-
Measurement of the $^{40}$Ar(e,e$^{\prime}$) elastic scattering cross section with a novel gas-jet target
Authors:
M. Littich,
L. Doria,
P. Brand,
P. Achenbach,
S. Aulenbacher,
S. Bacca,
J. C. Bernauer,
M. Biroth,
D. Bonaventura,
D. Bosnar,
M. Christmann,
E. Cline,
A. Denig,
M. Distler,
A. Esser,
I. Friščić,
J. Geimer,
P. Gülker,
M. Hoek,
P. Klag,
A. Khoukaz,
M. Lauss,
S. Lunkenheimer,
T. Manoussos,
D. Markus
, et al. (13 additional authors not shown)
Abstract:
We report on a measurement of elastic electron scattering on argon performed with a novel cryogenic gas-jet target at the Mainz Microtron accelerator MAMI. The luminosity is estimated with the thermodynamical parameters of the target and by comparison to a calculation in distorted-wave Born approximation. The cross section, measured at new momentum transfers of 1.24 fm$^{-1}$ and 1.55 fm$^{-1}$ is…
▽ More
We report on a measurement of elastic electron scattering on argon performed with a novel cryogenic gas-jet target at the Mainz Microtron accelerator MAMI. The luminosity is estimated with the thermodynamical parameters of the target and by comparison to a calculation in distorted-wave Born approximation. The cross section, measured at new momentum transfers of 1.24 fm$^{-1}$ and 1.55 fm$^{-1}$ is in agreement with previous experiments performed with a traditional high-pressure gas target, as well as with modern ab-initio calculations employing state-of-the-art nuclear forces from chiral effective field theory. The nearly background-free measurement highlights the optimal properties of the gas-jet target for elements heavier than hydrogen, enabling new applications in hadron and nuclear physics.
△ Less
Submitted 20 March, 2025;
originally announced March 2025.
-
A Highly Segmented Neutron Polarimeter for A1
Authors:
R. Spreckels,
M. Hoek,
U. Müller,
M. Thiel
Abstract:
A new neutron polarimeter for measuring the neutron's electric form factor was designed and constructed to complement the A1 spectrometer setup at the Mainz Microtron (MAMI). The design is based on a previous polarimeter with significant improvements to halve the error of the extracted form factor. A higher granularity of the polarimeter sections and a deeper first section on the one hand, and a f…
▽ More
A new neutron polarimeter for measuring the neutron's electric form factor was designed and constructed to complement the A1 spectrometer setup at the Mainz Microtron (MAMI). The design is based on a previous polarimeter with significant improvements to halve the error of the extracted form factor. A higher granularity of the polarimeter sections and a deeper first section on the one hand, and a faster readout employing Time-over-Threshold methods to measure the signal amplitudes combined with a high-precision FPGA-based TDC on the other hand will allow to achieve this goal. The performance of the new polarimeter during a first measurement campaign in 2019 using liquid hydrogen and deuterium targets will be discussed.
△ Less
Submitted 11 August, 2023;
originally announced August 2023.
