-
Photomultiplier Requirements and Pre-Calibration for the SABRE South Liquid Scintillator Veto
Authors:
L. J. Milligan,
P. Urquijo,
E. Barberio,
V. U. Bashu,
L. J. Bignell,
I. Bolognino,
S. S. Chhun,
F. Dastgiri,
T. Fruth,
G. Fu,
G. C. Hill,
Y. Hua,
R. S. James,
K. Janssens,
S. Kapoor,
G. J. Lane,
K. T. Leaver,
P. McGee,
L. J. McKie,
J. McKenzie,
P. C. McNamara,
W. J. D. Melbourne,
M. Mews,
W. H. Ng,
K. J. Rule
, et al. (10 additional authors not shown)
Abstract:
We present a study of the oil-proof base Hamamatsu R5912 photomultiplier tubes that will be used in the SABRE South linear-alkylbenzene liquid scintillator veto. SABRE South is a dark matter direct detection experiment at the Stawell Underground Physics Laboratory, aiming to test the DAMA/LIBRA dark matter annual modulation signal. We discuss the requirements of the liquid scintillator system and…
▽ More
We present a study of the oil-proof base Hamamatsu R5912 photomultiplier tubes that will be used in the SABRE South linear-alkylbenzene liquid scintillator veto. SABRE South is a dark matter direct detection experiment at the Stawell Underground Physics Laboratory, aiming to test the DAMA/LIBRA dark matter annual modulation signal. We discuss the requirements of the liquid scintillator system and its photomultipliers, outline the methods and analysis used for the characterisation measurements, and results from initial tests. We discuss the impact of these measurements on the performance of the active veto system and explore analysis methods to allow for low threshold operation. Finally, we include results from a small scale liquid scintillator detector prototype used to assess the future performance of pulse shape discrimination in the liquid scintillator veto, and how well accommodated it is by the R5912 PMTs.
△ Less
Submitted 19 May, 2025; v1 submitted 15 May, 2025;
originally announced May 2025.
-
Cerebral blood flow monitoring using a deep learning implementation of the two-layer DCS analytical model with a 512x512 SPAD array
Authors:
Mingliang Pan,
Chenxu Li,
Yuanzhe Zhang,
Alan Mollins,
Quan Wang,
Ahmet T. Erdogan,
Yuanyuan Hua,
Zhenya Zang,
Neil Finlayson,
Robert K. Henderson,
David Day-Uei Li
Abstract:
Diffuse correlation spectroscopy (DCS) analyzes the autocorrelation function of photons scattered by red blood cells, enabling non-invasive, continuous measurement of deep tissue blood flow at the bedside. Multi-layer DCS models (two- and three-layer) enhance cerebral blood flow index (CBFi) sensitivity and mitigate interference from extracerebral tissues. However, these models require multiple pr…
▽ More
Diffuse correlation spectroscopy (DCS) analyzes the autocorrelation function of photons scattered by red blood cells, enabling non-invasive, continuous measurement of deep tissue blood flow at the bedside. Multi-layer DCS models (two- and three-layer) enhance cerebral blood flow index (CBFi) sensitivity and mitigate interference from extracerebral tissues. However, these models require multiple predefined parameters and are computationally intensive, making them impractical for real-time bedside monitoring. To address this challenge, we integrate a single-photon avalanche diode (SPAD) array with a deep learning (DL)-based approach trained on data generated by the two-layer analytical model. This method bypasses traditional model fitting, enabling real-time CBFi monitoring while minimizing superficial tissue contamination. We first validate our approach using Monte Carlo-simulated test datasets, demonstrating superior accuracy in relative CBFi estimation (5.8% error vs. 19.1% for conventional fitting) and enhanced CBFi sensitivity (87.1% vs. 55.4%). Additionally, our method effectively isolates shallow blood flow changes and 750-fold faster than single-exponential fitting in a realistic scenario. We further evaluate the system in a healthy adult, achieving real-time CBFi monitoring and pulsatile waveform recovery during a brain activity test using a 512 512 SPAD array sensor. These results highlight the potential of our approach for real-time brain activity monitoring.
△ Less
Submitted 3 May, 2025; v1 submitted 9 April, 2025;
originally announced April 2025.
-
Deep non-invasive cerebral blood flow sensing using diffuse correlation spectroscopy and ATLAS
Authors:
Quan Wang,
Yuanyuan Hua,
Chenxu Li,
Mingliang Pan,
Maciej Wojtkiewicz,
Ahmet T. Erdogan,
Alistair Gorman,
Yuanzhe Zhang,
Neil Finlayson,
Yining Wang,
Robert K. Henderson,
David Uei-Day Li
Abstract:
Cerebral blood flow (CBF) is a crucial indicator of brain function, and its continuous monitoring is critical for diagnosing and treating neurological disorders such as stroke, traumatic brain injury, and neurodegenerative diseases. Diffuse correlation spectroscopy (DCS) is a non-invasive diffuse optical technique to investigate deep tissue microvascular dynamics. However, traditional DCS systems…
▽ More
Cerebral blood flow (CBF) is a crucial indicator of brain function, and its continuous monitoring is critical for diagnosing and treating neurological disorders such as stroke, traumatic brain injury, and neurodegenerative diseases. Diffuse correlation spectroscopy (DCS) is a non-invasive diffuse optical technique to investigate deep tissue microvascular dynamics. However, traditional DCS systems face challenges in real-time applications due to reliance on correlation boards or software autocorrelators for signal acquisition, which limits their practical use. Furthermore, most existing DCS measurements are confined to a source-detector separation, ρ= 20 - 30 mm, with a maximum ρ= 40 mm, potentially reducing cerebral hemodynamics assessment accuracy. To overcome these limitations, we utilized a fully in-house-built 512 x 512 single-photon avalanche diode array (SPAD) called ATLAS, featuring innovative on-chip autocorrelators. The ATLAS-DCS system was evaluated against a commercial correlator board DCS system for liquid phantoms and cuff occlusion studies. Also, we successfully monitored pulsatile blood flow at ρof 50 mm with a high sampling rate of up to 56.3 Hz in a human forehead in vivo. Our system also demonstrated high fidelity in detecting human pulse and identifying behaviour-induced physiological variations from the subject's prefrontal cortex during video gaming. We show that the ATLAS-DCS system outperforms the commonly used APD-based DCS system, achieving more than 571x SNR improvement in a milk-phantom at ρof 20 mm. This DCS on-chip design paves the way for high-speed biological signal measurement in real-time applications by significantly enhancing detection sensitivity and speed.
△ Less
Submitted 21 March, 2025;
originally announced March 2025.
