Tilt angle measurement with a Gaussian-shaped laser beam tracking
Authors:
Martin Šarbort,
Šimon Řeřucha,
Petr Jedlička,
Josef Lazar,
Ondrej Číp
Abstract:
We have addressed the challenge to carry out the angular tilt stabilization of a laser guiding mirror which is intended to route a laser beam with a high energy density. Such an application requires good angular accuracy as well as large operating range, long term stability and absolute positioning. We have designed an instrument for such a high precision angular tilt measurement based on a triang…
▽ More
We have addressed the challenge to carry out the angular tilt stabilization of a laser guiding mirror which is intended to route a laser beam with a high energy density. Such an application requires good angular accuracy as well as large operating range, long term stability and absolute positioning. We have designed an instrument for such a high precision angular tilt measurement based on a triangulation method where a laser beam with Gaussian profile is reflected off the stabilized mirror and detected by an image sensor. As the angular deflection of the mirror causes a change of the beam spot position, the principal task is to measure the position on the image chip surface. We have employed a numerical analysis of the Gaussian intensity pattern which uses the nonlinear regression algorithm. The feasibility and performance of the method were tested by numeric modeling as well as experimentally. The experimental results indicate that the assembled instrument achieves a measurement error of 0.13 microradian in the range +-0.65 degrees over the period of one hour. This corresponds to the dynamic range of 1:170 000.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Automatic unit for measuring refractive index of air based on Ciddor equation and its verification using direct interferometric measurement method
Authors:
V. Hucl,
M. Cizek,
J. Hrabina,
B. Mikel,
S. Rerucha,
Z. Buchta,
P. Jedlicka,
A. Lesundak,
J. Oulehla,
L. Mrna,
M. Sarbort,
R. Smid,
J. Lazar,
O. Cip
Abstract:
In scanning probe microscopy laser interferometers are usually used for measuring the position of the probe tip with a metrological traceability. As the most of the AFM setups are designed to work under standard atmospheric conditions the changes of the refractive index of air have an influence to measured values of the length with 1.0e-4 relatively. In order to achieve better accuracies the refra…
▽ More
In scanning probe microscopy laser interferometers are usually used for measuring the position of the probe tip with a metrological traceability. As the most of the AFM setups are designed to work under standard atmospheric conditions the changes of the refractive index of air have an influence to measured values of the length with 1.0e-4 relatively. In order to achieve better accuracies the refractive index of air has to be monitored continuously and its instantaneous value has to be used for compensating the lengths measured by all of the interferometric axes. In the presented work we developed a new concept of an electronic unit which is able to monitor the refractive index of air on basis of measurement of ambient atmospheric conditions: temperature, humidity, pressure of the air and the CO2 concentration. The data processing is based on Ciddor equation for calculating the refractive index of air. The important advantage of the unit is a very low power consumption of the electronics so the unit causes only negligible temperature effects to the measured environment. The accuracy of the indirect measuring method employed by the unit was verified. We tested the accuracy in comparison with a direct method of measuring refractive index of air based on an evacuatable cell placed at the measuring arm of a laser interferometer. An experimental setup used for verification is presented together with a set of measurements describing the performance. The resulting accuracy of the electronic unit falls to the 4.1e-7 relatively.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Investigating the use of the hydrogen cyanide (HCN) as an absorption media for laser spectroscopy
Authors:
Martin Hosek,
Simon Rerucha,
Lenka Pravdova,
Martin Cizek,
Jan Hrabina,
Petr Jedlicka,
Ondrej Cip
Abstract:
The laser spectroscopy is a fundamental approach for the realisation of traceable optical frequency standards. In the $1.55\,μ$m wavelength band, widely used in telecommunications, the acetylene is the typical and the most widespread absorption media. We present our investigation of using the hydrogen cyanide (HCN) as a cost-efficient and readily available alternative, that also provides a wider f…
▽ More
The laser spectroscopy is a fundamental approach for the realisation of traceable optical frequency standards. In the $1.55\,μ$m wavelength band, widely used in telecommunications, the acetylene is the typical and the most widespread absorption media. We present our investigation of using the hydrogen cyanide (HCN) as a cost-efficient and readily available alternative, that also provides a wider frequency span (from $1527\,$nm to $1563\,$nm). We have compared the practical aspects of using new absorption media in comparison to existing experience with the acetylene with an outlook to carry out an independent measurement of the entire spectra. The results should contribute to the future inclusion of the HCN spectroscopic data into the Mise en pratique, thus allowing for the use of HCN as a reference for the realisation of traceable laser standards.
△ Less
Submitted 17 May, 2019;
originally announced May 2019.
-
Linearized and Compensated Interferometric System for High-Velocity Traceable Length Calibration on a Metre Scale
Authors:
Simon Rerucha,
Bretislav Mikel,
Zdenek Matej,
Ondrej Herman,
Miroslava Hola,
Michal Jelinek,
Petr Jedlicka,
Ondrej Cip,
Josef Lazar
Abstract:
We report on a traceable calibration system for a 3500mm-long console that carries a measurement system for inspecting the diameter of a circular reactor chassis. The system uses two single-pass laser interferometers with homodyne fringe detection for measurement in two degrees of freedom. The hybrid FPGA-microcontroller control module carries out the fringe detection together with the application…
▽ More
We report on a traceable calibration system for a 3500mm-long console that carries a measurement system for inspecting the diameter of a circular reactor chassis. The system uses two single-pass laser interferometers with homodyne fringe detection for measurement in two degrees of freedom. The hybrid FPGA-microcontroller control module carries out the fringe detection together with the application-specific scale linearization approach and the compensation of environmental influences such as thermal elongation and the refractive index of air fluctuations. We demonstrated the system feasibility with an accuracy of a few microns and translation velocity higher than 0:1 metre per second.
△ Less
Submitted 2 May, 2019;
originally announced May 2019.