-
SILVIA: Ultra-precision formation flying demonstration for space-based interferometry
Authors:
Takahiro Ito,
Kiwamu Izumi,
Isao Kawano,
Ikkoh Funaki,
Shuichi Sato,
Tomotada Akutsu,
Kentaro Komori,
Mitsuru Musha,
Yuta Michimura,
Satoshi Satoh,
Takuya Iwaki,
Kentaro Yokota,
Kenta Goto,
Katsumi Furukawa,
Taro Matsuo,
Toshihiro Tsuzuki,
Katsuhiko Yamada,
Takahiro Sasaki,
Taisei Nishishita,
Yuki Matsumoto,
Chikako Hirose,
Wataru Torii,
Satoshi Ikari,
Koji Nagano,
Masaki Ando
, et al. (4 additional authors not shown)
Abstract:
We propose SILVIA (Space Interferometer Laboratory Voyaging towards Innovative Applications), a mission concept designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve sub-micrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust and low-noise micro-propulsion for real-t…
▽ More
We propose SILVIA (Space Interferometer Laboratory Voyaging towards Innovative Applications), a mission concept designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve sub-micrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust and low-noise micro-propulsion for real-time measurement and control of distances and relative orientations between spacecraft. A 100-meter-scale mission in a near-circular low Earth orbit has been identified as an ideal, cost-effective setting for demonstrating SILVIA, as this configuration maintains a good balance between small relative perturbations and low risk for collision. This mission will fill the current technology gap towards future missions, including gravitational wave observatories such as DECIGO (DECihertz Interferometer Gravitational wave Observatory), designed to detect the primordial gravitational wave background, and high-contrast nulling infrared interferometers like LIFE (Large Interferometer for Exoplanets), designed for direct imaging of thermal emissions from nearby terrestrial planet candidates. The mission concept and its key technologies are outlined, paving the way for the next generation of high-precision space-based observatories.
△ Less
Submitted 7 April, 2025;
originally announced April 2025.
-
Initial acquisition requirements for optical cavities in the space gravitational wave antennae DECIGO and B-DECIGO
Authors:
Yuta Michimura,
Koji Nagano,
Kentaro Komori,
Kiwamu Izumi,
Takahiro Ito,
Satoshi Ikari,
Tomotada Akutsu,
Masaki Ando,
Isao Kawano,
Mitsuru Musha,
Shuichi Sato
Abstract:
DECIGO (DECi-hertz Interferometer Gravitational Wave Observatory) is a space-based gravitational wave antenna concept targeting the 0.1-10 Hz band. It consists of three spacecraft arranged in an equilateral triangle with 1,000 km sides, forming Fabry-Pérot cavities between them. A precursor mission, B-DECIGO, is also planned, featuring a smaller 100 km triangle. Operating these cavities requires u…
▽ More
DECIGO (DECi-hertz Interferometer Gravitational Wave Observatory) is a space-based gravitational wave antenna concept targeting the 0.1-10 Hz band. It consists of three spacecraft arranged in an equilateral triangle with 1,000 km sides, forming Fabry-Pérot cavities between them. A precursor mission, B-DECIGO, is also planned, featuring a smaller 100 km triangle. Operating these cavities requires ultra-precise formation flying, where inter-mirror distance and alignment must be precisely controlled. Achieving this necessitates a sequential improvement in precision using various sensors and actuators, from the deployment of the spacecraft to laser link acquisition and ultimately to the control of the Fabry-Pérot cavities to maintain resonance. In this paper, we derive the precision requirements at each stage and discuss the feasibility of achieving them. We show that the relative speed between cavity mirrors must be controlled at the sub-micrometer-per-second level and that relative alignment must be maintained at the sub-microradian level to obtain control signals from the Fabry-Pérot cavities of DECIGO and B-DECIGO.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
Demonstration of tilt sensing using a homodyne quadrature interferometric translational sensor
Authors:
Koji Nagano,
Karera Mori,
Kiwamu Izumi
Abstract:
Future gravitational wave observation in space will demand improvement in the sensitivity of the local sensor for the drag-free control. This paper presents the proposal, design, and demonstration of a new laser interferometric sensor named Quadrature Interferometric Metrology of Translation and Tilt (QUIMETT) for the drag-free local sensor. QUIMETT enables simultaneous measurements of both transl…
▽ More
Future gravitational wave observation in space will demand improvement in the sensitivity of the local sensor for the drag-free control. This paper presents the proposal, design, and demonstration of a new laser interferometric sensor named Quadrature Interferometric Metrology of Translation and Tilt (QUIMETT) for the drag-free local sensor. QUIMETT enables simultaneous measurements of both translational displacement and tilts of a reflective object with a single interferometer package. QUIMETT offers a characteristic feature where the sensitivity to tilt is independent of the interference condition while maintaining the ability to measure the translational displacement for a range greater than the laser wavelength. The tilt-sensing function has been demonstrated in a prototype experiment. The tilt sensitivity remained unchanged in different interference conditions and stayed at 10 nrad/Hz$^{1/2}$ at 0.1 Hz.
