-
Evaluation of the Response to Electrons and Pions in the Scintillating Fiber and Lead Calorimeter for the Future Electron-Ion Collider
Authors:
Henry Klest,
Maria Żurek,
Tegan D. Beattie,
Manoj Jadhav,
Sylvester Joosten,
Bobae Kim,
Minho Kim,
Jessica Metcalfe,
Zisis Papandreou,
Jared Richards
Abstract:
The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detecto…
▽ More
The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests [NIM A 596 (2008) 327-337 and arXiv:1801.03088] to a higher energy regime.
The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.
△ Less
Submitted 8 June, 2025; v1 submitted 3 April, 2025;
originally announced April 2025.
-
AstroPix: A Pixelated HVCMOS Sensor for Space-Based Gamma-Ray Measurement
Authors:
Amanda L. Steinhebel,
Regina Caputo,
Daniel P. Violette,
Anthony Affolder,
Autumn Bauman,
Carolyn Chinatti,
Aware Deshmukh,
Vitaliy Fadayev,
Yasushi Fukazawa,
Manoj Jadhav,
Carolyn Kierans,
Bobae Kim,
Jihee Kim,
Henry Klest,
Olivia Kroger,
Kavic Kumar,
Shin Kushima,
Jean-Marie Lauenstein,
Richard Leys,
Forest Martinez-Mckinney,
Jessica Metcalfe,
Zachary Metzler,
John W. Mitchell,
Norito Nakano,
Jennifer Ott
, et al. (11 additional authors not shown)
Abstract:
A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring lo…
▽ More
A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25-700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 um. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 +\- 3.2 % at 59.5 keV and 94 +\- 6 um depletion in a low-resistivity test silicon substrate.
△ Less
Submitted 20 January, 2025;
originally announced January 2025.
-
Performance evaluation of the high-voltage CMOS active pixel sensor AstroPix for gamma-ray space telescopes
Authors:
Yusuke Suda,
Regina Caputo,
Amanda L. Steinhebel,
Nicolas Striebig,
Manoj Jadhav,
Yasushi Fukazawa,
Masaki Hashizume,
Carolyn Kierans,
Richard Leys,
Jessica Metcalfe,
Michela Negro,
Ivan Perić,
Jeremy S. Perkins,
Taylor Shin,
Hiroyasu Tajima,
Daniel Violette,
Norito Nakano
Abstract:
AstroPix is a novel monolithic high-voltage CMOS active pixel sensor proposed for next generation medium-energy gamma-ray observatories like the All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X). For AMEGO-X AstroPix must maintain a power consumption of less than $1.5~\rm{mW/{cm}^2}$ while having a pixel pitch of up to $500~\rm{μm}$. We developed the second and third versions of Astro…
▽ More
AstroPix is a novel monolithic high-voltage CMOS active pixel sensor proposed for next generation medium-energy gamma-ray observatories like the All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X). For AMEGO-X AstroPix must maintain a power consumption of less than $1.5~\rm{mW/{cm}^2}$ while having a pixel pitch of up to $500~\rm{μm}$. We developed the second and third versions of AstroPix, namely AstroPix2 and AstroPix3. AstroPix2 and AstroPix3 exhibit power consumptions of $3.4~\rm{mW/{cm}^2}$ and $4.1~\rm{mW/{cm}^2}$, respectively. While AstroPix2 has a pixel pitch of $250~\rm{μm}$, AstroPix3 achieves the desired size for AMEGO-X with a pixel pitch of $500~\rm{μm}$. Performance evaluation of a single pixel in an AstroPix2 chip revealed a dynamic range from 13.9 keV to 59.5 keV, with the energy resolution meeting the AMEGO-X target value ($<10\%$ (FWHM) at 60 keV). We performed energy calibration on most of the pixels in an AstroPix3 chip, yielding a mean energy resolution of 6.2 keV (FWHM) at 59.5 keV, with 44.4% of the pixels satisfying the target value. The dynamic range of AstroPix3 was assessed to span from 22.2 keV to 122.1 keV. The expansion of the depletion layer aligns with expectations in both AstroPix2 and AstroPix3. Furthermore, radiation tolerance testing was conducted on AstroPix. An AstroPix2 chip was subjected to an equivalent exposure of approximately 10 Gy from a high-intensity $\rm{^{60}Co}$ source. The chip was fully operational after irradiation although a decrease in gain by approximately 4% was observed.
△ Less
Submitted 23 August, 2024;
originally announced August 2024.
-
Characterizing Novel Indium Phosphide Pad Detectors with Focused X-ray Beams and Laboratory Tests
Authors:
Earl Almazan,
Anthony Affolder,
Ian Dyckes,
Vitaliy Fadeyev,
Michael Hance,
Manoj Jadhav,
Sungjoon Kim,
Thomas McCoy,
Jessica Metcalfe,
Jason Nielsen,
Jennifer Ott,
Luise Poley,
Taylor Shin,
Dennis Sperlich,
Anirudha V. Sumant
Abstract:
Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indiu…
▽ More
Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. The results show a high degree of performance uniformity in our evaluations, both within a device and between the 48 tested devices. This motivates further studies into thin film devices for future tracking detectors.
