-
Development of a linac-based LEPD experimental station for surface structure analysis and coordination with synchrotron radiation ARPES
Authors:
Rezwan Ahmed,
Izumi Mochizuki,
Toshio Hyodo,
Tetsuroh Shirasawa,
Seigi Mizuno,
Yoshinari Kondo,
Kenichi Ozawa,
Miho Kitamura,
Kenta Amemiya,
Bartlomiej Checinski,
Jozef Ociepa,
Achim Czasch,
Ottmar Jagutzki,
Ken Wada
Abstract:
We report on the development of a low-energy positron diffraction (LEPD) experimental station for surface structure analysis using a linac-based slow-positron beam. LEPD, the positron counterpart of low-energy electron diffraction (LEED), offers higher accuracy in surface structure determination. The station enables acquisition of LEPD I-V curves within a few hours, allowing measurements before su…
▽ More
We report on the development of a low-energy positron diffraction (LEPD) experimental station for surface structure analysis using a linac-based slow-positron beam. LEPD, the positron counterpart of low-energy electron diffraction (LEED), offers higher accuracy in surface structure determination. The station enables acquisition of LEPD I-V curves within a few hours, allowing measurements before surface degradation occurs. It consists of two ultra-high vacuum (UHV) chambers: one for sample preparation and the other for LEPD observations. The preparation chamber includes an Ar+ sputtering system, a triple-pocket electron beam evaporator, three gas introduction systems, additional user-configurable ports, and a LEED/Auger electron spectroscopy (AES) system. Sample manipulators enable rapid cooling, precise positioning, and orientation adjustments. In the preparation chamber, the manipulator also supports direct current heating up to 1200 °C. The sample holder is compatible with the LEPD station at SPF-A4 and the ARPES station at PF BL-13B, both located at the Tsukuba campus of the Institute of Materials Structure Science (IMSS), KEK. Design concepts and experimental demonstrations are presented.
△ Less
Submitted 3 January, 2025; v1 submitted 30 December, 2024;
originally announced January 2025.
-
Absolute ion detection efficiencies of microchannel plates and funnel microchannel plates for multi-coincidence detection
Authors:
K. Fehre,
D. Trojanowskaja,
J. Gatzke,
M. Kunitski,
F. Trinter,
S. Zeller,
L. Ph. H. Schmidt,
J. Stohner,
R. Berger,
A. Czasch,
O. Jagutzki,
T. Jahnke,
R. Dörner,
M. S. Schöffler
Abstract:
Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency e is as high as possible, as the overall efficiency scales with e over n, i.e. the power of the number of detected particles. Here we present measured abs…
▽ More
Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency e is as high as possible, as the overall efficiency scales with e over n, i.e. the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced "funnel MCPs". Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The "funnel" MCPs exhibit an efficiency of approx. 90 percent, gaining a factor of 24 (as compared to "normal" MCPs) in case of a five-fold ion coincidence detection.
△ Less
Submitted 22 March, 2018;
originally announced March 2018.
-
Search for isotope effects in projectile and target ionization in swift He$^+$ on H$_2$ or D$_2$ collisions
Authors:
F. Trinter,
M. Waitz,
M. S. Schöffler,
H. -K. Kim,
J. Titze,
O. Jagutzki,
A. Czasch,
L. Ph. H. Schmidt,
H. Schmidt-Böcking,
R. Dörner
Abstract:
Using the cold target recoil ion momentum spectroscopy (COLTRIMS) technique, we have measured the simultaneous projectile and target ionization in collisions of He$^+$ projectiles with a mixture of gaseous H$_2$ and D$_2$ for an incident projectile energy of 650 keV. Motivated by Cooper et al. [Phys. Rev. Lett. 100, 043204 (2008)], we look for differences in the ionization cross section of the two…
▽ More
Using the cold target recoil ion momentum spectroscopy (COLTRIMS) technique, we have measured the simultaneous projectile and target ionization in collisions of He$^+$ projectiles with a mixture of gaseous H$_2$ and D$_2$ for an incident projectile energy of 650 keV. Motivated by Cooper et al. [Phys. Rev. Lett. 100, 043204 (2008)], we look for differences in the ionization cross section of the two isotopes with the highest resolution and statistical significance. Contributions of the electron-electron and electron-nucleus interactions have been clearly separated kinematically by measuring the longitudinal and transverse momentum of the recoiling ion. We find no significant isotope effect in any of our momentum distributions.
