-
Development and Implementation of Advanced Beam Diagnostic and Abort Systems in SuperKEKB
Authors:
Keisuke Yoshihara,
Tetsuro Abe,
Michele Aversano,
Alexander Gale,
Hitomi Ikeda,
Hiroshi Kaji,
Hidekazu Kakuno,
Taichiro Koga,
Toru Iijima,
Shinnosuke Kato,
Ami Kusudo,
Yuxin Liu,
Akane Maeda,
Sayan Mitra,
Gaku Mitsuka,
Kenkichi Miyabayashi,
Isamu Nakamura,
Hiroyuki Nakayama,
Yu Nakazawa,
Riku Nomaru,
Iori Okada,
Xiao-Dong Shi,
Shuji Tanaka,
Kenta Uno,
Yutaka Ushiroda
, et al. (2 additional authors not shown)
Abstract:
The SuperKEKB/Belle II experiment aims to collect high-statistics data of B meson pairs to explore new physics beyond the Standard Model (SM). SuperKEKB, an upgraded version of the KEKB accelerator, has achieved a world-record luminosity of $4.71 \times 10^{34} \, \mathrm{cm^{-2}s^{-1}}$ in 2022 but continues to strive for higher luminosities. One of the major obstacles is Sudden Beam Loss (SBL) e…
▽ More
The SuperKEKB/Belle II experiment aims to collect high-statistics data of B meson pairs to explore new physics beyond the Standard Model (SM). SuperKEKB, an upgraded version of the KEKB accelerator, has achieved a world-record luminosity of $4.71 \times 10^{34} \, \mathrm{cm^{-2}s^{-1}}$ in 2022 but continues to strive for higher luminosities. One of the major obstacles is Sudden Beam Loss (SBL) events, which cause substantial beam losses and damage to the Belle~II detector. To find a hint for addressing SBL challenges, advanced beam diagnostic systems and enhanced beam abort systems have been developed. The diagnostic system aims to accurately pinpoint the start of beam losses, while the upgraded abort system quickly disposes of anomalous beams to minimize damage.
This paper details the development and implementation of these systems, including high-speed loss monitors, time synchronization with the White Rabbit system, and data acquisition systems. Efforts to understand the mechanisms of SBL events, using acoustic sensors to detect discharges, are also discussed. These measures aim to improve the operational stability and luminosity of SuperKEKB, contributing to the experiment's success.
△ Less
Submitted 24 September, 2024; v1 submitted 28 August, 2024;
originally announced August 2024.
-
Development of a method to measure trace level of uranium and thorium in scintillation films
Authors:
K. Ichimura,
K. Chiba,
Y. Gando,
H. Ikeda,
Y. Kishimoto,
M. Kurasawa,
K. Nemoto,
A. Sakaguchi,
Y. Takaku,
Y. Sakakieda
Abstract:
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, in…
▽ More
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, including the pretreatment of the samples and labware, detection limit of the method, collection efficiencies of $^{238}$U and $^{232}$Th, and measurement of $^{238}$U and $^{232}$Th in a polyethylene naphthalate film. This method is also applicable to $^{238}$U and $^{232}$Th measurements in other low-background organic materials for rare event search experiments.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Search for Charged Excited States of Dark Matter with KamLAND-Zen
Authors:
KamLAND-Zen collaboration,
:,
S. Abe,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
S. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake,
D. Morita,
T. Nakahata
, et al. (44 additional authors not shown)
Abstract:
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making…
▽ More
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making large liquid scintillator detectors suitable for detection. We searched for bound-state formation events with xenon in two experimental phases of the KamLAND-Zen experiment, a xenon-doped liquid scintillator detector. No statistically significant events were observed. For a benchmark parameter set of WIMP mass $m_{χ^{0}} = 1$ TeV and mass difference $Δm = 17$ MeV, we set the most stringent upper limits on the recombination cross section times velocity $\langleσv\rangle$ and the decay-width of $χ^{-}$ to $9.2 \times 10^{-30}$ ${\rm cm^3/s}$ and $8.7 \times 10^{-14}$ GeV, respectively at 90% confidence level.
△ Less
Submitted 3 July, 2024; v1 submitted 16 November, 2023;
originally announced November 2023.
-
Radiopurity of NaI(Tl) crystals for PICOLON dark matter experiment
Authors:
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Fushimi,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ito,
T. Kishimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Intera…
▽ More
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Interacting Massive Particles (WIMPs) using NaI(Tl) crystals. Our NaI(Tl) crystal manufactured in 2020 (Ingot #85) reached the same purity level as DAMA/LIBRA crystals. In this report, we describe the radiopurity of the new Ingot #94 crystal produced using the same purification technique as Ingot #85. The $α$-ray events were selected by pulse-shape discrimination method. The impurities in the Ingot #94, $^{232}$Th, $^{226}$Ra and $^{210}$Po radioactivity were $4.6\pm 1.2~\mathrm{μBq/kg}$, $7.9\pm 4.4~\mathrm{μBq/kg}$, and $19\pm 6~\mathrm{μBq/kg}$, which are equivalent to those of the DAMA/LIBRA crystals. The background rate in the energy region of 2-6 keV , was 2-5 events/d/kg/keV without applying a veto trigger.
△ Less
Submitted 29 September, 2024; v1 submitted 25 September, 2023;
originally announced September 2023.
-
Development of a low-background HPGe detector at Kamioka Observatory
Authors:
K. Ichimura,
H. Ikeda,
Y. Kishimoto,
M. Kurasawa,
A. A. Suzuki,
Y. Gando,
M. Ikeda,
K. Hosokawa,
H. Sekiya,
H. Ito,
A. Minamino,
S. Suzuki
Abstract:
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the first HPGe detector installed in 2016, which has the same detector specification and similar shielding geometry. This paper describes the shielding configuration, i…
▽ More
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the first HPGe detector installed in 2016, which has the same detector specification and similar shielding geometry. This paper describes the shielding configuration, including the cleaning of the material surface, the comparison of calibration data and simulation, the time variation of the background spectra, the sample measurement procedure, and some results of the radioactivity in the selected samples.