-
High accuracy synchrotron radiation interferometry with relativistic electrons
Authors:
P. Klag,
P. Achenbach,
T. Akiyama,
R. Böhm,
M. O. Distler,
L. Doria,
P. Eckert,
A. Esser,
J. Geratz,
T. Gogami,
C. Helmel,
P. Herrmann,
M Hoek,
M. Kaneta,
Y. Konishi,
R. Kino,
W. Lauth,
H. Merkel,
M. Mizuno,
U. Müller,
S. Nagao,
S. N. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme
, et al. (6 additional authors not shown)
Abstract:
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method…
▽ More
A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method will be applied. In this contribution the basic principle of this method is discussed and the analysis status of the measured synchrotron radiation spectra is presented
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
Systematic treatment of hypernuclear data and application to the hypertriton
Authors:
P. Eckert,
P. Achenbach,
M. Aragones Fontbote,
T. Akiyama,
M. O. Distler,
A. Esser,
J. Geratz,
M. Hoek,
K. Itabashi,
M. Kaneta,
R. Kino,
P. Klag,
H. Merkel,
M. Mizuno,
J. Müller,
U. Müller,
S. Nagao,
S. N. Nakamura,
Y. R. Nakamura,
K. Okuyama,
J. Pochodzalla,
B. S. Schlimme,
C. Sfienti,
R. Spreckels,
M. Steinen
, et al. (4 additional authors not shown)
Abstract:
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of th…
▽ More
A database is under construction to provide a complete collection of published basic properties of hypernuclei such as Λ binding energies, lifetimes, or excitation energies. From these values, averages with related errors are computed in a systematic way. For each property, the overall experimental situation is depicted in form of an ideogram showing the combined probability density function of the measurements. The database is accessible via a dynamic website at https://hypernuclei.kph.uni-mainz.de with an user interface offering customizable visualizations, selections, or unit conversions. The capabilities of the database are demonstrated for the puzzling and disputed data situation of the hypertriton.
△ Less
Submitted 7 January, 2022;
originally announced January 2022.
-
Operation and characterization of a windowless gas jet target in high-intensity electron beams
Authors:
B. S. Schlimme,
S. Aulenbacher,
P. Brand,
M. Littich,
Y. Wang,
P. Achenbach,
M. Ball,
J. C. Bernauer,
M. Biroth,
D. Bonaventura,
D. Bosnar,
S. Caiazza,
M. Christmann,
E. Cline,
A. Denig,
M. O. Distler,
L. Doria,
P. Eckert,
A. Esser,
I. Friščić,
S. Gagneur,
J. Geimer,
S. Grieser,
P. Gülker,
P. Herrmann
, et al. (32 additional authors not shown)
Abstract:
A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium, helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spect…
▽ More
A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium, helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a new generation of high-precision electron scattering experiments at high-intensity electron accelerators.
△ Less
Submitted 16 July, 2021; v1 submitted 27 April, 2021;
originally announced April 2021.
-
A Cleanroom in a Glovebox
Authors:
Mason J. Gray,
Narendra Kumar,
Ryan O'Connor,
Marcel Hoek,
Erin Sheridan,
Meaghan C. Doyle,
Marisa L. Romanelli,
Gavin B. Osterhoudt,
Yiping Wang,
Vincent Plisson,
Shiming Lei,
Ruidan Zhong,
Bryan Rachmilowitz,
He Zhao,
Hikari Kitadai,
Steven Shepard,
Leslie M. Schoop,
G. D. Gu,
Ilija Zeljkovic,
Xi Ling,
K. S. Burch
Abstract:
The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use t…
▽ More
The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system which allows for the fabrication and characterization of devices in an inert argon atmosphere. We demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Connection to a vacuum suitcase is also demonstrated to enable receiving from and transfer to various ultra-high vacuum (UHV) equipment including molecular-beam epitaxy (MBE) and scanning tunneling microscopy (STM).
△ Less
Submitted 27 July, 2020;
originally announced July 2020.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
The Innovative Design of the PANDA Barrel DIRC
Authors:
G. Schepers,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
C. Schwarz,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
F. Uhlig,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
K. Kreutzfeld,
J. Rieke,
M. Schmidt,
T. Wasem
, et al. (7 additional authors not shown)
Abstract:
The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test be…
▽ More
The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test beam campaigns at the CERN PS in 2017 and 2018 are discussed.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
The Barrel DIRC detector of PANDA
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
F. Uhlig,
S. Stelter,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
K. Kreutzfeld,
J. Rieke,
M. Schmidt,
T. Wasem
, et al. (7 additional authors not shown)
Abstract:
The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $α_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$Δ$p…
▽ More
The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $α_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$Δ$p/p = 4$\cdot10^{-5}$} allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between $22^\circ$ and $140^\circ$ and will achieve a pion-kaon separation of 3 standard deviations up to 3.5 GeV/$c$. Here, results of a test beam are shown for a single radiator bar coupled to a prism with $33^\circ$ opening angle, both made from synthetic fused silica read out with a photon detector array with 768 pixels.