△ Less
Submitted 6 March, 2014; v1 submitted 12 November, 2013;
originally announced November 2013.
-
Ion impact induced Interatomic Coulombic Decay in neon and argon dimers
Authors:
H. -K. Kim,
H. Gassert,
M. S. Schöffler,
J. N. Titze,
M. Waitz,
J. Voigtsberger,
F. Trinter,
J. Becht,
A. Kalinin,
N. Neumann,
C. Zhou,
L. Ph. H. Schmidt,
O. Jagutzki,
A. Czasch,
H. Merabet,
H. Schmidt-Böcking,
T. Jahnke,
A. Cassimi,
R. Dörner
Abstract:
We investigate the contribution of Interatomic Coulombic Decay induced by ion impact in neon and argon dimers (Ne$_2$ and Ar$_2$) to the production of low energy electrons. Our experiments cover a broad range of perturbation strengths and reaction channels. We use 11.37 MeV/u S$^{14+}$, 0.125 MeV/u He$^{1+}$, 0.1625 MeV/u He$^{1+}$ and 0.150 MeV/u He$^{2+}$ as projectiles and study ionization, sin…
▽ More
We investigate the contribution of Interatomic Coulombic Decay induced by ion impact in neon and argon dimers (Ne$_2$ and Ar$_2$) to the production of low energy electrons. Our experiments cover a broad range of perturbation strengths and reaction channels. We use 11.37 MeV/u S$^{14+}$, 0.125 MeV/u He$^{1+}$, 0.1625 MeV/u He$^{1+}$ and 0.150 MeV/u He$^{2+}$ as projectiles and study ionization, single and double electron transfer to the projectile as well as projectile electron loss processes. The application of a COLTRIMS reaction microscope enables us to retrieve the three-dimensional momentum vectors of the ion pairs of the fragmenting dimer into Ne$^{q+}$/Ne$^{1+}$ and Ar$^{q+}$/Ar$^{1+}$ (q = 1, 2, 3) in coincidence with at least one emitted electron.
△ Less
Submitted 31 October, 2013;
originally announced October 2013.
-
Transfer ionization and its sensitivity to the ground-state wave function
Authors:
M. S. Schöffler,
O. Chuluunbaatar,
Yu. V. Popov,
S. Houamer,
J. Titze,
T. Jahnke,
L. Ph. H. Schmidt,
O. Jagutzki,
A. G. Galstyan,
A. A. Gusev
Abstract:
We present kinematically complete theoretical calculations and experiments for transfer ionization in H$^++$He collisions at 630 keV/u. Experiment and theory are compared on the most detailed level of fully differential cross sections in the momentum space. This allows us to unambiguously identify contributions from the shake-off and two-step-2 mechanisms of the reaction. It is shown that the simu…
▽ More
We present kinematically complete theoretical calculations and experiments for transfer ionization in H$^++$He collisions at 630 keV/u. Experiment and theory are compared on the most detailed level of fully differential cross sections in the momentum space. This allows us to unambiguously identify contributions from the shake-off and two-step-2 mechanisms of the reaction. It is shown that the simultaneous electron transfer and ionization is highly sensitive to the quality of a trial initial-state wave function.
△ Less
Submitted 22 February, 2013; v1 submitted 6 August, 2012;
originally announced August 2012.
-
Time and position sensitive single photon detector for scintillator read-out
Authors:
Sven Schössler,
Benjamin Bromberger,
Michal Brandis,
Lothar Ph. H. Schmidt,
Kai Tittelmeier,
Achim Czasch,
Volker Dangendorf,
Ottmar Jagutzki
Abstract:
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode plac…
▽ More
We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy gamma radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate gamma energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).
△ Less
Submitted 10 February, 2012; v1 submitted 12 January, 2012;
originally announced January 2012.
