Analysis of a Casimir-driven Parametric Amplifier with Resilience to Casimir Pull-in for MEMS Single-Point Magnetic Gradiometry
Authors:
Josh Javor,
Zhancheng Yao,
Matthias Imboden,
David K. Campbell,
David J. Bishop
Abstract:
The Casimir Force, a quantum mechanical effect, has been observed in several microelectromechanical systems (MEMS) platforms. Due to its extreme sensitivity to the separation of two objects, the Casimir Force has been proposed as an excellent avenue for quantum metrology. Practical application, however, is challenging due to attractive forces leading to stiction and failure of the device, called C…
▽ More
The Casimir Force, a quantum mechanical effect, has been observed in several microelectromechanical systems (MEMS) platforms. Due to its extreme sensitivity to the separation of two objects, the Casimir Force has been proposed as an excellent avenue for quantum metrology. Practical application, however, is challenging due to attractive forces leading to stiction and failure of the device, called Casimir pull-in. In this work, we design and simulate a Casimir-driven metrology platform, where a time-delay based parametric amplification technique is developed to achieve a steady state and avoid pull-in. We apply the design to the detection of weak, low frequency, gradient magnetic fields, similar to those emanating from ionic currents in the heart and brain. Simulation parameters are selected from recent experimental platforms developed for Casimir metrology and magnetic gradiometry, both on MEMS platforms. While MEMS offer many advantages to such an application, the detected signal must typically be at the resonant frequency of the device, with diminished sensitivity in the low frequency regime of biomagnetic fields. Using a Casimir-drive parametric amplifier, we report a 10,000 fold improvement in the best-case resolution of MEMS single-point gradiometers, with a maximum sensitivity of 6 Hz/(pT/cm) at 1 Hz. The development of the proposed design has the potential to revolutionize metrology, and specifically may enable unshielded monitoring of biomagnetic fields in ambient conditions.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Searching for the Casimir Energy
Authors:
Diego Pérez-Morelo,
Alexander Stange,
Richard W. Lally,
Lawrence K. Barrett,
Matthias Imboden,
David K. Campbell,
Vladimir A. Aksyuk,
David J. Bishop
Abstract:
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between…
▽ More
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between the two surfaces. In this new set of experiments, we aim to directly detect shifts in the Casimir $\textit{energy}$ in the vacuum due to the presence of metallic parallel plates, one of which is a superconductor. A change in the Casimir energy of this configuration is predicted to shift the superconducting transition temperature (T$_\textrm{c}$) because of an interaction between it and the superconducting condensation energy. The experiment we discuss consists of taking a superconducting film, carefully measuring its transition temperature, bringing a conducting plate close to the film, creating a Casimir cavity, and then measuring the transition temperature again. The expected shifts will be small, comparable to the normal shifts one sees in cycling superconducting films to cryogenic temperatures and so using a NEMS resonator and doing this in situ is the only practical way to obtain accurate, reproducible data. Using a thin Pb film and opposing Au surface, we observe no shift in T$_\textrm{c}$ greater than 12 $μ$K down to a minimum spacing of approximately 70 nm.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Building a Casimir Metrology Platform with a Commercial MEMS Accelerometer
Authors:
Alexander Stange,
Matthias Imboden,
Josh Javor,
Lawrence K. Barrett,
David J. Bishop
Abstract:
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charg…
▽ More
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charged. In this paper we observe the Casimir Effect in ambient conditions using a modified capacitive MEMS accelerometer. Using a feedback assisted pick-and-place assembly process we are able to attach various micro-structures onto the post-release MEMS, converting it from an inertial force sensor to a direct force measurement platform with pN resolution. With this system we are able to directly measure the Casimir force between a silver-coated microsphere and gold-coated silicon plate. This device is a step towards leveraging the Casimir Effect for cheap, sensitive, room temperature quantum metrology.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
High Performance, Continuously Tunable Microwave Filters using MEMS Devices with Very Large, Controlled, Out-of-Plane Actuation
Authors:
Jackson Chang,
Michael Holyoak,
George Kannell,
Marc Beacken,
Matthias Imboden,
David J. Bishop
Abstract:
Software defined radios (SDR) in the microwave X and K bands offer the promise of low cost, programmable operation with real-time frequency agility. However, the real world in which such radios operate requires them to be able to detect nanowatt signals in the vicinity of 100 kW transmitters. This imposes the need for selective RF filters on the front end of the receiver to block the large, out of…
▽ More
Software defined radios (SDR) in the microwave X and K bands offer the promise of low cost, programmable operation with real-time frequency agility. However, the real world in which such radios operate requires them to be able to detect nanowatt signals in the vicinity of 100 kW transmitters. This imposes the need for selective RF filters on the front end of the receiver to block the large, out of band RF signals so that the finite dynamic range of the SDR is not overwhelmed and the desired nanowatt signals can be detected and digitally processed. This is currently typically done with a number of narrow band filters that are switched in and out under program control. What is needed is a small, fast, wide tuning range, high Q, low loss filter that can continuously tune over large regions of the microwave spectrum. In this paper we show how extreme throw MEMS actuators can be used to build such filters operating up to 15 GHz and beyond. The key enabling attribute of our MEMS actuators is that they have large, controllable, out-of-plane actuation ranges of a millimeter or more. In a capacitance-post loaded cavity filter geometry, this gives sufficient precisely controllable motion to produce widely tunable devices in the 4-15 GHz regime.
△ Less
Submitted 13 May, 2018; v1 submitted 23 April, 2018;
originally announced April 2018.
-
High speed control of electro-mechanical transduction Advanced Drive Techniques for Optimized Step-and-Settle Response of MEMS Micromirrors
Authors:
Matthias Imboden,
Jackson Chang,
Corey Pollock,
Evan Lowell,
Mehmet Akbulut,
Jessica Morrison,
Thomas Stark,
Thomas G. Bifano,
David J. Bishop
Abstract:
Micro/Nano Electro Mechanical Systems (MEMS/NEMS) provide the engineer with a powerful set of solutions to a wide variety of technical challenges. However, because they are mechanical systems, response times can be a limitation. In some situations, advanced engineered drive techniques can improve response times by as much as a thousand, significantly opening up the application space for MEMS/NEMS…
▽ More
Micro/Nano Electro Mechanical Systems (MEMS/NEMS) provide the engineer with a powerful set of solutions to a wide variety of technical challenges. However, because they are mechanical systems, response times can be a limitation. In some situations, advanced engineered drive techniques can improve response times by as much as a thousand, significantly opening up the application space for MEMS/NEMS solutions.
△ Less
Submitted 24 May, 2016; v1 submitted 15 December, 2015;
originally announced December 2015.
-
Design of a Casimir-driven parametric amplifier
Authors:
M. Imboden,
J. Morrison,
D. K. Campbell,
D. J. Bishop
Abstract:
In this paper, we discuss a design for a MEMS parametric amplifier modulated by the Casimir force. We present the theory for such a device and show that it allows for the implementation of a very sensitive voltage measuring technique, where the amplitude of a high quality factor resonator includes a tenth power dependency on an applied DC voltage. This approach opens up a new and powerful measurin…
▽ More
In this paper, we discuss a design for a MEMS parametric amplifier modulated by the Casimir force. We present the theory for such a device and show that it allows for the implementation of a very sensitive voltage measuring technique, where the amplitude of a high quality factor resonator includes a tenth power dependency on an applied DC voltage. This approach opens up a new and powerful measuring modality, applicable to other measurement types.
△ Less
Submitted 4 September, 2014; v1 submitted 12 April, 2014;
originally announced April 2014.