-
Fiber-based Ultra-High Speed Diffuse Speckle Contrast Analysis System for Deep Blood Flow Sensing Using a Large SPAD Camera
Authors:
Quan Wang,
Renzhe Bi,
Songhua Zheng,
Ahmet T. Erdogan,
Yi Qi,
Chenxu Li,
Yuanyuan Hua,
Mingliang Pan,
Yining Wang,
Neil Finlayson,
Malini Olivo,
Robert K. Henderson,
David Uei-Day Li
Abstract:
Diffuse speckle contrast analysis (DSCA), also called speckle contrast optical spectroscopy(SCOS), has emerged as a groundbreaking optical imaging technique for tracking dynamic biological processes, including blood flow and tissue perfusion. Recent advancements in single-photon avalanche diode (SPAD) cameras have unlocked exceptional capabilities in sensitivity, time resolution, and high frame ra…
▽ More
Diffuse speckle contrast analysis (DSCA), also called speckle contrast optical spectroscopy(SCOS), has emerged as a groundbreaking optical imaging technique for tracking dynamic biological processes, including blood flow and tissue perfusion. Recent advancements in single-photon avalanche diode (SPAD) cameras have unlocked exceptional capabilities in sensitivity, time resolution, and high frame rate imaging. Despite this, the application of large-format SPAD arrays in speckle contrast analysis is still relatively uncommon. In this study, we introduce a pioneering use of a large format SPAD camera for DSCA. By harnessing the camera's high temporal resolution and photon detection efficiency, we significantly enhance the accuracy and robustness of speckle contrast measurements. Our experimental results demonstrate the system's remarkable ability to capture rapid temporal variations over a broad field of view, enabling detailed spatiotemporal analysis. Through simulations, phantom experiments, and in vivo studies, we validate the approach's potential for a wide range of biomedical applications, such as cuff occlusion tests and functional tissue monitoring. This work highlights the transformative impact of large SPAD cameras on DSCA, paving the way for new breakthroughs in optical imaging.
△ Less
Submitted 27 February, 2025;
originally announced February 2025.
-
A wireless passive pressure sensor with high sensitivity
Authors:
Baiyun Wang,
Yijia Cheng,
Yujie Hua,
Wenxuan Tang,
Wei E. I. Sha,
Hao Xu,
Kang Wang,
Jundi Hu,
Huaqing Fan,
Huanran Peng,
Gang Shao
Abstract:
A high-sensitivity wireless pressure sensor with active processing structure designed on the dielectric substrate has been present and evaluated in this paper. The sensor configuration has been optimized by computer-aided design to achieve highest sensitivity and maximum working range for a given dimension. With the average sensitivity of 187kHz/kPa, the proposed pressure sensor is equipped with t…
▽ More
A high-sensitivity wireless pressure sensor with active processing structure designed on the dielectric substrate has been present and evaluated in this paper. The sensor configuration has been optimized by computer-aided design to achieve highest sensitivity and maximum working range for a given dimension. With the average sensitivity of 187kHz/kPa, the proposed pressure sensor is equipped with the ability to measure pressure loaded up to 1.5MPa under room temperature. Additionally, a novel simulation method applied on pressure related design is proposed in this article, with the accuracy reaching threefold enhancement, filling the blank of electromagnetic simulation of pressure deformation. Other characteristics of the devices have been investigated and are presented.
△ Less
Submitted 24 November, 2024;
originally announced November 2024.
-
Theory and mitigation of motional eddy current in high-field eddy current shielding
Authors:
Seung-Kyun Lee,
Yihe Hua
Abstract:
Eddy current shielding by a Faraday cage is an effective way to shield alternating-current (AC) magnetic fields in scientific instrumentation. In a strong static magnetic field, however, the eddy current in the conductive shield is subject to the Lorentz force which causes the shield to vibrate. In addition to mechanical issues, such vibration induces motional eddy current in the shield that can d…
▽ More
Eddy current shielding by a Faraday cage is an effective way to shield alternating-current (AC) magnetic fields in scientific instrumentation. In a strong static magnetic field, however, the eddy current in the conductive shield is subject to the Lorentz force which causes the shield to vibrate. In addition to mechanical issues, such vibration induces motional eddy current in the shield that can dominate the original, electromagnetic eddy current to undermine the conductor's shielding capability. In this work we investigate a method to control motional eddy current by making cut-out patterns in the conductor that follow the electromagnetic eddy current image. This effectively limits the surface current of the plate to a single mode and prevents proliferation of uncontrolled motion-induced surface currents that disrupts eddy current shielding. Implications of our results for improved shielding of gradient fields in high-field MRI are discussed.
△ Less
Submitted 6 April, 2024;
originally announced April 2024.
-
Maximum Power and The Corresponding Efficiency for A Carnot-like Thermoelectric Cycle Based on Fluctuation Theorem
Authors:
Yuchao Hua,
Lingai Luo,
Zeng-Yuan Guo
Abstract:
Here, we investigate the maximum power and corresponding efficiency of thermoelectric generators through devising a set of protocols for the isothermal and adiabatic processes of thermoelectricity to build a Carnot-like thermoelectric cycle, with the analysis based on fluctuation theorem (FT). First of all, the Carnot efficiency can be readily obtained for the quasi-static thermoelectric cycle, wi…
▽ More
Here, we investigate the maximum power and corresponding efficiency of thermoelectric generators through devising a set of protocols for the isothermal and adiabatic processes of thermoelectricity to build a Carnot-like thermoelectric cycle, with the analysis based on fluctuation theorem (FT). First of all, the Carnot efficiency can be readily obtained for the quasi-static thermoelectric cycle, with the vanishing power. Moreover, the maximum power-efficiency pair of the finite-time thermoelectric cycle is derived, which is found to have the identical form to that of Brownian motors characterized by the stochastic thermodynamics. However, it is of significant discrepancy compared to the linear-irreversible and endoreversible-thermodynamics-based formulations. The distinction compared to the linear-irreversible-thermodynamics case could result from the difference in the definitions of Peltier and Seebeck coefficients in the thermoelectric cycle. As for the endoreversible thermodynamics, we argue the applicability of endoreversibility could be questionable for analyzing the thermoelectric cycle here, due to the incompatibility of the endoreversible hypothesis that attributes the irreversibility to finite heat transfer with thermal reservoirs, though the distinction of the mathematical expressions can vanish with the assumption that the ratio of thermoelectric power factors at the high and low temperatures is equal to the square root of the temperature ratio (this condition could significantly deviate from the practical case).
△ Less
Submitted 25 November, 2023; v1 submitted 26 October, 2023;
originally announced October 2023.