-
Carbon K-shell Photo Ionization of CO: Molecular frame angular Distributions of normal and conjugate shakeup Satellites
Authors:
T. Jahnke,
J. Titze,
L. Foucar,
R. Wallauer,
T. Osipov,
E. P. Benis,
O. Jagutzki,
W. Arnold,
A. Czasch,
A. Staudte,
M. Schöffler,
A. Alnaser,
T. Weber,
M. H. Prior,
H. Schmidt-Böcking,
R. Dörner
Abstract:
We have measured the molecular frame angular distributions of photoelectrons emitted from the Carbon K shell of fixed-in-space CO molecules for the case of simultaneous excitation of the remaining molecular ion. Normal and conjugate shake up states are observed. Photo electrons belonging to normal Σ-satellite lines show an angular distribution resembling that observed for the main photoline at the…
▽ More
We have measured the molecular frame angular distributions of photoelectrons emitted from the Carbon K shell of fixed-in-space CO molecules for the case of simultaneous excitation of the remaining molecular ion. Normal and conjugate shake up states are observed. Photo electrons belonging to normal Σ-satellite lines show an angular distribution resembling that observed for the main photoline at the same electron energy. Surprisingly a similar shape is found for conjugate shake up states with Π-symmetry. In our data we identify shake rather than electron scattering (PEVE) as the mechanism producing the conjugate lines. The angular distributions clearly show the presence of a Σ-shape resonance for all of the satellite lines.
△ Less
Submitted 28 March, 2011;
originally announced March 2011.
-
Auger decay of 1σg and 1σu hole states of N2 molecule: disentangling decay routes from coincidence measurements
Authors:
S. K. Semenov,
M. S. Schöffler,
J. Titze,
N. Petridis,
T. Jahnke,
K. Cole,
L. Ph. H. Schmidt,
A. Czasch,
D. Akoury,
O. Jagutzki,
J. B. Williams,
T. Osipov,
S. Lee,
M. H. Prior,
A. Belkacem,
A. L. Landers,
H. Schmidt-Böcking,
Th. Weber,
N. A. Cherepkov,
R. Dörner
Abstract:
Results of the most sophisticated measurements in coincidence of the angular resolved K-shell photo- and Auger-electrons, and of two atomic ions produced by dissociation of N2 molecule, are analyzed. Detection of photoelectrons at certain angles allows separating the Auger decay processes of the 1σg and 1σu core hole states. The Auger electron angular distributions for each of these hole states ar…
▽ More
Results of the most sophisticated measurements in coincidence of the angular resolved K-shell photo- and Auger-electrons, and of two atomic ions produced by dissociation of N2 molecule, are analyzed. Detection of photoelectrons at certain angles allows separating the Auger decay processes of the 1σg and 1σu core hole states. The Auger electron angular distributions for each of these hole states are measured as a function of the kinetic energy release of two atomic ions and are compared with the corresponding theoretical angular distributions. From that comparison one can disentangle the contributions of different repulsive doubly charged molecular ion states to the Auger decay. Different kinetic energy release values are directly related to the different internuclear distances. In this way one can trace experimentally the behavior of the potential energy curves of dicationic final states inside the Frank-Condon region. Presentation of the Auger electron angular distributions as a function of kinetic energy release of two atomic ions opens a new dimension in the study of Auger decay.
△ Less
Submitted 4 May, 2010;
originally announced May 2010.