△ Less
Submitted 14 May, 2025; v1 submitted 31 October, 2024;
originally announced October 2024.
-
Cross-Correlated Force Measurement for Thermal Noise Reduction in Torsion Pendulum
Authors:
Yusuke Okuma,
Kiwamu Izumi,
Kentaro Komori,
Masaki Ando
Abstract:
The torsion pendulum is a prevailing instrument for measuring small forces acting on a solid body or those between solid bodies. While it offers powerful advantages, the measurement precision suffers from thermal noises of the suspending wires giving rise to stochastic torque noises. This paper proposes a new scheme to reduce the effect of such noise by employing a double torsion pendulum and cros…
▽ More
The torsion pendulum is a prevailing instrument for measuring small forces acting on a solid body or those between solid bodies. While it offers powerful advantages, the measurement precision suffers from thermal noises of the suspending wires giving rise to stochastic torque noises. This paper proposes a new scheme to reduce the effect of such noise by employing a double torsion pendulum and cross-correlation technique based on the theoretical analysis that the thermal torque noise appears at each end of the suspending wire differentially. Cross-correlating two synthesized data streams which are composed of the rotation angles of two torsion stages, it yields the power spectral density estimate of external forces acting on the lower stage with the reduced effect from the thermal torque noises. As an example use case, we discuss the application to the study on the coupling strength of ultra light dark matter to standard model particles. Our evaluation indicates that the upper limit may be improved by an order of magnitude than the previous experiments at 2 mHz, which corresponds to about $8\times10^{-18}$ eV.
△ Less
Submitted 8 April, 2025; v1 submitted 30 March, 2024;
originally announced April 2024.
-
Radiation Tolerance of Low-Noise Photoreceivers for the LISA Space Mission
Authors:
P. Colcombet,
N. Dinu-Jaeger,
C. Inguimbert,
T. Nuns,
S. Bruhier,
N. Christensen,
P. Hofverberg,
N. van Bakel,
M. van Beuzekom,
T. Mistry,
G. Visser,
D. Pascucci,
K. Izumi,
K. Komori,
G. Heinzel,
G. Fernández Barranco,
J. J. M. in t Zand,
P. Laubert,
M. Frericks
Abstract:
This study investigates the effects of space environmental radiation on the performance of InGaAs Quadrant Photodiodes (QPDs) and assesses their suitability for the Laser Interferometer Space Antenna (LISA) mission. QPDs of 1.0, 1.5 and 2.0 mm have been irradiated with 20 and 60 MeV protons, 0.5 and 1 MeV electrons, and Co$^{60}$ gamma. An exposure corresponding to a displacement damage equivalent…
▽ More
This study investigates the effects of space environmental radiation on the performance of InGaAs Quadrant Photodiodes (QPDs) and assesses their suitability for the Laser Interferometer Space Antenna (LISA) mission. QPDs of 1.0, 1.5 and 2.0 mm have been irradiated with 20 and 60 MeV protons, 0.5 and 1 MeV electrons, and Co$^{60}$ gamma. An exposure corresponding to a displacement damage equivalent fluence of $1.0 \times 10^{+12}$ p/cm$^2$ for 20 and 60 MeV protons and a total ionizing dose of 237 krad were applied, surpassing the anticipated radiation levels for the LISA mission by a factor of approximately five. Experiments were conducted to measure changes in QPD dark current, capacitance, and responsivity. The QPDs are integrated with a low-noise DC-coupled transimpedance amplifier to form the Photoreceiver (QPR). QPR noise and performance in an interferometric system like LISA were also measured. Although radiation impacted their dark current and responsivity, almost all QPDs met LISA's validation criteria and did not demonstrate any critical failure. These findings prove that the tested QPDs are promising candidates for LISA and other space-based missions.
