-
Resolution Enhancement in Protein NMR Spectra by Deconvolution with Compressed Sensing Reconstruction
Authors:
Krzysztof Kazimierczuk,
Paweł Kasprzak,
Panagiota S. Georgoulia,
Irena Burmann,
Björn M. Burmann,
Linnéa Isaksson,
Emil Gustavsson,
Sebastian Westenhoff,
Vladislav Yu. Orekhov
Abstract:
Multidimensional NMR spectroscopy is one of the basic tools for determining the structure of biomolecules. Unfortunately, the resolution of the spectra is often limited by inter-nuclear couplings. This limitation cannot be overcome by common ways of increasing resolution, i.e. non-uniform sampling (NUS) followed by compressed sensing (CS) reconstruction. In this paper, we show how to enrich CS pro…
▽ More
Multidimensional NMR spectroscopy is one of the basic tools for determining the structure of biomolecules. Unfortunately, the resolution of the spectra is often limited by inter-nuclear couplings. This limitation cannot be overcome by common ways of increasing resolution, i.e. non-uniform sampling (NUS) followed by compressed sensing (CS) reconstruction. In this paper, we show how to enrich CS processing with virtual decoupling leading to an increase in resolution, sensitivity, and overall quality of NUS reconstruction. A mathematical description of the decoupling by deconvolution approach explains the effects of noise, modulation of the sampling schedule, and reveals relation with the underlying assumption of the CS. The gain in resolution and sensitivity is demonstrated for the basic experiment used for protein backbone assignment 3D HNCA applied to two large protein systems: intrinsically disordered 441-residue Tau and a 509-residue globular bacteriophytochrome fragment.
△ Less
Submitted 11 September, 2020;
originally announced September 2020.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
A Helium Gas-Scintillator Active Target for Photoreaction Measurements
Authors:
R. Al Jebali,
J. R. M. Annand,
J. -O. Adler,
I. Akkurt,
E. Buchanan,
J. Brudvik,
K. Fissum,
S. Gardner,
D. J. Hamilton,
K. Hansen,
L. Isaksson,
K. Livingston,
M. Lundin,
J. C. McGeorge,
I. J. D. MacGregor,
R. MacRae,
D. G. Middleton,
A. J. H. Reiter,
G. Rosner,
B. Schröder,
J. Sjögren,
D. Sokhan,
B. Strandberg
Abstract:
A multi-cell He gas-scintillator active target, designed for the measurement of photoreaction cross sections, is described. The target has four main chambers, giving an overall thickness of 0.103 $\mathrm{g/cm^{2}}$ at an operating pressure of 2 MPa. Scintillations are read out by photomultiplier tubes and the addition of small amounts of $\mathrm{N}_{2}$ to the He, to shift the scintillation emis…
▽ More
A multi-cell He gas-scintillator active target, designed for the measurement of photoreaction cross sections, is described. The target has four main chambers, giving an overall thickness of 0.103 $\mathrm{g/cm^{2}}$ at an operating pressure of 2 MPa. Scintillations are read out by photomultiplier tubes and the addition of small amounts of $\mathrm{N}_{2}$ to the He, to shift the scintillation emission from UV to visible, is discussed. First results of measurements at the MAX IV Laboratory tagged-photon facility show that the target has good timing resolution and can cope well with a high-flux photon beam. The determination of reaction cross sections from target yields relies on a Monte Carlo simulation, which considers scintillation light transport, photodisintegration processes in $^{4}\mathrm{He}$, background photon interactions in target windows and interactions of the reaction-product particles in the gas and target container. The predictions of this simulation are compared to the measured target response.
△ Less
Submitted 18 March, 2015;
originally announced March 2015.
-
Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
Authors:
M. F. Preston,
L. S. Myers,
J. R. M. Annand,
K. G. Fissum,
K. Hansen,
L. Isaksson,
R. Jebali,
M. Lundin
Abstract:
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs.…
▽ More
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs. The agreement between results obtained from data taken using single-hit and multi-hit TDCs demonstrate a thorough understanding of the behavior of the detector system.
△ Less
Submitted 22 November, 2013;
originally announced November 2013.
-
Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
Authors:
L. S. Myers,
G. Feldman,
K. G. Fissum,
L. Isaksson,
M. A. Kovash,
A. M. Nathan,
R. E. Pywell,
B. Schröder
Abstract:
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.
△ Less
Submitted 3 August, 2013; v1 submitted 16 March, 2013;
originally announced March 2013.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.