△ Less
Submitted 4 December, 2023; v1 submitted 9 August, 2023;
originally announced August 2023.
-
Measurement of cosmic-ray muon spallation products in a xenon-loaded liquid scintillator with KamLAND
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake
, et al. (42 additional authors not shown)
Abstract:
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electroni…
▽ More
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electronics with a high efficiency for detecting muon-induced neutrons. The production yields of different radioisotopes are measured with a combination of delayed coincidence techniques, newly developed muon reconstruction and xenon spallation identification methods. The observed xenon spallation products are consistent with results from the FLUKA and Geant4 simulation codes.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Abundances of uranium and thorium elements in Earth estimated by geoneutrino spectroscopy
Authors:
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura,
T. Mitsui,
H. Miyake,
T. Nakahata
, et al. (43 additional authors not shown)
Abstract:
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been obs…
▽ More
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been observed with the Kamioka Liquid-Scintillator Antineutrino Detector (KamLAND). Those measurements have been improved with more than 18-year observation time, and improvements in detector background levels mainly by an 8-year almost rector-free period now permit spectroscopy with geoneutrinos. Our results yield the first constraint on both uranium and thorium heat contributions. Herein the KamLAND result is consistent with geochemical estimations based on elemental abundances of chondritic meteorites and mantle peridotites. The High-Q model is disfavored at 99.76% C.L. and a fully radiogenic model is excluded at 5.2$σ$ assuming a homogeneous heat producing element distribution in the mantle.
△ Less
Submitted 13 August, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
Search for the Majorana Nature of Neutrinos in the Inverted Mass Ordering Region with KamLAND-Zen
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
S. Hayashida,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura
, et al. (50 additional authors not shown)
Abstract:
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable…
▽ More
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the $0νββ$ decay half-life of $T_{1/2}^{0ν} > 2.3 \times 10^{26}$ yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.
△ Less
Submitted 16 February, 2023; v1 submitted 4 March, 2022;
originally announced March 2022.
-
PICOLON dark matter search project
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kishimoto,
M. Koga,
K. Kotera,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
Y. Yamamoto,
K. Yasuda,
S. Yoshida
Abstract:
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory.…
▽ More
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory. The sensitivity for annual modulating signals and finding dark matter particles will be discussed.
△ Less
Submitted 19 December, 2021;
originally announced December 2021.
-
Dark matter search with high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
Y. Kanemitsu,
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kisimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were le…
▽ More
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were less than 20 ppb and 5.7 $μ$Bq/kg, respectively.
The authors will construct a large volume detector system with high-purity NaI(Tl) crystals. The design and the performance of the prototype detector module will be reported in this article.
△ Less
Submitted 29 June, 2021;
originally announced June 2021.
-
The nylon balloon for xenon loaded liquid scintillator in KamLAND-Zen 800 neutrinoless double-beta decay search experiment
Authors:
KamLAND-Zen collaboration,
:,
Y. Gando,
A. Gando,
T. Hachiya,
S. Hayashida,
K. Hosokawa,
H. Ikeda,
T. Mitsui,
T. Nakada,
S. Obara,
H. Ozaki,
J. Shirai,
K. Ueshima,
H. Watanabe,
S. Abe,
K. Hata,
A. Hayashi,
Y. Honda,
S. Ieki,
K. Inoue,
K. Ishidoshiro,
S. Ishikawa,
Y. Kamei,
K. Kamizawa
, et al. (49 additional authors not shown)
Abstract:
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spa…
▽ More
The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of $^{136}$Xe by using $^{136}$Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and $^{8}$B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of $^{136}$Xe. In this paper, we present an overview of the IB and describe the various steps of its commissioning minimizing the radioactive contaminations, from the material selection, to the fabrication of the balloon and its installation inside the KamLAND detector. Finally, we show the impact of the IB on the KamLAND background as measured by the KamLAND detector itself.
△ Less
Submitted 4 June, 2021; v1 submitted 21 April, 2021;
originally announced April 2021.
-
Development of highly radiopure NaI(Tl) scintillator for PICOLON dark matter search project
Authors:
K. Fushimi,
Y. Kanemitsu,
S. Hirata,
D. Chernyak,
R. Hazama,
H. Ikeda,
K. Imagawa,
H. Ishiura,
H. Ito,
T. Kisimoto,
A. Kozlov,
Y. Takemoto,
K. Yasuda,
H. Ejiri,
K. Hata,
T. Iida,
K. Inoue,
M. Koga,
K. Nakamura,
R. Orito,
T. Shima,
S. Umehara,
S. Yoshida
Abstract:
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was red…
▽ More
The highly radiopure NaI(Tl) was developed to search for particle candidates of dark matter. The optimized methods were combined to reduce various radioactive impurities. The $^{40}$K was effectively reduced by the re-crystallization method. The progenies of the decay chains of uranium and thorium were reduced by appropriate resins. The concentration of natural potassium in NaI(Tl) crystal was reduced down to 20 ppb. Concentrations of alpha-ray emitters were successfully reduced by appropriate selection of resin. The present concentration of thorium series and 226Ra were $1.2 \pm1.4$ $μ$Bq/kg and $13\pm4$ $μ$Bq/kg, respectively. No significant excess in the concentration of $^{210}$Pb was obtained, and the upper limit was 5.7 $μ$Bq/kg at 90% C. L. The achieved level of radiopurity of NaI(Tl) crystals makes construction of a dark matter detector possible.
