Frequency-Temperature sensitivity reduction with optimized microwave Bragg resonators
Authors:
Jean-Michel Le Floch,
Christopher Murphy,
John Gideon Hartnett,
Valerie Madrangeas,
Jerzy Krupka,
Dominique Cros,
Michael Edmund Tobar
Abstract:
Dielectric resonators are employed to build state-of-the-art low-noise and high- stability oscillators operating at room and cryogenic temperatures. A resonator temperature coefficient of frequency is one criterion of performance. This paper reports on predictions and measurements of this temperature coefficient of frequency for three types of cylindrically-symmetric Bragg resonators operated at m…
▽ More
Dielectric resonators are employed to build state-of-the-art low-noise and high- stability oscillators operating at room and cryogenic temperatures. A resonator temperature coefficient of frequency is one criterion of performance. This paper reports on predictions and measurements of this temperature coefficient of frequency for three types of cylindrically-symmetric Bragg resonators operated at microwave frequencies. At room temperature, microwave Bragg resonators have the best potential to reach extremely high Q-factors. Research has been conducted over the last decade on modeling, optimizing and realizing such high Q-factor devices for applications such as filtering, sensing, and frequency metrology. We present an optimized design, which has a temperature sensitivity 2 to 4 times less than current whispering gallery mode resonators without using temperature compensating techniques and about 30% less than other existing Bragg resonators. Also, the performance of a new generation single-layered Bragg resonators, based on a hybrid-Bragg-mode, is reported with a sensitivity of about -12ppm/K at 295K. For a single reflector resonator, it achieves a similar level of performance as a double-Bragg-reflector resonator but with a more compact structure and performs six times better than whispering-gallery-mode resonators. The hybrid resonator promises to deliver a new generation of high-sensitivity sensors and high-stability room-temperature oscillators.
△ Less
Submitted 6 January, 2017;
originally announced January 2017.
-
Generalizing the Lorentz transformations
Authors:
James M. Chappell,
David L. Berkahn,
Nicolangelo Iannella,
John G. Hartnett,
Azhar Iqbal,
Derek Abbott
Abstract:
In this paper we develop a framework allowing a natural extension of the Lorentz transformations. To begin, we show that by expanding conventional four-dimensional spacetime to eight-dimensions that a natural generalization is indeed obtained. We then find with these generalized coordinate transformations acting on Maxwell's equations that the electromagnetic field transformations are nevertheless…
▽ More
In this paper we develop a framework allowing a natural extension of the Lorentz transformations. To begin, we show that by expanding conventional four-dimensional spacetime to eight-dimensions that a natural generalization is indeed obtained. We then find with these generalized coordinate transformations acting on Maxwell's equations that the electromagnetic field transformations are nevertheless unchanged. We find further, that if we assume the absence of magnetic monopoles, in accordance with Maxwell's theory, our generalized transformations are then restricted to be the conventional ones. While the conventional Lorentz transformations are indeed recovered from our framework, we nevertheless provide a new perspective into why the Lorentz transformations are constrained to be the conventional ones. Also, this generalized framework may assist in explaining several unresolved questions in electromagnetism as well as to be able to describe quasi magnetic monopoles found in spin-ice systems.
△ Less
Submitted 31 October, 2016;
originally announced November 2016.