△ Less
Submitted 24 January, 2019;
originally announced January 2019.
-
Halogen-Bond Driven Self-Assembly of Perfluorocarbon Monolayers
Authors:
Antonio Abate,
Raphael Dehmel,
Alessandro Sepe,
Ngoc Linh Nguyen,
Bart Roose,
Nicola Marzari,
Jun Ki Hong,
James M. Hook,
Ullrich Steiner,
Chiara Neto
Abstract:
The self-assembly of a single layer of organic molecules on a substrate is a powerful strategy to modify surfaces and interfacial properties. The detailed interplay of molecule-to-substrate and molecule-molecule interactions are crucial for the preparation of stable and uniform monomolecular coatings. Thiolates, silanes, phosphonates and carboxylates are widely used head-groups to link organic mol…
▽ More
The self-assembly of a single layer of organic molecules on a substrate is a powerful strategy to modify surfaces and interfacial properties. The detailed interplay of molecule-to-substrate and molecule-molecule interactions are crucial for the preparation of stable and uniform monomolecular coatings. Thiolates, silanes, phosphonates and carboxylates are widely used head-groups to link organic molecules to specific surfaces study we show that self-assembly of stable and highly compact monolayers of perfluorocarbons. Remarkably, the lowest ever reported surface energy of 2.6 mJ m-2 was measured for a perfluorododecyl iodide monolayer on a silicon nitride substrate. As a convenient, flexible and simple method, the self-assembly of halogen-bond driven perfluorocarbon monolayers is compatible with several applications, ranging from biosensing to electronics and microfluidics. Compared to other methods used to functionalise surfaces and interfaces, our procedure offers the unique advantage to work with extremely inert perfluorinated solvents. We demonstrate that surfaces commonly unstable in contact with many common organic solvents, such as organic-inorganic perovskites, can be functionalized via halogen bonding.
△ Less
Submitted 15 March, 2018;
originally announced March 2018.
-
The PANDA DIRC Detectors at FAIR
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
K. Goetzen,
G. Kalicy,
M. Krebs,
D. Lehmann,
F. Nerling,
M. Patsyuk,
K. Peters,
G. Schepers,
L. Schmitt,
J. Schwiening,
M. Traxler,
M. Zuehlsdorf,
M. Boehm,
A. Britting,
W. Eyrich,
A. Lehmann,
M. Pfaffinger,
F. Uhlig,
M. Dueren,
E. Etzelmueller
, et al. (17 additional authors not shown)
Abstract:
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22…
▽ More
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22 deg. to 140 deg. is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5 deg. (10 deg.) to 22 deg. in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Vertical Beam Polarization at MAMI
Authors:
B. S. Schlimme,
P. Achenbach,
K. Aulenbacher,
S. Baunack,
D. Bender,
J. Beričič,
D. Bosnar,
L. Correa,
M. Dehn,
M. O. Distler,
A. Esser,
H. Fonvieille,
I. Friščić,
B. Gutheil,
P. Herrmann,
M. Hoek,
S. Kegel,
Y. Kohl,
T. Kolar,
H. -J. Kreidel,
F. Maas,
H. Merkel,
M. Mihovilovič,
J. Müller,
U. Müller
, et al. (13 additional authors not shown)
Abstract:
For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orien…
▽ More
For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orientation was necessary to measure this asymmetry with the existing experimental setup. In this paper we describe the procedure to orient the electron polarization vector vertically, and the concept of determining both its magnitude and orientation with the available setup. A sophisticated method has been developed to overcome the lack of a polarimeter setup sensitive to the vertical polarization component.
