-
Emerging Frameworks for Objective Task-based Evaluation of Quantitative Medical Imaging Methods
Authors:
Yan Liu,
Huitian Xia,
Nancy A. Obuchowski,
Richard Laforest,
Arman Rahmim,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Quantitative imaging (QI) is demonstrating strong promise across multiple clinical applications. For clinical translation of QI methods, objective evaluation on clinically relevant tasks is essential. To address this need, multiple evaluation strategies are being developed. In this paper, based on previous literature, we outline four emerging frameworks to perform evaluation studies of QI methods.…
▽ More
Quantitative imaging (QI) is demonstrating strong promise across multiple clinical applications. For clinical translation of QI methods, objective evaluation on clinically relevant tasks is essential. To address this need, multiple evaluation strategies are being developed. In this paper, based on previous literature, we outline four emerging frameworks to perform evaluation studies of QI methods. We first discuss the use of virtual imaging trials (VITs) to evaluate QI methods. Next, we outline a no-gold-standard evaluation framework to clinically evaluate QI methods without ground truth. Third, a framework to evaluate QI methods for joint detection and quantification tasks is outlined. Finally, we outline a framework to evaluate QI methods that output multi-dimensional parameters, such as radiomic features. We review these frameworks, discussing their utilities and limitations. Further, we examine future research areas in evaluation of QI methods. Given the recent advancements in PET, including long axial field-of-view scanners and the development of artificial-intelligence algorithms, we present these frameworks in the context of PET.
△ Less
Submitted 6 July, 2025;
originally announced July 2025.
-
Development and in silico imaging trial evaluation of a deep-learning-based transmission-less attenuation compensation method for DaT SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Zekun Li,
Chunwei Ying,
Hongyu An,
Tammie L. S. Benzinger,
Richard Laforest,
Jingqin Luo,
Scott A. Norris,
Abhinav K. Jha
Abstract:
Quantitative measures of dopamine transporter (DaT) uptake in caudate, putamen, and globus pallidus derived from DaT-single-photon emission computed tomography (SPECT) images are being investigated as biomarkers to diagnose, assess disease status, and track the progression of Parkinsonism. Reliable quantification from DaT-SPECT images requires performing attenuation compensation (AC), typically wi…
▽ More
Quantitative measures of dopamine transporter (DaT) uptake in caudate, putamen, and globus pallidus derived from DaT-single-photon emission computed tomography (SPECT) images are being investigated as biomarkers to diagnose, assess disease status, and track the progression of Parkinsonism. Reliable quantification from DaT-SPECT images requires performing attenuation compensation (AC), typically with a separate X-ray CT scan. Such CT-based AC (CTAC) has multiple challenges, a key one being the non-availability of X-ray CT component on many clinical SPECT systems. Even when a CT is available, the additional CT scan leads to increased radiation dose, costs, and complexity, potential quantification errors due to SPECT-CT misalignment, and higher training and regulatory requirements. To overcome the challenges with the requirement of a CT scan for AC in DaT SPECT, we propose a deep learning (DL)-based transmission-less AC method for DaT-SPECT (DaT-CTLESS). An in silico imaging trial, titled ISIT-DaT, was designed to evaluate the performance of DaT-CTLESS on the regional uptake quantification task. We observed that DaT-CTLESS yielded a significantly higher correlation with CTAC than that between UAC and CTAC on the regional DaT uptake quantification task. Further, DaT-CLTESS had an excellent agreement with CTAC on this task, significantly outperformed UAC in distinguishing patients with normal versus reduced putamen SBR, yielded good generalizability across two scanners, was generally insensitive to intra-regional uptake heterogeneity, demonstrated good repeatability, exhibited robust performance even as the size of the training data was reduced, and generally outperformed the other considered DL methods on the task of quantifying regional uptake across different training dataset sizes. These results provide a strong motivation for further clinical evaluation of DaT-CTLESS.
△ Less
Submitted 25 June, 2025;
originally announced June 2025.
-
ISIT-GEN: An in silico imaging trial to assess the inter-scanner generalizability of CTLESS for myocardial perfusion SPECT on defect-detection task
Authors:
Zitong Yu,
Nu Ri Choi,
Zezhang Yang,
Nancy A. Obuchowski,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
A recently proposed scatter-window and deep learning-based attenuation compensation (AC) method for myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), namely CTLESS, demonstrated promising performance on the clinical task of myocardial perfusion defect detection with retrospective data acquired on SPECT scanners from a single vendor. For clinical translation…
▽ More
A recently proposed scatter-window and deep learning-based attenuation compensation (AC) method for myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), namely CTLESS, demonstrated promising performance on the clinical task of myocardial perfusion defect detection with retrospective data acquired on SPECT scanners from a single vendor. For clinical translation of CTLESS, it is important to assess the generalizability of CTLESS across different SPECT scanners. For this purpose, we conducted a virtual imaging trial, titled in silico imaging trial to assess generalizability (ISIT-GEN). ISIT-GEN assessed the generalizability of CTLESS on the cardiac perfusion defect detection task across SPECT scanners from three different vendors. The performance of CTLESS was compared with a standard-of-care CT-based AC (CTAC) method and a no-attenuation compensation (NAC) method using an anthropomorphic model observer. We observed that CTLESS had receiver operating characteristic (ROC) curves and area under the ROC curves similar to those of CTAC. Further, CTLESS was observed to significantly outperform the NAC method across three scanners. These results are suggestive of the inter-scanner generalizability of CTLESS and motivate further clinical evaluations. The study also highlights the value of using in silico imaging trials to assess the generalizability of deep learning-based AC methods feasibly and rigorously.
△ Less
Submitted 20 March, 2025;
originally announced March 2025.
-
An experimental technique for measuring radial coherence
Authors:
Radhika Prasad,
Nilakshi Senapati,
Suman Karan,
Abhinandan Bhattacharjee,
Bruno Piccirillo,
Miguel A. Alonso,
Anand K. Jha
Abstract:
Coherence refers to correlations between field vibrations at two separate points in degrees of freedom such as space, time, and polarisation. In the context of space, coherence theory has been formulated between two transverse positions which can be described either in the cartesian coordinates or in the cylindrical coordinates. When expressed in cylindrical coordinates, spatial coherence is descr…
▽ More
Coherence refers to correlations between field vibrations at two separate points in degrees of freedom such as space, time, and polarisation. In the context of space, coherence theory has been formulated between two transverse positions which can be described either in the cartesian coordinates or in the cylindrical coordinates. When expressed in cylindrical coordinates, spatial coherence is described in terms of azimuthal and radial coordinates. The description of spatial coherence in radial degree of freedom has been formulated only recently in JOSA A 40, 411 (2023). In the present article, we demonstrate an efficient experimental technique for measuring radial coherence, and we report measurement of radial coherence of two different types of radially partially coherent optical fields.
△ Less
Submitted 21 February, 2025;
originally announced February 2025.
-
Broadband uniform-efficiency OAM-mode detector
Authors:
Suman Karan,
Martin P. Van Exter,
Anand K. Jha
Abstract:
The high-dimensional basis of orbital angular momentum (OAM) has several added and unique advantages for photonics quantum technologies compared to the polarization basis, which is only two-dimensional. However, one of the major roadblocks in implementing OAM-based applications with their full potentials is the absence of an ideal OAM-mode detector. Despite the plethora of efforts in the last thre…
▽ More
The high-dimensional basis of orbital angular momentum (OAM) has several added and unique advantages for photonics quantum technologies compared to the polarization basis, which is only two-dimensional. However, one of the major roadblocks in implementing OAM-based applications with their full potentials is the absence of an ideal OAM-mode detector. Despite the plethora of efforts in the last three decades, currently, there is no OAM detector that can detect a broad OAM-mode spectrum, has uniform detection-efficiency over all the modes, measures the true spectrum, and works for an arbitrary quantum state without the need for any prior information. In this article, we experimentally demonstrate just such an OAM detector. We report detection of pure and mixed OAM states with fidelities more than 98% and with measurement times of only a few minutes for dimensionalities up to 100. We expect our work to substantially boost the OAM-based photonics quantum technology efforts.
△ Less
Submitted 20 February, 2025;
originally announced February 2025.
-
Efficient Monte Carlo Event Generation for Neutrino-Nucleus Exclusive Cross Sections
Authors:
Mathias El Baz,
Federico Sánchez,
Natalie Jachowicz,
Kajetan Niewczas,
Ashish Kumar Jha,
Alexis Nikolakopoulos
Abstract:
Modern neutrino-nucleus cross section predictions need to incorporate sophisticated nuclear models to achieve greater predictive precision. However, the computational complexity of these advanced models often limits their practicality for experimental analyses. To address this challenge, we introduce a new Monte Carlo method utilizing Normalizing Flows to generate surrogate cross sections that clo…
▽ More
Modern neutrino-nucleus cross section predictions need to incorporate sophisticated nuclear models to achieve greater predictive precision. However, the computational complexity of these advanced models often limits their practicality for experimental analyses. To address this challenge, we introduce a new Monte Carlo method utilizing Normalizing Flows to generate surrogate cross sections that closely approximate those of the original model while significantly reducing computational overhead. As a case study, we built a Monte Carlo event generator for the neutrino-nucleus cross section model developed by the Ghent group. This model employs a Hartree-Fock procedure to establish a quantum mechanical framework in which both the bound and scattering nucleon states are solutions to the mean-field nuclear potential. The surrogate cross sections generated by our method demonstrate excellent accuracy with a relative effective sample size of more than $98.4 \%$, providing a computationally efficient alternative to traditional Monte Carlo sampling methods for differential cross sections.