-
Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1
Authors:
Myoung-Sun Heo,
Sang Eon Park,
Won-Kyu Lee,
Sang-Bum Lee,
Hyun-Gue Hong,
Taeg Yong Kwon,
Chang Yong Park,
Dai-Hyuk Yu,
G. Santarelli,
Ashby Hilton,
Andre N. Luiten,
John G. Hartnett
Abstract:
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency c…
▽ More
In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultra-stable laser, is better than $5\times10^{-15}$ at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the fountain at 1-s averaging time reaches $2.5\times10^{-14}$ at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator in the synthesis chain is ramped linearly. By doing this, the stability of the synthesizer at an average time of one hour reaches a level of $10^{-16}$ which is measured with the fountain clock.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
A brief study of time
Authors:
James M. Chappell,
John G. Hartnett,
Azhar Iqbal,
Nicolangelo Iannella,
Derek Abbott
Abstract:
Understanding the nature of time remains a key unsolved problem in science. Newton in the Principia asserted an absolute universal time that {\it `flows equably'}. Hamilton then proposed a mathematical unification of space and time within the framework of the quaternions that ultimately lead to the famous Minkowski formulation in 1908 using four-vectors. The Minkowski framework is found to provide…
▽ More
Understanding the nature of time remains a key unsolved problem in science. Newton in the Principia asserted an absolute universal time that {\it `flows equably'}. Hamilton then proposed a mathematical unification of space and time within the framework of the quaternions that ultimately lead to the famous Minkowski formulation in 1908 using four-vectors. The Minkowski framework is found to provide a versatile formalism for describing the relationship between space and time in accordance with relativistic principles, but nevertheless fails to provide deeper insights into the physical origin of time and its properties. In this paper we begin with a recognition of the fundamental role played by three-dimensional space in physics that we model using the Clifford algebra multivector. From this geometrical foundation we are then able to identify a plausible origin for our concept of time. This geometrical perspective also allows us to make a key topological distinction between time and space, with time being a point-like quantity. The multivector then allows a generalized unification of time and space within a Minkowski-like description.
△ Less
Submitted 30 October, 2015; v1 submitted 12 September, 2015;
originally announced September 2015.
-
The vector algebra war: a historical perspective
Authors:
James M. Chappell,
Azhar Iqbal,
John G. Hartnett,
Derek Abbott
Abstract:
There are a wide variety of different vector formalisms currently utilized in engineering and physics. For example, Gibbs' three-vectors, Minkowski four-vectors, complex spinors in quantum mechanics, quaternions used to describe rigid body rotations and vectors defined in Clifford geometric algebra. With such a range of vector formalisms in use, it thus appears that there is as yet no general agre…
▽ More
There are a wide variety of different vector formalisms currently utilized in engineering and physics. For example, Gibbs' three-vectors, Minkowski four-vectors, complex spinors in quantum mechanics, quaternions used to describe rigid body rotations and vectors defined in Clifford geometric algebra. With such a range of vector formalisms in use, it thus appears that there is as yet no general agreement on a vector formalism suitable for science as a whole. This is surprising, in that, one of the primary goals of nineteenth century science was to suitably describe vectors in three-dimensional space. This situation has also had the unfortunate consequence of fragmenting knowledge across many disciplines, and requiring a significant amount of time and effort in learning the various formalisms. We thus historically review the development of our various vector systems and conclude that Clifford's multivectors best fulfills the goal of describing vectorial quantities in three dimensions and providing a unified vector system for science.
△ Less
Submitted 21 April, 2016; v1 submitted 29 August, 2015;
originally announced September 2015.
-
A new derivation of the Minkowski metric
Authors:
James M. Chappell,
John G. Hartnett,
Nicolangelo Iannella,
Azhar Iqbal,
David L. Berkahn,
Derek Abbott
Abstract:
The four dimensional spacetime continuum, as first conceived by Minkowski, has become the dominant framework within which to describe physical laws. In this paper, we show how this four-dimensional structure is a natural property of physical three-dimensional space, if modeled with Clifford geometric algebra $ C\ell(\Re^3) $. We find that Minkowski spacetime can be embedded within a larger eight d…
▽ More
The four dimensional spacetime continuum, as first conceived by Minkowski, has become the dominant framework within which to describe physical laws. In this paper, we show how this four-dimensional structure is a natural property of physical three-dimensional space, if modeled with Clifford geometric algebra $ C\ell(\Re^3) $. We find that Minkowski spacetime can be embedded within a larger eight dimensional structure. This then allows a generalisation of the invariant interval and the Lorentz transformations. Also, with this geometric oriented approach the fixed speed of light, the laws of special relativity and a generalised form of Maxwell's equations, arise naturally from the intrinsic properties of the algebra without recourse to physical arguments. We also find new insights into the nature of time, which can be described as two-dimensional. Some philosophical implications of this approach as it relates to the foundations of physical theories are also discussed.
