-
TIGRE v3: Efficient and easy to use iterative computed tomographic reconstruction toolbox for real datasets
Authors:
Ander Biguri,
Tomoyuki Sadakane,
Reuben Lindroos,
Yi Liu,
Malena Sabaté Landman,
Yi Du,
Manasavee Lohvithee,
Stefanie Kaser,
Sepideh Hatamikia,
Robert Bryll,
Emilien Valat,
Sarinrat Wonglee,
Thomas Blumensath,
Carola-Bibiane Schönlieb
Abstract:
Computed Tomography (CT) has been widely adopted in medicine and it is increasingly being used in scientific and industrial applications. Parallelly, research in different mathematical areas concerning discrete inverse problems has led to the development of new sophisticated numerical solvers that can be applied in the context of CT. The Tomographic Iterative GPU-based Reconstruction (TIGRE) toolb…
▽ More
Computed Tomography (CT) has been widely adopted in medicine and it is increasingly being used in scientific and industrial applications. Parallelly, research in different mathematical areas concerning discrete inverse problems has led to the development of new sophisticated numerical solvers that can be applied in the context of CT. The Tomographic Iterative GPU-based Reconstruction (TIGRE) toolbox was born almost a decade ago precisely in the gap between mathematics and high performance computing for real CT data, providing user-friendly open-source software tools for image reconstruction. However, since its inception, the tools' features and codebase have had over a twenty-fold increase, and are now including greater geometric flexibility, a variety of modern algorithms for image reconstruction, high-performance computing features and support for other CT modalities, like proton CT. The purpose of this work is two-fold: first, it provides a structured overview of the current version of the TIGRE toolbox, providing appropriate descriptions and references, and serving as a comprehensive and peer-reviewed guide for the user; second, it is an opportunity to illustrate the performance of several of the available solvers showcasing real CT acquisitions, which are typically not be openly available to algorithm developers.
△ Less
Submitted 13 December, 2024;
originally announced December 2024.
-
Intensity Normalization Techniques and Their Effect on the Robustness and Predictive Power of Breast MRI Radiomics
Authors:
Florian Schwarzhans,
Geevarghese George,
Lorena Escudero Sanchez,
Olgica Zaric,
Jean E Abraham,
Ramona Woitek,
Sepideh Hatamikia
Abstract:
Radiomics analysis has emerged as a promising approach for extracting quantitative features from medical images to aid in cancer diagnosis and treatment. However, radiomics research currently lacks standardization, and radiomics features can be highly dependent on the acquisition and pre-processing techniques used. In this study, we aim to investigate the effect of various intensity normalization…
▽ More
Radiomics analysis has emerged as a promising approach for extracting quantitative features from medical images to aid in cancer diagnosis and treatment. However, radiomics research currently lacks standardization, and radiomics features can be highly dependent on the acquisition and pre-processing techniques used. In this study, we aim to investigate the effect of various intensity normalization techniques on the robustness of radiomics features extracted from MRI scans of breast cancer patients. The images used are from the publicly available I-SPY TRIAL dataset, which contains MRI scans of stage 2 or 3 breast cancer patients and from the Platinum and PARP inhibitor for Neoadjuvant treatment of Triple Negative and / or BRCA positive breast cancer (PARTNER) trial. We compared the effect of commonly used intensity normalization techniques on the robustness of radiomics features using Intraclass Correlation Coefficient (ICC) between multiple combinations of normalization approaches, identified categories that are robust and therefore could be compared between studies regardless of the pre-processing used. We were able to show that while systematic differences between MRI scanners can significantly affect many radiomics features, a combination of Bias Field correction with piecewise linear histogram normalization can mitigate some of the effects compared to other normalization methods investigated in this paper. We were able to demonstrate the importance of carefully selecting and standardizing normalization methods for accurate and reliable radiomics analysis in breast MRI scans.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Breast MRI radiomics and machine learning radiomics-based predictions of response to neoadjuvant chemotherapy -- how are they affected by variations in tumour delineation?
