-
The LiteBIRD mission to explore cosmic inflation
Authors:
T. Ghigna,
A. Adler,
K. Aizawa,
H. Akamatsu,
R. Akizawa,
E. Allys,
A. Anand,
J. Aumont,
J. Austermann,
S. Azzoni,
C. Baccigalupi,
M. Ballardini,
A. J. Banday,
R. B. Barreiro,
N. Bartolo,
S. Basak,
A. Basyrov,
S. Beckman,
M. Bersanelli,
M. Bortolami,
F. Bouchet,
T. Brinckmann,
P. Campeti,
E. Carinos,
A. Carones
, et al. (134 additional authors not shown)
Abstract:
LiteBIRD, the next-generation cosmic microwave background (CMB) experiment, aims for a launch in Japan's fiscal year 2032, marking a major advancement in the exploration of primordial cosmology and fundamental physics. Orbiting the Sun-Earth Lagrangian point L2, this JAXA-led strategic L-class mission will conduct a comprehensive mapping of the CMB polarization across the entire sky. During its 3-…
▽ More
LiteBIRD, the next-generation cosmic microwave background (CMB) experiment, aims for a launch in Japan's fiscal year 2032, marking a major advancement in the exploration of primordial cosmology and fundamental physics. Orbiting the Sun-Earth Lagrangian point L2, this JAXA-led strategic L-class mission will conduct a comprehensive mapping of the CMB polarization across the entire sky. During its 3-year mission, LiteBIRD will employ three telescopes within 15 unique frequency bands (ranging from 34 through 448 GHz), targeting a sensitivity of 2.2\,$μ$K-arcmin and a resolution of 0.5$^\circ$ at 100\,GHz. Its primary goal is to measure the tensor-to-scalar ratio $r$ with an uncertainty $δr = 0.001$, including systematic errors and margin. If $r \geq 0.01$, LiteBIRD expects to achieve a $>5σ$ detection in the $\ell=$2-10 and $\ell=$11-200 ranges separately, providing crucial insight into the early Universe. We describe LiteBIRD's scientific objectives, the application of systems engineering to mission requirements, the anticipated scientific impact, and the operations and scanning strategies vital to minimizing systematic effects. We will also highlight LiteBIRD's synergies with concurrent CMB projects.
△ Less
Submitted 4 June, 2024;
originally announced June 2024.
-
Development of the Low Frequency Telescope focal plane detector arrays for LiteBIRD
Authors:
Tommaso Ghigna,
Aritoki Suzuki,
Benjamin Westbrook,
Christopher Raum,
Hiroki Akamatsu,
Shawn Beckman,
Nicole Farias,
Tijmen de Haan,
Nils Halverson,
Masashi Hazumi,
Johannes Hubmayr,
Greg Jaehnig,
Adrian T. Lee,
Samantha L. Stever,
Yu Zhou
Abstract:
LiteBIRD, a forthcoming JAXA mission, aims to accurately study the microwave sky within the 40-400 GHz frequency range divided into 15 distinct nominal bands. The primary objective is to constrain the CMB inflationary signal, specifically the primordial B-modes. LiteBIRD targets the CMB B-mode signal on large angular scales, where the primordial inflationary signal is expected to dominate, with th…
▽ More
LiteBIRD, a forthcoming JAXA mission, aims to accurately study the microwave sky within the 40-400 GHz frequency range divided into 15 distinct nominal bands. The primary objective is to constrain the CMB inflationary signal, specifically the primordial B-modes. LiteBIRD targets the CMB B-mode signal on large angular scales, where the primordial inflationary signal is expected to dominate, with the goal of reaching a tensor-to-scalar ratio sensitivity of $σ_r\sim0.001$. LiteBIRD frequency bands will be split among three telescopes, with some overlap between telescopes for better control of systematic effects. Here we report on the development status of the detector arrays for the Low Frequency Telescope (LFT), which spans the 34-161 GHz range, with 12 bands subdivided between four types of trichroic pixels consisting of lenslet-coupled sinuous antennas. The signal from the antenna is bandpass filtered and sensed by AlMn Transition-Edge Sensors (TES). We provide an update on the status of the design and development of LiteBIRD's LFT LF1 (40-60-78 GHz), LF2 (50-68-89 GHz) pixels. We discuss design choices motivated by LiteBIRD scientific goals. In particular we focus on the details of the optimization of the design parameters of the sinuous antenna, on-chip bandpass filters, cross-under and impedance transformers and all the RF components that define the LF1 and LF2 pixel detection chain. We present this work in the context of the technical challenges and physical constraints imposed by the finite size of the instrument.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
A Method of Measuring TES Complex ETF Response in Frequency-domain Multiplexed Readout by Single Sideband Power Modulation
Authors:
Yu Zhou,
Tijmen de Haan,
Hiroki Akamatsu,
Daisuke Kaneko,
Masashi Hazumi,
Masaya Hasegawa,
Aritoki Suzuki,
Adrian T. Lee
Abstract:
The digital frequency domain multiplexing (DfMux) technique is widely used for astrophysical instruments with large detector arrays. Detailed detector characterization is required for instrument calibration and systematics control. We conduct the TES complex electrothermal-feedback (ETF) response measurement with the DfMux readout system as follows. By injecting a single sideband signal, we induce…