-
Performance Enhancement via XPM Suppression in a Linear all-PM NPE Mode-locked Fiber Oscillator
Authors:
Marvin Edelmann,
Yi Hua,
Mikhail Pergament,
Franz X. Kärtner
Abstract:
We demonstrate strong performance enhancement of an all polarization-maintaining fiber oscillator mode-locked using NPE in a linear self-stabilized fiber interferometer via suppression of cross-phase modulation (XPM). Numerical simulations reveal that XPM significantly affects the saturable absorber dynamics resulting in distortions of mode-locked steady-states. In the experiment, we construct an…
▽ More
We demonstrate strong performance enhancement of an all polarization-maintaining fiber oscillator mode-locked using NPE in a linear self-stabilized fiber interferometer via suppression of cross-phase modulation (XPM). Numerical simulations reveal that XPM significantly affects the saturable absorber dynamics resulting in distortions of mode-locked steady-states. In the experiment, we construct an oscillator with XPM suppression, employing an intra-cavity YVO4 crystal, and compare its characteristics with a reference oscillator in standard configuration. It is shown, that XPM suppression not only lowers the mode-locking threshold by more than 40%, but further results in improved spectral pulse quality at the output ports and reduced nonlinear loss of the artificial saturable absorber.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory
Authors:
Flynn B. Darby,
Michael Y. Hua,
Oskari V. Pakari,
Shaun D. Clarke,
Sara A. Pozzi
Abstract:
In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a s…
▽ More
In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.
△ Less
Submitted 8 August, 2023;
originally announced August 2023.
-
Highly sensitive single-molecule detection in slow protein ion beams
Authors:
M. Strauß,
A. Shayeghi,
M. F. X. Mauser,
P. Geyer,
T. Kostersitz,
J. Salapa,
O. Dobrovolskiy,
S. Daly,
J. Commandeur,
Y. Hua,
V. Köhler,
M. Mayor,
J. Benserhir,
C. Bruschini,
E. Charbon,
M. Castaneda,
M. Gevers,
R. Gourgues,
N. Kalhor,
A. Fognini,
M. Arndt
Abstract:
The analysis of proteins in the gas phase benefits from detectors that exhibit high efficiency and precise spatial resolution. Although modern secondary electron multipliers already address numerous analytical requirements, new methods are desired for macromolecules at low energy. Previous studies have proven the sensitivity of superconducting detectors to high-energy particles in time-of-flight m…
▽ More
The analysis of proteins in the gas phase benefits from detectors that exhibit high efficiency and precise spatial resolution. Although modern secondary electron multipliers already address numerous analytical requirements, new methods are desired for macromolecules at low energy. Previous studies have proven the sensitivity of superconducting detectors to high-energy particles in time-of-flight mass spectrometry. Here we explore a new energy regime and demonstrate that superconducting nanowire detectors are exceptionally well suited for quadrupole mass spectrometry. Our detectors exhibit an outstanding quantum yield at remarkably low impact energies. Notably, at low ion energy, their sensitivity surpasses conventional ion detectors by three orders of magnitude, and they offer the possibility to discriminate molecules by their impact energy and charge. By combining these detectors into arrays, we demonstrate low-energy ion beam profilometry, while our cryogenic electronics pave the way for future developments of highly integrated detectors.
△ Less
Submitted 26 June, 2023;
originally announced June 2023.
-
Improving structural damage tolerance and fracture energy via bamboo-inspired void patterns
Authors:
Xiaoheng Zhu,
Jiakun Liu,
Yucong Hua,
Ottman A. Tertuliano,
Jordan R. Raney
Abstract:
Bamboo has a functionally-graded microstructure that endows it with a combination of desirable properties, such as high failure strain, high toughness, and a low density. As a result, bamboo has been widely used in load-bearing structures. In this work, we study the use of bamboo-inspired void patterns to geometrically improve the failure properties of structures made from brittle polymers. We per…
▽ More
Bamboo has a functionally-graded microstructure that endows it with a combination of desirable properties, such as high failure strain, high toughness, and a low density. As a result, bamboo has been widely used in load-bearing structures. In this work, we study the use of bamboo-inspired void patterns to geometrically improve the failure properties of structures made from brittle polymers. We perform finite element analysis and experiments on 3D-printed structures to quantify the effect of the shape and spatial distribution of voids on the fracture behavior. The introduction of periodic, uniformly distributed voids in notched bend specimens leads to a 15-fold increase in the work of fracture relative to solid specimens. Adding a gradient to the pattern of voids leads to a cumulative 55-fold improvement in the work of fracture. Mechanistically, the individual voids result in crack blunting, which suppresses crack initiation, while neighboring voids redistribute stresses throughout the sample to enable large deformation before failure. In addition, we conduct qualitative, low-energy impact experiments on PMMA plates with laser-cut void patterns, illustrating the broader potential for this strategy to improve damage tolerance and energy absorption in a wide range of materials systems.
△ Less
Submitted 8 June, 2023;
originally announced June 2023.
-
Multifunctional acoustic device based on phononic crystal with independently controlled asymmetric rotating rods
Authors:
Hyeonu Heo,
Arkadii Krokhin,
Arup Neogi,
Zhiming Cui,
Zhihao Yuan,
Yihe Hua,
Jaehyung Ju,
Ezekiel Walker
Abstract:
A reconfigurable phononic crystal (PnC) is proposed where elastic properties can be modulated by rotation of asymmetric solid scatterers immersed in water. The scatterers are metallic rods with cross-section of 120° circular sector. Orientation of each rod is independently controlled by an external electric motor that allows continuous variation of the local scattering parameters and dispersion of…
▽ More
A reconfigurable phononic crystal (PnC) is proposed where elastic properties can be modulated by rotation of asymmetric solid scatterers immersed in water. The scatterers are metallic rods with cross-section of 120° circular sector. Orientation of each rod is independently controlled by an external electric motor that allows continuous variation of the local scattering parameters and dispersion of sound in the entire crystal. Due to asymmetry of the scatterers, the crystal band structure possesses highly anisotropic bandgaps. Synchronous rotation of all the scatterers by a definite angle changes regime of reflection to regime of transmission and vice versa. The same mechanically tunable structure functions as a gradient index medium by incremental, angular reorientation of rods along both row and column, and, subsequently, can serve as a tunable acoustic lens, an acoustic beam splitter, and finally an acoustic beam steerer.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
The omnidirectional receiver for UWOC systems based on the diffractive deep neural network
Authors:
Jianmin Xiong,
Jingxuan Cheng,
Huan Deng,
Yan Hua,
Yufan Zhang,
Zihao Du,
Lyufang Zhao,
Zejun Zhang,
Jing Xu
Abstract:
The link alignment requirement in underwater wireless optical communication (UWOC) systems is a knotty problem. The diffractive deep neural network (D2NN) has shown great potential in accomplishing tasks all optically these years. In this paper, an omnidirectional receiver based on 7-layer D2NN is first proposed to alleviate the link alignment difficulties in UWOC systems. In addition, the vectori…
▽ More
The link alignment requirement in underwater wireless optical communication (UWOC) systems is a knotty problem. The diffractive deep neural network (D2NN) has shown great potential in accomplishing tasks all optically these years. In this paper, an omnidirectional receiver based on 7-layer D2NN is first proposed to alleviate the link alignment difficulties in UWOC systems. In addition, the vectorial diffraction theory is introduced into the training of the D2NN to obtain more accurate diffraction calculations compared with the prevalently adopted scalar diffraction theory. Simulation results verify the validity of the vectorial diffraction theory and demonstrate that the presented method can focus incident light waves with tilt angles from 0 to 89 degrees in a 6.25% area of the detection plane with an average focusing efficiency of 90.96%, proving the feasibility of omnidirectional focusing at the receiver end. Extra simulations further reveal that more layers do not lead to a sustained performance improvement but rather reach a bottleneck, and the D2NN can achieve omnidirectional focusing with a certain range of focusing region size. With more effort, the proposed receiver design, which can be highly integrated with detectors, holds promise to realize both omnidirectional and reliable link establishment in UWOC systems in the future.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.