Authors:
Sepideh Hatamikia,
Geevarghese George,
Florian Schwarzhans,
Amirreza Mahbod,
Ramona Woitek
Abstract:
Manual delineation of volumes of interest (VOIs) by experts is considered the gold-standard method in radiomics analysis. However, it suffers from inter- and intra-operator variability. A quantitative assessment of the impact of variations in these delineations on the performance of the radiomics predictors is required to develop robust radiomics based prediction models. In this study, we develope…
▽ More
Manual delineation of volumes of interest (VOIs) by experts is considered the gold-standard method in radiomics analysis. However, it suffers from inter- and intra-operator variability. A quantitative assessment of the impact of variations in these delineations on the performance of the radiomics predictors is required to develop robust radiomics based prediction models. In this study, we developed radiomics models for the prediction of pathological complete response to neoadjuvant chemotherapy in patients with two different breast cancer subtypes based on contrast-enhanced magnetic resonance imaging acquired prior to treatment (baseline MRI scans). Different mathematical operations such as erosion, smoothing, dilation, randomization, and ellipse fitting were applied to the original VOIs delineated by experts to simulate variations of segmentation masks. The effects of such VOI modifications on various steps of the radiomics workflow, including feature extraction, feature selection, and prediction performance, were evaluated. Using manual tumor VOIs and radiomics features extracted from baseline MRI scans, an AUC of up to 0.96 and 0.89 was achieved for human epidermal growth receptor 2 positive and triple-negative breast cancer, respectively. For smoothing and erosion, VOIs yielded the highest number of robust features and the best prediction performance, while ellipse fitting and dilation lead to the lowest robustness and prediction performance for both breast cancer subtypes. At most 28% of the selected features were similar to manual VOIs when different VOI delineation data were used. Differences in VOI delineation affects different steps of radiomics analysis, and their quantification is therefore important for development of standardized radiomics research.
△ Less
Submitted 3 September, 2023;
originally announced September 2023.
-
Silicone phantoms fabricated with multi-material extrusion 3D printing technology mimicking imaging properties of soft tissues in CT
Authors:
Sepideh Hatamikia,
Laszlo Jaksa,
Gernot Kronreif,
Wolfgang Birkfellner,
Joachim Kettenbach,
Martin Buschmann,
Andrea Lorenz
Abstract:
Recently, 3D printing has been widely used to fabricate medical imaging phantoms. So far, various rigid 3D printable materials have been investigated for their radiological properties and efficiency in imaging phantom fabrication. However, flexible, soft tissue materials are also needed for imaging phantoms, which are used in various scenarios, such as anatomical deformations to improve dynamic tr…
▽ More
Recently, 3D printing has been widely used to fabricate medical imaging phantoms. So far, various rigid 3D printable materials have been investigated for their radiological properties and efficiency in imaging phantom fabrication. However, flexible, soft tissue materials are also needed for imaging phantoms, which are used in various scenarios, such as anatomical deformations to improve dynamic treatments and various needle-based surgeries and training. Recently, various silicone additive manufacturing technologies have been used to produce anatomical models based on extrusion techniques that allow the fabrication of soft tissue materials. To date, there is no systematic study in the literature investigating the radiological properties of silicone rubber materials/fluids for imaging phantoms fabricated directly by extrusion using 3D printing techniques. The aim of this study was to investigate the radiological properties of 3D printed phantoms made of silicone in CT imaging. The radiodensity as described as Hounsfield Units (HU) of several test phantoms composed of three different silicone printing materials were evaluated by changing the infill density to adjust their radiological properties. A comparison of HU values with a Gammex Tissue Characterization Phantom was performed. A scaled down anatomical model derived from an abdominal CT was also fabricated and the resulting HU values were evaluated. For the three different silicone materials, a spectrum ranging from -639 to +780 HU was obtained on CT at a scan setting of 120 kVp. A good agreement was observed between the HU target values in abdominal CT and the HU values of the 3D-printed anatomical phantom in all tissues. Moreover, using different infill densities, the printed materials were able to achieve a similar radiodensity range as obtained in different tissue-equivalent inserts in the Gammex phantom (238 HU to -673 HU).
