-
Centimeter-sized Objects at Micrometer Resolution: Extending Field-of-View in Wavefront Marker X-ray Phase-Contrast Tomography
Authors:
Dominik John,
Junan Chen,
Christoph Gaßner,
Sara Savatović,
Lisa Marie Petzold,
Sami Wirtensohn,
Mirko Riedel,
Jörg U. Hammel,
Julian Moosmann,
Felix Beckmann,
Matthias Wieczorek,
Julia Herzen
Abstract:
Recent advancements in propagation-based phase-contrast imaging, such as hierarchical imaging, have enabled the visualization of internal structures in large biological specimens and material samples. However, wavefront marker-based techniques, which provide quantitative electron density information, face challenges when imaging larger objects due to stringent beam stability requirements and poten…
▽ More
Recent advancements in propagation-based phase-contrast imaging, such as hierarchical imaging, have enabled the visualization of internal structures in large biological specimens and material samples. However, wavefront marker-based techniques, which provide quantitative electron density information, face challenges when imaging larger objects due to stringent beam stability requirements and potential structural changes in objects during longer measurements. Extending the fields-of-view of these methods is crucial for obtaining comparable quantitative results across beamlines and adapting to the smaller beam profiles of fourth-generation synchrotron sources. We introduce a novel technique combining an adapted eigenflat optimization with deformable image registration to address the challenges and enable quantitative high-resolution scans of centimeter-sized objects with micrometre resolution. We demonstrate the potential of the method by obtaining an electron density map of a rat brain sample 15 mm in diameter using speckle-based imaging, despite the limited horizontal field-of-view of 6 mm of the beamline (PETRA III, P05, operated by Hereon at DESY). This showcases the ability of the technique to significantly widen the range of application of wavefront marker-based techniques in both biological and materials science research.
△ Less
Submitted 1 August, 2024;
originally announced August 2024.
-
Wide Field of View Large Aperture Meta-Doublet Eyepiece
Authors:
Anna Wirth-Singh,
Johannes E. Fröch,
Fan Yang,
Louis Martin,
Hualiang Zhang,
Quentin T. Tanguy,
Zhihao Zhou,
Luocheng Huang,
Demis D. John,
Biljana Stamenic,
Juejun Hu,
Tian Gu,
Arka Majumdar
Abstract:
Wide field of view and light weight optics are critical for advanced eyewear, with applications in augmented/virtual reality and night vision. Conventional refractive lenses are often stacked to correct aberrations at wide field of view, leading to limited performance and increased size and weight. In particular, simultaneously achieving wide field of view and large aperture for light collection i…
▽ More
Wide field of view and light weight optics are critical for advanced eyewear, with applications in augmented/virtual reality and night vision. Conventional refractive lenses are often stacked to correct aberrations at wide field of view, leading to limited performance and increased size and weight. In particular, simultaneously achieving wide field of view and large aperture for light collection is desirable but challenging to realize in a compact form-factor. Here, we demonstrate a wide field of view (greater than 60$^\circ$) meta-optic doublet eyepiece with an entrance aperture of 2.1 cm. At the design wavelength of 633 nm, the meta-optic doublet achieves comparable performance to a refractive lens-based eyepiece system. This meta-doublet eyepiece illustrates the potential for meta-optics to play an important role in the development of high-quality monochrome near-eye display and night vision systems.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
The LHCb VELO Upgrade Module Construction
Authors:
K. Akiba,
M. Alexander,
C. Bertella,
A. Biolchini,
A. Bitadze,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
K. Bridges,
M. Brock,
A. T. Burke,
J. Buytaert,
W. Byczynski,
J. Carroll,
V. Coco,
P. Collins,
A. Davis,
O. De Aguiar Francisco,
K. De Bruyn,
S. De Capua,
K. De Roo,
F. Doherty,
L. Douglas,
L. Dufour,
R. Dumps
, et al. (62 additional authors not shown)
Abstract:
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon dete…
▽ More
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.