△ Less
Submitted 10 September, 2024; v1 submitted 29 May, 2024;
originally announced May 2024.
-
Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam
Authors:
Sungjoon Kim,
Manoj B. Jadhav,
Vikas Berry,
Jessica E. Metcalfe,
Anirudha V. Sumant
Abstract:
Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide dete…
▽ More
Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-insulator-metal (MIM) structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.
△ Less
Submitted 18 April, 2024;
originally announced April 2024.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Monolithic Active Pixel Sensors on CMOS technologies
Authors:
Nicole Apadula,
Whitney Armstrong,
James Brau,
Martin Breidenbach,
R. Caputo,
Gabriella Carinii,
Alberto Collu,
Marcel Demarteau,
Grzegorz Deptuch,
Angelo Dragone,
Gabriele Giacomini,
Carl Grace,
Norman Graf,
Leo Greiner,
Ryan Herbst,
Gunther Haller,
Manoj Jadhav,
Sylvester Joosten,
Christopher J. Kenney,
C. Kierans,
Jihee Kim,
Thomas Markiewicz,
Yuan Mei,
Jessica Metcalfe,
Zein-Eddine Meziani
, et al. (15 additional authors not shown)
Abstract:
Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic Active Pixel Sensors (MAPS), in which Si diodes and readout circuitry are combined in the same pixels, and can be fabricated in some of standard CMOS processes, are…
▽ More
Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic Active Pixel Sensors (MAPS), in which Si diodes and readout circuitry are combined in the same pixels, and can be fabricated in some of standard CMOS processes, are a promising technology for high-granularity and light detectors. In this paper we review 1) the requirements on MAPS for trackers and electromagnetic calorimeters (ECal) at future colliders experiments, 2) the ongoing efforts towards dedicated MAPS for the Electron-Ion Collider (EIC) at BNL, for which the EIC Silicon Consortium was already instantiated, and 3) space-born applications for MeV $γ$-ray experiments with MAPS based trackers (AstroPix).
△ Less
Submitted 28 March, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
LGAD Detector Concept for TOPSiDE Project
Authors:
Kyung-Wook,
Shin,
Jose O. Repond,
David Blyth,
Jessica E. Metcalfe,
Manoj Jadhav,
Abraham Saiden,
Hartmut Sadrozinski
Abstract:
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of time-of-flight measurement for the TOPSiDE project. To achieve the required timing resolution of 10 ps, the LGAD will be completely monolithic structure, eliminating the par…
▽ More
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of time-of-flight measurement for the TOPSiDE project. To achieve the required timing resolution of 10 ps, the LGAD will be completely monolithic structure, eliminating the parasitic elements from hybridization. The detector itself will be consist of the LGAD sensor, amplification and discrimination, and time-over-threshold logic components. At this stage, we are optimizing the LGAD sensor design and preparing a discrete component based readout circuitry. In this work, we will present simulation result of a conceptual LGAD silicon detector and constant-fraction discriminator (CFD) circuit implementation. The timing resolution of the conceptual detector was simulated with EDA tools such as Silvaco Atlas and LTSpice with conjunction of a Monte-Carlo simulator to resolve Landau distribution into the circuit readout simulation. The best timing resolution we achieved was 23 ps.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept
Authors:
M. Jadhav,
W. Armstrong,
I. Cloet,
S. Joosten,
S. M. Mazza,
J. Metcalfe,
Z. -E. Meziani,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden
Abstract:
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the…
▽ More
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with a precision of 14.3 ps (uncertainty 1.5 ps).
△ Less
Submitted 19 February, 2021; v1 submitted 6 October, 2020;
originally announced October 2020.
-
Study of Interplanetary and Geomagnetic Response of Filament Associated CMEs
Authors:
Kunjal Dave,
Wageesh Mishra,
Nandita Srivastava,
R. M. Jadhav
Abstract:
It has been established that Coronal Mass Ejections (CMEs) may have significant impact on terrestrial magnetic field and lead to space weather events. In the present study, we selected several CMEs which are associated with filament eruptions on the Sun. We attempt to identify the presence of filament material within ICME at 1AU. We discuss how different ICMEs associated with filaments lead to mod…
▽ More
It has been established that Coronal Mass Ejections (CMEs) may have significant impact on terrestrial magnetic field and lead to space weather events. In the present study, we selected several CMEs which are associated with filament eruptions on the Sun. We attempt to identify the presence of filament material within ICME at 1AU. We discuss how different ICMEs associated with filaments lead to moderate or major geomagnetic activity on their arrival at the Earth. Our study also highlights the difficulties in identifying the filament material at 1AU within isolated and in interacting CMEs.
△ Less
Submitted 30 June, 2018;
originally announced July 2018.