-
Large-mode-area Soliton Fiber Oscillator Mode-locked with Linear Self-stabilized Interferometer
Authors:
Marvin Edelmann,
Malek M. Sedigheh,
Yi Hua,
Erwin C. Vargas,
Mikhail Pergament,
Franz X. Kärtner
Abstract:
In this work, we investigate an approach to scale up the output pulse energy in an all polarization-maintaining 17 MHz Yb-doped fiber oscillator via implementation of 25 um core-diameter large-mode-area fibers. The artificial saturable absorber in form of a Kerr-type self-stabilized fiber-interferometer enables highly stable mode-locked steady-states in the soliton-like operation regime with 170 m…
▽ More
In this work, we investigate an approach to scale up the output pulse energy in an all polarization-maintaining 17 MHz Yb-doped fiber oscillator via implementation of 25 um core-diameter large-mode-area fibers. The artificial saturable absorber in form of a Kerr-type self-stabilized fiber-interferometer enables highly stable mode-locked steady-states in the soliton-like operation regime with 170 mW average output power and a total output pulse energy of ~10 nJ distributed between two output ports. An experimental parameter comparison with a reference oscillator made of 5.5 um core-sized standard fiber-components reveals an increase of pulse energy by a factor of 36 with simultaneously reduced intensity-noise in the high frequency range > 100 kHz.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Nonproliferation and fusion power plants
Authors:
Michael Y. Hua,
Sachin S. Desai,
Amy C. Roma,
Angela Di Fulvio,
Craig J. Mundie,
Sara A. Pozzi
Abstract:
This is an abridged abstract; please see the full paper. This paper evaluates whether the nuclear nonproliferation regime applies to fusion power plants and finds that, legally, the regime does not apply. The paper then examines whether the nonproliferation regime should apply to fusion based on a technical evaluation. The paper concludes that fusion should continue to fall outside the nonprolifer…
▽ More
This is an abridged abstract; please see the full paper. This paper evaluates whether the nuclear nonproliferation regime applies to fusion power plants and finds that, legally, the regime does not apply. The paper then examines whether the nonproliferation regime should apply to fusion based on a technical evaluation. The paper concludes that fusion should continue to fall outside the nonproliferation regime and that the global, dual-use export control regime, including potentially developing a "controls by design" usage-based control regime, is better suited for commercial fusion energy.
△ Less
Submitted 23 August, 2022; v1 submitted 28 July, 2022;
originally announced July 2022.
-
Spectral Thermal Spreading Resistance of Wide Bandgap Semiconductors in Ballistic-Diffusive Regime
Authors:
Yang Shen,
Yu-Chao Hua,
Han-Ling Li,
S. L. Sobolev,
Bing-Yang Cao
Abstract:
To develop efficient thermal management strategies for wide bandgap (WBG) semiconductor devices, it is essential to have a clear understanding of the heat transport process within the device and accurately predict the junction temperature. In this paper, we used the phonon Monte Carlo (MC) method with the phonon dispersion of various typical WBG semiconductors, including GaN, SiC, AlN, and \ce{β-G…
▽ More
To develop efficient thermal management strategies for wide bandgap (WBG) semiconductor devices, it is essential to have a clear understanding of the heat transport process within the device and accurately predict the junction temperature. In this paper, we used the phonon Monte Carlo (MC) method with the phonon dispersion of various typical WBG semiconductors, including GaN, SiC, AlN, and \ce{β-Ga_2O_3}, to investigate the thermal spreading resistance in a ballistic-diffusive regime. It was found that when compared with Fourier's law-based predictions, the increase in the thermal resistance caused by ballistic effects was strongly related to different phonon dispersions. Based on the model deduced under the gray-medium approximation and the results of dispersion MC, we obtained a thermal resistance model that can well address the issues of thermal spreading and ballistic effects, and the influences of phonon dispersion. The model can be easily coupled with FEM based thermal analysis and applied to different materials. This paper can provide a clearer understanding of the influences of phonon dispersion on the thermal transport process, and it can be useful for the prediction of junction temperatures and the development of thermal management strategies for WBG semiconductor devices.
△ Less
Submitted 11 January, 2022;
originally announced January 2022.
-
All-PM Divided Pulse Fiber Oscillator Mode-locked with the Optical Kerr-effect
Authors:
Marvin Edelmann,
Yi Hua,
Gabor Kulscar,
Franz X. Kärtner
Abstract:
In this letter, we investigate a Yb-doped mode-locked fiber oscillator that uses coherent pulse division and recombination to avoid excessive nonlinear phase shifts. The mode-locking mechanism of the laser is based on the accumulation of a differential nonlinear phase between orthogonal polarization modes in the polarization-maintaining fiber segment. The inserted coherent pulse divider, based on…
▽ More
In this letter, we investigate a Yb-doped mode-locked fiber oscillator that uses coherent pulse division and recombination to avoid excessive nonlinear phase shifts. The mode-locking mechanism of the laser is based on the accumulation of a differential nonlinear phase between orthogonal polarization modes in the polarization-maintaining fiber segment. The inserted coherent pulse divider, based on YVO4-crystals rotated successively by 45°, enables stable and undistorted mode-locked steady-states. The output pulse energy is increased from 89 pJ in the non-divided operation by ~6.5 dB to more than 400 pJ with three divisions. Measurements of the amplitude-fluctuations reveal a simultaneous broadband reduction of up to ~9 dB in the frequency range from 10 kHz to 2MHz.
△ Less
Submitted 28 August, 2021;
originally announced August 2021.
