-
Modal analysis of blood flows in saccular aneurysms
Authors:
Thien-Tam Nguyen,
Davina Kasperski,
Phat Kim Huynh,
Trung Quoc Le,
Trung Bao Le
Abstract:
Currently, it is challenging to investigate aneurismal hemodynamics based on current in-vivo data such as Magnetic Resonance Imaging or Computed Tomography due to the limitations in both spatial and temporal resolutions. In this work, we investigate the use of modal analysis at various resolutions to examine its usefulness for analyzing blood flows in brain aneurysms. Two variants of Dynamic Mode…
▽ More
Currently, it is challenging to investigate aneurismal hemodynamics based on current in-vivo data such as Magnetic Resonance Imaging or Computed Tomography due to the limitations in both spatial and temporal resolutions. In this work, we investigate the use of modal analysis at various resolutions to examine its usefulness for analyzing blood flows in brain aneurysms. Two variants of Dynamic Mode Decomposition (DMD): (i) Hankel-DMD; and (ii) Optimized-DMD, are used to extract the time-dependent dynamics of blood flows during one cardiac cycle. First, high-resolution hemodynamic data in patient-specific aneurysms are obtained using Computational Fluid Dynamics. Second, the dynamics modes, along with their spatial amplitudes and temporal magnitudes are calculated using the DMD analysis. Third, an examination of DMD analyses using a range of spatial and temporal resolutions of hemodynamic data to validate the applicability of DMD for low-resolution data, similar to ones in clinical practices. Our results show that DMD is able to characterize the inflow jet dynamics by separating large-scale structures and flow instabilities even at low spatial and temporal resolutions. Its robustness in quantifying the flow dynamics using the energy spectrum is demonstrated across different resolutions in all aneurysms in our study population. Our work indicates that DMD can be used for analyzing blood flow patterns of brain aneurysms and is a promising tool to be explored in in-vivo.
△ Less
Submitted 15 October, 2024;
originally announced October 2024.
-
Real-Time Magnetic Tracking and Diagnosis of COVID-19 via Machine Learning
Authors:
Dang Nguyen,
Phat K. Huynh,
Vinh Duc An Bui,
Kee Young Hwang,
Nityanand Jain,
Chau Nguyen,
Le Huu Nhat Minh,
Le Van Truong,
Xuan Thanh Nguyen,
Dinh Hoang Nguyen,
Le Tien Dung,
Trung Q. Le,
Manh-Huong Phan
Abstract:
The COVID-19 pandemic underscored the importance of reliable, noninvasive diagnostic tools for robust public health interventions. In this work, we fused magnetic respiratory sensing technology (MRST) with machine learning (ML) to create a diagnostic platform for real-time tracking and diagnosis of COVID-19 and other respiratory diseases. The MRST precisely captures breathing patterns through thre…
▽ More
The COVID-19 pandemic underscored the importance of reliable, noninvasive diagnostic tools for robust public health interventions. In this work, we fused magnetic respiratory sensing technology (MRST) with machine learning (ML) to create a diagnostic platform for real-time tracking and diagnosis of COVID-19 and other respiratory diseases. The MRST precisely captures breathing patterns through three specific breath testing protocols: normal breath, holding breath, and deep breath. We collected breath data from both COVID-19 patients and healthy subjects in Vietnam using this platform, which then served to train and validate ML models. Our evaluation encompassed multiple ML algorithms, including support vector machines and deep learning models, assessing their ability to diagnose COVID-19. Our multi-model validation methodology ensures a thorough comparison and grants the adaptability to select the most optimal model, striking a balance between diagnostic precision with model interpretability. The findings highlight the exceptional potential of our diagnostic tool in pinpointing respiratory anomalies, achieving over 90% accuracy. This innovative sensor technology can be seamlessly integrated into healthcare settings for patient monitoring, marking a significant enhancement for the healthcare infrastructure.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
Multifractality in Surface Potential for Cancer Diagnosis
Authors:
Phat K. Huynh,
Dang Nguyen,
Grace Binder,
Sharad Ambardar,
Trung Q. Le,
Dmitri V. Voronine
Abstract:
Recent advances in high-resolution biomedical imaging focusing on morphological, electrical, and biochemical properties of cells and tissues, scaling from cell clusters down to the molecular level, have improved cancer diagnosis. Multiscale imaging revealed high complexity that requires advanced data processing methods of multifractal analysis. We performed label-free multiscale imaging of surface…
▽ More
Recent advances in high-resolution biomedical imaging focusing on morphological, electrical, and biochemical properties of cells and tissues, scaling from cell clusters down to the molecular level, have improved cancer diagnosis. Multiscale imaging revealed high complexity that requires advanced data processing methods of multifractal analysis. We performed label-free multiscale imaging of surface potential variations in human ovarian and breast cancer cells using Kelvin probe force microscopy (KPFM). An improvement in the differentiation between normal and cancerous cells of for multifractal analysis using adaptive versus median threshold for image binarization was demonstrated. The results reveal the potential of using multifractality as a new biomarker for cancer diagnosis. Furthermore, the surface potential imaging can be used in combination with morphological imaging for cancer diagnosis.
