Design and Construction of the MicroBooNE Detector
Authors:
MicroBooNE Collaboration,
R. Acciarri,
C. Adams,
R. An,
A. Aparicio,
S. Aponte,
J. Asaadi,
M. Auger,
N. Ayoub,
L. Bagby,
B. Baller,
R. Barger,
G. Barr,
M. Bass,
F. Bay,
K. Biery,
M. Bishai,
A. Blake,
V. Bocean,
D. Boehnlein,
V. D. Bogert,
T. Bolton,
L. Bugel,
C. Callahan,
L. Camilleri
, et al. (215 additional authors not shown)
Abstract:
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, a…
▽ More
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
△ Less
Submitted 17 January, 2017; v1 submitted 17 December, 2016;
originally announced December 2016.
-
Electron drift in a large scale solid xenon
Authors:
J. Yoo,
W. F. Jaskierny
Abstract:
A study of charge drift in a large scale optically transparent solid xenon is reported. A pulsed high power xenon light source is used to liberate electrons from a photocathode. The drift speeds of the electrons are measured using a 8.7\,cm long electrode in both the liquid and solid phase of xenon. In the liquid phase (163\,K), the drift speed is 0.193 $\pm$ 0.003 cm/$μ$s while the drift speed in…
▽ More
A study of charge drift in a large scale optically transparent solid xenon is reported. A pulsed high power xenon light source is used to liberate electrons from a photocathode. The drift speeds of the electrons are measured using a 8.7\,cm long electrode in both the liquid and solid phase of xenon. In the liquid phase (163\,K), the drift speed is 0.193 $\pm$ 0.003 cm/$μ$s while the drift speed in the solid phase (157\,K) is 0.397 $\pm$ 0.006 cm/$μ$s at 900 V/cm over 8.0\,cm of uniform electric fields. Therefore, it is demonstrated that a factor two faster electron drift speed in solid phase xenon compared to that in liquid in a large scale solid xenon.
△ Less
Submitted 24 August, 2015;
originally announced August 2015.
-
Scalability study of solid xenon
Authors:
J. Yoo,
H. Cease,
W. F. Jaskierny,
D. Markley,
R. B. Pahlka,
D. Balakishiyeva,
T. Saab,
M. Filipenko
Abstract:
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employed a cryostat cooled by liquid nitrogen combined with a xenon purification and chiller system. A modified {\it Bridgeman's technique} reproduces a large scale optically transparent solid xenon.
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employed a cryostat cooled by liquid nitrogen combined with a xenon purification and chiller system. A modified {\it Bridgeman's technique} reproduces a large scale optically transparent solid xenon.
△ Less
Submitted 24 August, 2015;
originally announced August 2015.
-
Design and operation of LongBo: a 2 m long drift liquid argon TPC
Authors:
C. Bromberg,
B. Carls,
D. Edmunds,
A. Hahn,
W. Jaskierny,
H. Jostlein,
C. Kendziora,
S. Lockwitz,
B. Pahlka,
S. Pordes,
B. Rebel,
D. Shooltz,
M. Stancari,
T. Tope,
T. Yang
Abstract:
In this paper, we report on the design and operation of the LongBo time projection chamber in the Liquid Argon Purity Demonstrator cryostat. This chamber features a 2 m long drift distance. We measure the electron drift lifetime in the liquid argon using cosmic ray muons and the lifetime is at least 14 ms at 95\% confidence level. LongBo is equipped with preamplifiers mounted on the detector in th…
▽ More
In this paper, we report on the design and operation of the LongBo time projection chamber in the Liquid Argon Purity Demonstrator cryostat. This chamber features a 2 m long drift distance. We measure the electron drift lifetime in the liquid argon using cosmic ray muons and the lifetime is at least 14 ms at 95\% confidence level. LongBo is equipped with preamplifiers mounted on the detector in the liquid argon. Of the 144 channels, 128 channels were readout by preamplifiers made with discrete circuitry and 16 channels were readout by ASIC preamplifiers. For the discrete channels, we measure a signal-to-noise (S/N) ratio of 30 at a drift field of 350 V/cm. The measured S/N ratio for the ASIC channels was 1.4 times larger than that measured for the discrete channels.
△ Less
Submitted 12 May, 2015; v1 submitted 1 April, 2015;
originally announced April 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Scalability, scintillation readout and charge drift in a kilogram scale solid xenon particle detector
Authors:
J. Yoo,
H. Cease,
W. F. Jaskierny,
D. Markley,
R. B. Pahlka,
D. Balakishiyeva,
T. Saab,
M. Filipenko
Abstract:
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from seale…
▽ More
We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.
△ Less
Submitted 23 October, 2014;
originally announced October 2014.
-
The Liquid Argon Purity Demonstrator
Authors:
M. Adamowski,
B. Carls,
E. Dvorak,
A. Hahn,
W. Jaskierny,
C. Johnson,
H. Jostlein,
C. Kendziora,
S. Lockwitz,
B. Pahlka,
R. Plunkett,
S. Pordes,
B. Rebel,
R. Schmitt,
M. Stancari,
T. Tope,
E. Voirin,
T. Yang
Abstract:
The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtaine…
▽ More
The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.
△ Less
Submitted 27 March, 2014;
originally announced March 2014.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
A Regenerable Filter for Liquid Argon Purification
Authors:
A. Curioni,
B. T. Fleming,
W. Jaskierny,
C. Kendziora,
J. Krider,
S. Pordes,
M. Soderberg,
J. Spitz,
T. Tope,
T. Wongjirad
Abstract:
A filter system for removing electronegative impurities from liquid argon is described. The active components of the filter are adsorbing molecular sieve and activated-copper-coated alumina granules. The system is capable of purifying liquid argon to an oxygen-equivalent impurity concentration of better than 30 parts per trillion, corresponding to an electron drift lifetime of at least 10 ms. Re…
▽ More
A filter system for removing electronegative impurities from liquid argon is described. The active components of the filter are adsorbing molecular sieve and activated-copper-coated alumina granules. The system is capable of purifying liquid argon to an oxygen-equivalent impurity concentration of better than 30 parts per trillion, corresponding to an electron drift lifetime of at least 10 ms. Reduction reactions that occur at about 250 degrees Celsius allow the filter material to be regenerated in-situ through a simple procedure. In the following work we describe the filter design, performance, and regeneration process.
△ Less
Submitted 11 March, 2009;
originally announced March 2009.