△ Less
Submitted 15 October, 2023;
originally announced October 2023.
-
Development of advanced photon calibrator for Kamioka gravitational wave detector (KAGRA)
Authors:
Y. Inoue,
B. H. Hsieh,
K. H. Chen,
Y. K. Chu,
K. Ito,
C. Kozakai,
T. Shishido,
Y. Tomigami,
T. Akutsu,
S. Haino,
K. Izumi,
T. Kajita,
N. Kanda,
C. S. Lin,
F. K. Lin,
Y. Moriwaki,
W. Ogaki,
H. F. Pang,
T. Sawada,
T. Tomaru,
T. Suzuki,
S. Tsuchida,
T. Ushiba,
T. Washimi,
T. Yamamoto
, et al. (1 additional authors not shown)
Abstract:
The Kamioka Gravitational wave detector (KAGRA) cryogenic gravitational-wave observatory has commenced joint observations with the worldwide gravitational wave detector network. Precise calibration of the detector response is essential for accurately estimating parameters of gravitational wave sources. A photon calibrator is a crucial calibration tool used in laser interferometer gravitational-wav…
▽ More
The Kamioka Gravitational wave detector (KAGRA) cryogenic gravitational-wave observatory has commenced joint observations with the worldwide gravitational wave detector network. Precise calibration of the detector response is essential for accurately estimating parameters of gravitational wave sources. A photon calibrator is a crucial calibration tool used in laser interferometer gravitational-wave observatory, Virgo, and KAGRA, and it was utilized in joint observation 3 with GEO600 in Germany in April 2020. In this paper, KAGRA implemented three key enhancements: a high-power laser, a power stabilization system, and remote beam position control. KAGRA employs a 20 W laser divided into two beams that are injected onto the mirror surface. By utilizing a high-power laser, the response of the detector at kHz frequencies can be calibrated. To independently control the power of each laser beam, an optical follower servo was installed for power stabilization. The optical path of the photon calibrator beam positions was controlled using pico-motors, allowing for the characterization of the detector rotation response. Additionally, a telephoto camera and quadrant photodetectors were installed to monitor beam positions, and beam position control was implemented to optimize the mirror response. In this paper, we discuss the statistical errors associated with the measurement of relative power noise. We also address systematic errors related to the power calibration model of the photon calibrator and the simulation of elastic deformation effects using finite element analysis. Ultimately, we have successfully reduced the total systematic error from the photon calibrator to 2.0 /%.
△ Less
Submitted 30 March, 2024; v1 submitted 23 February, 2023;
originally announced February 2023.
-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Cryogenic suspension design for a kilometer-scale gravitational-wave detector
Authors:
Takafumi Ushiba,
Tomotada Akutsu,
Yoichi Aso,
Sakae Araki,
Rishabh Bajpai,
Dan Chen,
Kieran Craig,
William Creus,
Yutaro Enomoto,
Yoshinori Fujii,
Masashi Fukunaga,
Ayako Hagiwara,
Sadakazu Haino,
Kunihiko Hasegawa,
Yuki Inoue,
Kiwamu Izumi,
Nobuhiro Kimura,
Keiko Kokeyama,
Rahul Kumar,
Ettore Majorana,
Yuta Michimura,
Takahiro Miyamoto,
Shinji Miyoki,
Iwao Murakami,
Yoshikazu Namai
, et al. (21 additional authors not shown)
Abstract:
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing th…
▽ More
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.