△ Less
Submitted 6 December, 2022;
originally announced December 2022.
-
Realistic 3D printed imaging tumor phantoms for validation of image processing algorithms
Authors:
Sepideh Hatamikia,
Ingo Gulyas,
Wolfgang Birkfellner,
Gernot Kronreif,
Alexander Unger,
Gunpreet Oberoi,
Andrea Lorenz,
Ewald Unger,
Joachim Kettenbach,
Michael Figl,
Janina Patsch,
Andreas Strassl,
Dietmar Georg,
Andreas Renner
Abstract:
Medical imaging phantoms are widely used for validation and verification of imaging systems and algorithms in surgical guidance and radiation oncology procedures. Especially, for the performance evaluation of new algorithms in the field of medical imaging, manufactured phantoms need to replicate specific properties of the human body, e.g., tissue morphology and radiological properties. Additive ma…
▽ More
Medical imaging phantoms are widely used for validation and verification of imaging systems and algorithms in surgical guidance and radiation oncology procedures. Especially, for the performance evaluation of new algorithms in the field of medical imaging, manufactured phantoms need to replicate specific properties of the human body, e.g., tissue morphology and radiological properties. Additive manufacturing (AM) technology provides an inexpensive opportunity for accurate anatomical replication with customization capabilities. In this study, we proposed a simple and cheap protocol to manufacture realistic tumor phantoms based on the filament 3D printing technology. Tumor phantoms with both homogenous and heterogenous radiodensity were fabricated. The radiodensity similarity between the printed tumor models and real tumor data from CT images of lung cancer patients was evaluated. Additionally, it was investigated whether a heterogeneity in the 3D printed tumor phantoms as observed in the tumor patient data had an influence on the validation of image registration algorithms. A density range between -217 to 226 HUs was achieved for 3D printed phantoms; this range of radiation attenuation is also observed in the human lung tumor tissue. The resulted HU range could serve as a lookup-table for researchers and phantom manufactures to create realistic CT tumor phantoms with the desired range of radiodensities. The 3D printed tumor phantoms also precisely replicated real lung tumor patient data regarding morphology and could also include life-like heterogeneity of the radiodensity inside the tumor models. An influence of the heterogeneity on accuracy and robustness of the image registration algorithms was not found.
△ Less
Submitted 27 November, 2022;
originally announced November 2022.
-
Imaging with protons at MedAustron
Authors:
F. Ulrich-Pur,
T. Bergauer,
A. Burker,
S. Hatamikia,
A. Hirtl,
C. Irmler,
S. Kaser,
P. Paulitsch,
F. Pitters,
V. Teufelhart
Abstract:
Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sourc…
▽ More
Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sources of inaccuracy in alculation of the stopping power (SP). A more precise method to acquire the SP is to directly use high energy protons (or other ions such as carbon) and perform proton computed tomography (pCT). With this method, the ions are tracked prior to entering and after leaving the patient and finally their residual energy is measured at the very end. Therefore, an ion imaging demonstrator, comprising a tracking telescope made from double-sided silicon strip detectors and a range telescope as a residual energy detector, was set up. First measurements with this setup were performed at beam tests at MedAustron, a center for ion therapy and research in \mbox{Wiener Neustadt}, \mbox{Austria}. The facility provides three rooms for cancer treatment with proton beams as well as one which is dedicated to non-clinical research. This contribution describes the principle of ion imaging with proton beams in general as well as the design of the experimental setup. Moreover, first results from simulations and recent beam tests as well as ideas for future developments will be presented.
△ Less
Submitted 15 July, 2020; v1 submitted 28 February, 2020;
originally announced March 2020.