Source of pure proton beams
Authors:
S. V. Golubev,
I. V. Izotov,
V. A. Skalyga,
S. S. Vybin,
E. M. Kiseleva,
R. L. Lapin,
S. V. Razin,
A. F. Bokhanov,
M. Yu. Kazakov,
S. P. Shlepnev
Abstract:
In the quasi-gasdynamic high-current ion source described in this work, the plasma is sustained by high-power millimeter-wave radiation under the electron cyclotron resonance (ECR) condition. In such facilities, it is possible to achieve high volumetric energy input of up to $250$ $W/cm^3$ and obtain pure proton beams with a minimum amount of impurities and molecular ions. Experiments conducted on…
▽ More
In the quasi-gasdynamic high-current ion source described in this work, the plasma is sustained by high-power millimeter-wave radiation under the electron cyclotron resonance (ECR) condition. In such facilities, it is possible to achieve high volumetric energy input of up to $250$ $W/cm^3$ and obtain pure proton beams with a minimum amount of impurities and molecular ions. Experiments conducted on the GISMO facility demonstrated the possibility of a proton beam formation with a current of $50$ mA and an extremely high ($99.9$\%) content of atomic ions.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
High Power Vacuum Ultraviolet Source Based on Gasdynamic ECR Plasma
Authors:
R. L. Lapin,
V. A. Skalyga,
S. V. Golubev,
I. V. Izotov,
S. V. Razin
Abstract:
We report experimental results of vacuum ultraviolet (VUV) emission from the plasma of an electron cyclotron resonance (ECR) discharge in hydrogen, sustained by powerful millimeter-wavelength radiation of a gyrotron. Distinctive features of the considered discharge are the high plasma density ($10^{13}$ cm$^{-3}$ order of magnitude) and, at the same time, the high electron average energy (…
▽ More
We report experimental results of vacuum ultraviolet (VUV) emission from the plasma of an electron cyclotron resonance (ECR) discharge in hydrogen, sustained by powerful millimeter-wavelength radiation of a gyrotron. Distinctive features of the considered discharge are the high plasma density ($10^{13}$ cm$^{-3}$ order of magnitude) and, at the same time, the high electron average energy ($10 - 300$ eV), which makes it possible to significantly increase the efficiency of VUV re-emission of the energy deposited into the plasma by the microwave radiation. Experiments were performed with the plasma confined in a simple mirror trap and heated by pulsed gyrotron radiation $37.5$ GHz / $100$ kW under the ECR condition. The measured volumetric VUV emission power of Lyman-alpha line ($122 \pm 10$ nm) overlapping with the Werner band, Lyman band ($160 \pm 10$ nm), and molecular continuum ($180 \pm 20$ nm) reached $45$, $25$, and $55$ W/cm$^3$, respectively. The total absolute radiation power in these three ranges integrated over the plasma volume is estimated to be $22$ kW i.e. $22$% of the incident microwave power, which matches theoretical predictions. Further optimization of the conditions of the ECR hydrogen discharge sustained by powerful gyrotron radiation provides an opportunity for the development of effective technological VUV sources of a kilowatt power level.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
Experiments on intense ion beam formation with inhomogeneous electric field
Authors:
S. S. Vybin,
V. A. Skalyga,
I. V. Izotov,
S. V. Golubev,
S. V. Razin,
R. A. Shaposhnikov,
M. Yu. Kazakov,
A. F. Bokhanov,
S. P. Shlepnev
Abstract:
We report on a successful test of a new method for intense ion beam formation using an extraction with inhomogeneous electric field. Its key feature is a special shape of the extraction electrodes providing a higher rate of ion acceleration. It is applicable to any ion source type and could be used to improve performance of a wide range of plasma devices. The proof of concept was carried out using…
▽ More
We report on a successful test of a new method for intense ion beam formation using an extraction with inhomogeneous electric field. Its key feature is a special shape of the extraction electrodes providing a higher rate of ion acceleration. It is applicable to any ion source type and could be used to improve performance of a wide range of plasma devices. The proof of concept was carried out using a high-current electron-cyclotron resonance ion source SMIS 37. High efficiency of the new extraction and proton beam formation with a record current density of up to 1.1 A cm-2 was demonstrated.
△ Less
Submitted 22 July, 2021;
originally announced July 2021.