-
Nonlinear Fiber System for Shot-noise Limited Intensity Noise Suppression and Amplification
Authors:
Marvin Edelmann,
Yi Hua,
Kemal Şafak,
Franz X. Kärtner
Abstract:
We propose a nonlinear fiber system for shot-noise limited, all-optical intensity-noise reduction and signal amplification. The mechanism is based on the accumulation of different nonlinear phase shifts between orthogonal polarization modes in a polarization-maintaining fiber amplifier in combination with an implemented sinusoidal transmission-function. The resulting correlation between the input…
▽ More
We propose a nonlinear fiber system for shot-noise limited, all-optical intensity-noise reduction and signal amplification. The mechanism is based on the accumulation of different nonlinear phase shifts between orthogonal polarization modes in a polarization-maintaining fiber amplifier in combination with an implemented sinusoidal transmission-function. The resulting correlation between the input intensity-fluctuations and the system transmission enables tunable intensity noise reduction of the input pulse train. In the experiment, the noise spectral density of a mode-locked oscillator is suppressed by up to ~20 dB to the theoretical shot-noise limit of the measurement at -151.3 dBc/Hz with simultaneous pulse amplification of 13.5dB.
△ Less
Submitted 10 May, 2021;
originally announced May 2021.
-
A pulse oximeter based on Time-of-Flight histograms
Authors:
Yuanyuan Hua,
Konstantinos Bantounos,
Aravind Venugopalan Nair Jalajakumari,
Alex Turpin,
Ian Underwood,
Danial Chitnis
Abstract:
A pulse oximeter is an optical device that monitors tissue oxygenation levels. Traditionally, these devices estimate the oxygenation level by measuring the intensity of the transmitted light through the tissue and are embedded into everyday devices such as smartphones and smartwatches. However, these sensors require prior information and are susceptible to unwanted changes in the intensity, includ…
▽ More
A pulse oximeter is an optical device that monitors tissue oxygenation levels. Traditionally, these devices estimate the oxygenation level by measuring the intensity of the transmitted light through the tissue and are embedded into everyday devices such as smartphones and smartwatches. However, these sensors require prior information and are susceptible to unwanted changes in the intensity, including ambient light, skin tone, and motion artefacts. Previous experiments have shown the potential of Time-of-Flight (ToF) techniques in measurements of tissue hemodynamics. Our proposed technology uses histograms of photon flight paths within the tissue to obtain tissue oxygenation, regardless of the changes in the intensity of the source. Our device is based on a 45ps time-to-digital converter (TDC) which is implemented in a Xilinx Zynq UltraScale+ field programmable gate array (FPGA), a CMOS Single Photon Avalanche Diode (SPAD) detector, and a low-cost compact laser source. All these components including the SPAD detector are manufactured using the latest commercially available technology, which leads to increased linearity, accuracy, and stability for ToF measurements. This proof-of-concept system is approximately 10cmx8cmx5cm in size, with a high potential for shrinkage through further system development and component integration. We demonstrate preliminary results of ToF pulse measurements and report the engineering details, trade-offs, and challenges of this design. We discuss the potential for mass adoption of ToF based pulse oximeters in everyday devices such as smartphones and wearables.
△ Less
Submitted 25 February, 2021;
originally announced February 2021.
-
Development of a PET/EPRI combined imaging system for assessing tumor hypoxia
Authors:
Heejong Kim,
Boris Epel,
Subramanian Sundramoorthy,
Hsiu-Ming Tsai,
Eugene Barth,
Inna Gertsenshteyn,
Howard Halpern,
Yuexuan Hua,
Qingguo Xie,
Chin-Tu Chen,
Chien-Min Kao
Abstract:
Precise quantitative delineation of tumor hypoxia is essential in radiation therapy treatment planning to improve the treatment efficacy by targeting hypoxic sub-volumes. We developed a combined imaging system of positron emission tomography (PET) and electron para-magnetic resonance imaging (EPRI) of molecular oxygen to investigate the accuracy of PET imaging in assessing tumor hypoxia. The PET/E…
▽ More
Precise quantitative delineation of tumor hypoxia is essential in radiation therapy treatment planning to improve the treatment efficacy by targeting hypoxic sub-volumes. We developed a combined imaging system of positron emission tomography (PET) and electron para-magnetic resonance imaging (EPRI) of molecular oxygen to investigate the accuracy of PET imaging in assessing tumor hypoxia. The PET/EPRI combined imaging system aims to use EPRI to precisely measure the oxygen partial pressure in tissues. This will evaluate the validity of PET hypoxic tumor imaging by (near) simultaneously acquired EPRI as ground truth. The combined imaging system was constructed by integrating a small animal PET scanner (inner ring diameter 62 mm and axial field of view 25.6 mm) and an EPRI subsystem (field strength 25 mT and resonant frequency 700 MHz). The compatibility between the PET and EPRI subsystems were tested with both phantom and animal imaging. Hypoxic imaging on a tumor mouse model using $^{18}$F-fluoromisonidazole radio-tracer was conducted with the developed PET/EPRI system. We report the development and initial imaging results obtained from the PET/EPRI combined imaging system.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
Compact, all-PM fiber integrated and alignment-free ultrafast Yb:fiber NALM laser with sub-femtosecond timing jitter
Authors:
Yuxuan Ma,
Sarper H. Salman,
Chen Li,
Christoph Mahnke,
Yi Hua,
Stefan Droste,
Jakob Fellinger,
Aline S. Mayer,
Oliver H. Heckl,
Christoph M. Heyl,
Ingmar Hartl
Abstract:
We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design paramet…
▽ More
We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design parameters were determined by numerically simulating the pulse evolution in the oscillator and by analyzing their impact on the laser performance. Experimentally, we achieved an 88 fs compressed pulse duration with sub-fs timing jitter at 54 MHz repetition rate and 51 mW of output power with 5.5 * 10-5 [20 Hz, 1 MHz] integrated relative intensity noise (RIN). Furthermore, we demonstrate tight phase-locking of the laser's carrier-envelope offset frequency (fceo) to a stable radio frequency (RF) reference and of one frequency comb tooth to a stable optical reference at 291 THz.
△ Less
Submitted 8 January, 2021;
originally announced January 2021.
