The XOC X-ray Beamline: Probing Colder, Quieter, and Softer
Authors:
Haley R. Stueber,
Tanmoy Chattopadhyay,
Sven C. Herrmann,
Peter Orel,
Tsion Gebre,
Aanand Joshi,
Steven W. Allen,
Glenn Morris,
Artem Poliszczuk
Abstract:
Future strategic X-ray satellite telescopes, such as the probe-class Advanced X-ray Imaging Satellite (AXIS), will require excellent soft energy response in their imaging detectors to enable maximum discovery potential. In order to characterize Charge-Coupled Device (CCD) and Single Electron Sensitive Read Output (SiSeRO) detectors in the soft X-ray region, the X-ray Astronomy and Observational Co…
▽ More
Future strategic X-ray satellite telescopes, such as the probe-class Advanced X-ray Imaging Satellite (AXIS), will require excellent soft energy response in their imaging detectors to enable maximum discovery potential. In order to characterize Charge-Coupled Device (CCD) and Single Electron Sensitive Read Output (SiSeRO) detectors in the soft X-ray region, the X-ray Astronomy and Observational Cosmology (XOC) group at Stanford has developed, assembled, and commissioned a 2.5-meter-long X-ray beamline test system. The beamline is designed to efficiently produce monoenergetic X-ray fluorescence lines in the 0.3-10 keV energy range and achieve detector temperatures as low as 173 K. We present design and simulation details of the beamline, and discuss the vacuum, cooling, and X-ray fluorescence performance achieved. As a workhorse for future detector characterization at Stanford, the XOC beamline will support detector development for a broad range of X-ray astronomy instruments.
△ Less
Submitted 23 July, 2024;
originally announced July 2024.
Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation
Authors:
Andreas Koch,
Matthew Hart,
Tim Nicholls,
Christian Angelsen,
John Coughlan,
Marcus French,
Steffen Hauf,
Markus Kuster,
Jolanta Sztuk-Dambietz,
Monica Turcato,
Gabriella A. Carini,
Matthieu Chollet,
Sven C. Herrmann,
Henrik T. Lemke,
Silke Nelson,
Sanghoon Song,
Matt Weaver,
Diling Zhu,
Alke Meents,
Pontus Fischer
Abstract:
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides…
▽ More
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.
△ Less
Submitted 7 November, 2013;
originally announced November 2013.