△ Less
Submitted 16 May, 2025; v1 submitted 20 February, 2025;
originally announced February 2025.
-
Two-electron one-photon process in collision of 1.8-2.1 MeV neon on aluminum
Authors:
Shashank Singh,
Narendra Kumar,
Soumya Chatterjee,
Deepak Swami,
Alok Kumar Singh Jha,
Mumtaz Oswal,
K. P. Singh,
T. Nandi
Abstract:
X-ray emissions due to the two-electron one-photon (TEOP) process in the neon projectile and aluminum target have been successfully observed for the beam energy window of 1.8-2.1 MeV. Experimental TEOP transition energies have been compared with theoretical predictions of flexible atomic structure code (FAC) and General-purpose Relativistic Atomic Structure (GRASP) package. Present results have be…
▽ More
X-ray emissions due to the two-electron one-photon (TEOP) process in the neon projectile and aluminum target have been successfully observed for the beam energy window of 1.8-2.1 MeV. Experimental TEOP transition energies have been compared with theoretical predictions of flexible atomic structure code (FAC) and General-purpose Relativistic Atomic Structure (GRASP) package. Present results have been verified with reported theoretical and experimental values. Transition rates of the TEOP transitions have also been studied using the said codes. The observed lines have been assigned when the measured transition energies are in good agreement with the theoretical values. Such assignments have further been validated with the good agreements between the experimental and theoretical transition rates. Note that only the TEOP lines in projectile ions are seen with 1.8 MeV energy. In contrast, the TEOP lines in target ions are also observed well with 2.1 MeV energy. Thus, this study sheds useful light on the excitation mechanism of the TEOP processes in the low energy regimes.
△ Less
Submitted 6 January, 2025;
originally announced January 2025.
-
The Soft-Membrane Surface Forces Apparatus
Authors:
Ilyes Jalisse,
Aditya Jha,
Lionel Buisson,
Frédéric Nallet,
Yacine Amarouchene,
Thomas Salez,
Carlos Drummond
Abstract:
Compliant walls are widespread in biological and engineering systems. Because of their singular nature, adapted tools are required to accurately study their rheological properties as well as the consequences of the latter within a given mechanical setting. Because of their slender nature, membranes can be considered as prototypical examples of highly compliant boundaries. In this study, we describ…
▽ More
Compliant walls are widespread in biological and engineering systems. Because of their singular nature, adapted tools are required to accurately study their rheological properties as well as the consequences of the latter within a given mechanical setting. Because of their slender nature, membranes can be considered as prototypical examples of highly compliant boundaries. In this study, we describe a modified Surface Forces Apparatus (SFA) developed to measure the forces acting on a compliant membrane by measuring its deformation field. We discuss how such a device can be used to characterize the rheology of suspended membranes and accurately measure the electrostatic interactions between a polarized membrane and a spherical electrode, without the need of an external measurement spring.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Structured position-momentum entangled two-photon fields
Authors:
Radhika Prasad,
Sanjana Wanare,
Suman Karan,
Mritunjay K. Joshi,
Abhinandan Bhattacharjee,
Anand K. Jha
Abstract:
Structured optical fields have led to several ground-breaking techniques in classical imaging and microscopy. At the same time, in the quantum domain, position-momentum entangled photon fields have been shown to have several unique features that can lead to beyond-classical imaging and microscopy capabilities. Therefore, it is natural to expect that position-momentum entangled two-photon fields th…
▽ More
Structured optical fields have led to several ground-breaking techniques in classical imaging and microscopy. At the same time, in the quantum domain, position-momentum entangled photon fields have been shown to have several unique features that can lead to beyond-classical imaging and microscopy capabilities. Therefore, it is natural to expect that position-momentum entangled two-photon fields that are structured can push the boundaries of quantum imaging and microscopy even further beyond. Nonetheless, the existing experimental schemes are able to produce either structured two-photon fields without position-momentum entanglement, or position-momentum entangled two-photon fields without structures. In this article, by manipulating the phase-matching condition of the spontaneous parametric down-conversion process, we report experimental generation of two-photon fields with various structures in their spatial correlations. We experimentally measure the minimum bound on the entanglement of formation and thereby verify the position-momentum entanglement of the structured two-photon field. We expect this work to have important implications for quantum technologies related to imaging and sensing.
△ Less
Submitted 14 December, 2024;
originally announced December 2024.
-
Taylor's swimming sheet near a soft boundary
Authors:
Aditya Jha,
Yacine Amarouchene,
Thomas Salez
Abstract:
In 1951, G.I. Taylor modeled swimming microorganisms by hypothesizing an infinite sheet in 2D moving in a viscous medium due to a wave passing through it. This simple model not only captured the ability of microorganisms to swim due to the wavy motion of a flagella, but further development into the model captured the optimal nature of metachronal waves observed in ciliates. While the additional ef…
▽ More
In 1951, G.I. Taylor modeled swimming microorganisms by hypothesizing an infinite sheet in 2D moving in a viscous medium due to a wave passing through it. This simple model not only captured the ability of microorganisms to swim due to the wavy motion of a flagella, but further development into the model captured the optimal nature of metachronal waves observed in ciliates. While the additional effects of nearby rigid boundaries and complex environments have been addressed, herein we explore the correction induced by a nearby soft boundary. Our simple model allows us to show that the magnitude of the swimming velocity gets modified near soft boundaries, and reduces for transverse waves while it increases for longitudinal waves. We further delve into the energetics of the process and the deformation of the corresponding soft boundary, highlighting the synchronization of the oscillations induced on the soft boundary with the waves passing through the sheet and the corresponding changes to the power exerted on the fluid.
△ Less
Submitted 3 October, 2024;
originally announced October 2024.
-
CTLESS: A scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Craig K. Abbey,
Richard Laforest,
Nancy A. Obuchowski,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by SPECT, typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis due to SPECT/CT misalignment. To address these issues, we developed a method for cardiac SPECT AC using dee…
▽ More
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by SPECT, typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis due to SPECT/CT misalignment. To address these issues, we developed a method for cardiac SPECT AC using deep learning and emission scatter-window photons without a separate transmission scan (CTLESS). In this method, an estimated attenuation map reconstructed from scatter-energy window projections is segmented into different regions using a multi-channel input multi-decoder network trained on CT scans. Pre-defined attenuation coefficients are assigned to these regions, yielding the attenuation map used for AC. We objectively evaluated this method in a retrospective study with anonymized clinical SPECT/CT stress MPI images on the clinical task of detecting defects with an anthropomorphic model observer. CTLESS yielded statistically non-inferior performance compared to a CT-based AC (CTAC) method and significantly outperformed a non-AC (NAC) method on this clinical task. Similar results were observed in stratified analyses with different sexes, defect extents and severities. The method was observed to generalize across two SPECT scanners, each with a different camera. In addition, CTLESS yielded similar performance as CTAC and outperformed NAC method on the metrics of root mean squared error and structural similarity index measure. Moreover, as we reduced the training dataset size, CTLESS yielded relatively stable AUC values and generally outperformed another DL-based AC method that directly estimated the attenuation coefficient within each voxel. These results demonstrate the capability of the CTLESS method for transmission-less AC in SPECT and motivate further clinical evaluation.
△ Less
Submitted 12 September, 2024;
originally announced September 2024.
-
Diverse Transient Chiral Dynamics in Evolutionary distinct Photosynthetic Reaction Centers
Authors:
Yonglei Yang,
Zihui Liu,
Fulu Zheng,
Panpan Zhang,
Hongxing He,
Ajay Jha,
Hong-Guang Duan
Abstract:
The evolution of photosynthetic reaction centers (RCs) from anoxygenic bacteria to oxygenic cyanobacteria and plants reflects their structural and functional adaptation to environmental conditions. Chirality plays a significant role in influencing the arrangement and function of key molecules in these RCs. This study investigates chirality-related energy transfer in two distinct RCs: Thermochromat…
▽ More
The evolution of photosynthetic reaction centers (RCs) from anoxygenic bacteria to oxygenic cyanobacteria and plants reflects their structural and functional adaptation to environmental conditions. Chirality plays a significant role in influencing the arrangement and function of key molecules in these RCs. This study investigates chirality-related energy transfer in two distinct RCs: Thermochromatium tepidum (BRC) and Thermosynechococcus vulcanus (PSII RC) using two-dimensional electronic spectroscopy (2DES). Circularly polarized laser pulses reveal transient chiral dynamics, with 2DCD spectroscopy highlighting chiral contributions. BRC displays more complex chiral behavior, while PSII RC shows faster coherence decay, possibly as an adaptation to oxidative stress. Comparing the chiral dynamics of BRC and PSII RC provides insights into photosynthetic protein evolution and function.