-
Fast Rossi-alpha Measurements of Plutonium using Organic Scintillators
Authors:
M. Y. Hua,
C. A. Bravo,
A. T. MacDonald,
J. D. Hutchinson,
G. E. McKenzie,
T. J. Grove,
J. M. Goda,
A. T. McSpaden,
S. D. Clarke,
S. A. Pozzi
Abstract:
In this work, Rossi-alpha measurements were simultaneously performed with a $^3$He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt$\%$ $^{239}$Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_\text{eff}$ = 0.624 and…
▽ More
In this work, Rossi-alpha measurements were simultaneously performed with a $^3$He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt$\%$ $^{239}$Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_\text{eff}$ = 0.624 and $α$ = 52.3 $\pm$ 2.5 ns for the measured assembly. The organic scintillator system estimated $α$ = 47.4 $\pm$ 2.0 ns, having a 9.37$\%$ error (though the 1.09 standard deviation confidence intervals overlapped). The $^3$He system estimated $α$ = 37 $μ$s. The known slowing down time of the $^3$He system is 35-40 $μ$s, which means the slowing down time dominates and obscures the prompt neutron decay constant. Subsequently, the organic scintillator system should be used for assemblies with alpha much less than 35 $μ$s.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Intrinsic Amplitude-Noise Suppression in Fiber Lasers Mode-locked with Nonlinear Amplifying Loop Mirrors
Authors:
Marvin Edelmann,
Yi Hua,
Kemal Şafak,
Franz X. Kärtner
Abstract:
In this work, we investigate the steady-states of a fiber lasers mode-locked with a nonlinear amplifying loop-mirror that has an inherent amplitude noise-suppression mechanism. Due to the interaction of the sinusoidal transmission function with the fluctuating intracavity pulse amplitude we show that this mechanism may lead to a detectable difference in relative intensity noise at the reflected an…
▽ More
In this work, we investigate the steady-states of a fiber lasers mode-locked with a nonlinear amplifying loop-mirror that has an inherent amplitude noise-suppression mechanism. Due to the interaction of the sinusoidal transmission function with the fluctuating intracavity pulse amplitude we show that this mechanism may lead to a detectable difference in relative intensity noise at the reflected and transmitted output port under specific preconditions. We present systematic intensity noise measurements with a nonlinear fiber-based system that replicates a single roundtrip in the laser cavity. Experimental results and simulations clearly show a reduction of the intracavity amplitude fluctuations up to 4 dB for certain steady-states.
△ Less
Submitted 10 November, 2020; v1 submitted 26 October, 2020;
originally announced October 2020.
-
On the Feynman-alpha Method for Reflected Fissile Assemblies
Authors:
Michael Y. Hua,
Jesson D. Hutchinson,
George E. McKenzie,
Shaun D. Clarke,
Sara A. Pozzi
Abstract:
The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the $k_\text{eff}$ multiplication factor. The F…
▽ More
The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the $k_\text{eff}$ multiplication factor. The Feynman-alpha method is predicated on time-correlated neutron detections that deviate from a Poisson random variable due to multiplication. Traditionally, such measurements are diagnosed with one-region point kinetics, but two-region models are required when the fissile assembly is reflected. This paper presents a derivation of the two-region point kinetics Feynman-alpha equations based on a double integration of the Rossi-alpha equations, develops novel propagation of measurement uncertainty, and validates the theory. Validation is achieved with organic scintillator measurements of weapons-grade plutonium reflected by various amounts of copper to achieve $k_\text{eff}$ values of 0.83-0.94 and prompt periods of 5-75 ns. The results demonstrate that Feynman-alpha measurements should use the two-region model instead of the one-region model. The simplified one-region model deviates from the validated two-region models by as much as 10\% in the estimate of the prompt neutron period, and the two-region model reduces to the one-region model for small amounts of reflector. The Feynman-alpha estimates of the prompt neutron period are compared to those of the Rossi-alpha approach. The comparative results demonstrate that the Feynman-alpha method is more precise than the Rossi-alpha method and more accurate for $k_\text{eff}<0.92$, whereas the Rossi-alpha method is generally more accurate for higher multiplications.
△ Less
Submitted 2 November, 2020; v1 submitted 22 October, 2020;
originally announced October 2020.
-
Rossi-alpha Uncertainty Quantification by Analytic, Bootstrap, and Sample Methods to Inform Fitting Best Practices
Authors:
M. Y. Hua,
C. A. Bravo,
R. M. Marchie,
J. D. Hutchinson,
G. E. McKenzie,
S. A. Pozzi
Abstract:
The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi-alpha histograms and of interest in nuclear criticality safety and nonproliferation [1, 2, 3]. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to acc…
▽ More
The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi-alpha histograms and of interest in nuclear criticality safety and nonproliferation [1, 2, 3]. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector-induced phenomenon [4, 5, 6]. Until recently, the uncertainty quantification for either model was inadequate (inaccurate and demanded large measurement times). Measurement uncertainty quantification by sample and analytic methods was developed and validated in Ref. [7]. The purpose of this transaction is to (i) validate a new bootstrap method by comparing bin-by-bin error bar estimates and (ii) demonstrate how to choose bin widths and reset times to optimize precision and accuracy.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Measured Nondestructive Assay of $^{237}$Np Using Organic Scintillators and Active Neutron Multiplicity Counting
Authors:
Michael Y. Hua,
Thomas A. Plummer,
Jesson D. Hutchinson,
George E. McKenzie,
Shaun D. Clarke,
Sara A. Pozzi
Abstract:
The purpose of nondestructive assay in the context of nuclear safeguards is to precisely verify the declared mass of a sample of nuclear material in a noninhibitive amount of time. 237Np is a proliferation concern, and the capacity to efficiently assay samples of it is a missing piece in the verification and safeguards toolbox. The material is subject to the same safeguards as 235U, is reportable…
▽ More
The purpose of nondestructive assay in the context of nuclear safeguards is to precisely verify the declared mass of a sample of nuclear material in a noninhibitive amount of time. 237Np is a proliferation concern, and the capacity to efficiently assay samples of it is a missing piece in the verification and safeguards toolbox. The material is subject to the same safeguards as 235U, is reportable in gram quantities, and is classified as "other nuclear material" according to the United States Department of Energy. Given that 3000 kg of 237Np is annually produced in the US and the bare sphere critical mass is 40-60 kg, it is desirable to augment the safeguards toolbox with a system capable of distinguishing 10 g of 237Np in a 20-minute measurement. One measurement modality is neutron multiplicity counting, which relates the detected multiplicity count rates to the amount of fissionable material. Prior simulation work shows that an organic scintillator-based multiplicity counter can achieve the design criteria, whereas the flagship 3He-based system, the Epithermal Neutron Multiplicity Counter, requires much longer measurement times to achieve the same precision. In this work, simultaneous measurements of a 6-kg sphere of 237Np by organic scintillator- and 3He-based systems are used to confirm the trends in the simulation study; the organic scintillator-based system achieves 1% uncertainty in the neutron double multiplicity rate on the order of minutes, while the 3He-based system requires days to reach the same precision. In conclusion, the International Atomic Energy Agency should consider the development and deployment of an organic scintillator-based multiplicity counter
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Reversible Reciprocal Relation of Thermoelectricity
Authors:
Yu-Chao Hua,
Ti-Wei Xue,
Zeng-Yuan Guo
Abstract:
The first Kelvin relation that states the Peltier coefficient should be equal to the product of temperature and Seebeck coefficient is a fundamental principle in thermoelectricity. It has been regarded as an important application and direct experimental verification of Onsager reciprocal relation (ORR) that is a cornerstone of irreversible thermodynamics. However, some critical questions still rem…
▽ More
The first Kelvin relation that states the Peltier coefficient should be equal to the product of temperature and Seebeck coefficient is a fundamental principle in thermoelectricity. It has been regarded as an important application and direct experimental verification of Onsager reciprocal relation (ORR) that is a cornerstone of irreversible thermodynamics. However, some critical questions still remain: why Kelvin's proof that omits all irreversibility within a thermoelectric transport process can reach the correct result, how to properly select the generalized-force-flux pairs for deriving the first Kelvin relation from ORR, and whether the first Kelvin relation is restricted by the requirement of linear transport regime. The present work is to answer these questions based on the fundamental thermodynamic principles. Since the thermoelectric effects are reversible, we can redefine the Seebeck and Peltier coefficients using the quantities in reversible processes with no time derivative involved, which are renamed as "reversible Seebeck and Peltier coefficients". The relation between them (called "the reversible reciprocal relation of thermoelectricity") is derived from the Maxwell relations, which can be reduced to the conventional Kelvin relation, when the local equilibrium assumption (LEA) is adopted. In this sense, the validity of the first Kelvin relation is guaranteed by the reversible thermodynamic principles and LEA, without the requirement of linear transport process. Additionally, the generalized force-flux pairs to obtain the first Kelvin relation from ORR can be proper both mathematically and thermodynamically, only when they correspond to the conjugate-variable pairs of which Maxwell relations can yield the reversible reciprocal relation. The present theoretical framework can be further extended to other coupled phenomena.