△ Less
Submitted 27 September, 2024; v1 submitted 15 January, 2015;
originally announced January 2015.
-
Direct Terrestrial Test of Lorentz Symmetry in Electrodynamics to 10$^{-18}$
Authors:
M. Nagel,
S. R. Parker,
E. V. Kovalchuk,
P. L. Stanwix,
J. G. Hartnett,
E. N. Ivanov,
A. Peters,
M. E. Tobar
Abstract:
Lorentz symmetry is a foundational property of modern physics, underlying the standard model of particles and general relativity. It is anticipated that these two theories are low energy approximations of a single theory that is unified and consistent at the Planck scale. Many unifying proposals allow Lorentz symmetry to be broken, with observable effects appearing at Planck-suppressed levels; thu…
▽ More
Lorentz symmetry is a foundational property of modern physics, underlying the standard model of particles and general relativity. It is anticipated that these two theories are low energy approximations of a single theory that is unified and consistent at the Planck scale. Many unifying proposals allow Lorentz symmetry to be broken, with observable effects appearing at Planck-suppressed levels; thus precision tests of Lorentz invariance are needed to assess and guide theoretical efforts. Here, we use ultra-stable oscillator frequency sources to perform a modern Michelson-Morley experiment and make the most precise direct terrestrial test to date of Lorentz symmetry for the photon, constraining Lorentz violating orientation-dependent relative frequency changes $Δν$/$ν$ to 9.2$\pm$10.7$\times10^{-19}$ (95$\%$ confidence interval). This order of magnitude improvement over previous Michelson-Morley experiments allows us to set comprehensive simultaneous bounds on nine boost and rotation anisotropies of the speed of light, finding no significant violations of Lorentz symmetry.
△ Less
Submitted 14 September, 2015; v1 submitted 22 December, 2014;
originally announced December 2014.
-
Cryogenic resonant microwave cavity searches for hidden sector photons
Authors:
Stephen R. Parker,
John G. Hartnett,
Rhys G. Povey,
Michael E. Tobar
Abstract:
The hidden sector photon is a weakly interacting hypothetical particle with sub-eV mass that kinetically mixes with the photon. We describe a microwave frequency light shining through a wall experiment where a cryogenic resonant microwave cavity is used to try and detect photons that have passed through an impenetrable barrier, a process only possible via mixing with hidden sector photons. For a h…
▽ More
The hidden sector photon is a weakly interacting hypothetical particle with sub-eV mass that kinetically mixes with the photon. We describe a microwave frequency light shining through a wall experiment where a cryogenic resonant microwave cavity is used to try and detect photons that have passed through an impenetrable barrier, a process only possible via mixing with hidden sector photons. For a hidden sector photon mass of 53 $μ$eV we limit the hidden photon kinetic mixing parameter $χ< 1.7\times10^{-7}$, which is an order of magnitude lower than previous bounds derived from cavity experiments in the same mass range. In addition, we use the cryogenic detector cavity to place new limits on the kinetic mixing parameter for hidden sector photons as a form of cold dark matter.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
Extending the frequency range of digital noise measurements to the microwave domain
Authors:
Stephen R. Parker,
Eugene N. Ivanov,
John G. Hartnett
Abstract:
We describe the use of digital phase noise test sets at frequencies well beyond the sampling rate of their analog-to-digital converters. The technique proposed involves the transfer of phase fluctuations from an arbitrary high carrier frequency to within the operating frequency range of the digital instrument. The validity of the proposed technique has been proven via comparison with conventional…
▽ More
We describe the use of digital phase noise test sets at frequencies well beyond the sampling rate of their analog-to-digital converters. The technique proposed involves the transfer of phase fluctuations from an arbitrary high carrier frequency to within the operating frequency range of the digital instrument. The validity of the proposed technique has been proven via comparison with conventional methods. Digital noise measurements eliminate the need for calibration and improve consistency of experimental results. Mechanisms limiting the resolution of spectral measurements are also discussed.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