△ Less
Submitted 25 January, 2021; v1 submitted 5 October, 2020;
originally announced October 2020.
-
On the relation between active population and infection rate of COVID-19
Authors:
Takashi Shimada,
Yoshiyuki Suimon,
Kiyoshi Izumi
Abstract:
The relation between the number of passengers in the main stations and the infection rate of COVID19 in Tokyo is empirically studied. Our analysis based on conventional compartment model suggests: 1) Average time from the true day of infection to the day the infections are reported is about $15$ days. 2) The scaling relation between the density of active population and the infection rate suggests…
▽ More
The relation between the number of passengers in the main stations and the infection rate of COVID19 in Tokyo is empirically studied. Our analysis based on conventional compartment model suggests: 1) Average time from the true day of infection to the day the infections are reported is about $15$ days. 2) The scaling relation between the density of active population and the infection rate suggests that the increase of infection rate is linear to the active population rather than quadratic, as that is assumed in the conventional SIR model. 3) Notable deviations from the overall scaling relation seems to correspond to the change of the peoples's behavior in response to the public announcements of action regulation.
△ Less
Submitted 21 September, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
Angular response of a triangular optical cavity analyzed by a linear approximation method
Authors:
Satoshi Tanioka,
Gui-guo Ge,
Keiko Kokeyama,
Masayuki Nakano,
Junegyu Park,
Kiwamu Izumi
Abstract:
A triangular optical cavity is often used as a mode cleaning cavity in precision laser interferometry such as gravitational wave detectors. An alignment sensing and control system for maintaining the alignment of a mode cleaning cavity with respect to the incoming laser beam is critical for detector's performance. Therefore, understanding the behavior of the angular response is vital to both desig…
▽ More
A triangular optical cavity is often used as a mode cleaning cavity in precision laser interferometry such as gravitational wave detectors. An alignment sensing and control system for maintaining the alignment of a mode cleaning cavity with respect to the incoming laser beam is critical for detector's performance. Therefore, understanding the behavior of the angular response is vital to both design and commissioning test of the alignment control system. We present a linear approximation approach which not only simplifies the computation but also provides a comprehensive picture of the angular response. The observable degrees of freedom in a triangular cavity is discussed based on the linear approximation.
△ Less
Submitted 7 February, 2020;
originally announced February 2020.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
Design and experimental demonstration of a laser modulation system for future gravitational-wave detectors
Authors:
Kohei Yamamoto,
Keiko Kokeyama,
Yuta Michimura,
Yutaro Enomoto,
Masayuki Nakano,
Gui-Guo Ge,
Tomoyuki Uehara,
Kentaro Somiya,
Kiwamu Izumi,
Osamu Miyakawa,
Takahiro Yamamoto,
Takaaki Yokozawa,
Yuta Fujikawa,
Nobuyuki Fujii,
Takaaki Kajita
Abstract:
Detuning the signal-recycling cavity length from a cavity resonance significantly improves the quantum noise beyond the standard quantum limit, while there is no km-scale gravitational-wave detector successfully implemented the technique. The detuning technique is known to introduce great excess noise, and such noise can be reduced by a laser modulation system with two Mach-Zehnder interferometers…
▽ More
Detuning the signal-recycling cavity length from a cavity resonance significantly improves the quantum noise beyond the standard quantum limit, while there is no km-scale gravitational-wave detector successfully implemented the technique. The detuning technique is known to introduce great excess noise, and such noise can be reduced by a laser modulation system with two Mach-Zehnder interferometers in series. This modulation system, termed Mach-Zehnder Modulator (MZM), also makes the control of the gravitational-wave detector more robust by introducing the third modulation field which is non-resonant in any part of the main interferometer. On the other hand, mirror displacements of the Mach-Zehnder interferometers arise a new kind of noise source coupled to the gravitational-wave signal port. In this paper, the displacement noise requirement of the MZM is derived, and also results of our proof-of-principle experiment is reported.