△ Less
Submitted 11 September, 2024;
originally announced September 2024.
-
Capillary lubrication of a spherical particle near a fluid interface
Authors:
Aditya Jha,
Yacine Amarouchene,
Thomas Salez
Abstract:
The lubricated motion of an object near a deformable boundary presents striking subtleties arising from the coupling between the elasticity of the boundary and lubricated flow, including but not limited to the emergence of a lift force acting on the object despite the zero Reynolds number. In this study, we characterize the hydrodynamic forces and torques felt by a sphere translating in close prox…
▽ More
The lubricated motion of an object near a deformable boundary presents striking subtleties arising from the coupling between the elasticity of the boundary and lubricated flow, including but not limited to the emergence of a lift force acting on the object despite the zero Reynolds number. In this study, we characterize the hydrodynamic forces and torques felt by a sphere translating in close proximity to a fluid interface, separating the viscous medium of the sphere's motion from an infinitely-more-viscous medium. We employ lubrication theory and perform a perturbation analysis in capillary compliance. The dominant response of the interface owing to surface tension results in a long-ranged interface deformation, which leads to a modification of the forces and torques with respect to the rigid reference case, that we characterise in details with scaling arguments and numerical integrations.
△ Less
Submitted 18 July, 2024;
originally announced July 2024.
-
Singular viscoelastic perturbation to soft lubrication
Authors:
Bharti Bharti,
Quentin Ferreira,
Aditya Jha,
Andreas Carlson,
David S. Dean,
Yacine Amarouchene,
Tak Shing Chan,
Thomas Salez
Abstract:
Soft lubrication has been shown to drastically affect the mobility of an object immersed in a viscous fluid in the vicinity of a purely elastic wall. In this theoretical study, we develop a minimal model incorporating viscoelasticity, carrying out a perturbation analysis in both the elastic deformation of the wall and its viscous damping. Our approach reveals the singular-perturbation nature of…
▽ More
Soft lubrication has been shown to drastically affect the mobility of an object immersed in a viscous fluid in the vicinity of a purely elastic wall. In this theoretical study, we develop a minimal model incorporating viscoelasticity, carrying out a perturbation analysis in both the elastic deformation of the wall and its viscous damping. Our approach reveals the singular-perturbation nature of viscoelasticity to soft lubrication. Numerical resolution of the resulting non-linear, singular and coupled equations of motion reveals peculiar effects of viscoelasticity on confined colloidal mobility, opening the way towards the description of complex migration scenarios near realistic polymeric substrates and biological membranes.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
Nuclear Medicine Artificial Intelligence in Action: The Bethesda Report (AI Summit 2024)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Guido Davidzon,
Joyita Dutta,
Georges El Fakhri,
Munir Ghesani,
Nicolas A. Karakatsanis,
Quanzheng Li,
Chi Liu,
Emilie Roncali,
Babak Saboury,
Tahir Yusufaly,
Abhinav K. Jha
Abstract:
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) em…
▽ More
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Observation of Brownian elastohydrodynamic forces acting on confined soft colloids
Authors:
Nicolas Fares,
Maxime Lavaud,
Zaicheng Zhang,
Aditya Jha,
Yacine Amarouchene,
Thomas Salez
Abstract:
Confined motions in complex environments are ubiquitous in microbiology. These situations invariably involve the intricate coupling between fluid flow, soft boundaries, surface forces and fluctuations. In the present study, such a coupling is investigated using a novel method combining holographic microscopy and advanced statistical inference. Specifically, the Brownian motion of softmicrometric o…
▽ More
Confined motions in complex environments are ubiquitous in microbiology. These situations invariably involve the intricate coupling between fluid flow, soft boundaries, surface forces and fluctuations. In the present study, such a coupling is investigated using a novel method combining holographic microscopy and advanced statistical inference. Specifically, the Brownian motion of softmicrometric oil droplets near rigid walls is quantitatively analyzed. All the key statistical observables are reconstructed with high precision, allowing for nanoscale resolution of local mobilities and femtonewton inference of conservative or non-conservative forces. Strikingly, the analysis reveals the existence of a novel, transient, but large, soft Brownian force. The latter might be of crucial importance for microbiological and nanophysical transport, target finding or chemical reactions in crowded environments, and hence the whole life machinery.
△ Less
Submitted 22 May, 2024;
originally announced May 2024.
-
A wavefront rotator with near-zero mean polarization change
Authors:
Suman Karan,
Nilakshi Senapati,
Anand K. Jha
Abstract:
A K-mirror is a device that rotates the wavefront of an incident optical field. It has recently gained prominence over Dove prism, another commonly used wavefront rotator, due to the fact that while a K-mirror has several controls for adjusting the internal reflections, a Dove prism is made of a single glass element with no additional control. Thus, one can obtain much lower angular deviations of…
▽ More
A K-mirror is a device that rotates the wavefront of an incident optical field. It has recently gained prominence over Dove prism, another commonly used wavefront rotator, due to the fact that while a K-mirror has several controls for adjusting the internal reflections, a Dove prism is made of a single glass element with no additional control. Thus, one can obtain much lower angular deviations of transmitting wavefronts using a K-mirror than with a Dove prism. However, the accompanying polarization changes in the transmitted field due to rotation persist even in the commercially available K-mirrors. A recent theoretical work [Applied Optics, 61, 8302 (2022)] shows that it is possible to optimize the base angle of a K-mirror for a given refractive index such that the accompanying polarization changes are minimum. In contrast, we show in this article that by optimizing the refractive index it is possible to design a K-mirror at any given base angle and with any given value for the mean polarization change, including near-zero values. Furthermore, we experimentally demonstrate a K-mirror with an order-of-magnitude lower mean polarization change than that of the commercially available K-mirrors. This can have important practical implications for OAM-based applications that require precise wavefront rotation control.
△ Less
Submitted 17 May, 2024;
originally announced May 2024.
-
Capillary-lubrication force between rotating cylinders separated by a fluid interface
Authors:
Aditya Jha,
Yacine Amarouchene,
Thomas Salez
Abstract:
Two cylinders rotating next to each other generate a large hydrodynamic force if the intermediate space is filled with a viscous fluid. Herein, we explore the case where the cylinders are separated by two layers of viscous immiscible fluids, in the limit of small capillary deformation of the fluid interface. As the interface deformation breaks the system's symmetry, a novel force characteristic of…
▽ More
Two cylinders rotating next to each other generate a large hydrodynamic force if the intermediate space is filled with a viscous fluid. Herein, we explore the case where the cylinders are separated by two layers of viscous immiscible fluids, in the limit of small capillary deformation of the fluid interface. As the interface deformation breaks the system's symmetry, a novel force characteristic of soft lubrication is generated. We calculate this capillary-lubrication force, which is split into velocity-dependant and acceleration-dependant contributions. Furthermore, we analyze the variations induced by modifying the viscosity ratio between the two fluid layers, their thickness ratio, and the Bond number. Unlike standard elastic cases, where a repelling soft-lubrication lift force has been abundantly reported, the current fluid bilayer setting can also exhibit an attractive force due to the non-monotonic deflection of the fluid interface when varying the sublayer thickness. Besides, at high Bond numbers, the system's response becomes analogous to the one of a Winkler-like substrate with a viscous flow inside.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?
Authors:
Nu Ri Choi,
Md Ashequr Rahman,
Zitong Yu,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Myocardial perfusion imaging using single-photon emission computed tomography (SPECT), or myocardial perfusion SPECT (MPS) is a widely used clinical imaging modality for the diagnosis of coronary artery disease. Current clinical protocols for acquiring and reconstructing MPS images are similar for most patients. However, for patients with outlier anatomical characteristics, such as large breasts,…
▽ More
Myocardial perfusion imaging using single-photon emission computed tomography (SPECT), or myocardial perfusion SPECT (MPS) is a widely used clinical imaging modality for the diagnosis of coronary artery disease. Current clinical protocols for acquiring and reconstructing MPS images are similar for most patients. However, for patients with outlier anatomical characteristics, such as large breasts, images acquired using conventional protocols are often sub-optimal in quality, leading to degraded diagnostic accuracy. Solutions to improve image quality for these patients outside of increased dose or total acquisition time remain challenging. Thus, there is an important need for new methodologies to improve image quality for such patients. One approach to improving this performance is adapting the image acquisition protocol specific to each patient. For this study, we first designed and implemented a personalized patient-specific protocol-optimization strategy, which we term precision SPECT (PRESPECT). This strategy integrates ideal observer theory with the constraints of tomographic reconstruction to optimize the acquisition time for each projection view, such that MPS defect detection performance is maximized. We performed a clinically realistic simulation study on patients with outlier anatomies on the task of detecting perfusion defects on various realizations of low-dose scans by an anthropomorphic channelized Hotelling observer. Our results show that using PRESPECT led to improved performance on the defect detection task for the considered patients. These results provide evidence that personalization of MPS acquisition protocol has the potential to improve defect detection performance, motivating further research to design optimal patient-specific acquisition and reconstruction protocols for MPS, as well as developing similar approaches for other medical imaging modalities.