△ Less
Submitted 20 April, 2023;
originally announced April 2023.
-
Hybrid electrostatic-atomic accelerometer for future space gravity missions
Authors:
Nassim Zahzam,
Bruno Christophe,
Vincent Lebat,
Emilie Hardy,
Phuong-Anh Huynh,
Noémie Marquet,
Cédric Blanchard,
Yannick Bidel,
Alexandre Bresson,
Petro Abrykosov,
Thomas Gruber,
Roland Pail,
Ilias Daras,
Olivier Carraz
Abstract:
Long term observation of temporal Earth's gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main path to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic a…
▽ More
Long term observation of temporal Earth's gravity field with enhanced temporal and spatial resolution is a major objective for future satellite gravity missions. Improving the performance of the accelerometers present in such missions is one of the main path to explore. In this context, we propose to study an original concept of a hybrid accelerometer associating a state-of-the-art electrostatic accelerometer (EA) and a promising quantum sensor based on cold atom interferometry. To assess the performance potential of such instrument, numerical simulations have been performed to determine its impact in term of gravity field retrieval. Taking advantage of the long term stability of the cold atom interferometer (CAI), it has been shown that the reduced drift of the hybrid sensor could lead to improved gravity field retrieval. Nevertheless this gain vanishes once temporal variations of the gravity field and related aliasing effects are taken into account. Improved de-aliasing models or some specific satellite constellations are then required to maximize the impact of the accelerometer performance gain. To evaluate the achievable acceleration performance in orbit, a numerical simulator of the hybrid accelerometer has been developed and preliminary results are given. The instrument simulator has been in part validated by reproducing the performance achieved with a hybrid lab prototype operating on ground. The problematic of satellite rotation impact on the CAI has been also investigated both with instrument performance simulations and experimental demonstrations. It has been shown that the proposed configuration, where the EA's proof-mass acts as the reference mirror for the CAI, seems a promising approach to allow the mitigation of satellite rotation. A preliminary design has been elaborated along with a preliminary error, mass, volume and electrical power consumption budget.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
MICROSCOPE: systematic errors
Authors:
Manuel Rodrigues,
Pierre Touboul1,
Gilles Metris,
Alain Robert,
Oceane Dhuicque,
Joel Berge,
Yves Andre,
Damien Boulanger,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Vincent Lebat,
Francoise Liorzou,
Benjamin Pouilloux,
Pascal Prieur,
Serge Reynaud,
Patrizia Torresi
Abstract:
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Syste…
▽ More
The MICROSCOPE mission aims to test the Weak Equivalence Principle (WEP) in orbit with an unprecedented precision of 10$^{-15}$ on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
MICROSCOPE instrument in-flight characterization
Authors:
Ratana Chhun,
Emilie Hardy,
Manuel Rodrigues,
Pierre Touboul,
Gilles Métris,
Damien Boulanger,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Pierre-Yves Guidotti,
Phuong-Anh Huynh,
Vincent Lebat,
Françoise Liorzou,
Alain Robert
Abstract:
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subseq…
▽ More
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
△ Less
Submitted 12 May, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
MICROSCOPE instrument description and validation
Authors:
Françoise Liorzou,
Pierre Touboul,
Manuel Rodrigues,
Gilles Métris,
Yves André,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Pascale Danto,
Bernard Foulon,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Meike List,
Frank Löffler,
Benny Rievers,
Alain Robert,
Hanns Selig
Abstract:
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very a…
▽ More
Dedicated accelerometers have been developed for the MICROSCOPE mission taking into account the specific range of acceleration to be measured on board the satellite. Considering one micro-g and even less as the full range of the instrument, leads to a customized concept and a high performance electronics for the sensing and servo-actuations of the accelerometer test-masses. In addition to a very accurate geometrical sensor core, a high performance electronics architecture provides the measurement of the weak electrostatic forces and torques applied to the test-masses. A set of capacitive sensors delivers the position and the attitude of the test-mass with respect to a very steady gold coated cage made in silica. The voltages applied on the electrodes surrounding each test-mass are finely controlled to generate the adequate electrical field and so the electrostatic pressures on the test-mass. This field maintains the test-mass motionless with respect to the instrument structure. Digital control laws are implemented in order to enable instrument operation flexibility and a weak position sensor noise. These electronics provide both the scientific data for MICROSCOPE's test of General Relativity and the data for the satellite drag-free and attitude control system (DFACS).
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Françoise Liorzou,
Meike List,
Isabelle Panet,
Sandrine Pires
, et al. (9 additional authors not shown)
Abstract:
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different co…
▽ More
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of Eötvös parameter $δ(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$σ$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$σ$ uncertainties leads to a current limit on $δ$ of about $1.3\times{}10^{-14}$.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.