-
Performance of the MORA Apparatus for Testing Time-Reversal Invariance in Nuclear Beta Decay
Authors:
N. Goyal,
A. Singh,
S. Daumas-Tschopp,
L. M. Motilla Martinez,
G. Ban,
V. Bosquet,
J. F. Cam,
P. Chauveau,
S. Chinthakayala,
G. Fremont,
R. P. De Groote,
F. de Oliveira Santos,
T. Eronen,
A. Falkowski,
X. Flechard,
Z. Ge,
M. Gonzalez-Alonso,
H. Guerin,
L. Hayen,
A. Jaries,
M. Jbayli,
A. Jokinen,
A. Kankainen,
B. Kootte,
R. Kronholm
, et al. (18 additional authors not shown)
Abstract:
The MORA experimental setup is designed to measure the triple-correlation D parameter in nuclear beta decay. The D coefficient is sensitive to possible violations of time-reversal invariance. The experimental configuration consists of a transparent Paul trap surrounded by a detection setup with alternating beta and recoil-ion detectors. The octagonal symmetry of the detection setup optimizes the s…
▽ More
The MORA experimental setup is designed to measure the triple-correlation D parameter in nuclear beta decay. The D coefficient is sensitive to possible violations of time-reversal invariance. The experimental configuration consists of a transparent Paul trap surrounded by a detection setup with alternating beta and recoil-ion detectors. The octagonal symmetry of the detection setup optimizes the sensitivity of positron-recoil-ion coincidence rates to the D correlation, while reducing systematic effects. MORA utilizes an innovative in-trap laser polarization technique. The design and performance of the ion trap, associated beamline elements, lasers and beta and recoil-ion detectors, are presented. Recent progress towards the polarization proof-of-principle is described.
△ Less
Submitted 22 April, 2025;
originally announced April 2025.
-
High-precision measurement of the atomic mass of $^{84}$Sr and implications to isotope shift studies
Authors:
Zhuang Ge,
Shiwei Bai,
Tommi Eronen,
Ari Jokinen,
Anu Kankainen,
Sonja Kujanpää,
Iain Moore,
Dmitrii Nesterenko,
Mikael Reponen
Abstract:
The absolute mass of $^{84}$Sr was determined using the phase-imaging ion-cyclotron-resonance technique with the JYFLTRAP double Penning trap mass spectrometer. A more precise value for the mass of $^{84}$Sr is essential for providing potential indications of physics beyond the Standard Model through high-precision isotope shift measurements of Sr atomic transition frequencies. The mass excess of…
▽ More
The absolute mass of $^{84}$Sr was determined using the phase-imaging ion-cyclotron-resonance technique with the JYFLTRAP double Penning trap mass spectrometer. A more precise value for the mass of $^{84}$Sr is essential for providing potential indications of physics beyond the Standard Model through high-precision isotope shift measurements of Sr atomic transition frequencies. The mass excess of $^{84}$Sr was refined to be -80649.229(37) keV/c$^2$ from high-precision cyclotron-frequency-ratio measurements with a relative precision of 4.8$\times$10$^{-10}$. The obtained mass-excess value is in agreement with the adopted value in the Atomic Mass Evaluation 2020, but is 30 times more precise. With this new value, we confirm the previously observed nonlinearity in the study of the isotope shift of strontium. Moreover, the double-beta ($2β^{+}$) decay $Q$ value of $^{84}$Sr was directly determined to be 1790.115(37) keV, and the precision was improved by a factor of 30.
△ Less
Submitted 22 June, 2024; v1 submitted 2 April, 2024;
originally announced April 2024.
-
A new off-line ion source facility at IGISOL
Authors:
M. Vilén,
L. Canete,
B. Cheal,
A. Giatzoglou,
R. de Groote,
A. de Roubin,
T. Eronen,
S. Geldhof,
A. Jokinen,
A. Kankainen,
I. D. Moore,
D. A. Nesterenko,
H. Penttilä,
I. Pohjalainen,
M. Reponen,
S. Rinta-Antila
Abstract:
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap…
▽ More
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap mass measurements, laser spectroscopy and atom trap experiments.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
The MORA project
Authors:
P. Delahaye,
E. Liénard,
I. Moore,
M. Benali,
M. L. Bissell,
L. Canete,
T. Eronen,
A. Falkowski,
X. Fléchard,
M. Gonzalez-Alonso,
W. Gins,
R. P. De Groote,
A. Jokinen,
A. Kankainen,
M. Kowalska,
N. Lecesne,
R. Leroy,
Y. Merrer,
G. Neyens,
F. De Oliveira Santos,
G. Quemener,
A. De Roubin,
B. -M. Retailleau,
T. Roger,
N. Severijns
, et al. (3 additional authors not shown)
Abstract:
The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of trapped and oriented ions. The D correlation offers the possibility to search for new CP-violating interactions, complementary to searches done at the LHC and with Electric Dipole Moments. Technically, MORA uses an inno…
▽ More
The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of trapped and oriented ions. The D correlation offers the possibility to search for new CP-violating interactions, complementary to searches done at the LHC and with Electric Dipole Moments. Technically, MORA uses an innovative in-trap orientation method which combines the high trapping efficiency of a transparent Paul trap with laser orientation techniques. The trapping, detection, and laser setups are under development, for first tests at the Accelerator laboratory, JYFL, in the coming years.