△ Less
Submitted 20 May, 2021; v1 submitted 3 January, 2021;
originally announced January 2021.
-
Development of a Low-noise Front-end ASIC for CdTe Detectors
Authors:
Tenyo Kawamura,
Tadashi Orita,
Shin'ichiro Takeda,
Shin Watanabe,
Hirokazu Ikeda,
Tadayuki Takahashi
Abstract:
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured withou…
▽ More
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured without connecting the ASIC to any detectors. From the spectroscopy measurements using a CdTe single-sided strip detector, the energy resolution of 1.12 keV (FWHM) is obtained at 13.9 keV, and photons within the energy from 6.4 keV to 122.1 keV are detected. Based on the experimental results, we propose a new low-noise readout architecture making use of a slew-rate limited mode at the shaper followed by a peak detector circuit.
△ Less
Submitted 31 August, 2020;
originally announced September 2020.
-
Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam
Authors:
T. Aoyagi,
Y. Honda,
H. Ikeda,
M. Ikeno,
K. Kawagoe,
T. Kohriki,
T. Kume,
T. Mibe,
K. Namba,
S. Nishimura,
N. Saito,
O. Sasaki,
N. Sato,
Y. Sato,
H. Sendai,
K. Shimomura,
S. Shirabe,
M. Shoji,
T. Suda,
T. Suehara,
T. Takatomi,
M. Tanaka,
J. Tojo,
K. Tsukada,
T. Uchida
, et al. (4 additional authors not shown)
Abstract:
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positr…
▽ More
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.
△ Less
Submitted 7 May, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Compensation of gravity on cold atoms by a linear optical potential
Authors:
Kosuke Shibata,
Hidehiko Ikeda,
Ryota Suzuki,
Takuya Hirano
Abstract:
We demonstrate gravity compensation for an ultracold gas of $^{87}$Rb atoms with a time-averaged optical potential. The position of a far-off-resonance beam is temporally modulated with an acousto-optic deflector to efficiently produce a potential with a linear gradient independent of the atomic magnetic sublevels. We realize compensation of the gravity sag and preparation of a degenerate gas in a…
▽ More
We demonstrate gravity compensation for an ultracold gas of $^{87}$Rb atoms with a time-averaged optical potential. The position of a far-off-resonance beam is temporally modulated with an acousto-optic deflector to efficiently produce a potential with a linear gradient independent of the atomic magnetic sublevels. We realize compensation of the gravity sag and preparation of a degenerate gas in a trap with weak vertical confinement. Optical gravity compensation will provide the opportunity to perform experiments under microgravity in a laboratory and broaden the scope of cold atom research.
△ Less
Submitted 31 July, 2019;
originally announced July 2019.
-
A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment
Authors:
M. Abe,
S. Bae,
G. Beer,
G. Bunce,
H. Choi,
S. Choi,
M. Chung,
W. da Silva,
S. Eidelman,
M. Finger,
Y. Fukao,
T. Fukuyama,
S. Haciomeroglu,
K. Hasegawa,
K. Hayasaka,
N. Hayashizaki,
H. Hisamatsu,
T. Iijima,
H. Iinuma,
K. Inami,
H. Ikeda,
M. Ikeno,
K. Ishida,
T. Itahashi,
M. Iwasaki
, et al. (71 additional authors not shown)
Abstract:
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon…
▽ More
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.
△ Less
Submitted 10 March, 2019; v1 submitted 10 January, 2019;
originally announced January 2019.
-
First Measurements of Beam Backgrounds at SuperKEKB
Authors:
P. M. Lewis,
I. Jaegle,
H. Nakayama,
A. Aloisio,
F. Ameli,
M. Barrett,
A. Beaulieu,
L. Bosisio,
P. Branchini,
T. E. Browder,
A. Budano,
G. Cautero,
C. Cecchi,
Y. -T. Chen,
K. -N. Chu,
D. Cinabro,
P. Cristaudo,
S. de Jong,
R. de Sangro,
G. Finocchiaro,
J. Flanagan,
Y. Funakoshi,
M. Gabriel,
R. Giordano,
D. Giuressi
, et al. (45 additional authors not shown)
Abstract:
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, d…
▽ More
The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.
△ Less
Submitted 5 February, 2018;
originally announced February 2018.
-
Development of Si-CMOS hybrid detectors towards electron tracking based Compton imaging in semiconductor detectors
Authors:
Hiroki Yoneda,
Shinya Saito,
Shin Watanabe,
Hirokazu Ikeda,
Tadayuki Takahashi
Abstract:
Electron tracking based Compton imaging is a key technique to improve the sensitivity of Compton cameras by measuring the initial direction of recoiled electrons. To realize this technique in semiconductor Compton cameras, we propose a new detector concept, Si-CMOS hybrid detector. It is a Si detector bump-bonded to a CMOS readout integrated circuit to obtain electron trajectory images. To acquire…
▽ More
Electron tracking based Compton imaging is a key technique to improve the sensitivity of Compton cameras by measuring the initial direction of recoiled electrons. To realize this technique in semiconductor Compton cameras, we propose a new detector concept, Si-CMOS hybrid detector. It is a Si detector bump-bonded to a CMOS readout integrated circuit to obtain electron trajectory images. To acquire the energy and the event timing, signals from N-side are also read out in this concept. By using an ASIC for the N-side readout, the timing resolution of few us is achieved. In this paper, we present the results of two prototypes with 20 um pitch pixels. The images of the recoiled electron trajectories are obtained with them successfully. The energy resolutions (FWHM) are 4.1 keV (CMOS) and 1.4 keV (N-side) at 59.5 keV. In addition, we confirmed that the initial direction of the electron is determined using the reconstruction algorithm based on the graph theory approach. These results show that Si-CMOS hybrid detectors can be used for electron tracking based Compton imaging.
