Skip to main content

Showing 1–18 of 18 results for author: Hirtl, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:2501.12797  [pdf, other

    physics.acc-ph physics.med-ph

    A double multi-turn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities

    Authors: Matthias Kausel, Claus Schmitzer, Andreas Gsponer, Markus Wolf, Hermann Fuchs, Felix Ulrich-Pur, Thomas Bergauer, Albert Hirtl, Nadia Gambino, Elisabeth Renner

    Abstract: The almost identical charge-to-mass ratios of fully ionized helium-4 and carbon-12 ions enable simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately three times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One p… ▽ More

    Submitted 22 January, 2025; originally announced January 2025.

    Comments: 14 pages, 12 figures

  2. arXiv:2412.11593  [pdf, other

    physics.med-ph physics.ins-det

    Exploring Offline Pileup Correction to Improve the Accuracy of Microdosimetric Characterization in Clinical Ion Beams

    Authors: Matthias Knopf, Sandra Barna, Daniel Radmanovac, Thomas Bergauer, Albert Hirtl, Giulio Magrin

    Abstract: Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorp… ▽ More

    Submitted 15 April, 2025; v1 submitted 16 December, 2024; originally announced December 2024.

    Comments: Revision prepared for submission to Physics in Medicine & Biology

  3. arXiv:2312.15027  [pdf, ps, other

    physics.med-ph physics.ins-det

    First experimental time-of-flight-based proton radiography using low gain avalanche diodes

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Tetyana Galatyuk, Albert Hirtl, Matthias Kausel, Vadym Kedych, Mladen Kis, Yevhen Kozymka, Wilhelm Krüger, Sergey Linev, Jan Michel, Jerzy Pietraszko, Adrian Rost, Christian Joachim Schmidt, Michael Träger, Michael Traxler

    Abstract: Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel… ▽ More

    Submitted 22 December, 2023; originally announced December 2023.

    Comments: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  4. arXiv:2209.13676  [pdf, other

    physics.med-ph physics.ins-det

    Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomo… ▽ More

    Submitted 27 September, 2022; originally announced September 2022.

  5. Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters, Simon Rit

    Abstract: For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed t… ▽ More

    Submitted 10 September, 2021; originally announced September 2021.

    Comments: Preprint submitted to Physics in Medicine and Biology. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  6. A Proton Computed Tomography Demonstrator for Stopping Power Measurements

    Authors: Felix Ulrich-Pur, Thomas Bergauer, Alexander Burker, Albert Hirtl, Christian Irmler, Stefanie Kaser, Florian Pitters

    Abstract: Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system… ▽ More

    Submitted 24 June, 2021; originally announced June 2021.

    Comments: Preprint submitted to the open-access Journal of Physics: Conference Series. (TIPP2021 conference proceedings). IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it

  7. arXiv:2102.06240  [pdf, other

    physics.acc-ph physics.med-ph

    Commissioning of low particle flux for proton beams at MedAustron

    Authors: Felix Ulrich-Pur, Laurids Adler, Thomas Bergauer, Alexander Burker, Andrea De Franco, Greta Guidoboni, Albert Hirtl, Christian Irmler, Stefanie Kaser, Sebastian Nowak, Florian Pitters, Mauro Pivi, Dale Prokopovich, Claus Schmitzer, Alexander Wastl

    Abstract: MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This r… ▽ More

    Submitted 27 May, 2021; v1 submitted 11 February, 2021; originally announced February 2021.

    Comments: Preprint submitted to NIM A (first revision)

  8. arXiv:2008.08422  [pdf, other

    physics.med-ph physics.ins-det

    Single particle tracking uncertainties in ion imaging

    Authors: A. Burker, T. Bergauer, A. Hirtl, C. Irmler, S. Kaser, B. Knäusl, F. Pitters, F. Ulrich-Pur

    Abstract: An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a… ▽ More

    Submitted 22 February, 2021; v1 submitted 19 August, 2020; originally announced August 2020.

    Comments: 19 pages, 6 figures, submitted to Phys. Med. Biol

  9. arXiv:2003.00115  [pdf, other

    physics.ins-det physics.med-ph

    Imaging with protons at MedAustron

    Authors: F. Ulrich-Pur, T. Bergauer, A. Burker, S. Hatamikia, A. Hirtl, C. Irmler, S. Kaser, P. Paulitsch, F. Pitters, V. Teufelhart

    Abstract: Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sourc… ▽ More

    Submitted 15 July, 2020; v1 submitted 28 February, 2020; originally announced March 2020.

    Comments: 7 pages, 11 figures, proceedings of the "HSTD12: 12th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (HSTD12)", 14-18 Dec 2019, Hiroshima (Japan), to be submitted to Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

  10. arXiv:1709.05950  [pdf, other

    physics.atom-ph nucl-ex

    Line shape analysis of the K$β$ transition in muonic hydrogen

    Authors: D. S. Covita, D. F. Anagnostopoulos, H. Fuhrmann, H. Gorke, D. Gotta, A. Gruber, A. Hirtl, T. Ishiwatari, P. Indelicato, T. S. Jensen, E. -O. Le Bigot, V. E. Markushin, M. Nekipelov, V. N. Pomerantsev, V. P. Popov, J. M. F. dos Santos, Ph. Schmid, L. M. Simons, M. Theisen, M. Trassinelli, J. F. C. A. Veloso, J. Zmeskal

    Abstract: The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and… ▽ More

    Submitted 5 April, 2018; v1 submitted 18 September, 2017; originally announced September 2017.