▽ More
The digital frequency domain multiplexing (DfMux) technique is widely used for astrophysical instruments with large detector arrays. Detailed detector characterization is required for instrument calibration and systematics control. We conduct the TES complex electrothermal-feedback (ETF) response measurement with the DfMux readout system as follows. By injecting a single sideband signal, we induce modulation in TES power dissipation over a frequency range encompassing the detector response. The modulated current signal induced by TES heating effect is measured, allowing for the ETF response characterization of the detector. With the injection of an upper sideband, the TES readout current shows both an upper and a lower sideband. We model the upper and lower sideband complex ETF response and verify the model by fitting to experimental data. The model not only can fit for certain physical parameters of the detector, such as loop gain, temperature sensitivity, current sensitivity, and time constant, but also enables us to estimate the systematic effect introduced by the multiplexed readout. The method is therefore useful for in-situ detector calibration and for estimating systematic effects during astronomical telescope observations, such as those performed by the upcoming LiteBIRD satellite.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
Simulations of systematic effects arising from cosmic rays in the LiteBIRD space telescope, and effects on the measurements of CMB $B$-modes
Authors:
Samantha Lynn Stever,
Tommaso Ghigna,
Mayu Tominaga,
Giuseppe Puglisi,
Masahiro Tsujimoto,
Matteo Zeccoli Marazzini,
Matteo Baratto,
Maurizio Tomasi,
Yuto Minami,
Shinya Sugiyama,
Akihiro Kato,
Tomotake Matsumura,
Hirokazu Ishino,
Guillaume Patanchon,
Masashi Hazumi
Abstract:
Systematic effects arising from cosmic rays have been shown to be a significant threat to space telescopes using high-sensitivity bolometers. The LiteBIRD space mission aims to measure the polarised Cosmic Microwave Background with unprecedented sensitivity, but its positioning in space will also render it susceptible to cosmic ray effects. We present an end-to-end simulator for evaluating the exp…
▽ More
Systematic effects arising from cosmic rays have been shown to be a significant threat to space telescopes using high-sensitivity bolometers. The LiteBIRD space mission aims to measure the polarised Cosmic Microwave Background with unprecedented sensitivity, but its positioning in space will also render it susceptible to cosmic ray effects. We present an end-to-end simulator for evaluating the expected scale of cosmic ray effect on the LiteBIRD space mission, which we demonstrate on a subset of detectors on the 166 GHz band of the Low Frequency Telescope. The simulator couples the expected proton flux at L2 with a model of the thermal response of the LFT focal plane and the electrothermal response of its superconducting detectors, producing time-ordered data which is projected into simulated sky maps and subsequent angular power spectra.
△ Less
Submitted 29 June, 2021;
originally announced July 2021.
-
Design of a testbed for the study of system interference in space CMB polarimetry
Authors:
Tommaso Ghigna,
Tomotake Matsumura,
Masashi Hazumi,
Samantha Lynn Stever,
Yuki Sakurai,
Nobuhiko Katayama,
Aritoki Suzuki,
Benjamin Westbrook,
Adrian Lee
Abstract:
LiteBIRD is a proposed JAXA satellite mission to measure the CMB B-mode polarization with unprecedented sensitivity ($σ_r\sim 0.001$). To achieve this goal, $4676$ state-of-the-art TES bolometers will observe the whole sky for 3 years from L2. These detectors, as well as the SQUID readout, are extremely susceptible to EMI and other instrumental disturbances e.g. static magnetic field and vibration…
▽ More
LiteBIRD is a proposed JAXA satellite mission to measure the CMB B-mode polarization with unprecedented sensitivity ($σ_r\sim 0.001$). To achieve this goal, $4676$ state-of-the-art TES bolometers will observe the whole sky for 3 years from L2. These detectors, as well as the SQUID readout, are extremely susceptible to EMI and other instrumental disturbances e.g. static magnetic field and vibration. As a result, careful analysis of the interference between the detector system and the rest of the telescope instruments is essential. This study is particularly important during the early phase of the project, in order to address potential problems before the final assembly of the whole instrument. We report our plan for the preparation of a cryogenic testbed to study the interaction between the detectors and other subsystems, especially a polarization modulator unit consisting of a magnetically-rotating half wave plate. We also present the requirements, current status and preliminary results.