△ Less
Submitted 5 December, 2017;
originally announced December 2017.
-
Development of a 32-channel ASIC for an X-ray APD Detector onboard the ISS
Authors:
M. Arimoto,
S. Harita,
S. Sugita,
Y. Yatsu,
N. Kawai,
H. Ikeda,
H. Tomida,
N. Isobe,
S. Ueno,
T. Mihara,
M. Serino,
T. Kohmura,
T. Sakamoto,
A. Yoshida,
H. Tsunemi,
S. Hatori,
K. Kume,
T. Hasegawa
Abstract:
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capabl…
▽ More
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 $μ$m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e$^{-}$ + 1.5 e$^{-}$/pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 $^{\circ}$C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing.
△ Less
Submitted 17 November, 2017;
originally announced November 2017.
-
Phase I results with the Large Angle Beamstrahlung Monitor (LABM) with SuperKEKB beams
Authors:
R. Ayad,
G. Bonvicini,
S. Di Carlo,
E. De La Cruz-Burelo,
H. Farhat,
J. Flanagan,
S. Gamez Izaguirre,
R. Gillard,
M. E. Fernandez Villanueva,
H. Ikeda,
K. Kanazawa,
B. O. ElBashir,
P. Podesta,
D. Rodriguez-Perez,
G. Tejeda-Munoz
Abstract:
We report on the SuperKEKB Phase I operations of the Large Angle Beamstrhalung Monitor (LABM). The detector is described and its performance characterized using the synchrotron radiation backgrounds from the last Beam Line magnets. The backgrounds are also used to determine the expected position of the Interaction Point (IP), and the expected background rates during Phase II.
We report on the SuperKEKB Phase I operations of the Large Angle Beamstrhalung Monitor (LABM). The detector is described and its performance characterized using the synchrotron radiation backgrounds from the last Beam Line magnets. The backgrounds are also used to determine the expected position of the Interaction Point (IP), and the expected background rates during Phase II.
△ Less
Submitted 12 October, 2017; v1 submitted 5 September, 2017;
originally announced September 2017.
-
Search for cosmic dark matter by means of ultra high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
R. Hazama,
S. Hirata,
H. Ikeda,
K. Inoue,
K. Imagawa,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
S. Yoshida
Abstract:
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(…
▽ More
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$φ\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(Tl) crystal which contains small amounts of radioactive impurities, $<4$ ppb of $^{nat}$K, 0.3 ppt of Th chain, 58 $μ$Bq/kg of $^{226}$Ra and 30 $μ$Bq/kg of $^{210}$Pb. Future prospects to search for dark matter by means of a large volume and high purity NaI(Tl) scintillator is discussed.
△ Less
Submitted 28 April, 2017;
originally announced May 2017.
-
Radiation tolerance of FPCCD vertex detector for the ILC
Authors:
Shunsuke Murai,
Akimasa Ishikawa,
Tomoyuki Sanuki,
Akiya Miyamoto,
Yasuhiro Sugimoto,
Hisao Sato,
Hirokazu Ikeda,
Hitoshi Yamamoto
Abstract:
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is degraded by radiation damage which makes traps in pixels. We measured charge transfer inefficiency (CTI) of a neutron irradiated FPCCD prototype. We observed a d…
▽ More
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. The vertex detector is located near the interaction point, thus high radiation tolerance is required. Charge transfer efficiency of CCD is degraded by radiation damage which makes traps in pixels. We measured charge transfer inefficiency (CTI) of a neutron irradiated FPCCD prototype. We observed a degradation of CTI compared with non-irradiated CCD. To improve the CTI of irradiated CCD, we performed the fat-zero charge injection to fill the traps. In this paper, we report a status of CTI improvement.
△ Less
Submitted 16 March, 2017;
originally announced March 2017.
-
High purity NaI(Tl) scintillator to search for dark matter
Authors:
Ken-Ichi Fushimi,
Hiroyasu Ejiri,
Ryuta Hazama,
Haruo Ikeda,
Kunio Inoue,
Kyoshiro Imagawa,
Gakuji Kanzaki,
Alexandre Kozlov,
Reiko Orito,
Tatsushi Shima,
Yasuhiro Takemoto,
Yuri Teraoka,
Saori Umehara,
Sei Yoshida
Abstract:
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powde…
▽ More
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of $^{226}$Ra was reduced less than 100 $μ$Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of $^{210}$Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30 $μ$Bq/kg. The expected sensitivity to cosmic dark matter by using 250 kg of the high purity and large volume NaI(Tl) scintillator (PICO-LON; Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) is 7$\times$10$^{-45}$ cm$^{2}$ for 50 GeV$/c^{2}$ WIMPs.
△ Less
Submitted 16 May, 2016;
originally announced May 2016.
-
Particle identification performance of the prototype Aerogel RICH counter for the Belle II experiment
Authors:
S. Iwata,
I. Adachi,
K. Hara,
T. Iijima,
H. Ikeda,
H. Kakuno,
H. Kawai,
T. Kawasaki,
S. Korpar,
P. Krizan,
T. Kumita,
S. Nishida,
S. Ogawa,
R. Pestotnik,
L. Šantelj,
A. Seljak,
M. Tabata,
E. Tahirović,
Y. Yusa
Abstract:
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed t…
▽ More
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed that the HAPD provides high efficiency for single-photon detection even after exposure to neutron and gamma-ray radiation that exceeds the levels expected in the 10-year Belle II operation. In order to confirm the basic performance of the ARICH counter system, we carried out a beam test at the DESY using a prototype of the ARICH counter with six HAPD modules. The results are in agreement with our expectations and confirm the suitability of the ARICH counter for the Belle II experiment. Based on the in-beam performance of the device, we expect that the identification efficiency at 3.5 GeV/c is 97.4% and 4.9% for pions and kaons, respectively. This paper summarizes the development of the HAPD for the ARICH and the evaluation of the performance of the prototype ARICH counter built with the final design components.