△ Less
Submitted 16 August, 2019;
originally announced August 2019.
-
Dielectric cross-shaped resonator based metasurface for vortex beam generation in Mid-IR and THz wavelengths
Authors:
Raghu Dharmavarapu,
Ken-ichi Izumi,
Ikufumi Katayama,
SoonHock Ng,
Jitraporn Vongsvivut,
Mark J. Tobin,
AleksandrKuchmizhak,
Yoshiaki Nishijima,
Shanti Bhattacharya,
SauliusJuodkazis
Abstract:
Metasurfaces are engineered thin surfaces comprising two dimensional (2D) arrays of sub-wavelength spaced and sub-wavelength sized resonators. Metasurfaces can locally manipulate the amplitude, phase and polarization of light with high spatial resolution. In this study, we report numerical and experimental results of a vortex-beam-generating metasurface fabricated specifically for infrared (IR) an…
▽ More
Metasurfaces are engineered thin surfaces comprising two dimensional (2D) arrays of sub-wavelength spaced and sub-wavelength sized resonators. Metasurfaces can locally manipulate the amplitude, phase and polarization of light with high spatial resolution. In this study, we report numerical and experimental results of a vortex-beam-generating metasurface fabricated specifically for infrared (IR) and terahertz (THz) wavelengths. The designed metasurface consisted of a 2D array of dielectric cross-shaped resonators with spatially varying length, thereby providing desired spatially varying phase shift to the incident light. The metasurface was found to be insensitive to polarization of incident light. The dimensions of the cross-resonators were calculated using rigorous finite difference time domain (FDTD) analysis. The spectral scalability via physical scaling of meta resonators was demonstrated using two vortex generating optical elements operating at 8.8~$μ$m (IR) and 0.78~THz (Terahertz). The vortex beam generated in the mid-IR spectral range was imaged using FTIR imaging miscroscope equipped with a focal plane array (FPA) detector. This design could be used for efficient wavefront shaping as well as various optical imaging applications in mid-IR spectral range, where polarization insensitivity is desired.
△ Less
Submitted 24 June, 2019;
originally announced June 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient damping performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the damping performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Guided Lock of a Suspended Optical Cavity Enhanced by a Higher Order Extrapolation
Authors:
Kiwamu Izumi,
Koji Arai,
Daisuke Tatsumi,
Ryutaro Takahashi,
Osamu Miyakawa,
Masa-Katsu Fujimoto
Abstract:
Lock acquisition of a suspended optical cavity can be a highly stochastic process and is therefore nontrivial. Guided lock is a method to make lock acquisition less stochastic by decelerating the motion of the cavity length based on an extrapolation of the motion from an instantaneous velocity measurement. We propose an improved scheme which is less susceptible to seismic disturbances by incorpora…
▽ More
Lock acquisition of a suspended optical cavity can be a highly stochastic process and is therefore nontrivial. Guided lock is a method to make lock acquisition less stochastic by decelerating the motion of the cavity length based on an extrapolation of the motion from an instantaneous velocity measurement. We propose an improved scheme which is less susceptible to seismic disturbances by incorporating the acceleration as a higher order correction in the extrapolation. We implemented the new scheme in a 300-m suspended Fabry-Perot cavity and improved the success rate of lock acquisition by a factor of 30.
△ Less
Submitted 5 April, 2017;
originally announced April 2017.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
The Advanced LIGO Photon Calibrators
Authors:
S. Karki,
D. Tuyenbayev,
S. Kandhasamy,
B. P. Abbott,
T. D. Abbott,
E. H. Anders,
J. Berliner,
J. Betzwieser,
H. P. Daveloza,
C. Cahillane,
L. Canete,
C. Conley,
J. R. Gleason,
E. Goetz,
J. S. Kissel,
K. Izumi,
G. Mendell,
V. Quetschke,
M. Rodruck,
S. Sachdev,
T. Sadecki,
P. B. Schwinberg,
A. Sottile,
M. Wade,
A. J. Weinstein
, et al. (2 additional authors not shown)
Abstract:
The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generati…
▽ More
The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as Photon Calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO Photon Calibrators that are currently providing fiducial displacements on the order of $10^{-18}$ m/$\sqrt{\textrm{Hz}}$ with accuracy and precision of better than 1 %.
