Showing 1–1 of 1 results for author: Haverkamp, N
-
Absolute frequency measurement of the 171Yb+ clock transition with a Kerr-lens mode-locked femtosecond laser
Authors:
Joern Stenger,
Christian Tamm,
Nils Haverkamp,
Stefan Weyers,
Harald R. Telle
Abstract:
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $ν_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency comb generator was used to phase-coherently link the optical frequency derived from a single trapped ion to a cesium fountain controlled hydrogen maser. This meas…
▽ More
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $ν_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency comb generator was used to phase-coherently link the optical frequency derived from a single trapped ion to a cesium fountain controlled hydrogen maser. This measurement is one of the most accurate measurements of optical frequencies ever reported, and it represents a contribution to the development of optical clocks based on an $^{171}$Yb$^+$ ion standard.
△ Less
Submitted 19 March, 2001; v1 submitted 14 March, 2001;
originally announced March 2001.