-
Status of a point-like neutron generator development
Authors:
S. V. Golubev,
V. A. Skalyga,
I. V. Izotov,
S. V. Razin,
R. A. Shaposhnikov,
S. S. Vybin,
A. F. Bokhanov,
M. Yu. Kazakov,
S. P. Shlepnev,
K. F. Burdonov,
A. A. Soloviev,
M. V. Starodubtsev
Abstract:
In this paper we report on a high current density ion beam profile diagnostics with a slit-based system as a reliable method, capable of high thermal load applications. The task arose in frames of a point-like neutron source development for neutron radiography. In previous research, it was suggested to construct such a system as a D-D neutron generator based on the high current gasdynamic ion sour…
▽ More
In this paper we report on a high current density ion beam profile diagnostics with a slit-based system as a reliable method, capable of high thermal load applications. The task arose in frames of a point-like neutron source development for neutron radiography. In previous research, it was suggested to construct such a system as a D-D neutron generator based on the high current gasdynamic ion source, which utilises the plasma of electron cyclotron resonance discharge sustained by powerful millimeter wave gyrotron radiation. This device is able to produce focused D+ beams with a characteristic diameter of 1 mm, total current above 100 mA, and current density at a level of several A/cm^2. Study of such intense beams profile to obtain the best focusing efficiency and minimize neutron producing area appeared to be a challenging task. The paper also demonstrates the possibility of fast neutron imaging with a point-like powerful neutron generator (neutron yield on the level of 10^10 1/s).
△ Less
Submitted 21 December, 2020; v1 submitted 10 December, 2020;
originally announced December 2020.
-
Towards explanation of the two-frequency heating effect in electron cyclotron ion sources
Authors:
A. G. Shalashov,
E. D. Gospodchikov,
I. V. Izotov,
V. A. Skalyga
Abstract:
The quasilinear model of electron cyclotron resonance (ECR) heating in a mirror magnetic field predicts essential broadening of the electron distribution function in case of bichromatic wave. This may stabilize kinetic instabilities in the electron-cyclotron frequency range resulting in improved performance of ECR ion sources, the effect which is observed in many independent experiments.
The quasilinear model of electron cyclotron resonance (ECR) heating in a mirror magnetic field predicts essential broadening of the electron distribution function in case of bichromatic wave. This may stabilize kinetic instabilities in the electron-cyclotron frequency range resulting in improved performance of ECR ion sources, the effect which is observed in many independent experiments.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Controlled turbulence regime of electron cyclotron resonance ion source for improved multicharged ion performance
Authors:
V. A. Skalyga,
I. V. Izotov,
A. G. Shalashov,
E. D. Gospodchikov,
E. M. Kiseleva,
O. Tarvainen,
H. Koivisto,
V. Toivanen
Abstract:
Fundamental studies of excitation and non-linear evolution of kinetic instabilities of strongly nonequlibrium hot plasmas confined in open magnetic traps suggest new opportunities for fine-tuning of conventional electron cyclotron resonance (ECR) ion sources. These devices are widely used for the production of particle beams of high charge state ions. Operating the ion source in controlled turbule…
▽ More
Fundamental studies of excitation and non-linear evolution of kinetic instabilities of strongly nonequlibrium hot plasmas confined in open magnetic traps suggest new opportunities for fine-tuning of conventional electron cyclotron resonance (ECR) ion sources. These devices are widely used for the production of particle beams of high charge state ions. Operating the ion source in controlled turbulence regime allows increasing the absorbed power density and therefore the volumetric plasma energy content in the dense part of the discharge surrounded by the ECR surface, which leads to enhanced beam currents of high charge state ions. We report experiments at the ECR ion source at the JYFL accelerator laboratory, in which adopting of a new approach allows to increase the multicharged ion beam current up to two times, e.g. to 95 $μ$A of O$^{7+}$ achieved with mere 280 W power at 11.56 GHz. A theoretical model supporting and explaining the experimental findings is presented. The study suggests that the controlled turbulence regime has the potential to enhance the beam currents of modern high-performance ion sources, including state-of-the-art superconducting devices.
△ Less
Submitted 9 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
The role of rf-scattering in high-energy electron losses from minimum-B ECR ion source
Authors:
I. V. Izotov,
A. G. Shalashov,
V. A. Skalyga,
E. D. Gospodchikov,
O. Tarvainen,
V. E. Mironov,
H. Koivisto,
R. Kronholm,
V. Toivanen,
B. Bhaskar
Abstract:
The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4-800 keV is reported. The experiments have revealed the existence of a hump at 150-300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microw…
▽ More
The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4-800 keV is reported. The experiments have revealed the existence of a hump at 150-300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microwave power, frequency and neutral gas pressure but increases with the magnetic field strength, most importantly with the value of the minimum-B field. Experiments in pulsed operation mode have indicated the presence of the hump only when microwave power is applied, confirming that the origin of the hump is rf-induced momentum space diffusion. Possible mechanism of the hump formation is considered basing on the quasi-linear model of plasma-wave interaction.
△ Less
Submitted 8 December, 2020; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Observation of Poincaré-Andronov-Hopf bifurcation in cyclotron maser emission from plasma magnetic trap
Authors:
A. G. Shalashov,
E. D. Gospodchikov,
I. V. Izotov,
D. A. Mansfeld,
V. A. Skalyga,
O. Tarvainen
Abstract:
We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic emission into continuous wave regime of a cyclotron maser formed in magnetically confined non-equilibrium plasmas. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulti…
▽ More
We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic emission into continuous wave regime of a cyclotron maser formed in magnetically confined non-equilibrium plasmas. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in MHD-stable minimum-B open magnetic trap.
△ Less
Submitted 18 December, 2017;
originally announced December 2017.