaporization of inner liquid water in coincidence with the appearance of new fumaroles at the summit). I also breifly present results obtained in the fields of civil engineering (study of urban underground tunnels) and archaelogy (greek tumulus scanning).
△ Less
Submitted 12 December, 2016;
originally announced December 2016.
-
Muon dynamic radiography of density changes induced by hydrothermal activity at the La Soufrière of Guadeloupe volcano
Authors:
Kevin Jourde,
Dominique Gibert,
Jacques Marteau,
Jean de Bremond d'Ars,
Jean-Christophe Komorowski
Abstract:
Imaging geological structures through cosmic muon radiography is a newly developed technique particularly interesting in volcanology. Here we show that muon radiography may be efficient to detect and characterize mass movements in shallow hydrothermal systems of low-energy active volcanoes like the La Soufrière lava dome. We present an experiment conducted on this volcano during the Summer $2014$…
▽ More
Imaging geological structures through cosmic muon radiography is a newly developed technique particularly interesting in volcanology. Here we show that muon radiography may be efficient to detect and characterize mass movements in shallow hydrothermal systems of low-energy active volcanoes like the La Soufrière lava dome. We present an experiment conducted on this volcano during the Summer $2014$ and bring evidence that huge density changes occurred in three domains of the lava dome. Depending on their position and on the medium porosity the volumes of these domains vary from $1 \times 10^6 \; \mathrm{m}^3$ to $7 \times 10^6 \; \mathrm{m}^3$. However, the mass changes remain quite constant, two of them being negative ($Δm \approx -0.6 \times 10^9 \; \mathrm{kg}$) and a third one being positive ($Δm \approx +2 \times 10^9 \; \mathrm{kg}$). We attribute the negative mass changes to the formation of steam in shallow hydrothermal reservoir previously partly filled with liquid water. This coincides with the apparition of new fumaroles on top of the volcano. The positive mass change is synchronized with the negative mass changes indicating that liquid water probably flowed from the two reservoirs invaded by steam toward the third reservoir.
△ Less
Submitted 10 June, 2016; v1 submitted 9 June, 2016;
originally announced June 2016.
-
Muon tomography applied to active volcanoes
Authors:
Jacques Marteau,
Bruno Carlus,
Dominique Gibert,
Jean-Christophe Ianigro,
Kevin Jourde,
Bruno Kergosien,
Pascal Rolland
Abstract:
Muon tomography is a generic imaging method using the differential absorption of cosmic muons by matter. The measured contrast in the muons flux reflects the matter density contrast as it does in conventional medical imaging. The applications to volcanology present may advantadges induced by the features of the target itself: limited access to dangerous zones, impossible use of standard boreholes…
▽ More
Muon tomography is a generic imaging method using the differential absorption of cosmic muons by matter. The measured contrast in the muons flux reflects the matter density contrast as it does in conventional medical imaging. The applications to volcanology present may advantadges induced by the features of the target itself: limited access to dangerous zones, impossible use of standard boreholes information, harsh environmental conditions etc. The Diaphane project is one of the largest and leading collaboration in the field and the present article summarizes recent results collected on the Lesser Antilles, with a special emphasis on the Soufrière of Guadeloupe.
△ Less
Submitted 18 October, 2015;
originally announced October 2015.
-
Monitoring temporal opacity fluctuations of large structures with muon tomography : a calibration experiment using a water tower tank
Authors:
Kevin Jourde,
Dominique Gibert,
Jacques Marteau,
Jean de Bremond d'Ars,
Serge Gardien,
Claude Girerd,
Jean-Christophe Ianigro
Abstract:
Usage of secondary cosmic muons to image the geological structures density distribution significantly developed during the past ten years. Recent applications demonstrate the method interest to monitor magma ascent and volcanic gas movements inside volcanoes. Muon radiography could be used to monitor density variations in aquifers and the critical zone in the near surface. However, the time resolu…
▽ More
Usage of secondary cosmic muons to image the geological structures density distribution significantly developed during the past ten years. Recent applications demonstrate the method interest to monitor magma ascent and volcanic gas movements inside volcanoes. Muon radiography could be used to monitor density variations in aquifers and the critical zone in the near surface. However, the time resolution achievable by muon radiography monitoring remains poorly studied. It is biased by fluctuation sources exterior to the target, and statistically affected by the limited number of particles detected during the experiment. The present study documents these two issues within a simple and well constrained experimental context: a water tower. We use the data to discuss the influence of atmospheric variability that perturbs the signal, and propose correction formulas to extract the muon flux variations related to the water level changes. Statistical developments establish the feasibility domain of muon radiography monitoring as a function of target thickness (i.e. opacity). Objects with a thickness comprised between $\simeq$ 50 $\pm$ 30m water equivalent correspond to the best time resolution. Thinner objects have a degraded time resolution that strongly depends on the zenith angle, whereas thicker objects (like volcanoes) time resolution does not.
△ Less
Submitted 19 March, 2016; v1 submitted 9 April, 2015;
originally announced April 2015.