△ Less
Submitted 21 April, 2024;
originally announced April 2024.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Hierarchical surrogate-based Approximate Bayesian Computation for an electric motor test bench
Authors:
David N. John,
Livia Stohrer,
Claudia Schillings,
Michael Schick,
Vincent Heuveline
Abstract:
Inferring parameter distributions of complex industrial systems from noisy time series data requires methods to deal with the uncertainty of the underlying data and the used simulation model. Bayesian inference is well suited for these uncertain inverse problems. Standard methods used to identify uncertain parameters are Markov Chain Monte Carlo (MCMC) methods with explicit evaluation of a likelih…
▽ More
Inferring parameter distributions of complex industrial systems from noisy time series data requires methods to deal with the uncertainty of the underlying data and the used simulation model. Bayesian inference is well suited for these uncertain inverse problems. Standard methods used to identify uncertain parameters are Markov Chain Monte Carlo (MCMC) methods with explicit evaluation of a likelihood function. However, if the likelihood is very complex, such that its evaluation is computationally expensive, or even unknown in its explicit form, Approximate Bayesian Computation (ABC) methods provide a promising alternative. In this work both methods are first applied to artificially generated data and second on a real world problem, by using data of an electric motor test bench. We show that both methods are able to infer the distribution of varying parameters with a Bayesian hierarchical approach. But the proposed ABC method is computationally much more efficient in order to achieve results with similar accuracy. We suggest to use summary statistics in order to reduce the dimension of the data which significantly increases the efficiency of the algorithm. Further the simulation model is replaced by a Polynomial Chaos Expansion (PCE) surrogate to speed up model evaluations. We proof consistency for the proposed surrogate-based ABC method with summary statistics under mild conditions on the (approximated) forward model.
△ Less
Submitted 17 June, 2021;
originally announced June 2021.
-
Calibration and Performance of the NIKA2 camera at the IRAM 30-meter Telescope
Authors:
L. Perotto,
N. Ponthieu,
J. -F. Macías-Pérez,
R. Adam,
P. Ade,
P. André,
A. Andrianasolo,
H. Aussel,
A. Beelen,
A. Benoît,
S. Berta,
A. Bideaud,
O. Bourrion,
M. Calvo,
A. Catalano,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
P. García,
A. Gomez,
J. Goupy,
D. John,
F. Kéruzoré
, et al. (23 additional authors not shown)
Abstract:
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017…
▽ More
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017 and February 2018 that span the whole range of observing elevations and atmospheric conditions encountered at the IRAM 30-m telescope, we test the stability of the performance parameters. We report an instantaneous field of view (FOV) of 6.5' in diameter, filled with an average fraction of $84\%$ and $90\%$ of valid detectors at $150$ and $260\,\rm{GHz}$, respectively. The beam pattern is characterized by a FWHM of $17.6'' \pm 0.1''$ and $11.1''\pm 0.2''$, and a beam efficiency of $77\% \pm 2\%$ and $55\% \pm 3\%$ at $150$ and $260\,\rm{GHz}$, respectively. The rms calibration uncertainties are about $3\%$ at $150\,\rm{GHz}$ and $6\%$ at $260\,\rm{GHz}$. The absolute calibration uncertainties are of $5\%$ and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below $1\%$ in both channels. The noise equivalent flux density (NEFD) at $150$ and $260\,\rm{GHz}$ are of $9 \pm 1\, \rm{mJy}\cdot s^{1/2}$ and $30 \pm 3\, \rm{mJy}\cdot s^{1/2}$. This state-of-the-art performance confers NIKA2 with mapping speeds of $1388 \pm 174$ and $111 \pm 11 \,\rm{arcmin}^2\cdot \rm{mJy}^{-2}\cdot \rm{h}^{-1}$ at $150$ and $260\,\rm{GHz}$. With these unique capabilities of fast dual-band mapping at high (better that 18'') angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.
△ Less
Submitted 21 January, 2020; v1 submitted 4 October, 2019;
originally announced October 2019.