△ Less
Submitted 14 September, 2020; v1 submitted 12 September, 2020;
originally announced September 2020.
-
Development of the Soft X-ray AGM-AGS RIXS Beamline at Taiwan Photon Source
Authors:
A. Singh,
H. Y. Huang,
Y. Y. Chu,
C. Y. Hua,
S. W. Lin,
H. S. Fung,
H. W. Shiu,
J. Chang,
J. H. Li,
J. Okamoto,
C. C. Chiu,
C. H. Chang,
W. B. Wu,
S. Y. Perng,
S. C. Chung,
K. Y. Kao,
S. C. Yeh,
H. Y. Chao,
J. H. Chen,
D. J. Huang,
C. T. Chen
Abstract:
We report on the development of a high-resolution and highly efficient beamline for soft-X-ray resonant inelastic X-ray scattering (RIXS) located at Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to…
▽ More
We report on the development of a high-resolution and highly efficient beamline for soft-X-ray resonant inelastic X-ray scattering (RIXS) located at Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angle over a wide range. Several high-precision instruments developed in house for this beamline are briefly described. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power 42,000, while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impacts of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, La$_{2-x}$Sr$_x$CuO$_4$. The measurements reveal the A$_{1g}$ apical oxygen phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge density waves.
△ Less
Submitted 24 June, 2020; v1 submitted 23 June, 2020;
originally announced June 2020.
-
CMOS compatible high-performance nanolasing based on perovskite-SiN hybrid integration
Authors:
Z. He,
B. Chen,
Y. Hua,
Z. Liu,
Y. Wei,
S. Liu,
A. Hu,
X. Shen,
Y. Zhang,
Y. Gao,
J. Liu
Abstract:
Coherent light sources in silicon photonics are the long-sought holy grail because silicon-based materials have indirect bandgap. Traditional strategies for realizing such sources, e.g., heterogeneous photonic integration, strain engineering and nonlinear process, are technologically demanding. Here, we demonstrate a hybrid lasing device composing of perovskite nanocrystals and silicon nitride nan…
▽ More
Coherent light sources in silicon photonics are the long-sought holy grail because silicon-based materials have indirect bandgap. Traditional strategies for realizing such sources, e.g., heterogeneous photonic integration, strain engineering and nonlinear process, are technologically demanding. Here, we demonstrate a hybrid lasing device composing of perovskite nanocrystals and silicon nitride nanobeam cavity. We fabricate SiN photonic crystal naonobeam cavities on a solid substrate with significantly improved thermal and mechanical stabilities compared to conventional suspended ones. In addition, adding a PMMA-encapsulation layer on top of the SiN can significantly boost the Q-factor of the cavity mode. By dispersing perovskite nanocrystals as emitters in the PMMA layer, we obtained high-performance coherent emissions in terms of lasing threshold, linewidth and mode volumes. Our work offers a compelling way of creating solution-processed active integrated photonic devices based on the mature platform of silicon photonics for applications in optical information science and photonic quantum technology.
△ Less
Submitted 30 March, 2020;
originally announced March 2020.
-
Multiplexed storage and real-time manipulation based on a multiple-degree-of-freedom quantum memory
Authors:
Tian-Shu Yang,
Zong-Quan Zhou,
Yi-Lin Hua,
Xiao Liu,
Zong-Feng Li,
Pei-Yun Li,
Yu Ma,
Chao Liu,
Peng-Jun Liang,
Xue Li,
Yi-Xin Xiao,
Jun Hu,
Chuan-Feng Li,
Guang-Can Guo
Abstract:
The faithful storage and coherent manipulation of quantum states with matter-systems enable the construction of large-scale quantum networks based on quantum repeater. To achieve useful communication rates, highly multimode quantum memories will be required to construct a multiplexed quantum repeater. Here, we present the first demonstration of the on-demand storage of orbital-angular-momentum sta…
▽ More
The faithful storage and coherent manipulation of quantum states with matter-systems enable the construction of large-scale quantum networks based on quantum repeater. To achieve useful communication rates, highly multimode quantum memories will be required to construct a multiplexed quantum repeater. Here, we present the first demonstration of the on-demand storage of orbital-angular-momentum states with weak coherent pulses at the single-photon-level in a rare-earth-ion doped crystal. Through the combination of this spatial degree-of-freedom with temporal and spectral degrees of freedom, we create a multiple-degree-of-freedom memory with high multimode capacity. This device can serve as a quantum mode converter with high fidelity, which is the fundamental requirements for the construction of a multiplexed quantum repeater. This device further enables essentially arbitrary spectral and temporal manipulations of spatial-qutrit-encoded photonic pulses in real-time. Therefore, the developed quantum memory can serve as a building block for scalable photonic quantum information processing architectures.
△ Less
Submitted 5 September, 2018; v1 submitted 5 August, 2018;
originally announced August 2018.
-
Conversations Gone Awry: Detecting Early Signs of Conversational Failure
Authors:
Justine Zhang,
Jonathan P. Chang,
Cristian Danescu-Niculescu-Mizil,
Lucas Dixon,
Yiqing Hua,
Nithum Thain,
Dario Taraborelli
Abstract:
One of the main challenges online social systems face is the prevalence of antisocial behavior, such as harassment and personal attacks. In this work, we introduce the task of predicting from the very start of a conversation whether it will get out of hand. As opposed to detecting undesirable behavior after the fact, this task aims to enable early, actionable prediction at a time when the conversa…
▽ More
One of the main challenges online social systems face is the prevalence of antisocial behavior, such as harassment and personal attacks. In this work, we introduce the task of predicting from the very start of a conversation whether it will get out of hand. As opposed to detecting undesirable behavior after the fact, this task aims to enable early, actionable prediction at a time when the conversation might still be salvaged.