△ Less
Submitted 28 May, 2019; v1 submitted 7 December, 2018;
originally announced December 2018.
-
Characterization and performance of the DTAS detector
Authors:
V. Guadilla,
J. L. Tain,
A. Algora,
J. Agramunt,
J. Äystö,
J. A. Briz,
A. Cucoanes,
T. Eronen,
M. Estienne,
M. Fallot,
L. M. Fraile,
E. Ganioğlu,
W. Gelletly,
D. Gorelov,
J. Hakala,
A. Jokinen,
D. Jordan,
A. Kankainen,
V. Kolhinen,
J. Koponen,
M. Lebois,
L. Le Meur,
T. Martinez,
M. Monserrate,
A. Montaner-Pizá
, et al. (20 additional authors not shown)
Abstract:
DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which…
▽ More
DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of \b{eta}-delayed neutron emitting nuclei.
△ Less
Submitted 1 June, 2018;
originally announced June 2018.
-
Software-based discharge suppressor using an EPICS data acquisition system as a rapid prototype at the LIPAc beam extraction system
Authors:
R. Ichimiya,
A. Jokinen,
A. Marqueta,
B. Bolzon
Abstract:
Internal continuous discharge can rapidly damage high-current ion sources and their extraction systems composed of several electrodes at high voltage. To prevent this continuous discharge inside the extraction system, a rapid prototype using an Experimental Physics and Industrial Control System (EPICS) software system for data acquisition has been implemented. During commissioning of the 140 mA de…
▽ More
Internal continuous discharge can rapidly damage high-current ion sources and their extraction systems composed of several electrodes at high voltage. To prevent this continuous discharge inside the extraction system, a rapid prototype using an Experimental Physics and Industrial Control System (EPICS) software system for data acquisition has been implemented. During commissioning of the 140 mA deuterium electron cyclotron resonance ion source of the Linear IFMIF Prototype Accelerator (LIPAc), discharges were often observed during plasma tuning of the ion source and beam optics tuning of the extraction system. If such continuous discharge can be avoided, discharge-related damage such as melting electrode edges and holes in the boron nitride disk in the ion source can be minimized and thus an efficient machine operation can be achieved. A veto signal is output to the machine protection system, which is then in charge of the RF power shutdown of the ion source for a pre-determined time. The average reaction time of this system has been measured and is about 10 ms from discharge detection to RF power shutdown of the ion source with a 50 Hz sampling frequency. This is hundreds of times slower than hardware-based implementation. However, it prevents almost all continuous discharges at the LIPAc ion source and extraction system, and is still much faster than an operator's reaction time.
△ Less
Submitted 23 March, 2018;
originally announced March 2018.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI and Jyväskylä - a Development for the Super-FRS at FAIR
Authors:
F. García,
R. Turpeinen,
J. Äystö,
T. Grahn,
S. Rinta-Antila,
A. Jokinen,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
C. Caesar,
C. Simons,
C. J. Schmidt,
A. Prochazka,
J. Hoffmann,
I. Rusanov,
N. Kurz,
H. Heggen,
P. Strmen,
M. Pikna,
B. Sitar
Abstract:
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will d…
▽ More
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch will cool and store beams in the NESR ring. The main tasks for the Super-FRS beam diagnostics chambers will be for the set up and adjustment of the separator as well as to provide tracking and event-by-event particle identification. The Helsinki Institute of Physics, and the Detector Laboratory and Experimental Electronics at GSI are in a joint R&D of a GEM-TPC detector which could satisfy the requirements of such tracking detectors, in terms of tracking efficiency, space resolution, count rate capability and momenta resolution. The current prototype, which is the generation four of this type, is two GEM-TPCs in twin configuration inside the same vessel. This means that one of the GEM-TPC is flipped on the middle plane w.r.t. the other one. This chamber was tested at Jyväskylä accelerator with protons projectiles and at GSI with Uranium, fragments and Carbon beams during this year 2016.
△ Less
Submitted 22 November, 2017;
originally announced November 2017.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI - a Development for the Super-FRS at FAIR
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
J. Heino,
J. Äystö,
T. Grahn,
S. Rinta-Antilla,
A. Jokinen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
I. Kaufeld,
C. Caesar,
C. Simon,
M. kìs,
A. Prochazka,
C. Nociforo,
S. Pietri
, et al. (8 additional authors not shown)
Abstract:
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons
Authors:
V. Guadilla,
A. Algora,
J. L. Tain,
J. Agramunt,
J. Äystö,
J. A. Briz,
A. Cucoanes,
T. Eronen,
M. Estienne,
M. Fallot,
L. M. Fraile,
E. Ganioglu,
W. Gelletly,
D. Gorelov,
J. Hakala,
A. Jokinen,
D. Jordan,
A. Kankainen,
V. Kolhinen,
J. Koponen,
M. Lebois,
T. Martinez,
M. Monserrate,
A. Montaner-Pizá,
I. Moore
, et al. (17 additional authors not shown)
Abstract:
In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic \b{eta}-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimenta…
▽ More
In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic \b{eta}-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.