△ Less
Submitted 18 January, 2017; v1 submitted 8 December, 2016;
originally announced December 2016.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
The prototype detection unit of the KM3NeT detector
Authors:
KM3NeT Collaboration,
S. Adrián-Martínez,
M. Ageron,
F. Aharonian,
S. Aiello,
A. Albert,
F. Ameli,
E. G. Anassontzis,
G. C. Androulakis,
M. Anghinolfi,
G. Anton,
S. Anvar,
M. Ardid,
T. Avgitas,
K. Balasi,
H. Band,
G. Barbarino,
E. Barbarito,
F. Barbato,
B. Baret,
S. Baron,
J. Barrios,
A. Belias,
E. Berbee,
A. M. van den Berg
, et al. (224 additional authors not shown)
Abstract:
A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitt…
▽ More
A prototype detection unit of the KM3NeT deep-sea neutrino telescope has been installed at 3500m depth 80km offshore the Italian coast. KM3NeT in its final configuration will contain several hundreds of detection units. Each detection unit is a mechanical structure anchored to the sea floor, held vertical by a submerged buoy and supporting optical modules for the detection of Cherenkov light emitted by charged secondary particles emerging from neutrino interactions. This prototype string implements three optical modules with 31 photomultiplier tubes each. These optical modules were developed by the KM3NeT Collaboration to enhance the detection capability of neutrino interactions. The prototype detection unit was operated since its deployment in May 2014 until its decommissioning in July 2015. Reconstruction of the particle trajectories from the data requires a nanosecond accuracy in the time calibration. A procedure for relative time calibration of the photomultiplier tubes contained in each optical module is described. This procedure is based on the measured coincidences produced in the sea by the 40K background light and can easily be expanded to a detector with several thousands of optical modules. The time offsets between the different optical modules are obtained using LED nanobeacons mounted inside them. A set of data corresponding to 600 hours of livetime was analysed. The results show good agreement with Monte Carlo simulations of the expected optical background and the signal from atmospheric muons. An almost background-free sample of muons was selected by filtering the time correlated signals on all the three optical modules. The zenith angle of the selected muons was reconstructed with a precision of about 3°.
△ Less
Submitted 23 December, 2015; v1 submitted 6 October, 2015;
originally announced October 2015.
-
Test of the CLAS12 RICH large scale prototype in the direct proximity focusing configuration
Authors:
N. Baltzell,
L. Barion,
F. Benmokhtar,
W. Brooks,
E. Cisbani,
M. Contalbrigo,
A. El Alaoui,
K. Hafidi,
M. Hoek,
V. Kubarovsky,
L. Lagamba,
V. Lucherini,
R. Malaguti,
M. Mirazita,
R. A. Montgomery,
A. Movsisyan,
P. Musico,
A. Orlandi,
D. Orecchini,
L. L. Pappalardo,
R. Perrino,
J. Phillips,
S. Pisano,
P. Rossi,
S. Squerzanti
, et al. (3 additional authors not shown)
Abstract:
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-pack…
▽ More
A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-packed and high-segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). We report here the results of the tests of a large scale prototype of the RICH detector performed with the hadron beam of the CERN T9 experimental hall for the direct detection configuration. The tests demonstrated that the proposed design provides the required pion-to-kaon rejection factor of 1:500 in the whole momentum range.
△ Less
Submitted 1 February, 2016; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Fast Frontend Electronics for high luminosity particle detectors
Authors:
M. Cardinali,
O. Corell,
M. I. Ferretti Bondy,
M. Hoek,
W. Lauth,
C. Rosner,
C. Sfienti,
M. Thiel
Abstract:
Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key requirement for electronics instrumentation, together with excellent timing resolution for precise event reconstruction. The development of dedicated FrontEnd Ele…
▽ More
Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key requirement for electronics instrumentation, together with excellent timing resolution for precise event reconstruction. The development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging. A current trend in R&D is towards multipurpose FEE which can be easily adapted to a great variety of detectors, without impairing the required high performance. We report on high-precision timing solutions which utilise high-bandwidth preamplifiers and fast discriminators providing Time-over-Threshold information, which can be used for charge measurements or walk corrections thus improving the obtainable timing resolution. The output signal are LVDS and can be directly fed into a multi-hit TDC readout. The performance of the electronics was investigated for single photon signals, typical for imaging Cherenkov detectors. The opposite condition of light signals arising from plastic scintillators, was also studied. High counting rates per channel of several MHz were achieved, and a timing resolution of better than 100 ps could be obtained in a test experiment using the full readout chain.