△ Less
Submitted 8 March, 2016;
originally announced March 2016.
-
Recent status of FPCCD vertex detector R&D
Authors:
S. Murai,
A. Ishikawa,
T. Sanuki,
A. Miyamoto,
Y. Sugimoto,
C. Constantino,
H. Sato,
H. Ikeda,
Y. Hitoshi
Abstract:
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve radiation tolerance. In this paper, we report on the status of neutron radiation tests, on a cooling system using two-phase CO2 with a gas compressor for circulation, a…
▽ More
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve radiation tolerance. In this paper, we report on the status of neutron radiation tests, on a cooling system using two-phase CO2 with a gas compressor for circulation, and on the mechanical structure of the FPCCD ladders.
△ Less
Submitted 8 March, 2016; v1 submitted 29 February, 2016;
originally announced March 2016.
-
Dark matter search project PICO-LON
Authors:
K. Fushimi,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
G. Kanzaki,
A. Kozlov,
R. Orito,
T. Shima,
Y. Takemoto,
Y. Teraoka,
S. Umehara,
K. Yasuda,
S. Yoshida
Abstract:
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respect…
▽ More
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $μ$Bq/kg and 1.5$\pm$1.9 $μ$Bq/kg, respectively. It should be remarked that the concentration of $^{210}$Pb, which is crucial for the sensitivity to dark matter, was reduced to 24$\pm$2 $μ$Bq/kg. The total background rate at 10 keVee was as low as 8 keV$^{-1}$kg$^{-1}$day$^{-1}$, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed.
△ Less
Submitted 14 December, 2015;
originally announced December 2015.
-
Search for double-beta decay of 136Xe to excited states of 136Ba with the KamLAND-Zen experiment
Authors:
KamLAND-Zen Collaboration,
:,
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
M. Otani,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana
, et al. (21 additional authors not shown)
Abstract:
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all…
▽ More
A search for double-beta decays of 136Xe to excited states of 136Ba has been performed with the first phase data set of the KamLAND-Zen experiment. The 0+1, 2+1 and 2+2 transitions of 0ν\{beta}\{beta} decay were evaluated in an exposure of 89.5kg-yr of 136Xe, while the same transitions of 2ν\{beta}\{beta} decay were evaluated in an exposure of 61.8kg-yr. No excess over background was found for all decay modes. The lower half-life limits of the 2+1 state transitions of 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay were improved to T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 4.6\times10^23 yr (90% C.L.), respectively. We report on the first experimental lower half-life limits for the transitions to the 0+1 state of 136Xe for 0ν\{beta}\{beta} and 2ν\{beta}\{beta} decay. They are T (0ν, 0+ \rightarrow 0+) > 2.4\times10^25 yr and T(2ν, 0+ \rightarrow 0+) > 8.3\times10^23 yr (90% C.L.). The transitions to the 2+2 states are also evaluated for the first time to be T(0ν, 0+ \rightarrow 2+) > 2.6\times10^25 yr and T(2ν, 0+ \rightarrow 2+) > 9.0\times10^23 yr (90% C.L.). These results are compared to recent theoretical predictions.
△ Less
Submitted 8 December, 2015; v1 submitted 12 September, 2015;
originally announced September 2015.
-
Development FD-SOI MOSFET amplifiers for integrated read-out circuit of superconducting-tunnel-junction single-photon-detectors
Authors:
Kenji Kiuchi,
Shinhong Kim,
Yuji Takeuchi,
Kenichi Takemasa,
Kazuki Nagata,
Kota Kasahara,
Koya Moriuchi,
Ren Senzaki,
Shunsuke Yagi,
Hirokazu Ikeda,
Shuji Matsuura,
Takehiko Wada,
Hirokazu Ishino,
Atsuko Kibayashi,
Hiromi Sato,
Satoru Mima,
Takuo Yoshida,
Ryuta Hirose,
Yukihiro Kato,
Masasi Hazumi,
Yasuo Arai,
Ikuo Kurachi,
Erik Ramgerg,
Mark Kozlovsky,
Paul Rubinov
, et al. (6 additional authors not shown)
Abstract:
We proposed a new high resolution single photon infrared spectrometer for search for radiative decay of cosmic neutrino background(C$ν$B). The superconducting-tunnel-junctions(STJs) are used as a single photoncounting device. Each STJ consists of Nb/Al/Al${}_{\mathrm{x}}$O${}_{\mathrm{y}}$/Al/Nb layers and their thicknesses are optimized for the operation temperature at 370 mK cooled by a…
▽ More
We proposed a new high resolution single photon infrared spectrometer for search for radiative decay of cosmic neutrino background(C$ν$B). The superconducting-tunnel-junctions(STJs) are used as a single photoncounting device. Each STJ consists of Nb/Al/Al${}_{\mathrm{x}}$O${}_{\mathrm{y}}$/Al/Nb layers and their thicknesses are optimized for the operation temperature at 370 mK cooled by a ${}^{3}$He sorption refrigerator. Our STJs achieved the leak current 250 pA and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio(S/N). FD-SOI MOSFETs can be operated at cryogenic temperature of 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a non linear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors are 0.4 mV and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp required to have a fast response(GBW$\geq$100 MHz) and it must have low power dissipation as compared to the cooling power of refrigerator.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
Authors:
K. Asakura,
A. Gando,
Y. Gando,
T. Hachiya,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
T. Ishikawa,
S. Ishio,
M. Koga,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
S. Obara,
T. Oura,
I. Shimizu,
Y. Shirahata,
J. Shirai,
A. Suzuki,
H. Tachibana,
K. Tamae,
K. Ueshima,
H. Watanabe
, et al. (22 additional authors not shown)
Abstract:
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta d…
▽ More
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta decay on free hydrogen. This is the golden channel for liquid scintillator detectors because the coincidence signature allows for significant reductions in background signals. We find that the kiloton-scale liquid scintillator detector KamLAND can detect these pre-supernova neutrinos from a star with a mass of $25~M_{\sun}$ at a distance less than 690~pc with 3$σ$ significance before the supernova. This limit is dependent on the neutrino mass ordering and background levels. KamLAND takes data continuously and can provide a supernova alert to the community.