△ Less
Submitted 26 March, 2024;
originally announced March 2024.
-
WIN-PDQ: A Wiener-estimator-based projection-domain quantitative SPECT method that accounts for intra-regional uptake heterogeneity
Authors:
Zekun Li,
Nadia Benabdallah,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantificati…
▽ More
SPECT can enable the quantification of activity uptake in lesions and at-risk organs in α-particle-emitting radiopharmaceutical therapies (α-RPTs). But this quantification is challenged by the low photon counts, complicated isotope physics, and the image-degrading effects in α-RPT SPECT. Thus, strategies to optimize the SPECT system and protocol designs for the task of regional uptake quantification are needed. Objectively performing this task-based optimization requires a reliable (accurate and precise) regional uptake quantification method. Conventional reconstruction-based quantification (RBQ) methods have been observed to be erroneous for α-RPT SPECT. Projection-domain quantification methods, which estimate regional uptake directly from SPECT projections, have demonstrated potential in providing reliable regional uptake estimates, but these methods assume constant uptake within the regions, an assumption that may not hold. To address these challenges, we propose WIN-PDQ, a Wiener-estimator-based projection-domain quantitative SPECT method. The method accounts for the heterogeneity within the regions of interest while estimating mean uptake. An early-stage evaluation of the method was conducted using 3D Monte Carlo-simulated SPECT of anthropomorphic phantoms with radium-223 uptake and lumpy-model-based intra-regional uptake heterogeneity. In this evaluation with phantoms of varying mean regional uptake and intra-regional uptake heterogeneity, the WIN-PDQ method yielded ensemble unbiased estimates and significantly outperformed both reconstruction-based and previously proposed projection-domain quantification methods. In conclusion, based on these preliminary findings, the proposed method is showing potential for estimating mean regional uptake in α-RPTs and towards enabling the objective task-based optimization of SPECT system and protocol designs.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
How accurately can quantitative imaging methods be ranked without ground truth: An upper bound on no-gold-standard evaluation
Authors:
Yan Liu,
Abhinav K. Jha
Abstract:
Objective evaluation of quantitative imaging (QI) methods with patient data, while important, is typically hindered by the lack of gold standards. To address this challenge, no-gold-standard evaluation (NGSE) techniques have been proposed. These techniques have demonstrated efficacy in accurately ranking QI methods without access to gold standards. The development of NGSE methods has raised an imp…
▽ More
Objective evaluation of quantitative imaging (QI) methods with patient data, while important, is typically hindered by the lack of gold standards. To address this challenge, no-gold-standard evaluation (NGSE) techniques have been proposed. These techniques have demonstrated efficacy in accurately ranking QI methods without access to gold standards. The development of NGSE methods has raised an important question: how accurately can QI methods be ranked without ground truth. To answer this question, we propose a Cramer-Rao bound (CRB)-based framework that quantifies the upper bound in ranking QI methods without any ground truth. We present the application of this framework in guiding the use of a well-known NGSE technique, namely the regression-without-truth (RWT) technique. Our results show the utility of this framework in quantifying the performance of this NGSE technique for different patient numbers. These results provide motivation towards studying other applications of this upper bound.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Eight-shot measurement of spatially non-stationary complex coherence function
Authors:
Pranay Mohta,
Abhinandan Bhattacharjee,
Anand K. Jha
Abstract:
Spatial coherence plays an important role in several real-world applications ranging from imaging to communication. As a result, its accurate characterization and measurement are extremely crucial for its optimal application. However, efficient measurement of an arbitrary complex spatial coherence function is still very challenging. In this letter, we propose an efficient, noise-insensitive interf…
▽ More
Spatial coherence plays an important role in several real-world applications ranging from imaging to communication. As a result, its accurate characterization and measurement are extremely crucial for its optimal application. However, efficient measurement of an arbitrary complex spatial coherence function is still very challenging. In this letter, we propose an efficient, noise-insensitive interferometric technique that combines wavefront shearing and inversion for measuring the complex cross-spectral density function of the class of fields, in which the cross-spectral density function depends either on the difference of the spatial coordinates, or the squares of spatial coordinates, or both. This class of fields are most commonly encountered, and we experimentally demonstrate high-fidelity measurement of many stationary and non-stationary fields.
△ Less
Submitted 29 February, 2024;
originally announced March 2024.
-
Observer study-based evaluation of TGAN architecture used to generate oncological PET images
Authors:
Roberto Fedrigo,
Fereshteh Yousefirizi,
Ziping Liu,
Abhinav K. Jha,
Robert V. Bergen,
Jean-Francois Rajotte,
Raymond T. Ng,
Ingrid Bloise,
Sara Harsini,
Dan J. Kadrmas,
Carlos Uribe,
Arman Rahmim
Abstract:
The application of computer-vision algorithms in medical imaging has increased rapidly in recent years. However, algorithm training is challenging due to limited sample sizes, lack of labeled samples, as well as privacy concerns regarding data sharing. To address these issues, we previously developed (Bergen et al. 2022) a synthetic PET dataset for Head and Neck (H and N) cancer using the temporal…
▽ More
The application of computer-vision algorithms in medical imaging has increased rapidly in recent years. However, algorithm training is challenging due to limited sample sizes, lack of labeled samples, as well as privacy concerns regarding data sharing. To address these issues, we previously developed (Bergen et al. 2022) a synthetic PET dataset for Head and Neck (H and N) cancer using the temporal generative adversarial network (TGAN) architecture and evaluated its performance segmenting lesions and identifying radiomics features in synthesized images. In this work, a two-alternative forced-choice (2AFC) observer study was performed to quantitatively evaluate the ability of human observers to distinguish between real and synthesized oncological PET images. In the study eight trained readers, including two board-certified nuclear medicine physicians, read 170 real/synthetic image pairs presented as 2D-transaxial using a dedicated web app. For each image pair, the observer was asked to identify the real image and input their confidence level with a 5-point Likert scale. P-values were computed using the binomial test and Wilcoxon signed-rank test. A heat map was used to compare the response accuracy distribution for the signed-rank test. Response accuracy for all observers ranged from 36.2% [27.9-44.4] to 63.1% [54.8-71.3]. Six out of eight observers did not identify the real image with statistical significance, indicating that the synthetic dataset was reasonably representative of oncological PET images. Overall, this study adds validity to the realism of our simulated H&N cancer dataset, which may be implemented in the future to train AI algorithms while favoring patient confidentiality and privacy protection.
△ Less
Submitted 27 November, 2023; v1 submitted 27 November, 2023;
originally announced November 2023.
-
Interface stabilization in adhesion caused by elastohydrodynamic deformation
Authors:
Preetika Karnal,
Yumo Wang,
Anushka Jha,
Stefan Gryska,
Carlos Barrios,
Joelle Frechette
Abstract:
Interfacial instabilities are common phenomena observed during adhesion measurements involving viscoelastic polymers or fluids. Typical probe-tack adhesion measurements with soft adhesives are conducted with rigid probes. However, in many settings, such as for medical applications, adhesives make and break contact from soft surfaces such as skin. Here we study how detachment from soft probes alter…
▽ More
Interfacial instabilities are common phenomena observed during adhesion measurements involving viscoelastic polymers or fluids. Typical probe-tack adhesion measurements with soft adhesives are conducted with rigid probes. However, in many settings, such as for medical applications, adhesives make and break contact from soft surfaces such as skin. Here we study how detachment from soft probes alters the debonding mechanism of a model viscoelastic polymer film. We demonstrate that detachment from a soft probe suppresses Saffman-Taylor instabilities commonly encountered in adhesion. We suggest the mechanism for interface stabilization is elastohydrodynamic deformation of the probe and propose a scaling for the onset of stabilization.
△ Less
Submitted 18 September, 2023;
originally announced September 2023.
-
Unraveling Quantum Coherences Mediating Primary Charge Transfer Processes in Photosystem II Reaction Center
Authors:
Ajay Jha,
Pan-Pan Zhang,
Vandana Tiwari,
Lipeng Chen,
Michael Thorwart,
R. J. Dwayne Miller,
Hong-Guang Duan
Abstract:
Photosystem II (PSII) reaction center is a unique protein-chromophore complex that is capable of efficiently separating electronic charges across the membrane after photoexcitation. In the PSII reaction center, the primary energy- and charge-transfer (CT) processes occur on comparable ultrafast timescales, which makes it extremely challenging to understand the fundamental mechanism responsible for…
▽ More
Photosystem II (PSII) reaction center is a unique protein-chromophore complex that is capable of efficiently separating electronic charges across the membrane after photoexcitation. In the PSII reaction center, the primary energy- and charge-transfer (CT) processes occur on comparable ultrafast timescales, which makes it extremely challenging to understand the fundamental mechanism responsible for the near-unity quantum efficiency of the transfer. Here, we elucidate the role of quantum coherences in the ultrafast energy and CT in the PSII reaction center by performing two-dimensional (2D) electronic spectroscopy at the cryogenic temperature of 20 K, which captures the distinct underlying quantum coherences. Specifically, we uncover the electronic and vibrational coherences along with their lifetimes during the primary ultrafast processes of energy and CT. We also examine the functional role of the observed quantum coherences. To gather further insight, we construct a structure-based excitonic model that provided evidence for coherent energy and CT at low temperature in the 2D electronic spectra. The principles, uncovered by this combination of experimental and theoretical analyses, could provide valuable guidelines for creating artificial photosystems with exploitation of system-bath coupling and control of coherences to optimize the photon conversion efficiency to specific functions.