△ Less
Submitted 26 November, 2019;
originally announced November 2019.
-
Measurements of tropospheric ice clouds with a ground-based CMB polarization experiment, POLARBEAR
Authors:
Satoru Takakura,
Mario A. O. Aguilar-Faúndez,
Yoshiki Akiba,
Kam Arnold,
Carlo Baccigalupi,
Darcy Barron,
Dominic Beck,
Federico Bianchini,
David Boettger,
Julian Borrill,
Kolen Cheung,
Yuji Chinone,
Tucker Elleflot,
Josquin Errard,
Giulio Fabbian,
Chang Feng,
Neil Goeckner-Wald,
Takaho Hamada,
Masaya Hasegawa,
Masashi Hazumi,
Logan Howe,
Daisuke Kaneko,
Nobuhiko Katayama,
Brian Keating,
Reijo Keskitalo
, et al. (23 additional authors not shown)
Abstract:
The polarization of the atmosphere has been a long-standing concern for ground-based experiments targeting cosmic microwave background (CMB) polarization. Ice crystals in upper tropospheric clouds scatter thermal radiation from the ground and produce a horizontally-polarized signal. We report the detailed analysis of the cloud signal using a ground-based CMB experiment, POLARBEAR, located at the A…
▽ More
The polarization of the atmosphere has been a long-standing concern for ground-based experiments targeting cosmic microwave background (CMB) polarization. Ice crystals in upper tropospheric clouds scatter thermal radiation from the ground and produce a horizontally-polarized signal. We report the detailed analysis of the cloud signal using a ground-based CMB experiment, POLARBEAR, located at the Atacama desert in Chile and observing at 150 GHz. We observe horizontally-polarized temporal increases of low-frequency fluctuations ("polarized bursts," hereafter) of $\lesssim$0.1 K when clouds appear in a webcam monitoring the telescope and the sky. The hypothesis of no correlation between polarized bursts and clouds is rejected with $>$24$σ$ statistical significance using three years of data. We consider many other possibilities including instrumental and environmental effects, and find no other reasons other than clouds that can explain the data better. We also discuss the impact of the cloud polarization on future ground-based CMB polarization experiments.
△ Less
Submitted 18 September, 2018;
originally announced September 2018.
-
Performance of a continuously rotating half-wave plate on the POLARBEAR telescope
Authors:
Satoru Takakura,
Mario Aguilar,
Yoshiki Akiba,
Kam Arnold,
Carlo Baccigalupi,
Darcy Barron,
Shawn Beckman,
David Boettger,
Julian Borrill,
Scott Chapman,
Yuji Chinone,
Ari Cukierman,
Anne Ducout,
Tucker Elleflot,
Josquin Errard,
Giulio Fabbian,
Takuro Fujino,
Nicholas Galitzki,
Neil Goeckner-Wald,
Nils W. Halverson,
Masaya Hasegawa,
Kaori Hattori,
Masashi Hazumi,
Charles Hill,
Logan Howe
, et al. (28 additional authors not shown)
Abstract:
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector…
▽ More
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $\sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{\rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{\rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($\ell \sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.
△ Less
Submitted 27 May, 2017; v1 submitted 23 February, 2017;
originally announced February 2017.