△ Less
Submitted 22 January, 2016; v1 submitted 3 June, 2015;
originally announced June 2015.
-
KamLAND-PICO project to search for cosmic dark matter
Authors:
K. Fushimi,
Y. Awatani,
H. Ejiri,
R. Hazama,
H. Ikeda,
K. Imagawa,
K. Inoue,
A. Kozlov,
R. Orito,
T. Shima,
R. Sugawaraand K. Yasuda
Abstract:
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that th…
▽ More
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that the concentration of $^{210}$Pb which was difficult to reduce reached to the high purity as $58\pm26$ $μ$Bq/kg.
△ Less
Submitted 14 July, 2014;
originally announced July 2014.
-
A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
Authors:
T. I. Banks,
S. J. Freedman,
J. Wallig,
N. Ybarrolaza,
A. Gando,
Y. Gando,
H. Ikeda,
K. Inoue,
Y. Kishimoto,
M. Koga,
T. Mitsui,
K. Nakamura,
I. Shimizu,
J. Shirai,
A. Suzuki,
Y. Takemoto,
K. Tamae,
K. Ueshima,
H. Watanabe,
B. D. Xu,
H. Yoshida,
S. Yoshida,
A. Kozlov,
C. Grant,
G. Keefer
, et al. (32 additional authors not shown)
Abstract:
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. A…
▽ More
We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. An infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable's motion, and the system was controlled via a graphical user interface.
△ Less
Submitted 11 February, 2015; v1 submitted 1 July, 2014;
originally announced July 2014.
-
Circularly polarized light detector based on ferromagnet/semiconductor junctions
Authors:
H. Ikeda,
N. Nishizawa,
K. Nishibayashi,
H. Munekata
Abstract:
Helicity-dependent photocurrent delta-I has been detected successfully under experimental configuration that a circularly polarized light beam is impinged with a right angle on a cleaved sidewall of the Fe/x-AlOx/GaAs-based n-i-p double-heterostructure. The photocurrent delta-I has showed a well-defined hysteresis loop which resembles that of the magnetization of the in-plane magnetized Fe layer i…
▽ More
Helicity-dependent photocurrent delta-I has been detected successfully under experimental configuration that a circularly polarized light beam is impinged with a right angle on a cleaved sidewall of the Fe/x-AlOx/GaAs-based n-i-p double-heterostructure. The photocurrent delta-I has showed a well-defined hysteresis loop which resembles that of the magnetization of the in-plane magnetized Fe layer in the devices. The value of delta-I has been |delta-I|~0.2 nA at 5 K under the remnant magnetization state. Study on temperature dependence of the relative delta-I value at H = 0 has revealed that it is maximized at temperatures 125 - 150 K, and is still measurable at room temperature.
△ Less
Submitted 16 April, 2014;
originally announced April 2014.
-
Laboratory Studies on the Removal of Radon-Born Lead from KamLAND's Organic Liquid Scintillator
Authors:
G. Keefer,
C. Grant,
A. Piepke,
T. Ebihara,
H. Ikeda,
Y. Kishimoto,
Y. Kibe,
Y. Koseki,
M. Ogawa,
J. Shirai,
S. Takeuchi,
C. Mauger,
C. Zhang,
G. Schweitzer,
B. E. Berger,
S. Dazeley,
M. P. Decowski,
J. A. Detwiler,
Z. Djurcic,
D. A. Dwyer,
Y. Efremenko,
S. Enomoto,
S. J. Freedman,
B. K. Fujikawa,
K. Furuno
, et al. (43 additional authors not shown)
Abstract:
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was ide…
▽ More
The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.
△ Less
Submitted 3 December, 2013;
originally announced December 2013.
-
CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND
Authors:
A. Gando,
Y. Gando,
S. Hayashida,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
H. Ishikawa,
M. Koga,
R. Matsuda,
S. Matsuda,
T. Mitsui,
D. Motoki,
K. Nakamura,
Y. Oki,
M. Otani,
I. Shimizu,
J. Shirai,
F. Suekane,
A. Suzuki,
Y. Takemoto,
K. Tamae,
K. Ueshima,
H. Watanabe,
B. D. Xu,
S. Yamada
, et al. (41 additional authors not shown)
Abstract:
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutr…
▽ More
The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.
△ Less
Submitted 13 April, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.
