System Design of the Newest Generation Detector Controller for ELT and new VLT Instruments
Authors:
Mathias Richerzhagen,
Matthias Seidel,
Leander Mehrgan,
Derek Ives,
Ralf Conzelmann,
Mirko Todorovic,
Christoph Geimer
Abstract:
A new detector controller, NGCII, is in development for the first-generation instruments of the ELT as well as new instruments for the VLT. Building on experience with previous ESO detector controllers, a modular system based on the MicroTCA.4 industrial standard, is designed to control a variety of infrared and visible light scientific and wavefront sensor detectors. This article presents the ear…
▽ More
A new detector controller, NGCII, is in development for the first-generation instruments of the ELT as well as new instruments for the VLT. Building on experience with previous ESO detector controllers, a modular system based on the MicroTCA.4 industrial standard, is designed to control a variety of infrared and visible light scientific and wavefront sensor detectors. This article presents the early development stages of NGCII hardware and firmware from the decision to start an all-new design to first tests with detectors and ROICs.
△ Less
Submitted 30 October, 2024;
originally announced October 2024.
-
Evaluating the GeoSnap 13-$μ$m Cut-Off HgCdTe Detector for mid-IR ground-based astronomy
Authors:
Jarron M. Leisenring,
Dani Atkinson,
Rory Bowens,
Vincent Douence,
William F. Hoffmann,
Michael R. Meyer,
John Auyeung,
James Beletic,
Mario S. Cabrera,
Alexandra Z. Greenbaum,
Phil Hinz,
Derek Ives,
William J. Forrest,
Craig W. McMurtry,
Judith L. Pipher,
Eric Viges
Abstract:
New mid-infrared HgCdTe (MCT) detector arrays developed in collaboration with Teledyne Imaging Sensors (TIS) have paved the way for improved 10-$μ$m sensors for space- and ground-based observatories. Building on the successful development of longwave HAWAII-2RGs for space missions such as NEO Surveyor, we characterize the first 13-$μ$m GeoSnap detector manufactured to overcome the challenges of hi…
▽ More
New mid-infrared HgCdTe (MCT) detector arrays developed in collaboration with Teledyne Imaging Sensors (TIS) have paved the way for improved 10-$μ$m sensors for space- and ground-based observatories. Building on the successful development of longwave HAWAII-2RGs for space missions such as NEO Surveyor, we characterize the first 13-$μ$m GeoSnap detector manufactured to overcome the challenges of high background rates inherent in ground-based mid-IR astronomy. This test device merges the longwave HgCdTe photosensitive material with Teledyne's 2048x2048 GeoSnap-18 (18-$μ$m pixel) focal plane module, which is equipped with a capacitive transimpedance amplifier (CTIA) readout circuit paired with an onboard 14-bit analog-to-digital converter (ADC). The final assembly yields a mid-IR detector with high QE, fast readout (>85 Hz), large well depth (>1.2 million electrons), and linear readout.
Longwave GeoSnap arrays would ideally be deployed on existing ground-based telescopes as well as the next generation of extremely large telescopes. While employing advanced adaptive optics (AO) along with state-of-the-art diffraction suppression techniques, instruments utilizing these detectors could attain background- and diffraction-limited imaging at inner working angles <10 $λ/D$, providing improved contrast-limited performance compared to JWST MIRI while operating at comparable wavelengths. We describe the performance characteristics of the 13-$μ$m GeoSnap array operating between 38 and 45K, including quantum efficiency, well depth, linearity, gain, dark current, and frequency-dependent (1/f) noise profile.
△ Less
Submitted 17 July, 2023; v1 submitted 8 June, 2023;
originally announced June 2023.