-
Millimeter-Wave Broadband Anti-Reflection Coatings Using Laser Ablation of Sub-Wavelength Structures
Authors:
Tomotake Matsumura,
Karl Young,
Qi Wen,
Shaul Hanany,
Hirokazu Ishino,
Yuki Inoue,
Masashi Hazumi,
Jürgen Koch,
Oliver Suttman,
Viktor Schütz
Abstract:
We report on the first use of laser ablation to make sub-millimeter, broad-band, anti-reflection coatings (ARC) based on sub-wavelength structures (SWS) on alumina and sapphire. We used a 515 nm laser to produce pyramid-shaped structures with pitch of about 320 $μ$m and total height of near 800 $μ$m. Transmission measurements between 70 and 140 GHz are in agreement with simulations using electroma…
▽ More
We report on the first use of laser ablation to make sub-millimeter, broad-band, anti-reflection coatings (ARC) based on sub-wavelength structures (SWS) on alumina and sapphire. We used a 515 nm laser to produce pyramid-shaped structures with pitch of about 320 $μ$m and total height of near 800 $μ$m. Transmission measurements between 70 and 140 GHz are in agreement with simulations using electromagnetic propagation software. The simulations indicate that SWS ARC with the fabricated shape should have a fractional bandwidth response of $Δν/ ν_{center}\ = 0.55$ centered on 235 GHz for which reflections are below 3%. Extension of the bandwidth to both lower and higher frequencies, between few tens of GHz and few THz, should be straightforward with appropriate adjustment of laser ablation parameters.
△ Less
Submitted 30 March, 2016; v1 submitted 29 January, 2016;
originally announced January 2016.
-
Development of readout electronics for POLARBEAR-2 Cosmic Microwave Background experiment
Authors:
K. Hattori,
Y. Akiba,
K. Arnold,
D. Barron,
A. N. Bender,
A. Cukierman,
T. de Haan,
M. Dobbs,
T. Elleflot,
M. Hasegawa,
M. Hazumi,
W. Holzapfel,
Y. Hori,
B. Keating,
A. Kusaka,
A. Lee,
J. Montgomery,
K. Rotermund,
I. Shirley,
A. Suzuki,
N. Whitehorn
Abstract:
The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large arrays, we have been developing a readout system with a multiplexing factor of 40 in the frequency domain. Extending that architecture to 40 bolometers requires an increase…
▽ More
The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large arrays, we have been developing a readout system with a multiplexing factor of 40 in the frequency domain. Extending that architecture to 40 bolometers requires an increase in the bandwidth of the SQUID electronics above 4 MHz. This paper focuses on cryogenic readout and shows how it affects cross talk and the responsivity of the TES bolometers. A series resistance, such as equivalent series resistance (ESR) of capacitors for LC filters, leads to non-linear response of the bolometers. A wiring inductance modulates a voltage across the bolometers and causes cross talk. They should be controlled well to reduce systematic errors in CMB observations. We have been developing a cryogenic readout with a low series impedance and have tuned bolometers in the middle of their transition at a high frequency (> 3 MHz).
△ Less
Submitted 23 December, 2015;
originally announced December 2015.
-
Development FD-SOI MOSFET amplifiers for integrated read-out circuit of superconducting-tunnel-junction single-photon-detectors
Authors:
Kenji Kiuchi,
Shinhong Kim,
Yuji Takeuchi,
Kenichi Takemasa,
Kazuki Nagata,
Kota Kasahara,
Koya Moriuchi,
Ren Senzaki,
Shunsuke Yagi,
Hirokazu Ikeda,
Shuji Matsuura,
Takehiko Wada,
Hirokazu Ishino,
Atsuko Kibayashi,
Hiromi Sato,
Satoru Mima,
Takuo Yoshida,
Ryuta Hirose,
Yukihiro Kato,
Masasi Hazumi,
Yasuo Arai,
Ikuo Kurachi,
Erik Ramgerg,
Mark Kozlovsky,
Paul Rubinov
, et al. (6 additional authors not shown)
Abstract:
We proposed a new high resolution single photon infrared spectrometer for search for radiative decay of cosmic neutrino background(C$ν$B). The superconducting-tunnel-junctions(STJs) are used as a single photoncounting device. Each STJ consists of Nb/Al/Al${}_{\mathrm{x}}$O${}_{\mathrm{y}}$/Al/Nb layers and their thicknesses are optimized for the operation temperature at 370 mK cooled by a…
▽ More
We proposed a new high resolution single photon infrared spectrometer for search for radiative decay of cosmic neutrino background(C$ν$B). The superconducting-tunnel-junctions(STJs) are used as a single photoncounting device. Each STJ consists of Nb/Al/Al${}_{\mathrm{x}}$O${}_{\mathrm{y}}$/Al/Nb layers and their thicknesses are optimized for the operation temperature at 370 mK cooled by a ${}^{3}$He sorption refrigerator. Our STJs achieved the leak current 250 pA and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio(S/N). FD-SOI MOSFETs can be operated at cryogenic temperature of 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a non linear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors are 0.4 mV and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp required to have a fast response(GBW$\geq$100 MHz) and it must have low power dissipation as compared to the cooling power of refrigerator.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Adaptation of frequency-domain readout for Transition Edge Sensor bolometers for the POLARBEAR-2 Cosmic Microwave Background experiment