-
Single event effect characterization of the mixed-signal ASIC developed for CCD camera in space use
Authors:
Hiroshi Nakajima,
Mari Fujikawa,
Hideki Mori,
Hiroaki Kan,
Shutaro Ueda,
Hiroko Kosugi,
Naohisa Anabuki,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We present the single event effect (SEE) tolerance of a mixed-signal application-specific integrated circuit (ASIC) developed for a charge-coupled device camera onboard a future X-ray astronomical mission. We adopted proton and heavy ion beams at HIMAC/NIRS in Japan. The particles with high linear energy transfer (LET) of 57.9 MeV cm^{2}/mg is used to measure the single event latch-up (SEL) tolera…
▽ More
We present the single event effect (SEE) tolerance of a mixed-signal application-specific integrated circuit (ASIC) developed for a charge-coupled device camera onboard a future X-ray astronomical mission. We adopted proton and heavy ion beams at HIMAC/NIRS in Japan. The particles with high linear energy transfer (LET) of 57.9 MeV cm^{2}/mg is used to measure the single event latch-up (SEL) tolerance, which results in a sufficiently low cross-section of sigma_{SEL} < 4.2x10^{-11} cm^{2}/(IonxASIC). The single event upset (SEU) tolerance is estimated with various kinds of species with wide range of energy. Taking into account that a part of the protons creates recoiled heavy ions that has higher LET than that of the incident protons, we derived the probability of SEU event as a function of LET. Then the SEE event rate in a low-earth orbit is estimated considering a simulation result of LET spectrum. SEL rate is below once per 49 years, which satisfies the required latch-up tolerance. The upper limit of the SEU rate is derived to be 1.3x10^{-3}events/sec. Although the SEU events cannot be distinguished from the signals of X-ray photons from astronomical objects, the derived SEU rate is below 1.3% of expected non-X-ray background rate of the detector and hence these events should not be a major component of the instrumental background.
△ Less
Submitted 11 July, 2013;
originally announced July 2013.
-
Spin-Echo-Based Magnetometry with Spinor Bose-Einstein Condensates
Authors:
Yujiro Eto,
Hayato Ikeda,
Hirosuke Suzuki,
Sho Hasegawa,
Yasushi Tomiyama,
Sawako Sekine,
Mark Sadgrove,
Takuya Hirano
Abstract:
We demonstrate detection of a weak alternate-current magnetic field by application of the spin echo technique to F = 2 Bose-Einstein condensates. A magnetic field sensitivity of 12 pT/Hz^1/2 is attained with the atom number of 5*10^3 at spatial resolution of 99 μm^2. Our observations indicate magnetic field fluctuations synchronous with the power supply line frequency. We show that this noise is g…
▽ More
We demonstrate detection of a weak alternate-current magnetic field by application of the spin echo technique to F = 2 Bose-Einstein condensates. A magnetic field sensitivity of 12 pT/Hz^1/2 is attained with the atom number of 5*10^3 at spatial resolution of 99 μm^2. Our observations indicate magnetic field fluctuations synchronous with the power supply line frequency. We show that this noise is greatly suppressed by application of a reverse phase magnetic field. Our technique is useful in order to create a stable magnetic field environment, which is an important requirement for atomic experiments which require a weak bias magnetic field.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.
-
R&D Status of FPCCD Vertex Detector for ILD
Authors:
Yasuhiro Sugimoto,
Hirokazu Ikeda,
Daisuke Kamai,
Eriko Kato,
Akiya Miyamoto,
Hisao Sato,
Hitoshi Yamamoto
Abstract:
Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). A vertex detector system for the International Large Detector (ILD) using FPCCD sensors has been designed. We report on the R&D status of FPCCD sensors, as well as the vertex detector design for ILD.
Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). A vertex detector system for the International Large Detector (ILD) using FPCCD sensors has been designed. We report on the R&D status of FPCCD sensors, as well as the vertex detector design for ILD.
△ Less
Submitted 27 February, 2012;
originally announced February 2012.
-
Developement of readout ASIC for FPCCD vertex detector
Authors:
Eriko Kato,
Hisao Sato,
Hirokazu Ikeda,
Yasuhiro Sugimoto,
Kennosuke Itagaki,
Tomoyuki Saito,
Akiya Miyamoto,
Yosuke Takubo,
Hitoshi Yamamoto
Abstract:
One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been developed. In this paper we will report on the performance of latest developed readout ASIC prototype as well as the outline of the design strategy for the next ASIC pro…
▽ More
One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been developed. In this paper we will report on the performance of latest developed readout ASIC prototype as well as the outline of the design strategy for the next ASIC prototype.
△ Less
Submitted 14 February, 2012;
originally announced February 2012.
-
Development of the analog ASIC for multi-channel readout X-ray CCD camera
Authors:
Hiroshi Nakajima,
Daisuke Matsuura,
Toshihiro Idehara,
Naohisa Anabuki,
Hiroshi Tsunemi,
John P. Doty,
Hirokazu Ikeda,
Haruyoshi Katayama,
Hisashi Kitamura,
Yukio Uchihori
Abstract:
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that…
▽ More
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCDcamera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of =<30 uV at the pixel rate below 100 kHz. The power consumption is sufficiently low of about 150 mW/chip. The input signal range of 720 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 keV). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using 60Co and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2x10^8 Ion/cm2 resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm^2/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit.
△ Less
Submitted 11 February, 2011;
originally announced February 2011.
-
R&D Status and Plan for FPCCD VTX
Authors:
Yasuhiro Sugimoto,
Hirokazu Ikeda,
Kennosuke Itagaki,
Akiya Miyamoto,
Yousuke Takubo,
Hitoshi Yamamoto
Abstract:
Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and the R&D plan for the sensors and the cooling system.
Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and the R&D plan for the sensors and the cooling system.
△ Less
Submitted 15 July, 2010;
originally announced July 2010.