△ Less
Submitted 24 July, 2023;
originally announced July 2023.
-
Capillary-lubrication force exerted on a 2D particle moving towards a fluid interface
Authors:
Aditya Jha,
Yacine Amarouchene,
Thomas Salez
Abstract:
A rigid object moving in a viscous fluid and in close proximity with an elastic wall experiences self-generated elastohydrodynamic interactions. This has been the subject of an intense research activity, with a recent and growing attention given to the particular case of elastomeric and gel-like substrates. Here, we address the situation where the elastic wall is replaced by a capillary surface. S…
▽ More
A rigid object moving in a viscous fluid and in close proximity with an elastic wall experiences self-generated elastohydrodynamic interactions. This has been the subject of an intense research activity, with a recent and growing attention given to the particular case of elastomeric and gel-like substrates. Here, we address the situation where the elastic wall is replaced by a capillary surface. Specifically, we analyze the lubrication flow generated by the prescribed normal motion of a rigid infinite cylinder near the deformable interface separating two immiscible and incompressible viscous fluids. Using a combination of analytical and numerical treatments, we compute the emergent capillary-lubrication force at leading order in compliance, and characterize its dependencies with the interfacial tension, viscosities of the fluids, and length scales of the problem. Interestingly, we identify two main contributions: i) a velocity-dependent adhesion-like force ; ii) an acceleration-dependant inertial-like force. Our results may have implications for the mobility of colloids near complex interfaces and for the motility of confined microbiological entities.
△ Less
Submitted 22 June, 2023;
originally announced July 2023.
-
Evaluation and Mitigation of Traffic Related Concerns in Kathmandu Valley
Authors:
Aadarsha Bhusal,
Ankit Jha,
Anish Khanal,
Aayush Awasthi,
Aman Kumar Mahato
Abstract:
Motor cars are more prevalent on the highways of major cities like Kathmandu as a result of the raging increase in urban population. As a result, the residents of this city are accustomed to experiencing frequent traffic jams. The fact that every person is forced to spend an average of 120 hours a year doing nothing productive due to traffic congestion makes this very clear. Evidently, identifying…
▽ More
Motor cars are more prevalent on the highways of major cities like Kathmandu as a result of the raging increase in urban population. As a result, the residents of this city are accustomed to experiencing frequent traffic jams. The fact that every person is forced to spend an average of 120 hours a year doing nothing productive due to traffic congestion makes this very clear. Evidently, identifying the problem does not always result in a fix. However, creating intelligent traffic management systems with intelligent traffic signals and early warning systems could be a successful substitute. Furthermore, creative road engineering, as demonstrated by features like road diet and roundabouts, is a popular treatment. However, the primary issue is the preference for private vehicles over public transportation. It can definitely help to reduce these worries to cultivate a society-friendly mentality along with effective, inventive approaches.
△ Less
Submitted 6 June, 2023;
originally announced June 2023.
-
DEMIST: A deep-learning-based task-specific denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Richard Laforest,
Craig K. Abbey,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose…
▽ More
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a Detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5% and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic DL-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
△ Less
Submitted 25 October, 2023; v1 submitted 7 June, 2023;
originally announced June 2023.
-
Joint regional uptake quantification of Thorium-227 and Radium-223 using a multiple-energy-window projection-domain quantitative SPECT method
Authors:
Zekun Li,
Nadia Benabdallah,
Richard Laforest,
Richard L. Wahl,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
Thorium-227-based alpha-particle radiopharmaceutical therapies (α-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting isotope, which redistributes within the patient. Reliable dose quantification of both Thorium-227 and Radium-223 is clinically important, and SPECT may perform this quanti…
▽ More
Thorium-227-based alpha-particle radiopharmaceutical therapies (α-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting isotope, which redistributes within the patient. Reliable dose quantification of both Thorium-227 and Radium-223 is clinically important, and SPECT may perform this quantification as these isotopes also emit X- and gamma-ray photons. However, reliable quantification is challenged by the orders-of-magnitude lower activity compared to conventional SPECT, resulting in a very low number of detected counts, the presence of multiple photopeaks, substantial overlap in the emission spectra of these isotopes, and the image-degrading effects in SPECT. To address these issues, we propose a multiple-energy-window projection-domain quantification (MEW-PDQ) method that jointly estimates the regional activity uptake of both Thorium-227 and Radium-223 directly using the SPECT projection from multiple energy windows. We evaluated the method with realistic simulation studies using anthropomorphic digital phantoms, in the context of imaging patients with bone metastases of prostate cancer and treated with Thorium-227-based α-RPTs. The proposed method yielded reliable (accurate and precise) regional uptake estimates of both isotopes and outperformed state-of-the-art methods across different lesion sizes and contrasts, in a virtual imaging trial, as well as with moderate levels of intra-regional heterogeneous uptake and with moderate inaccuracies in the definitions of the support of various regions. Additionally, we demonstrated the effectiveness of using multiple energy windows and the variance of the estimated uptake using the proposed method approached the Cramér-Rao-lower-bound-defined theoretical limit.
△ Less
Submitted 1 July, 2024; v1 submitted 26 May, 2023;
originally announced May 2023.
-
A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks
Authors:
Md Ashequr Rahman,
Zekun Li,
Zitong Yu,
Richard Laforest,
Daniel L. J. Thorek,
Abhinav K. Jha
Abstract:
SPECT provides a mechanism to perform absorbed-dose quantification tasks for $α$-particle radiopharmaceutical therapies ($α$-RPTs). However, quantitative SPECT for $α$-RPT is challenging due to the low number of detected counts, the complex emission spectrum, and other image-degrading artifacts. Towards addressing these challenges, we propose a low-count quantitative SPECT reconstruction method fo…
▽ More
SPECT provides a mechanism to perform absorbed-dose quantification tasks for $α$-particle radiopharmaceutical therapies ($α$-RPTs). However, quantitative SPECT for $α$-RPT is challenging due to the low number of detected counts, the complex emission spectrum, and other image-degrading artifacts. Towards addressing these challenges, we propose a low-count quantitative SPECT reconstruction method for isotopes with multiple emission peaks.
Given the low-count setting, it is important that the reconstruction method extract the maximal possible information from each detected photon. Processing data over multiple energy windows and in list-mode (LM) format provide mechanisms to achieve that objective. Towards this goal, we propose a list-mode multi-energy window (LM-MEW) OSEM-based SPECT reconstruction method that uses data from multiple energy windows in LM format, and includes the energy attribute of each detected photon. For computational efficiency, we developed a multi-GPU-based implementation of this method. The method was evaluated using 2-D SPECT simulation studies in a single-scatter setting conducted in the context of imaging [$^{223}$Ra]RaCl${_2}$.
The proposed method yielded improved performance on the task of estimating activity uptake within known regions of interest in comparison to approaches that use a single energy window or use binned data. The improved performance was observed in terms of both accuracy and precision and for different sizes of the region of interest.
Results of our studies show that the use of multiple energy windows and processing data in LM format with the proposed LM-MEW method led to improved quantification performance in low-count SPECT of isotopes with multiple emission peaks. These results motivate further development and validation of the LM-MEW method for such imaging applications, including for $α$-RPT SPECT.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
A quality assurance framework for real-time monitoring of deep learning segmentation models in radiotherapy
Authors:
Xiyao Jin,
Yao Hao,
Jessica Hilliard,
Zhehao Zhang,
Maria A. Thomas,
Hua Li,
Abhinav K. Jha,
Geoffrey D. Hugo
Abstract:
To safely deploy deep learning models in the clinic, a quality assurance framework is needed for routine or continuous monitoring of input-domain shift and the models' performance without ground truth contours. In this work, cardiac substructure segmentation was used as an example task to establish a QA framework. A benchmark dataset consisting of Computed Tomography (CT) images along with manual…
▽ More
To safely deploy deep learning models in the clinic, a quality assurance framework is needed for routine or continuous monitoring of input-domain shift and the models' performance without ground truth contours. In this work, cardiac substructure segmentation was used as an example task to establish a QA framework. A benchmark dataset consisting of Computed Tomography (CT) images along with manual cardiac delineations of 241 patients were collected, including one 'common' image domain and five 'uncommon' domains. Segmentation models were tested on the benchmark dataset for an initial evaluation of model capacity and limitations. An image domain shift detector was developed by utilizing a trained Denoising autoencoder (DAE) and two hand-engineered features. Another Variational Autoencoder (VAE) was also trained to estimate the shape quality of the auto-segmentation results. Using the extracted features from the image/segmentation pair as inputs, a regression model was trained to predict the per-patient segmentation accuracy, measured by Dice coefficient similarity (DSC). The framework was tested across 19 segmentation models to evaluate the generalizability of the entire framework.