△ Less
Submitted 17 February, 2015;
originally announced February 2015.
-
Characterising encapsulated nuclear waste using cosmic-ray muon tomography
Authors:
Anthony Clarkson,
David J. Hamilton,
Matthias Hoek,
David G. Ireland,
John R. Johnstone,
Ralf Kaiser,
Tibor Keri,
Scott Lumsden,
David F. Mahon,
Bryan McKinnon,
Morgan Murray,
Siân Nutbeam-Tuffs,
Craig Shearer,
Guangliang Yang,
Colin Zimmerman
Abstract:
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons have been shown previously to successfully identify and characterise low- and high-Z materials within an air matrix using a prototype scintillating-fibre tracker system. Those studies were performed as the first in a series to assess the feasibility of this technology and image reconstruction techniques in characterisi…
▽ More
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons have been shown previously to successfully identify and characterise low- and high-Z materials within an air matrix using a prototype scintillating-fibre tracker system. Those studies were performed as the first in a series to assess the feasibility of this technology and image reconstruction techniques in characterising the potential high-Z contents of legacy nuclear waste containers for the UK Nuclear Industry. The present work continues the feasibility study and presents the first images reconstructed from experimental data collected using this small-scale prototype system of low- and high-Z materials encapsulated within a concrete-filled stainless-steel container. Clear discrimination is observed between the thick steel casing, the concrete matrix and the sample materials assayed. These reconstructed objects are presented and discussed in detail alongside the implications for future industrial scenarios.
△ Less
Submitted 27 October, 2014;
originally announced October 2014.
-
Investigation of Hamamatsu H8500 phototubes as single photon detectors
Authors:
M. Hoek,
V. Lucherini,
M. Mirazita,
R. A. Montgomery,
A. Orlandi,
S. Anefalos Pereira,
S. Pisano,
P. Rossi,
A. Viticchiè,
A. Witchger
Abstract:
We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility. For this, a laser working at 407.2nm wavelength was employed. The sample is divided equally into standard window…
▽ More
We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility. For this, a laser working at 407.2nm wavelength was employed. The sample is divided equally into standard window type, with a spectral response in the visible light region, and UV-enhanced window type MAPMTs. The studies confirm the suitability of these MAPMTs for single photon detection in such a Cherenkov imaging application.
△ Less
Submitted 24 March, 2015; v1 submitted 9 September, 2014;
originally announced September 2014.
-
Deep sea tests of a prototype of the KM3NeT digital optical module
Authors:
S. Adrián-Martínez,
M. Ageron,
F. Aharonian,
S. Aiello,
A. Albert,
F. Ameli,
E. G. Anassontzis,
M. Anghinolfi,
G. Anton,
S. Anvar,
M. Ardid,
R. de Asmundis,
K. Balasi,
H. Band,
G. Barbarino,
E. Barbarito,
F. Barbato,
B. Baret,
S. Baron,
A. Belias,
E. Berbee,
A. M. van den Berg,
A. Berkien,
V. Bertin,
S. Beurthey
, et al. (225 additional authors not shown)
Abstract:
The first prototype of a photo-detection unit of the future KM3NeT neutrino telescope has been deployed in the deep waters of the Mediterranean Sea. This digital optical module has a novel design with a very large photocathode area segmented by the use of 31 three inch photomultiplier tubes. It has been integrated in the ANTARES detector for in-situ testing and validation. This paper reports on th…
▽ More
The first prototype of a photo-detection unit of the future KM3NeT neutrino telescope has been deployed in the deep waters of the Mediterranean Sea. This digital optical module has a novel design with a very large photocathode area segmented by the use of 31 three inch photomultiplier tubes. It has been integrated in the ANTARES detector for in-situ testing and validation. This paper reports on the first months of data taking and rate measurements. The analysis results highlight the capabilities of the new module design in terms of background suppression and signal recognition. The directionality of the optical module enables the recognition of multiple Cherenkov photons from the same $^{40}$K decay and the localization bioluminescent activity in the neighbourhood. The single unit can cleanly identify atmospheric muons and provide sensitivity to the muon arrival directions.