-
Performance advantages of buffered mode operation of HxRG near infrared detectors
Authors:
Naidu Bezawada,
Derek Ives,
Domingo Alvarez,
Benoît Serra,
Elizabeth George,
Christopher Mandla,
Leander Mehrgan
Abstract:
The Teledyne HxRG detectors have versatile and programmable output options to allow operation of them in a variety of configurations such as slow unbuffered, slow buffered, fast buffered or unbuffered modes to optimise the detector performance for a given application. Normally at ESO, for low noise operation, the detectors are operated in slow unbuffered mode. Whilst the slow unbuffered mode offer…
▽ More
The Teledyne HxRG detectors have versatile and programmable output options to allow operation of them in a variety of configurations such as slow unbuffered, slow buffered, fast buffered or unbuffered modes to optimise the detector performance for a given application. Normally at ESO, for low noise operation, the detectors are operated in slow unbuffered mode. Whilst the slow unbuffered mode offers a simple interface to the external preamplifier electronics, the detector operation in this mode can suffer from reduced pixel frequency response and higher electrical crosstalk between the readout channels. In the context of the detector systems required for the first generation instruments of the ELT (MICADO, HARMONI and METIS), an exercise was undertaken to evaluate the noise, speed and crosstalk performance of the detectors in the slow buffered mode. A test preamplifier has been designed with options to operate a H2RG detector in buffered or unbuffered and with or without using the reference output, so a direct performance comparison can be made between different modes. This paper presents the performance advantages such as increased pixel frequency response, elimination of electrical crosstalk between the readout channels and the noise performance in the buffered mode operation. These improvements allow us to achieve the same frame readout time using half the detector cryogenic electronics and detector controller electronics for the ELT instruments, which significantly reduces the associated cryomechanical complexities in the instrument.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
Characterisation, performance, and operational aspects of the H4RG-15 near infrared detectors for the MOONS instrument
Authors:
Derek Ives,
Domingo Alvarez,
Naidu Bezawada,
Elizabeth George,
Benoît Serra
Abstract:
MOONS is a multi-object spectrograph for the ESO VLT covering a simultaneous wavelength range of 0.6-1.8 microns using approximately 1000 fibres. It uses four Teledyne Imaging Systems H4RG-15 4K x 4K detectors with 2.5 $μ$m cut-off material for the two longer wavebands (YJ and H). Since the spectrographs utilize an extremely fast modified Schmidt camera design, then the detectors are situated in t…
▽ More
MOONS is a multi-object spectrograph for the ESO VLT covering a simultaneous wavelength range of 0.6-1.8 microns using approximately 1000 fibres. It uses four Teledyne Imaging Systems H4RG-15 4K x 4K detectors with 2.5 $μ$m cut-off material for the two longer wavebands (YJ and H). Since the spectrographs utilize an extremely fast modified Schmidt camera design, then the detectors are situated in the optical beam and hence required the development of a novel 64- channel cryogenic differential cryogenic preamplifier, minimized for optical footprint which will be reported on. We have operated the Engineering Grade H4RG detector at a range of temperatures from 90K to 40K and we will report on the advantages of the lower operational temperature. We have completed a full persistence analysis and are able to model it reasonably well and will offer a correction for it in our data pipeline. We have also configured the detector for use with both unbuffered and buffered outputs and report on the differences in performance between the two output types. We have also seen some programming issues with the detector type and will report on our work-around for this, we will also describe the use of the column-deselect feature and row skipping to minimize the effects of PEDs. We have also measured charge injection per read and report on this, likewise we have also measured the inter-pixel capacitance in different regions of the detector. We will present all these results together with a summary of the complete performance characteristics of this detector family.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
Detector Systems Engineering for Extremely Large Instruments
Authors:
Elizabeth M. George,
Naidu Bezawada,
Derek Ives,
Leander Mehrgan,
Matteo Accardo,
Domingo Alvarez,
Martin Brinkmann,
Ralf Conzelmann,
Claudio Cumani,
Mark Downing,
Max Engelhardt,
Marcus Haug,
Joshua Hopgood,
Christoph Geimer,
Olaf Iwert,
Barbara Klein,
Christopher Mandla,
Eric Müller,
Suzanne Ramsay,
Javier Reyes,
Mathias Richerzhagen,
Benoît Serra,
Matthias Seidel,
Jörg Stegmeier,
Mirko Todorovic
Abstract:
The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $μ$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $μ$m cutoff H2RG detectors, and one 13.5 $μ$m cutoff GEOSNAP detector. This challenging program of scientific detector system development covers everything from designing and…
▽ More