-
Joint inversion of muon tomography and gravimetry - a resolving kernel approach
Authors:
Kevin Jourde,
Dominique Gibert,
Jacques Marteau
Abstract:
Both muon tomography and gravimetry are geophysical methods that provide information on the density structure of the Earth's subsurface. Muon tomography measures the natural flux of cosmic muons and its attenuation produced by the screening effect of the rock mass to image. Gravimetry generally consists in measurements of the vertical component of the local gravity field. Both methods are linearly…
▽ More
Both muon tomography and gravimetry are geophysical methods that provide information on the density structure of the Earth's subsurface. Muon tomography measures the natural flux of cosmic muons and its attenuation produced by the screening effect of the rock mass to image. Gravimetry generally consists in measurements of the vertical component of the local gravity field. Both methods are linearly linked to density, but their spatial sensitivity is very different. Muon tomography essentially works like medical X-ray scan and integrates density information along elongated narrow conical volumes while gravimetry measurements are linked to density by a 3-dimensional integral encompassing the whole studied domain. We develop the mathematical expressions of these integration formulas -- called acquisition kernels -- to express resolving kernels that act as spatial filters relating the true unknown density structure to the density distribution actually recoverable from the available data. The resolving kernels provide a tool to quantitatively describe the resolution of the density models and to evaluate the resolution improvement expected by adding new data in the inversion. The resolving kernels derived in the joined muon/gravimetry case indicate that gravity data are almost useless to constrain the density structure in regions sampled by more than two muon tomography acquisitions. Interestingly the resolution in deeper regions not sampled by muon tomography is significantly improved by joining the two techniques. Examples taken from field experiments performed on La Soufrière of Guadeloupe volcano are discussed.
△ Less
Submitted 19 November, 2014;
originally announced November 2014.
-
Implementation of sub-nanoseconds TDC in FPGA: applications to time-of-flight analysis in muon radiography
Authors:
J. Marteau,
J. De Bremond D'ars,
D. Gibert,
K. Jourde,
S. Gardien,
C. Girerd,
J. -C. Ianigro
Abstract:
Time-of-flight (tof) techniques are standard techniques in high energy physics to determine particles propagation directions. Since particles velocities are generally close to c, the speed of light, and detectors typical dimensions at the meter level, the state-of-the-art tof techniques should reach sub-nanosecond timing resolution. Among the various techniques already available, the recently deve…
▽ More
Time-of-flight (tof) techniques are standard techniques in high energy physics to determine particles propagation directions. Since particles velocities are generally close to c, the speed of light, and detectors typical dimensions at the meter level, the state-of-the-art tof techniques should reach sub-nanosecond timing resolution. Among the various techniques already available, the recently developed ring oscillator TDC ones, implemented in low cost FPGA, feature a very interesting figure of merit since a very good timing performance may be achieved with limited processing ressources. This issue is relevant for applications where unmanned sensors should have the lowest possible power consumption. Actually this article describes in details the application of this kind of tof technique to muon tomography of geological bodies. Muon tomography aims at measuring density variations and absolute densities through the detection of atmospheric muons flux's attenuation, due to the presence of matter. When the measured fluxes become very low, an identified source of noise comes from backwards propagating particles hitting the detector in a direction pointing to the geological body. The separation between through-going and backward-going particles, on the basis of the tof information is therefore a key parameter for the tomography analysis and subsequent previsions.
△ Less
Submitted 16 October, 2013;
originally announced October 2013.
-
Effects of upward-going cosmic muons on density radiography of volcanoes
Authors:
K. Jourde,
D. Gibert,
J. Marteau,
J. De Bremond D'ars,
S. Gardien,
C. Girerd,
J. -C. Ianigro,
D. Carbone
Abstract:
Muon tomography aims at deriving the density structure of geological bodies from their screening attenuation produced on the natural cosmic muons flux. Because of their open-sky exposure, muons telescopes are subject to noise fluxes with large intensities relative to the tiny flux of interest. A recognized source of noise flux comes from fake tracks caused by particles that fortuitously trigger th…
▽ More
Muon tomography aims at deriving the density structure of geological bodies from their screening attenuation produced on the natural cosmic muons flux. Because of their open-sky exposure, muons telescopes are subject to noise fluxes with large intensities relative to the tiny flux of interest. A recognized source of noise flux comes from fake tracks caused by particles that fortuitously trigger the telescope detectors at the same time. Such a flux may be reduced by using multiple-detector telescopes so that fortuitous events become very unlikely. In the present study, we report on a different type of noise flux caused by upward-going muons crossing the detectors from the rear side. We describe field experiments on La Soufriére of Guadeloupe and Mount Etna, and give details on the high-resolution clocking system and the statistical procedure necessary to detect upward-going muons. We analyse several data sets acquired either in calibration or in volcano tomography situation. All data sets are shown clearly biased by upward-going noise flux whose intensity may amount to 50% of the measured total flux in given directions. Biases produced on density radiographies by this kind of flux are quantified and correction procedures are detailed. Examples for La Soufriére and Mount Etna are given.
△ Less
Submitted 25 July, 2013;
originally announced July 2013.