-
Real-time Autonomous Control of a Continuous Macroscopic Process as Demonstrated by Plastic Forming
Authors:
Shun Muroga,
Takashi Honda,
Yasuaki Miki,
Hideaki Nakajima,
Don N. Futaba,
Kenji Hata
Abstract:
To meet the demands for more adaptable and expedient approaches to augment both research and manufacturing, we report an autonomous system using real-time in-situ characterization and an autonomous, decision-making processer based on an active learning algorithm. This system was applied to a plastic film forming system to highlight its efficiency and accuracy in determining the process conditions…
▽ More
To meet the demands for more adaptable and expedient approaches to augment both research and manufacturing, we report an autonomous system using real-time in-situ characterization and an autonomous, decision-making processer based on an active learning algorithm. This system was applied to a plastic film forming system to highlight its efficiency and accuracy in determining the process conditions for specified target film dimensions, importantly, without any human intervention. Application of this system towards nine distinct film dimensions demonstrated the system ability to quickly determine the appropriate and stable process conditions (average 11 characterization-adjustment iterations, 19 minutes) and the ability to avoid traps, such as repetitive over-correction. Furthermore, comparison of the achieved film dimensions to the target values showed a high accuracy (R2 = 0.87, 0.90) for film width and thickness, respectively. In addition, the use of an active learning algorithm afforded our system to proceed optimization with zero initial training data, which was unavailable due to the complex relationships between the control factors (material supply rate, applied force, material viscosity) within the plastic forming process. As our system is intrinsically general and can be applied to any most material processes, these results have significant implications in accelerating both research and industrial processes.
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Estimation of Newtonian noise from KAGRA cooling system
Authors:
Rishabh Bajpai,
Takayuki Tomaru,
Toshikazu Suzuki,
Kazuhiro Yamamoto,
Takafumi Ushiba,
Tohru Honda
Abstract:
KAGRA is the first km-scale gravitational wave detector to be constructed underground and employ cryogenics to cool down its test masses. While the underground location provides a quiet site with low seismic noise, the cooling infrastructure is known to generate large mechanical vibrations due to cryocooler operation and structural resonances of the cryostat. As cooling system components are relat…
▽ More
KAGRA is the first km-scale gravitational wave detector to be constructed underground and employ cryogenics to cool down its test masses. While the underground location provides a quiet site with low seismic noise, the cooling infrastructure is known to generate large mechanical vibrations due to cryocooler operation and structural resonances of the cryostat. As cooling system components are relatively heavy and in close proximity to the test masses, oscillation of gravity force induced by their vibration, so-called Newtonian noise, could contaminate the detector sensitivity. In this paper, we use the results from vibration analysis of the KAGRA cryostat to estimate cooling system Newtonian noise in the 1-100 Hz frequency band. Our calculations show that, while this noise does not limit the current detector sensitivity or inspiral range, it will be an issue in the future when KAGRA improves its sensitivity. We conclude that KAGRA may need to implement Wiener filters to subtract this noise in the future.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
A laser interferometer accelerometer for vibration sensitive cryogenic experiments
Authors:
Rishabh Bajpai,
Takayuki Tomaru,
Kazuhiro Yamamoto,
Takafumi Ushiba,
Nobuhiro Kimura,
Toshikazu Suzuki,
Tomohiro Yamada,
Tohru Honda
Abstract:
Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no commercial cryogenic accelerometers are available, we developed a compact self-calibrating accelerometer with a Michelson interferometer readout for cryogenic use. Change in calibration factor and drop in interferometer output ori…
▽ More
Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no commercial cryogenic accelerometers are available, we developed a compact self-calibrating accelerometer with a Michelson interferometer readout for cryogenic use. Change in calibration factor and drop in interferometer output originating from temperature drop were the main concerns which were tackled. Sensitivity of $3.38\times10^{-11}$ m/$\sqrt{\mathrm{Hz}}$ at 1 Hz was achieved at 300 K. The accelerometer was tested inside the KAGRA cryostat; showed stable operation down to 12 K in 0.1-100 Hz band with only 1% visibility drop. Our accelerometer can be employed in low vibration cryogenic environment for a multitude of applications.
△ Less
Submitted 19 March, 2022;
originally announced March 2022.
-
Vibration Analysis of KAGRA Cryostat at Cryogenic Temperature
Authors:
Rishabh Bajpai,
Takayuki Tomaru,
Nobuhiro Kimura,
Takafumi Ushiba,
Kazuhiro Yamamoto,
Toshikazu Suzuki,
Tohru Honda
Abstract:
KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration bel…
▽ More
KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration below 1 Hz is not impacted by cryocooler operation or structural resonances and follows ground motion. The noise floor of the shield in 1-100 Hz was observed to be 2-3 order of magnitude larger than seismic motion even without cryocooler operation. The operation of cryocoolers does not change the noise floor, but 2.0 Hz peaks and their harmonics were observed over the entire spectrum (1-100 Hz). These results were used to calculate the coupling of cooling system vibration to the test mass. We conclude that vibration from the cooling system does not limit KAGRA design sensitivity.
△ Less
Submitted 17 March, 2022;
originally announced March 2022.
-
Development and application of a $^3$He Neutron Spin Filter at J-PARC
Authors:
T. Okudaira,
T. Oku,
T. Ino,
H. Hayashida,
H. Kira,
K. Sakai,
K. Hiroi,
S. Takahashi,
K. Aizawa,
H. Endo,
S. Endo,
M. Hino,
K. Hirota,
T. Honda,
K. Ikeda,
K. Kakurai,
W. Kambara,
M. Kitaguchi,
T. Oda,
H. Ohshita,
T. Otomo,
H. M. Shimizu,
T. Shinohara,
J. Suzuki,
T. Yamamoto
Abstract:
We are developing a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long…
▽ More
We are developing a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing $^3$He cells, and compact pumping systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A $^3$He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110~W laser. Recently, the first user experiment utilizing the $^3$He spin filter was conducted, and there have been several more since then. The development and utilization of $^3$He spin filters at MLF of J-PARC are reported.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Label-free biochemical quantitative phase imaging with mid-infrared photothermal effect
Authors:
Miu Tamamitsu,
Keiichiro Toda,
Hiroyuki Shimada,
Takaaki Honda,
Masaharu Takarada,
Kohki Okabe,
Yu Nagashima,
Ryoichi Horisaki,
Takuro Ideguchi
Abstract:
Label-free optical imaging is valuable in biology and medicine with its non-destructive property and reduced optical and chemical damages. Quantitative phase (QPI) and molecular vibrational imaging (MVI) are the two most successful label-free methods, providing morphology and biochemistry, respectively, that have pioneered numerous applications along their independent technological maturity over t…
▽ More
Label-free optical imaging is valuable in biology and medicine with its non-destructive property and reduced optical and chemical damages. Quantitative phase (QPI) and molecular vibrational imaging (MVI) are the two most successful label-free methods, providing morphology and biochemistry, respectively, that have pioneered numerous applications along their independent technological maturity over the past few decades. However, the distinct label-free contrasts are inherently complementary and difficult to integrate due to the use of different light-matter interactions. Here, we present a unified imaging scheme that realizes simultaneous and in-situ acquisition of MV-fingerprint contrasts of single cells in the framework of QPI utilizing the mid-infrared photothermal effect. The fully label-free and robust integration of subcellular morphology and biochemistry would have important implications, especially for studying complex and fragile biological phenomena such as drug delivery, cellular diseases and stem cell development, where long-time observation of unperturbed cells are needed under low phototoxicity.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.