Resonator Power to Frequency Conversion in a Cryogenic Sapphire Oscillator
Authors:
Nitin R. Nand,
Stephen R. Parker,
Eugene N. Ivanov,
Jean-Michel le-Floch,
John G. Hartnett,
Michael E. Tobar
Abstract:
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a sh…
▽ More
We report on the measurement and characterization of power to frequency conversion in the resonant mode of a cryogenic sapphire loaded cavity resonator, which is used as the frequency discriminating element of a loop oscillator circuit. Fluctuations of power incident on the resonator leads to changes in radiation pressure and temperature in the sapphire dielectric, both of which contribute to a shift in the resonance frequency. We measure a modulation and temperature independent radiation pressure induced power to frequency sensitivity of -0.15 Hz/mW and find that this is the primary factor limiting the stability of the resonator frequency.
△ Less
Submitted 23 July, 2013;
originally announced July 2013.
-
Comparison of ultra-stable radio frequency signals synthesized from independent secondary microwave frequency standards
Authors:
John G. Hartnett,
Stephen R. Parker,
Eugene N. Ivanov,
Travis Povey,
Nitin R. Nand,
Jean-Michel le Floch
Abstract:
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the exp…
▽ More
The phase noise and frequency stability measurements of 1 GHz, 100 MHz, and 10 MHz signals are presented which have been synthesized from microwave cryogenic sapphire oscillators using ultra-low-vibration pulse-tube cryocooler technology. We present the measured data using independent cryogenic oscillators for the 100 MHz and 10 MHz synthesized signals, whereas previously we only estimated the expected results based on residual phase noise measurements, when only one cryogenic oscillator was available. In addition we present the design of a 1 GHz synthesizer using a Crystek voltage controlled oscillator phase locked to 1 GHz output derived from a cryogenic sapphire oscillator.
△ Less
Submitted 31 January, 2013;
originally announced February 2013.
-
A transposed frequency technique for phase noise and frequency stability measurements
Authors:
John G. Hartnett,
Travis Povey,
Stephen Parker,
Eugene Ivanov
Abstract:
The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, which extends the frequency range of digital noise measurements to the microwave domain and beyond. We discuss two basic variations of the proposed noise…
▽ More
The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, which extends the frequency range of digital noise measurements to the microwave domain and beyond. We discuss two basic variations of the proposed noise measurement technique, one of which enables characterization of phase fluctuations added to the passing signal by the particular microwave component, for example by an amplifier, while another one is intended for measurements of phase fluctuations of the incoming signal itself.
△ Less
Submitted 28 November, 2012; v1 submitted 28 August, 2012;
originally announced September 2012.
-
Ultra-low-phase-noise cryocooled microwave dielectric-sapphire-resonator oscillators with 1 x 10^-16 frequency instability
Authors:
John G. Hartnett,
Nitin R. Nand,
Chuan Lu
Abstract:
Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The phase noise for a single oscillator is measured at -105 dBc/Hz at 1 Hz offset on the 11.2 GHz carrier. The oscillator fractional frequency stability is characterize…
▽ More
Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The phase noise for a single oscillator is measured at -105 dBc/Hz at 1 Hz offset on the 11.2 GHz carrier. The oscillator fractional frequency stability is characterized in terms of Allan deviation by 5.3 x 10^-16 tau^-1/2 + 9 x 10^-17 for integration times 0.1 s < tau < 1000 s and is limited by a flicker frequency noise floor below 1 x 10^-16. This result is better than any other microwave source even those generated from an optical comb phase-locked to a room temperature ultra-stable optical cavity.