To this end, we develop a framework for capturing pragmatic devices---such as politeness strategies and rhetorical prompts---used to start a conversation, and analyze their relation to its future trajectory. Applying this framework in a controlled setting, we demonstrate the feasibility of detecting early warning signs of antisocial behavior in online discussions.
△ Less
Submitted 14 May, 2018;
originally announced May 2018.
-
Segmented Terahertz Electron Accelerator and Manipulator (STEAM)
Authors:
Dongfang Zhang,
Arya Fallahi,
Michael Hemmer,
Xiaojun Wu,
Moein Fakhari,
Yi Hua,
Huseyin Cankaya,
Anne-Laure Calendron,
Luis E. Zapata,
Nicholas H. Matlis,
Franz X. Kärtner
Abstract:
Acceleration and manipulation of ultrashort electron bunches are the basis behind electron and X-ray devices used for ultrafast, atomic-scale imaging and spectroscopy. Using laser-generated THz drivers enables intrinsic synchronization as well as dramatic gains in field strengths, field gradients and component compactness, leading to shorter electron bunches, higher spatio-temporal resolution and…
▽ More
Acceleration and manipulation of ultrashort electron bunches are the basis behind electron and X-ray devices used for ultrafast, atomic-scale imaging and spectroscopy. Using laser-generated THz drivers enables intrinsic synchronization as well as dramatic gains in field strengths, field gradients and component compactness, leading to shorter electron bunches, higher spatio-temporal resolution and smaller infrastructures. We present a segmented THz electron accelerator and manipulator (STEAM) with extended interaction lengths capable of performing multiple high-field operations on the energy and phase-space of ultrashort bunches with moderate charge. With this single device, powered by few-microjoule, single-cycle, 0.3 THz pulses, we demonstrate record THz-device acceleration of >30 keV, streaking with <10 fs resolution, focusing with >2 kT/m strengths, compression to ~100 fs as well as real-time switching between these modes of operation. The STEAM device demonstrates the feasibility of future THz-based compact electron guns, accelerators, ultrafast electron diffractometers and Free-Electron Lasers with transformative impact.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Non-Equilibrium Molecular Dynamics Simulation of Poiseuille Flow in a Carbon Nanochannel
Authors:
Guo Liang Ni,
Ming Li He,
Yao Zu Hua,
Bagher Abareshi
Abstract:
The numerical simulation of a Poiseuille flow in a narrow channel using the molecular dynamics simulation (MDS) is performed. Poiseuille flow of liquid Argon in a carbon nanochannel is simulated by embedding the fluid particles in a uniform force field. Density, velocity and Temperature profiles across the channel are investigated. When particles will be inserted into the flow, it is expected that…
▽ More
The numerical simulation of a Poiseuille flow in a narrow channel using the molecular dynamics simulation (MDS) is performed. Poiseuille flow of liquid Argon in a carbon nanochannel is simulated by embedding the fluid particles in a uniform force field. Density, velocity and Temperature profiles across the channel are investigated. When particles will be inserted into the flow, it is expected that the dynamics of flow will depend on the thermostat chosen. To obtain a more uniform temperature distribution across the channel we use local thermostating near the wall. The obtained results show that velocity profile, slip length and slip velocity depends on the driving force.
△ Less
Submitted 16 August, 2017; v1 submitted 3 August, 2017;
originally announced August 2017.
-
Storage of multiple single-photon pulses emitted from a quantum dot in a solid-state quantum memory
Authors:
Jian-Shun Tang,
Zong-Quan Zhou,
Yi-Tao Wang,
Yu-Long Li,
Xiao Liu,
Yi-Lin Hua,
Yang Zou,
Shuang Wang,
De-Yong He,
Geng Chen,
Yong-Nan Sun,
Ying Yu,
Mi-Feng Li,
Guo-Wei Zha,
Hai-Qiao Ni,
Zhi-Chuan Niu,
Chuan-Feng Li,
Guang-Can Guo
Abstract:
Quantum repeaters are critical components for distributing entanglement over long distances in presence of unavoidable optical losses during transmission. Stimulated by Duan-Lukin-Cirac-Zoller protocol, many improved quantum-repeater protocols based on quantum memories have been proposed, which commonly focus on the entanglement-distribution rate. Among these protocols, the elimination of multi-ph…
▽ More
Quantum repeaters are critical components for distributing entanglement over long distances in presence of unavoidable optical losses during transmission. Stimulated by Duan-Lukin-Cirac-Zoller protocol, many improved quantum-repeater protocols based on quantum memories have been proposed, which commonly focus on the entanglement-distribution rate. Among these protocols, the elimination of multi-photons (multi-photon-pairs) and the use of multimode quantum memory are demonstrated to have the ability to greatly improve the entanglement-distribution rate. Here, we demonstrate the storage of deterministic single photons emitted from a quantum dot in a polarization-maintaining solid-state quantum memory; in addition, multi-temporal-mode memory with $1$, $20$ and $100$ narrow single-photon pulses is also demonstrated. Multi-photons are eliminated, and only one photon at most is contained in each pulse. Moreover, the solid-state properties of both sub-systems make this configuration more stable and easier to be scalable. Our work will be helpful in the construction of efficient quantum repeaters based on all-solid-state devices
△ Less
Submitted 19 October, 2015;
originally announced October 2015.
-
Simultaneously plasmon lasing and spasing behavior in a silver grating-film geometry
Authors:
Lina Shi,
Hailiang Li,
Feng Jin,
Jiebin Niu,
Yilei Hua,
Changqing Xie
Abstract:
By using a self-consistent Maxwell-Bloch method, we demonstrate the simultaneously lasing and spasing behavior in a simple metal grating-film nanostructure, which can be attributed to spatial hole burning and the gain competition of different modes at the band edge and in the plasmonic band gap. We show three modes: one spaser mode in gap with quality factor as high as 248.54, one plasmon lasing m…
▽ More
By using a self-consistent Maxwell-Bloch method, we demonstrate the simultaneously lasing and spasing behavior in a simple metal grating-film nanostructure, which can be attributed to spatial hole burning and the gain competition of different modes at the band edge and in the plasmonic band gap. We show three modes: one spaser mode in gap with quality factor as high as 248.54, one plasmon lasing mode at band edge which emit vertically from the grating surface, and the other plasmon lasing mode at band edge which is suppressed by the spaser mode. This method may find significant applications in coherent light and surface plasmon sources with low threshold, surface enhanced Raman scattering, solid-state lighting emission, etc.
△ Less
Submitted 10 March, 2014;
originally announced March 2014.