    Comments: 22 pages, 21 figures

  11. arXiv:1406.6525  [pdf, other

    nucl-ex physics.atom-ph

    Hadronic shift in pionic hydrogen

    Authors: M. Hennebach, D. F. Anagnostopoulos, A. Dax, H. Fuhrmann, D. Gotta, A. Gruber, A. Hirtl, P. Indelicato, Y. -W. Liu, B. Manil, V. E. Markushin, A. J. Rusi el Hassani, L. M. Simons, M. Trassinelli, J. Zmeskal

    Abstract: The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent… ▽ More

    Submitted 17 December, 2014; v1 submitted 25 June, 2014; originally announced June 2014.

    Comments: 10 pages, 6 figures

  12. arXiv:1305.6257  [pdf, other

    physics.ins-det physics.med-ph

    Studies on the Cherenkov Effect for Improved Time Resolution of TOF-PET

    Authors: S. E. Brunner, L. Gruber, J. Marton, K. Suzuki, A. Hirtl

    Abstract: With the newly gained interest in the time of flight method for positron emission tomography (TOF-PET), many options for pushing the time resolution to its borders have been investigated. As one of these options the exploitation of the Cherenkov effect has been proposed, since it allows to bypass the scintillation process and therefore provides almost instantaneous response to incident 511keV anni… ▽ More

    Submitted 19 November, 2013; v1 submitted 27 May, 2013; originally announced May 2013.

  13. New Approaches for Improvement of TOF-PET

    Authors: Stefan E. Brunner, Lukas Gruber, Johann Marton, Ken Suzuki, Albert Hirtl

    Abstract: We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and i… ▽ More

    Submitted 8 May, 2013; v1 submitted 7 May, 2013; originally announced May 2013.

  14. Line shape of the muH(3p - 1s) hyperfine transitions

    Authors: D. S. Covita, D. F. Anagnostopoulos, H. Gorke, D. Gotta, A. Gruber, A. Hirtl, T. Ishiwatari, P. Indelicato, E. -O. LeBigot, M. Nekipelov, J. M. F. dos Santos, Ph. Schmid, L. M. Simons, M. Trassinelli, J. F. C. A. Veloso, J. Zmeskal

    Abstract: The (3p - 1s) X-ray transition to the muonic hydrogen ground state was measured with a high resolution crystal spectrometer. A Doppler effect broadening of the X-ray line was established which could be attributed to different Coulomb de-excitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was di… ▽ More

    Submitted 10 October, 2008; v1 submitted 9 October, 2008; originally announced October 2008.

    Comments: Submitted to Physical Review Letters

  15. Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources

    Authors: Paul Indelicato, S. Boucard, D. S. Covita, D. Gotta, A. Gruber, A. Hirtl, H. Fuhrmann, E. -O. Le Bigot, S. Schlesser, J. M. F. Dos Santos, L. M. Simons, L. Stingelin, M. Trassinelli, J. Veloso, A. Wasser, J. Zmeskal

    Abstract: Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho… ▽ More

    Submitted 28 October, 2006; originally announced October 2006.

  16. arXiv:physics/0410250  [pdf, ps, other

    physics.atom-ph

    High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT

    Authors: Martino Trassinelli, Sandor Biri, Stephane Boucard, Daniel S. Covita, Detlev Gotta, Bruno Leoni, Albert Hirtl, Paul Indelicato, Eric-Olivier Le Bigot, Joaquim M. F. Dos Santos, Leopold M. Simons, Lucas Stingelin, Joao F. C. A. Veloso, Alfred Wasser, Johann Zmeskal

    Abstract: We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct… ▽ More

    Submitted 26 October, 2004; originally announced October 2004.

    Journal ref: ECR Ion Sources 2004, Etats-Unis d'Amerique (2004)

  17. arXiv:nucl-th/0310027  [pdf, ps, other

    nucl-th hep-ph physics.atom-ph

    Energy level displacement of the excited nl state of pionic hydrogen

    Authors: A. N. Ivanov, M. Faber, A. Hirtl, J. Marton, N. I. Troitskaya

    Abstract: The energy level displacements of the excited nl states of pionic hydrogen and the contribution of the ns -> 1s transitions and the (pi^-p)_Coul -> 1s transitions of the pi^-p pair, coupled by the attractive Coulomb field in the S-wave state with a continuous energy spectrum, to the shift of the energy level of the ground state of pionic hydrogen, caused by strong low-energy interactions, are ca… ▽ More

    Submitted 24 November, 2003; v1 submitted 8 October, 2003; originally announced October 2003.

    Comments: 18 pages, no figures, latex, text is revised, references are added

    Journal ref: Eur.Phys.J.A19:413-422,2004

  18. arXiv:nucl-th/0306047  [pdf, ps, other

    nucl-th hep-ex hep-ph nucl-ex physics.atom-ph

    On pionic hydrogen. Quantum field theoretic, relativistic covariant and model-independent approach

    Authors: A. N. Ivanov, M. Faber, A. Hirtl, J. Marton, N. I. Troitskaya

    Abstract: We consider pionic hydrogen A_(pi p), the bound pi^- p state. Within the quantum field theoretic and relativistic covariant approach we calculate the shift and width of the energy level of the ground state of pionic hydrogen caused by strong low-energy interactions treated perturbatively. The generalization of the Deser-Goldberger-Baumann-Thirring (DGBT) formulas (Phys. Rev. 96, 774 (1954)) is g… ▽ More

    Submitted 20 November, 2003; v1 submitted 17 June, 2003; originally announced June 2003.

    Comments: 24 pages, latex, no figures, corrected according to the version accepted for publication in EPJA

    Journal ref: Eur.Phys.J.A18:653-666,2003