-
Fragmentation dynamics of CO23+ investigated by multiple electron capture in collisions with slow highly charged ions
Authors:
N. Neumann,
D. Hant,
L. Ph. H. Schmidt,
J. Titze,
T. Jahnke,
A. Czasch,
M. S. Schöffler,
K. Kreidi,
O. Jagutzki,
H. Schmidt-Böcking,
R. Dörner
Abstract:
Fragmentation of highly charged molecular ions or clusters consisting of more than two atoms can proceed in an onestep synchronous manner where all bonds break simultaneously or sequentially by emitting one ion after the other. We separated these decay channels for the fragmentation of CO23+ ions by measuring the momenta of the ionic fragments. We show that the total energy deposited in the mole…
▽ More
Fragmentation of highly charged molecular ions or clusters consisting of more than two atoms can proceed in an onestep synchronous manner where all bonds break simultaneously or sequentially by emitting one ion after the other. We separated these decay channels for the fragmentation of CO23+ ions by measuring the momenta of the ionic fragments. We show that the total energy deposited in the molecular ion is a control parameter which switches between three distinct fragmentation pathways: the sequential fragmentation in which the emission of an O+ ion leaves a rotating CO2+ ion behind that fragments after a time delay, the Coulomb explosion and an in-between fragmentation - the asynchronous dissociation. These mechanisms are directly distinguishable in Dalitz plots and Newton diagrams of the fragment momenta. The CO23+ ions are produced by multiple electron capture in collisions with 3.2 keV/u Ar8+ ions.
△ Less
Submitted 21 January, 2010;
originally announced January 2010.
-
Localization of Inner-Shell Photoelectron Emission and Interatomic Coulombic Decay in Ne$_2$
Authors:
K. Kreidi,
T. Jahnke,
Th. Weber,
T. Havermeier,
R. E. Grisenti,
X. Liu,
Y. Morisita,
S. Schössler,
L. Ph. H. Schmidt,
M. Schöffler,
M. Odenweller,
N. Neumann,
L. Foucar,
J. Titze,
B. Ulrich,
F. Sturm,
C. Stuck,
R. Wallauer,
S. Voss,
I. Lauter,
H. K. Kim,
M. Rudloff,
H. Fukuzawa,
G. Prümper,
N. Saito
, et al. (7 additional authors not shown)
Abstract:
We used Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) to investigate the decay of Ne$_2$ after K-shell photoionization. The breakup into Ne$^{1+}$ / Ne$^{2+}$ shows interatomic Coulombic decay (ICD) occurring after a preceding atomic Auger decay. The molecular frame angular distributions of the photoelectron and the ICD electron show distinct, asymmetric features, which imply localizat…
▽ More
We used Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) to investigate the decay of Ne$_2$ after K-shell photoionization. The breakup into Ne$^{1+}$ / Ne$^{2+}$ shows interatomic Coulombic decay (ICD) occurring after a preceding atomic Auger decay. The molecular frame angular distributions of the photoelectron and the ICD electron show distinct, asymmetric features, which imply localization of the K-vacancy created at one of the two atomic sites of the Ne$_2$ and an emission of the ICD electron from a localized site. The experimental results are supported by calculations in frozen core Hartree-Fock approach.
△ Less
Submitted 31 March, 2008;
originally announced March 2008.
-
State selective differential cross sections for single and double electron capture in $He\sp{1,2+}-He$ and $p-He$ collisons
Authors:
M. S. Schöffler,
J. Titze,
L. Ph. H. Schmidt,
T. Jahnke,
O. Jagutzki,
H. Schmidt-Böcking,
R. Dörner,
I. Mančev
Abstract:
Using the COLTRIMStechnique, scattering angle differential cross sections for single and double electron capture in collisions of protons and $He\sp{1,2+}$ projectiles with helium atoms for incident energies of $60-630 keV/u$ are measured. We also report new theoretical results obtained by means of four-body one-channel distorted wave models (CDW-BFS, CDW-BIS and BDW), and find mixed agreement w…
▽ More
Using the COLTRIMStechnique, scattering angle differential cross sections for single and double electron capture in collisions of protons and $He\sp{1,2+}$ projectiles with helium atoms for incident energies of $60-630 keV/u$ are measured. We also report new theoretical results obtained by means of four-body one-channel distorted wave models (CDW-BFS, CDW-BIS and BDW), and find mixed agreement with the measured data.
△ Less
Submitted 30 November, 2007;
originally announced November 2007.
-
A position- and time-sensitive photon-counting detector with delay-line read-out
Authors:
O. Jagutzki,
V. Dangendorf,
R. Lauck,
A. Czasch,
J. Milnes
Abstract:
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of…
▽ More
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and Astronomy
△ Less
Submitted 19 March, 2007;
originally announced March 2007.