As results, the predicted DSC of regression models achieved a mean absolute error (MAE) ranging from 0.036 to 0.046 with an averaged MAE of 0.041. When tested on the benchmark dataset, the performances of all segmentation models were not significantly affected by scanning parameters: FOV, slice thickness and reconstructions kernels. For input images with Poisson noise, CNN-based segmentation models demonstrated a decreased DSC ranging from 0.07 to 0.41, while the transformer-based model was not significantly affected.
△ Less
Submitted 19 May, 2023;
originally announced May 2023.
-
Need for Objective Task-based Evaluation of Deep Learning-Based Denoising Methods: A Study in the Context of Myocardial Perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Richard Laforest,
Thomas H. Schindler,
Robert J. Gropler,
Richard L. Wahl,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images…
▽ More
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images have typically been evaluated using fidelity-based figures of merit (FoMs) such as RMSE and SSIM. However, these images are acquired for clinical tasks and thus should be evaluated based on their performance in these tasks. Our objectives were to (1) investigate whether evaluation with these FoMs is consistent with objective clinical-task-based evaluation; (2) provide a theoretical analysis for determining the impact of denoising on signal-detection tasks; (3) demonstrate the utility of virtual clinical trials (VCTs) to evaluate DL-based methods. A VCT to evaluate a DL-based method for denoising myocardial perfusion SPECT (MPS) images was conducted. The impact of DL-based denoising was evaluated using fidelity-based FoMs and AUC, which quantified performance on detecting perfusion defects in MPS images as obtained using a model observer with anthropomorphic channels. Based on fidelity-based FoMs, denoising using the considered DL-based method led to significantly superior performance. However, based on ROC analysis, denoising did not improve, and in fact, often degraded detection-task performance. The results motivate the need for objective task-based evaluation of DL-based denoising approaches. Further, this study shows how VCTs provide a mechanism to conduct such evaluations using VCTs. Finally, our theoretical treatment reveals insights into the reasons for the limited performance of the denoising approach.
△ Less
Submitted 1 April, 2023; v1 submitted 3 March, 2023;
originally announced March 2023.
-
Need for objective task-based evaluation of AI-based segmentation methods for quantitative PET
Authors:
Ziping Liu,
Joyce C. Mhlanga,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Artificial intelligence (AI)-based methods are showing substantial promise in segmenting oncologic positron emission tomography (PET) images. For clinical translation of these methods, assessing their performance on clinically relevant tasks is important. However, these methods are typically evaluated using metrics that may not correlate with the task performance. One such widely used metric is th…
▽ More
Artificial intelligence (AI)-based methods are showing substantial promise in segmenting oncologic positron emission tomography (PET) images. For clinical translation of these methods, assessing their performance on clinically relevant tasks is important. However, these methods are typically evaluated using metrics that may not correlate with the task performance. One such widely used metric is the Dice score, a figure of merit that measures the spatial overlap between the estimated segmentation and a reference standard (e.g., manual segmentation). In this work, we investigated whether evaluating AI-based segmentation methods using Dice scores yields a similar interpretation as evaluation on the clinical tasks of quantifying metabolic tumor volume (MTV) and total lesion glycolysis (TLG) of primary tumor from PET images of patients with non-small cell lung cancer. The investigation was conducted via a retrospective analysis with the ECOG-ACRIN 6668/RTOG 0235 multi-center clinical trial data. Specifically, we evaluated different structures of a commonly used AI-based segmentation method using both Dice scores and the accuracy in quantifying MTV/TLG. Our results show that evaluation using Dice scores can lead to findings that are inconsistent with evaluation using the task-based figure of merit. Thus, our study motivates the need for objective task-based evaluation of AI-based segmentation methods for quantitative PET.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
A task-specific deep-learning-based denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, st…
▽ More
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, studies have shown that these methods may have limited impact on the performance of clinical tasks in SPECT. To address this issue, we use concepts from the literature on model observers and our understanding of the human visual system to propose a DL-based denoising approach designed to preserve observer-related information for detection tasks. The proposed method was objectively evaluated on the task of detecting perfusion defect in myocardial perfusion SPECT images using a retrospective study with anonymized clinical data. Our results demonstrate that the proposed method yields improved performance on this detection task compared to using low-dose images. The results show that by preserving task-specific information, DL may provide a mechanism to improve observer performance in low-dose myocardial perfusion SPECT.
△ Less
Submitted 28 February, 2023;
originally announced March 2023.
-
Development and task-based evaluation of a scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Craig K. Abbey,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosi…
▽ More
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.
△ Less
Submitted 18 March, 2023; v1 submitted 28 February, 2023;
originally announced March 2023.
-
CoRuVSi: A potential candidate for spin semimetal with promising spintronic and thermoelectric properties
Authors:
Jadupati Nag,
R. Venkatesh,
Ajay Jha,
Plamen Stamenov,
P. D. Babu,
Aftab Alam,
K. G. Suresh
Abstract:
Based on our experimental and theoretical studies, we report the identification of the quaternary Heusler alloy, CoRuVSi as a new member of the recently discovered spin semimetals class. Spin polarised semimetals possess a unique band structure in which one of the spin bands shows semimetallic nature, while the other shows semiconducting/insulating nature. Our findings show that CoRuVSi possesses…
▽ More
Based on our experimental and theoretical studies, we report the identification of the quaternary Heusler alloy, CoRuVSi as a new member of the recently discovered spin semimetals class. Spin polarised semimetals possess a unique band structure in which one of the spin bands shows semimetallic nature, while the other shows semiconducting/insulating nature. Our findings show that CoRuVSi possesses interesting spintronic and thermoelectric properties. Magnetization data reveal a weak ferri-/antiferro magnetic ordering at low temperatures, with only a very small moment $\sim$ 0.13 $μ_B$/f.u., attributed to the disorder. Transport results provide strong evidence of semimetallicity dominated by two-band conduction, while magnetoresistance data show a non-saturating, linear, positive, magnetoresistance. Spin polarization measurements using point-contact Andreev reflection spectra reveal a reasonably high spin polarization of $\sim$ 50\%, which matches fairly well with the simulated result. Furthermore, CoRuVSi shows a high thermopower value of $0.7$ $m Watt/ m-K^{2}$ at room temperature with the dominant contribution from the semimetallic bands, rendering it as a promising thermoelectric material as well. Our ab-initio simulation not only confirms a unique semimetallic feature, but also reveals that the band structure hosts a linear band crossing at $\sim$ -0.4 eV below the Fermi level incorporated by a band-inversion. In addition, the observed topological non-trivial features of the band structure is corroborated with the simulated Berry curvature, intrinsic anomalous Hall conductivity and the Fermi surface. The coexistence of many interesting properties relevant for spintronic, topological and thermoelectric applications in a single material is extremely rare and hence this study could promote a similar strategy to identify other potential materials belonging to same class.
△ Less
Submitted 14 January, 2023;
originally announced January 2023.
-
Issues and Challenges in Applications of Artificial Intelligence to Nuclear Medicine -- The Bethesda Report (AI Summit 2022)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Irène Buvat,
Joyita Dutta,
Abhinav K. Jha,
Paul E. Kinahan,
Quanzheng Li,
Chi Liu,
Melissa D. McCradden,
Babak Saboury,
Eliot Siegel,
John J. Sunderland,
Richard L. Wahl
Abstract:
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of…
▽ More
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of AI in nuclear medicine. In what follows, essential issues, challenges, controversies and findings emphasized in the meeting are summarized.
△ Less
Submitted 7 November, 2022;
originally announced November 2022.
-
Adhesion of fluid infused silicone elastomer to glass
Authors:
Anushka Jha,
Preetika Karnal,
Joelle Frechette
Abstract:
Elastomers swollen with non-polar fluids show potential as anti-adhesive materials. We study the effect of oil fraction and contact time on the adhesion between swollen spherical probes of PDMS (polydimethylsiloxane) and flat glass surfaces. The PDMS probes are swollen with pre-determined amount of 10 cSt silicone oil to span the range where the PDMS is fluid free (via solvent extraction) up to th…
▽ More
Elastomers swollen with non-polar fluids show potential as anti-adhesive materials. We study the effect of oil fraction and contact time on the adhesion between swollen spherical probes of PDMS (polydimethylsiloxane) and flat glass surfaces. The PDMS probes are swollen with pre-determined amount of 10 cSt silicone oil to span the range where the PDMS is fluid free (via solvent extraction) up to the limit where it is oil saturated. Probe tack measurements show that adhesion decreases rapidly with an increase in oil fraction. The decrease in adhesion is attributed to excess oil present at the PDMS-air interface. Contact angle measurements and optical microscopy images support this observation. Adhesion also increases with contact time for a given oil fraction. The increase in adhesion with contact time can be interpreted through different competing mechanisms that depend on the oil fraction where the dominant mechanism changes from extracted to fully swollen PDMS. For partially swollen PDMS, we observe that adhesion initially increases because of viscoelastic relaxation and at long times increases because of contact aging. In contrast, adhesion between fully swollen PDMS and glass barely increases over time and is mainly due to capillary forces. While the relaxation of PDMS in contact is well-described by a visco-poroelastic model, we do not see evidence that poroelastic relaxation of the PDMS contributes to an increase of adhesion with glass whether it is partially or fully swollen.