Authors:
Kaori Hattori,
Kam Arnold,
Darcy Barron,
Matt Dobbs,
Tijmen de Haan,
Nicholas Harrington,
Masaya Hasegawa,
Masashi Hazumi,
William L. Holzapfel,
Brian Keating,
Adrian T. Lee,
Hideki Morii,
Michael J. Myers,
Graeme Smecher,
Aritoki Suzuki,
Takayuki Tomaru
Abstract:
The POLARBEAR-2 CosmicMicrowave Background (CMB) experiment aims to observe B-mode polarization with high sensitivity to explore gravitational lensing of CMB and inflationary gravitational waves. POLARBEAR-2 is an upgraded experiment based on POLARBEAR-1, which had first light in January 2012. For POLARBEAR-2, we will build a receiver that has 7,588 Transition Edge Sensor (TES) bolometers coupled…
▽ More
The POLARBEAR-2 CosmicMicrowave Background (CMB) experiment aims to observe B-mode polarization with high sensitivity to explore gravitational lensing of CMB and inflationary gravitational waves. POLARBEAR-2 is an upgraded experiment based on POLARBEAR-1, which had first light in January 2012. For POLARBEAR-2, we will build a receiver that has 7,588 Transition Edge Sensor (TES) bolometers coupled to two-band (95 and 150 GHz) polarization-sensitive antennas. For the large array's readout, we employ digital frequency-domain multiplexing and multiplex 32 bolometers through a single superconducting quantum interference device (SQUID). An 8-bolometer frequency-domain multiplexing readout has been deployed on POLARBEAR-1 experiment. Extending that architecture to 32 bolometers requires an increase in the bandwidth of the SQUID electronics to 3 MHz. To achieve this increase in bandwidth, we use Digital Active Nulling (DAN) on the digital frequency multiplexing platform. In this paper, we present requirements and improvements on parasitic inductance and resistance of cryogenic wiring and capacitors used for modulating bolometers. These components are problematic above 1 MHz. We also show that our system is able to bias a bolometer in its superconducting transition at 3 MHz.
△ Less
Submitted 4 July, 2013; v1 submitted 7 June, 2013;
originally announced June 2013.
-
Innovative Demodulation Scheme for Coherent Detectors in CMB Experiments
Authors:
K. Ishidoshiro,
Y. Chinone,
M. Hasegawa,
M. Hazumi,
M. Nagai,
O. Tajima
Abstract:
We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which…
▽ More
We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two- point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.
△ Less
Submitted 21 May, 2012; v1 submitted 12 March, 2012;
originally announced March 2012.
-
Readout system with on-board demodulation for CMB polarization experiments using coherent polarimeter arrays
Authors:
Koji Ishidoshiro,
Makoto Nagai,
Takeo Higuchi,
Masaya Hasegawa,
Masashi Hazumi,
Masahiro Ikeno,
Osamu Tajima,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
B-modes are special patterns in cosmic microwave background (CMB) polarization. The detection of them is a smoking-gun signature of primordial gravitational waves. The generic strategy of the CMB polarization experiments is to employ a large number of polarimeters for improving the statistics. The Q/U Imaging ExperimenT-II (QUIET-II) has been proposed to detect the B-modes using the world's larges…
▽ More
B-modes are special patterns in cosmic microwave background (CMB) polarization. The detection of them is a smoking-gun signature of primordial gravitational waves. The generic strategy of the CMB polarization experiments is to employ a large number of polarimeters for improving the statistics. The Q/U Imaging ExperimenT-II (QUIET-II) has been proposed to detect the B-modes using the world's largest coherent polarimeter array (2,000 channels). An unique detection technique using QUIET's polarimeters, which is a modula- tion/demodulation scheme, enables us directly extracting the polarization signal. The extracted signal is free from non- polarized components and intrinsic 1/f noise. We developed a data readout system with on-board demodulation functions for the QUIET-II experiment. We employed a "master" clock strategy. This strategy guarantees phase matching between the modulation by the polarimeters and the demodulation by ADC modules. The single master generates all carrier clocks and distributes them to each module. The developed electronics, clock modules, and the ADC modules fulfill requirements. Tests with a setup similar to that of the real experiment proved that the system works properly. The performance of all system components are validated to be suitable for B-mode measurements.
△ Less
Submitted 10 February, 2012; v1 submitted 3 December, 2011;
originally announced December 2011.