-
Irradiation test on FD-SOI Readout ASIC of Pair-monitor
Authors:
Yutaro Sato,
Hirokazu Ikeda,
Akiya Miyamoto,
Yosuke Takubo,
Toshiaki Tauchi,
Hitoshi Yamamoto
Abstract:
We fabricated a readout ASIC with the fully depleted silicon-on-insulator (FD-SOI) technology for the pair-monitor. The pair-monitor is a silicon pixel device that measures the beam profile of the international linear collider. It utilizes the directional distribution of a large number of electron-positron pairs created by collision of bunches, and is required to tolerate radiation dose of about a…
▽ More
We fabricated a readout ASIC with the fully depleted silicon-on-insulator (FD-SOI) technology for the pair-monitor. The pair-monitor is a silicon pixel device that measures the beam profile of the international linear collider. It utilizes the directional distribution of a large number of electron-positron pairs created by collision of bunches, and is required to tolerate radiation dose of about a few Mrad/year. The irradiation might cause the buried oxide layer of SOI to accumulate charges which interfere with intended functions. We thus performed extensive irradiation tests on the prototype ASIC, and the results are described in this paper.
△ Less
Submitted 22 June, 2010;
originally announced June 2010.
-
R&D status of FPCCD VTX
Authors:
Yasuhiro Sugimoto,
Hirokazu Ikeda,
Akiya Miyamoto,
Tadashi Nagamine,
Yousuke Takubo,
Hitoshi Yamamoto
Abstract:
As a candidate of the vertex detector for experiments at ILC, fully depleted fine pixel CCDs (FPCCDs) are under development. We describe the basic concept of the FPCCD and report on preliminary results of the performance study of the first prototype FPCCD sensors.
As a candidate of the vertex detector for experiments at ILC, fully depleted fine pixel CCDs (FPCCDs) are under development. We describe the basic concept of the FPCCD and report on preliminary results of the performance study of the first prototype FPCCD sensors.
△ Less
Submitted 12 February, 2009;
originally announced February 2009.
-
Development of Pair Monitor
Authors:
Yosuke Takubo,
Hirokazu Ikeda,
Kazutoshi Ito,
Akiya Miyamoto,
Tadashi Nagamine,
Rei Sasaki,
Toshiaki Tauchi,
Yutaro Sato,
Hiroshi Yamamoto
Abstract:
The pair monitor is a beam profile monitor at interaction point (IP) for the international linear collider (ILC). We have designed and developed the pair monitor as a silicon pixel sensor which is located at about 400 cm from IP. As the first step to develop the pair monitor, the readout ASIC was developed. In this paper, test results of the readout ASIC and the future plan are reported.
The pair monitor is a beam profile monitor at interaction point (IP) for the international linear collider (ILC). We have designed and developed the pair monitor as a silicon pixel sensor which is located at about 400 cm from IP. As the first step to develop the pair monitor, the readout ASIC was developed. In this paper, test results of the readout ASIC and the future plan are reported.
△ Less
Submitted 22 January, 2009;
originally announced January 2009.
-
Development of Readout ASIC for FPCCD Vertex Detector
Authors:
Yosuke Takubo,
Hirokazu Ikeda,
Kennosuke Itagaki,
Akiya Miyamoto,
Tadashi Nagamine,
Yasuhiro Sugimoto,
Hitoshi Yamamoto
Abstract:
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout ASIC was confirmed to work correctly at slow readout speed (1.5 Mpix/sec). In this letter, we describe the status of the performance study for the readout ASIC…
▽ More
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout ASIC was confirmed to work correctly at slow readout speed (1.5 Mpix/sec). In this letter, we describe the status of the performance study for the readout ASIC.
△ Less
Submitted 22 January, 2009;
originally announced January 2009.
-
Compensation of the Crossing Angle with Crab Cavities at KEKB
Authors:
T. Abe,
K. Akai,
M. Akemoto,
A. Akiyama,
M. Arinaga,
K. Ebihara,
K. Egawa,
A. Enomoto,
J. Flanagan,
S. Fukuda,
H. Fukuma,
Y. Funakoshi,
K. Furukawa,
T. Furuya,
K. Hara,
T. Higo,
S. Hiramatsu,
H. Hisamatsu,
H. Honma,
T. Honma,
K. Hosoyama,
T. Ieiri,
N. Iida,
H. Ikeda,
M. Ikeda
, et al. (90 additional authors not shown)
Abstract:
Crab cavities have been installed in the KEKB B--Factory rings to compensate the crossing angle at the collision point and thus increase luminosity. The beam operation with crab crossing has been done since February 2007. This is the first experience with such cavities in colliders or storage rings. The crab cavities have been working without serious issues. While higher specific luminosity than…
▽ More
Crab cavities have been installed in the KEKB B--Factory rings to compensate the crossing angle at the collision point and thus increase luminosity. The beam operation with crab crossing has been done since February 2007. This is the first experience with such cavities in colliders or storage rings. The crab cavities have been working without serious issues. While higher specific luminosity than the geometrical gain has been achieved, further study is necessary and under way to reach the prediction of simulation.
△ Less
Submitted 21 June, 2007;
originally announced June 2007.
-
Negative Momentum Compaction at KEKB
Authors:
H. Ikeda,
J. W. Flanagan,
H. Fukuma,
S. Hiramatsu,
T. Ieiri,
H. Koiso,
T. Mimashi,
T. Mitsuhashi
Abstract:
KEKB is a high luminosity e+e- collider for studying B mesons and has achieved the design luminosity of 1034cm-2s-1 in 2003. In order to get higher luminosity, we tested negative momentum compaction optics in the summer of 2003. We measured the bunch length using three methods at 0.7mA to 1.17mA bunch current and confirmed the length was shortened with the negative momentum compaction optics.
KEKB is a high luminosity e+e- collider for studying B mesons and has achieved the design luminosity of 1034cm-2s-1 in 2003. In order to get higher luminosity, we tested negative momentum compaction optics in the summer of 2003. We measured the bunch length using three methods at 0.7mA to 1.17mA bunch current and confirmed the length was shortened with the negative momentum compaction optics.
△ Less
Submitted 28 January, 2004;
originally announced January 2004.