△ Less
Submitted 16 May, 2014; v1 submitted 5 May, 2014;
originally announced May 2014.
-
The Design and Performance of a Scintillating-Fibre Tracker for the Cosmic-ray Muon Tomography of Legacy Nuclear Waste Containers
Authors:
Anthony Clarkson,
David J. Hamilton,
Matthias Hoek,
David G. Ireland,
Russell Johnstone,
Ralf Kaiser,
Tibor Keri,
Scott Lumsden,
David F. Mahon,
Bryan McKinnon,
Morgan Murray,
Sian Nutbeam-Tuffs,
Craig Shearer,
Cassie Staines,
Guangliang Yang,
Colin Zimmerman
Abstract:
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the characterisation of legacy nuclear waste materials stored within industrial containers. The design, assembly and performance of a prototype muon tomography system developed…
▽ More
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the characterisation of legacy nuclear waste materials stored within industrial containers. The design, assembly and performance of a prototype muon tomography system developed for this purpose are detailed in this work. This muon tracker comprises four detection modules, each containing orthogonal layers of Saint-Gobain BCF-10 2mm-pitch plastic scintillating fibres. Identification of the two struck fibres per module allows the reconstruction of the incoming and Coulomb-scattered muon trajectories. These allow the container content, with respect to the atomic number Z of the scattering material, to be determined through reconstruction of the scattering location and magnitude. On each detection layer, the light emitted by the fibre is detected by a single Hamamatsu H8500 MAPMT with two fibres coupled to each pixel via dedicated pairing schemes developed to ensure the identification of the struck fibre. The PMT signals are read out to QDCs. The design and assembly of the detector system are detailed and presented alongside results from performance studies with data collected after construction. These results reveal high stability during extended collection periods with detection efficiencies in the region of 80% per layer. Minor misalignments of millimetre order have been identified and corrected in software. A first image reconstructed from a test configuration of materials has been obtained using software based on the Maximum Likelihood Expectation Maximisation algorithm. The results highlight the high spatial resolution provided by the detector system. Clear discrimination between the low, medium and high-Z materials assayed is also observed.
△ Less
Submitted 7 October, 2013;
originally announced October 2013.
-
The HERMES Recoil Detector
Authors:
A. Airapetian,
E. C. Aschenauer,
S. Belostotski,
A. Borissov,
A. Borisenko,
J. Bowles,
I. Brodski,
V. Bryzgalov,
J. Burns,
G. P. Capitani,
V. Carassiti,
G. Ciullo,
A. Clarkson,
M. Contalbrigo,
R. De Leo,
E. De Sanctis,
M. Diefenthaler,
P. Di Nezza,
M. Düren,
M. Ehrenfried,
H. Guler,
I. M. Gregor,
M. Hartig,
G. Hill,
M. Hoek
, et al. (58 additional authors not shown)
Abstract:
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon.…
▽ More
For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1 T. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.
△ Less
Submitted 6 May, 2013; v1 submitted 25 February, 2013;
originally announced February 2013.
-
Technical Design Report for the: PANDA Micro Vertex Detector
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
M. Albrecht,
J. Becker,
K. Eickel,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Leyhe,
C. Motzko,
M. Pelizäus,
J. Pychy
, et al. (436 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics…
▽ More
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.
△ Less
Submitted 10 August, 2012; v1 submitted 27 July, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.