△ Less
Submitted 4 November, 2022;
originally announced November 2022.
-
Quantifying polarization changes induced by rotating Dove prisms and K-mirrors
Authors:
Suman Karan,
Ruchi,
Pranay Mohta,
Anand K. Jha
Abstract:
Dove prisms and K-mirrors are devices extensively used for rotating the wavefront of an optical field. These devices have several applications, including measurement of orbital angular momentum, microscopy, beam steering and pattern recognition. However, the wavefront rotation achieved through these devices is always accompanied by polarization changes in the incident field, which is an undesirabl…
▽ More
Dove prisms and K-mirrors are devices extensively used for rotating the wavefront of an optical field. These devices have several applications, including measurement of orbital angular momentum, microscopy, beam steering and pattern recognition. However, the wavefront rotation achieved through these devices is always accompanied by polarization changes in the incident field, which is an undesirable feature in many of these applications. Although the polarization changes induced by a Dove prism have been explored to quite some extent, no such study is available for a K-mirror. In this letter, we theoretically and experimentally investigate polarization changes induced in the transmitted field by a rotating K-mirror. For quantifying such polarization changes, we define a quantity, mean polarization change D, which ranges from 0 to π. We find that K-mirrors can reduce D to about 0.03π, for any incident state of polarization; however, reducing D to the same extent with a Dove prism is practically unviable. Therefore, K-mirrors are better alternatives to Dove prisms in applications in which the polarization changes accompanying wavefront rotation need to be minimum.
△ Less
Submitted 1 August, 2022;
originally announced August 2022.
-
Broadband physical layer cognitive radio with an integrated photonic processor for blind source separation
Authors:
Weipeng Zhang,
Alexander Tait,
Chaoran Huang,
Thomas Ferreira de Lima,
Simon Bilodeau,
Eric Blow,
Aashu Jha,
Bhavin J. Shastri,
Paul Prucnal
Abstract:
The expansion of telecommunications incurs increasingly severe crosstalk and interference, and a physical layer cognitive method, called blind source separation (BSS), can effectively address these issues. BSS requires minimal prior knowledge to recover signals from their mixtures, agnostic to carrier frequency, signal format, and channel conditions. However, previous electronic implementations of…
▽ More
The expansion of telecommunications incurs increasingly severe crosstalk and interference, and a physical layer cognitive method, called blind source separation (BSS), can effectively address these issues. BSS requires minimal prior knowledge to recover signals from their mixtures, agnostic to carrier frequency, signal format, and channel conditions. However, previous electronic implementations of BSS did not fulfill this versatility requirement due to the inherently narrow bandwidth of radio-frequency (RF) components, the high energy consumption of digital signal processors (DSP), and their shared weaknesses of low scalability. Here, we report a photonic BSS approach that inherits the advantages of optical devices and can fully fulfill its "blindness" aspect. Using a microring weight bank integrated on a photonic chip, we demonstrate energy-efficient, WDM-scalable BSS across 19.2 GHz of bandwidth, covering many standard frequency bands. Our system also has a high (9-bit) resolution for signal demixing thanks to a recently developed dithering control method, resulting in higher signal-to-interference ratios (SIR) even for ill-conditioned mixtures.
△ Less
Submitted 8 June, 2022; v1 submitted 6 May, 2022;
originally announced May 2022.
-
Postselection-free controlled generation of a high-dimensional orbital-angular-momentum entangled state
Authors:
Suman Karan,
Radhika Prasad,
Anand K. Jha
Abstract:
High-dimensional entangled states in orbital angular momentum (OAM) basis offer several unique advantages for quantum information applications. However, for the optimal performance of a given application, one requires a generation technique for OAM entangled states that is completely postselection-free and fully controllable. Nonetheless, despite several efforts in the past, no such technique curr…
▽ More
High-dimensional entangled states in orbital angular momentum (OAM) basis offer several unique advantages for quantum information applications. However, for the optimal performance of a given application, one requires a generation technique for OAM entangled states that is completely postselection-free and fully controllable. Nonetheless, despite several efforts in the past, no such technique currently exists. In this article, we propose just such a technique and experimentally demonstrate postselection-free generation of up to about 150-dimensional OAM entangled states. We report the generation accuracy, which is a measure of the control, to be more than 98% for states with Gaussian and triangular OAM Schmidt spectra and up to 90% for the maximally-entangled OAM states, which have rectangular spectra.
△ Less
Submitted 25 October, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Ideal-observer computation with anthropomorphic phantoms using Markov Chain Monte Carlo
Authors:
Md Ashequr Rahman,
Zitong Yu,
Abhinav K. Jha
Abstract:
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-comput…
▽ More
In medical imaging, it is widely recognized that image quality should be objectively evaluated based on performance in clinical tasks. To evaluate performance in signal-detection tasks, the ideal observer (IO) is optimal but also challenging to compute in clinically realistic settings. Markov Chain Monte Carlo (MCMC)-based strategies have demonstrated the ability to compute the IO using pre-computed projections of an anatomical database. To evaluate image quality in clinically realistic scenarios, the observer performance should be measured for realistic patient distribution. This implies that the anatomical database should also be derived from a realistic population. In this manuscript, we propose to advance the MCMC-based approach to achieve these goals. We then use the proposed approach to study the effect of anatomical database size on IO computation for the task of detecting perfusion defects in simulated myocardial perfusion SPECT images. Our preliminary results provide evidence that the size of the anatomical database affects the computation of IO.
△ Less
Submitted 7 March, 2022;
originally announced March 2022.
-
No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noise
Authors:
Ziping Liu,
Zekun Li,
Joyce C. Mhlanga,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and…
▽ More
Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and Gaussian-distributed noise term, where the noise between measurements made by different methods is independent of each other. However, this noise arises in the process of measuring the same quantitative value, and thus can be correlated. To address this limitation, we propose a no-gold-standard evaluation (NGSE) technique that models this correlated noise by a multi-variate Gaussian distribution parameterized by a covariance matrix. We derive a maximum-likelihood-based approach to estimate the parameters that describe the relationship between the true and measured values, without any knowledge of the true values. We then use the estimated slopes and diagonal elements of the covariance matrix to compute the noise-to-slope ratio (NSR) to rank the QI methods on the basis of precision. The proposed NGSE technique was evaluated with multiple numerical experiments. Our results showed that the technique reliably estimated the NSR values and yielded accurate rankings of the considered methods for ~ 83% of 160 trials. In particular, the technique correctly identified the most precise method for ~ 97% of the trials. Overall, this study demonstrates the efficacy of the NGSE technique to accurately rank different QI methods when the correlated noise is present, and without access to any knowledge of the ground truth. The results motivate further validation of this technique with realistic simulation studies and patient data.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterization
Authors:
Zitong Yu,
Md Ashequr Rahman,
Abhinav K. Jha
Abstract:
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this st…
▽ More
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this study in the context of evaluating a DL-based approach for denoising SPECT images. The training data consisted of signals of different sizes and shapes within a clustered-lumpy background, imaged with a 2D parallel-hole-collimator SPECT system. The projections were generated at normal and 20% low count level, both of which were reconstructed using an OSEM algorithm. A CNN-based denoiser was trained to process the low-count images. The performance of this CNN was characterized for five different signal sizes and four different SBR by designing each evaluation as an SKE/BKS signal-detection task. Performance on this task was evaluated using an anthropomorphic CHO. As in previous studies, we observed that the DL-based denoising method did not improve performance on signal-detection tasks. Evaluation using the idea of observer-study-based characterization demonstrated that the DL-based denoising approach did not improve performance on the signal-detection task for any of the signal types. Overall, these results provide new insights on the performance of the DL-based denoising approach as a function of signal size and contrast. More generally, the observer study-based characterization provides a mechanism to evaluate the sensitivity of the method to specific object properties and may be explored as analogous to characterizations such as modulation transfer function for linear systems. Finally, this work underscores the need for objective task-based evaluation of DL-based denoising approaches.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Design Automation of Photonic Resonator Weights
Authors:
Thomas Ferreira de Lima,
Eli A. Doris,
Simon Bilodeau,
Weipeng Zhang,
Aashu Jha,
Hsuan-Tung Peng,
Eric C. Blow,
Chaoran Huang,
Alexander N. Tait,
Bhavin J. Shastri,
Paul R. Prucnal
Abstract:
Neuromorphic photonic processors based on resonator weight banks are an emerging candidate technology for enabling modern artificial intelligence (AI) in high speed, analog systems. These purpose-built analog devices implement vector multiplications with the physics of resonator devices, offering efficiency, latency, and throughput advantages over equivalent electronic circuits. Along with these a…
▽ More
Neuromorphic photonic processors based on resonator weight banks are an emerging candidate technology for enabling modern artificial intelligence (AI) in high speed, analog systems. These purpose-built analog devices implement vector multiplications with the physics of resonator devices, offering efficiency, latency, and throughput advantages over equivalent electronic circuits. Along with these advantages, however, often comes the difficult challenges of compensation for fabrication variations and environmental disturbances. In this paper we review sources of variation and disturbances from our experiments, as well as mathematically define quantities that model them. Then, we introduce how the physics of resonators can be exploited to weight and sum multiwavelength signals. Finally, we outline automated design and control methodologies necessary to create practical, manufacturable, and high accuracy/precision resonator weight banks that can withstand operating conditions in the field. This represents a road map for unlocking the potential of resonator weight banks in practical deployment scenarios.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Nanophotonic cavity based synapse for scalable photonic neural networks
Authors:
Aashu Jha,
Chaoran Huang,
Thomas Ferriera deLima,
Hsuan-Tung Peng,
Bhavin Shastri,
Paul R. Prucnal
Abstract:
The bandwidth and energy demands of neural networks has spurred tremendous interest in developing novel neuromorphic hardware, including photonic integrated circuits. Although an optical waveguide can accommodate hundreds of channels with THz bandwidth, the channel count of photonic systems is always bottlenecked by the devices within. In WDM-based photonic neural networks, the synapses, i.e. netw…
▽ More
The bandwidth and energy demands of neural networks has spurred tremendous interest in developing novel neuromorphic hardware, including photonic integrated circuits. Although an optical waveguide can accommodate hundreds of channels with THz bandwidth, the channel count of photonic systems is always bottlenecked by the devices within. In WDM-based photonic neural networks, the synapses, i.e. network interconnections, are typically realized by microring resonators (MRRs), where the WDM channel count (N) is bounded by the free-spectral range of the MRRs. For typical Si MRRs, we estimate N <= 30 within the C-band. This not only restrains the aggregate throughput of the neural network but also makes applications with high input dimensions unfeasible. We experimentally demonstrate that photonic crystal nanobeam based synapses can be FSR-free within C-band, eliminating the bound on channel count. This increases data throughput as well as enables applications with high-dimensional inputs like natural language processing and high resolution image processing. In addition, the smaller physical footprint of photonic crystal nanobeam cavities offers higher tuning energy efficiency and a higher compute density than MRRs. Nanophotonic cavity based synapse thus offers a path towards realizing highly scalable photonic neural networks.