△ Less
Submitted 6 March, 2012; v1 submitted 10 February, 2012;
originally announced February 2012.
-
Is the Universe really expanding?
Authors:
John G. Hartnett
Abstract:
The Hubble law, determined from the distance modulii and redshifts of galaxies, for the past 80 years, has been used as strong evidence for an expanding universe. This claim is reviewed in light of the claimed lack of necessary evidence for time dilation in quasar and gamma-ray burst luminosity variations and other lines of evidence. It is concluded that the observations could be used to describe…
▽ More
The Hubble law, determined from the distance modulii and redshifts of galaxies, for the past 80 years, has been used as strong evidence for an expanding universe. This claim is reviewed in light of the claimed lack of necessary evidence for time dilation in quasar and gamma-ray burst luminosity variations and other lines of evidence. It is concluded that the observations could be used to describe either a static universe (where the Hubble law results from some as-yet-unknown mechanism) or an expanding universe described by the standard Lambda cold dark matter model. In the latter case, size evolution of galaxies is necessary for agreement with observations. Yet the simple non-expanding Euclidean universe fits most data with the least number of assumptions. From this review it is apparent that there are still many unanswered questions in cosmology and the title question of this paper is still far from being answered.
△ Less
Submitted 19 November, 2011; v1 submitted 13 July, 2011;
originally announced July 2011.
-
Microwave cavity hidden sector photon threshold crossing
Authors:
Rhys G. Povey,
John G. Hartnett,
Michael E. Tobar
Abstract:
Hidden sector photons are a weakly interacting slim particle arising from an additional U(1) gauge symmetry predicted by many standard model extensions. We present and demonstrate a new experimental method using a single microwave cavity to search for hidden sector photons. Only photons with a great enough energy are able to oscillate into hidden sector photons of a particular mass. If our cavity…
▽ More
Hidden sector photons are a weakly interacting slim particle arising from an additional U(1) gauge symmetry predicted by many standard model extensions. We present and demonstrate a new experimental method using a single microwave cavity to search for hidden sector photons. Only photons with a great enough energy are able to oscillate into hidden sector photons of a particular mass. If our cavity is driven on resonance and tuned over the corresponding threshold frequency, there is an observable drop in the circulating power signifying the creation of hidden sector photons. This approach avoids the problems of microwave leakage and frequency matching inherent in photon regeneration techniques.
△ Less
Submitted 31 May, 2011;
originally announced May 2011.
-
Ultra stable and very low noise signal source using a cryocooled sapphire oscillator for VLBI
Authors:
Nitin R. Nand,
John G. Hartnett,
Eugene N. Ivanov,
Giorgio Santarelli
Abstract:
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected…
▽ More
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator.
The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time.
The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 τ^-1 + 3.6 x 10^-15 τ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 τ^-1/2 + 3 x 10^-16, respectively, for 1 s < τ< 10^4 s.
We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
High Resolution Flicker-Noise-Free Frequency Measurements of Weak Microwave Signals
Authors:
Daniel L. Creedon,
Michael E. Tobar,
Eugene N. Ivanov,
John G. Hartnett
Abstract:
Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency fr…
▽ More
Amplification is usually necessary when measuring the frequency instability of microwave signals. In this work, we develop a flicker noise free frequency measurement system based on a common or shared amplifier. First, we show that correlated flicker phase noise can be cancelled in such a system. Then we compare the new system with the conventional by simultaneously measuring the beat frequency from two cryogenic sapphire oscillators with parts in 10^15 fractional frequency instability. We determine for low power, below -80 dBm, the measurements were not limited by correlated noise processes but by thermal noise of the readout amplifier. In this regime, we show that the new readout system performs as expected and at the same level as the standard system but with only half the number of amplifiers. We also show that, using a standard readout system, the next generation of cryogenic sapphire oscillators could be flicker phase noise limited when instability reaches parts in 10^16 or better
△ Less
Submitted 17 April, 2011;
originally announced April 2011.