The scientific detector systems for the ESO ELT first-light instruments, HARMONI, MICADO, and METIS, together will require 27 science detectors: seventeen 2.5 $μ$m cutoff H4RG-15 detectors, four 4K x 4K 231-84 CCDs, five 5.3 $μ$m cutoff H2RG detectors, and one 13.5 $μ$m cutoff GEOSNAP detector. This challenging program of scientific detector system development covers everything from designing and producing state-of-the-art detector control and readout electronics, to developing new detector characterization techniques in the lab, to performance modeling and final system verification. We report briefly on the current design of these detector systems and developments underway to meet the challenging scientific performance goals of the ELT instruments.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
Fast method of crosstalk characterization for HxRG detectors
Authors:
Elizabeth M. George,
Simon M. Tulloch,
Derek J. Ives
Abstract:
HxRG detectors have crosstalk between amplifier channels at a scientifically relevant level. In principle, crosstalk signals can be fully calibrated and removed from data, but only if a full crosstalk matrix is measured for the detector. We present a fast method of crosstalk characterization that can be performed with most instrument calibration units; it requires only a flat-field illumination an…
▽ More
HxRG detectors have crosstalk between amplifier channels at a scientifically relevant level. In principle, crosstalk signals can be fully calibrated and removed from data, but only if a full crosstalk matrix is measured for the detector. We present a fast method of crosstalk characterization that can be performed with most instrument calibration units; it requires only a flat-field illumination and window programming in the HxRG detectors. We show the crosstalk matrices obtained with this method for both fast and slow mode in an H2RG detector, and give examples of how this data can be used to tune detector operation parameters, feed back into the electronics design for the cryogenic pre-amplifiers, and be used in the data pipeline to remove crosstalk signal from scientific data.
△ Less
Submitted 15 November, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
The Benefit of Split Nonlinearity Compensation for Optical Fiber Communications
Authors:
Domanic Lavery,
David Ives,
Gabriele Liga,
Alex Alvarado,
Seb J. Savory,
Polina Bayvel
Abstract:
In this Letter we analyze the benefit of digital compensation of fiber nonlinearity, where the digital signal processing is divided between the transmitter and receiver. The application of the Gaussian noise model indicates that, where there are two or more spans, it is always beneficial to split the nonlinearity compensation. The theory is verified via numerical simulations, investigating transmi…
▽ More
In this Letter we analyze the benefit of digital compensation of fiber nonlinearity, where the digital signal processing is divided between the transmitter and receiver. The application of the Gaussian noise model indicates that, where there are two or more spans, it is always beneficial to split the nonlinearity compensation. The theory is verified via numerical simulations, investigating transmission of single channel 50 GBd polarization division multiplexed 256-ary quadrature amplitude modulation over 100 km standard single mode fiber spans, using lumped amplification. For this case, the additional increase in mutual information achieved over transmitter- or receiver-side nonlinearity compensation is approximately 1 bit for distances greater than 2000 km. Further, it is shown, theoretically, that the SNR gain for long distances and high bandwidth transmission is 1.5 dB versus transmitter- or receiver-based nonlinearity compensation.
△ Less
Submitted 12 November, 2015;
originally announced November 2015.
-
On the Impact of Optimal Modulation and FEC Overhead on Future Optical Networks
Authors:
Alex Alvarado,
David J. Ives,
Seb Savory,
Polina Bayvel
Abstract:
The potential of optimum selection of modulation and forward error correction (FEC) overhead (OH) in future transparent nonlinear optical mesh networks is studied from an information theory perspective. Different network topologies are studied as well as both ideal soft-decision (SD) and hard-decision (HD) FEC based on demap-and-decode (bit-wise) receivers. When compared to the de-facto QPSK with…
▽ More
The potential of optimum selection of modulation and forward error correction (FEC) overhead (OH) in future transparent nonlinear optical mesh networks is studied from an information theory perspective. Different network topologies are studied as well as both ideal soft-decision (SD) and hard-decision (HD) FEC based on demap-and-decode (bit-wise) receivers. When compared to the de-facto QPSK with 7% OH, our results show large gains in network throughput. When compared to SD-FEC, HD-FEC is shown to cause network throughput losses of 12%, 15%, and 20% for a country, continental, and global network topology, respectively. Furthermore, it is shown that most of the theoretically possible gains can be achieved by using one modulation format and only two OHs. This is in contrast to the infinite number of OHs required in the ideal case. The obtained optimal OHs are between 5% and 80%, which highlights the potential advantage of using FEC with high OHs.
△ Less
Submitted 20 August, 2015; v1 submitted 19 August, 2015;
originally announced August 2015.