△ Less
Submitted 28 February, 2022;
originally announced March 2022.
-
Demonstration of magnetic and light-controlled actuation of a photomagnetically actuated deformable mirror for wavefront control
Authors:
Amit Kumar Jha,
Ewan S. Douglas,
Meng Li,
Corey Fucetola,
Fiorenzo G. Omenetto
Abstract:
Deformable Mirrors (DMs) have wide applications ranging from astronomical imaging to laser communications and vision science. However, they often require bulky multi-channel cables for delivering high power to their drive actuators. A low powered DM which is driven in a contactless fashion could provide a possible alternative to this problem.Here, we present a photo-magnetically actuated deformabl…
▽ More
Deformable Mirrors (DMs) have wide applications ranging from astronomical imaging to laser communications and vision science. However, they often require bulky multi-channel cables for delivering high power to their drive actuators. A low powered DM which is driven in a contactless fashion could provide a possible alternative to this problem.Here, we present a photo-magnetically actuated deformable mirror (PMADM) concept which is actuated in a contactless fashion by a permanent magnet and low power laser heating source. This paper presents the laboratory demonstration of prototype optical surface quality, magnetic control of focus, and COMSOL simulations of its precise photo-control. The PMADM prototype is made of a magnetic composite (polydimethylsiloxane [PDMS] + ferromagnetic $\text{CrO}_\text{2}$) and an optical-quality substrate layer and is 30.48 mm $\times$ 30.48 mm $\times$ 175 $μ$ m in dimension with an optical pupil diameter of 8 mm. It deforms to 5.76 $μ$ m when subjected to a 0.12 T magnetic flux density and relaxes to 3.76 $μ$ m when illuminated by a 50 mW laser. A maximum stroke of 8.78 $μ$ m before failure is also estimated considering a 3x safety factor. This works also includes simulation of astigmatism generation with the PMADM, a first step in demonstrating control of higher order modes. A fully developed PMADM can have potential application for wavefront corrections in vacuum and space environments.
△ Less
Submitted 23 December, 2021;
originally announced December 2021.
-
Propagation-induced entanglement revival
Authors:
Abhinandan Bhattacharjee,
Mritunjay K. Joshi,
Suman Karan,
Jonathan Leach,
Anand K. Jha
Abstract:
The practical implementation of free-space quantum information tasks requires entanglement to be sustained over long distances and in the presence of turbulent and noisy environments. The transverse position-momentum entanglement of photon pairs produced by parametric down-conversion has found several uses in quantum information science, however, it is not suitable for applications involving long-…
▽ More
The practical implementation of free-space quantum information tasks requires entanglement to be sustained over long distances and in the presence of turbulent and noisy environments. The transverse position-momentum entanglement of photon pairs produced by parametric down-conversion has found several uses in quantum information science, however, it is not suitable for applications involving long-distance propagation as the entanglement decays very rapidly when photons propagate away from their source. Entanglement is lost after a few centimetres of propagation, and the effect becomes even more pronounced in turbulent environments. In contrast, in this article, we show that entanglement in the angle-orbital angular momentum (OAM) bases exhibits a remarkably different behaviour. As with the position-momentum case, initially, the angle-OAM entanglement decays with propagation, but as the photons continue to travel further from the source, the photons regain their strongly correlated behaviour, and the entanglement returns. We theoretically and experimentally demonstrate this behaviour and show that entanglement returns even in the presence of strong turbulence. The only effect of turbulence is to increase the propagation distance for revival, but once revived, the two photons remain entangled up to an arbitrary propagation distance. This work highlights the role that OAM-angle entanglement will play in applications where quantum information is shared over long distances.
△ Less
Submitted 8 November, 2021;
originally announced November 2021.
-
Silicon photonic-electronic neural network for fibre nonlinearity compensation
Authors:
Chaoran Huang,
Shinsuke Fujisawa,
Thomas Ferreira de Lima,
Alexander N. Tait,
Eric C. Blow,
Yue Tian,
Simon Bilodeau,
Aashu Jha,
F atih Yaman,
Hsuan-Tung Peng,
Hussam G. Batshon,
Bhavin J. Shastri,
Yoshihisa Inada,
Ting Wang,
Paul R. Prucnal
Abstract:
In optical communication systems, fibre nonlinearity is the major obstacle in increasing the transmission capacity. Typically, digital signal processing techniques and hardware are used to deal with optical communication signals, but increasing speed and computational complexity create challenges for such approaches. Highly parallel, ultrafast neural networks using photonic devices have the potent…
▽ More
In optical communication systems, fibre nonlinearity is the major obstacle in increasing the transmission capacity. Typically, digital signal processing techniques and hardware are used to deal with optical communication signals, but increasing speed and computational complexity create challenges for such approaches. Highly parallel, ultrafast neural networks using photonic devices have the potential to ease the requirements placed on the digital signal processing circuits by processing the optical signals in the analogue domain. Here we report a silicon photonice-lectronic neural network for solving fibre nonlinearity compensation of submarine optical fibre transmission systems. Our approach uses a photonic neural network based on wavelength-division multiplexing built on a CMOS-compatible silicon photonic platform. We show that the platform can be used to compensate optical fibre nonlinearities and improve the signal quality (Q)-factor in a 10,080 km submarine fibre communication system. The Q-factor improvement is comparable to that of a software-based neural network implemented on a 32-bit graphic processing unit-assisted workstation. Our reconfigurable photonic-electronic integrated neural network promises to address pressing challenges in high-speed intelligent signal processing.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.
-
Photonic spiking neural networks and CMOS-compatible graphene-on-silicon spiking neurons
Authors:
Aashu Jha,
Chaoran Huang,
Hsuan-Tung Peng,
Bhavin Shastri,
Paul R. Prucnal
Abstract:
Spiking neural networks are known to be superior over artificial neural networks for their computational power efficiency and noise robustness. The benefits of spiking coupled with the high-bandwidth and low-latency of photonics can enable highly-efficient, noise-robust, high-speed neural processors. The landscape of photonic spiking neurons consists of an overwhelming majority of excitable lasers…
▽ More
Spiking neural networks are known to be superior over artificial neural networks for their computational power efficiency and noise robustness. The benefits of spiking coupled with the high-bandwidth and low-latency of photonics can enable highly-efficient, noise-robust, high-speed neural processors. The landscape of photonic spiking neurons consists of an overwhelming majority of excitable lasers and a few demonstrations on nonlinear optical cavities. The silicon platform is best poised to host a scalable photonic technology given its CMOS-compatibility and low optical loss. Here, we present a survey of existing photonic spiking neurons, and propose a novel spiking neuron based on a hybrid graphene-on-silicon microring cavity. A comparison among a representative sample of photonic spiking devices is also presented. Finally, we discuss methods employed in training spiking neural networks, their challenges as well as the application domain that can be enabled by photonic spiking neural hardware.
△ Less
Submitted 28 September, 2021;
originally announced September 2021.