△ Less
Submitted 17 August, 2016;
originally announced August 2016.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Observation of Parametric Instability in Advanced LIGO
Authors:
Matthew Evans,
Slawek Gras,
Peter Fritschel,
John Miller,
Lisa Barsotti,
Denis Martynov,
Aidan Brooks,
Dennis Coyne,
Rich Abbott,
Rana Adhikari,
Koji Arai,
Rolf Bork,
Bill Kells,
Jameson Rollins,
Nicolas Smith-Lefebvre,
Gabriele Vajente,
Hiroaki Yamamoto,
Ryan Derosa,
Anamaria Effler,
Keiko Kokeyama,
Joseph Betzweiser,
Valera Frolov,
Adam Mullavey,
Sheila Dwyer,
Kiwamu Izumi
, et al. (19 additional authors not shown)
Abstract:
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrie…
▽ More
Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this work we describe the first observation of parametric instability in an Advanced LIGO detector, and the means by which it has been removed as a barrier to progress.
△ Less
Submitted 27 February, 2015; v1 submitted 20 February, 2015;
originally announced February 2015.
-
Multi-color Cavity Metrology
Authors:
Kiwamu Izumi,
Koji Arai,
Bryan Barr,
Joseph Betzwieser,
Aidan Brooks,
Katrin Dahl,
Suresh Doravari,
Jennifer C. Driggers,
W. Zach Korth,
Haixing Miao,
Jameson Rollins,
Stephen Vass,
David Yeaton-Massey,
Rana X. Adhikari
Abstract:
Long baseline laser interferometers used for gravitational wave detection have proven to be very complicated to control. In order to have sufficient sensitivity to astrophysical gravitational waves, a set of multiple coupled optical cavities comprising the interferometer must be brought into resonance with the laser field. A set of multi-input, multi-output servos then lock these cavities into pla…
▽ More
Long baseline laser interferometers used for gravitational wave detection have proven to be very complicated to control. In order to have sufficient sensitivity to astrophysical gravitational waves, a set of multiple coupled optical cavities comprising the interferometer must be brought into resonance with the laser field. A set of multi-input, multi-output servos then lock these cavities into place via feedback control. This procedure, known as lock acquisition, has proven to be a vexing problem and has reduced greatly the reliability and duty factor of the past generation of laser interferometers. In this article, we describe a technique for bringing the interferometer from an uncontrolled state into resonance by using harmonically related external fields to provide a deterministic hierarchical control. This technique reduces the effect of the external seismic disturbances by four orders of magnitude and promises to greatly enhance the stability and reliability of the current generation of gravitational wave detector. The possibility for using multi-color techniques to overcome current quantum and thermal noise limits is also discussed.
△ Less
Submitted 24 May, 2012; v1 submitted 6 May, 2012;
originally announced May 2012.
-
Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV
Authors:
Y. Asaoka,
K. Yoshimura,
T. Yoshida,
K. Abe,
K. Anraku,
M. Fujikawa,
H. Fuke,
S. Haino,
K. Izumi,
T. Maeno,
Y. Makida,
N. Matsui,
H. Matsumoto,
H. Matsunaga,
M. Motoki,
M. Nozaki,
S. Orito,
T. Sanuki,
M. Sasaki,
Y. Shikaze,
T. Sonoda,
J. Suzuki,
K. Tanaka,
Y. Toki,
A. Yamamoto
Abstract:
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic…
▽ More
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be $\pm$5%, compared with the previous estimation of $\pm$15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.
△ Less
Submitted 23 September, 2002; v1 submitted 1 May, 2001;
originally announced May 2001.