-
Resonant Regeneration in the Sub-Quantum Regime -- A demonstration of fractional quantum interference
Authors:
John G. Hartnett,
Joerg Jaeckel,
Rhys G. Povey,
Michael E. Tobar
Abstract:
Light shining through wall experiments (in the optical as well as in the microwave regime) are a powerful tool to search for light particles coupled very weakly to photons such as axions or extra hidden sector photons. Resonant regeneration, where a resonant cavity is employed to enhance the regeneration rate of photons, is one of the most promising techniques to improve the sensitivity of the nex…
▽ More
Light shining through wall experiments (in the optical as well as in the microwave regime) are a powerful tool to search for light particles coupled very weakly to photons such as axions or extra hidden sector photons. Resonant regeneration, where a resonant cavity is employed to enhance the regeneration rate of photons, is one of the most promising techniques to improve the sensitivity of the next generation of experiments. However, doubts have been voiced if such methods work at very low regeneration rates where on average the cavity contains less than one photon. In this note we report on a demonstration experiment using a microwave cavity driven with extremely low power, to show that resonant amplification works also in this regime. In accordance with standard quantum mechanics this is a demonstration that interference also works at the level of less than one quantum. As an additional benefit this experiment shows that thermal photons inside the cavity cause no adverse effects.
△ Less
Submitted 21 January, 2011;
originally announced January 2011.
-
Detrapping and retrapping of free carriers in nominally pure single crystal GaP, GaAs and 4H-SiC semiconductors under light illumination at cryogenic temperatures
Authors:
David Mouneyrac,
John G. Hartnett,
Jean-Michel Le Floch,
Michael E. Tobar,
Dominique Cros,
Jerzy Krupka
Abstract:
We report on extremely sensitive measurements of changes in the microwave properties of high purity non-intentionally-doped single-crystal semiconductor samples of gallium phosphide, gallium arsenide and 4H-silicon carbide when illuminated with light of different wavelengths at cryogenic temperatures. Whispering gallery modes were excited in the semiconductors whilst they were cooled on the coldfi…
▽ More
We report on extremely sensitive measurements of changes in the microwave properties of high purity non-intentionally-doped single-crystal semiconductor samples of gallium phosphide, gallium arsenide and 4H-silicon carbide when illuminated with light of different wavelengths at cryogenic temperatures. Whispering gallery modes were excited in the semiconductors whilst they were cooled on the coldfinger of a single-stage cryocooler and their frequencies and Q-factors measured under light and dark conditions. With these materials, the whispering gallery mode technique is able to resolve changes of a few parts per million in the permittivity and the microwave losses as compared with those measured in darkness. A phenomenological model is proposed to explain the observed changes, which result not from direct valence to conduction band transitions but from detrapping and retrapping of carriers from impurity/defect sites with ionization energies that lay in the semiconductor band gap. Detrapping and retrapping relaxation times have been evaluated from comparison with measured data.
△ Less
Submitted 8 October, 2010;
originally announced October 2010.
-
Ultra-low vibration pulse-tube cryocooler stabilized cryogenic sapphire oscillator with 10^-16 fractional frequency stability
Authors:
John G. Hartnett,
Nitin R. Nand
Abstract:
A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world's most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations hav…
▽ More
A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world's most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations have been evaluated by comparing it to an ultra-stable liquid-helium cooled cryogenic sapphire oscillator in the same laboratory. Assuming both contribute equally, the Allan deviation evaluated for the cryocooled oscillator is sigma_y = 1 x 10^-15 tau^-1/2 for integration times 1 < tau < 10 s with a minimum sigma_y = 3.9 x 10^-16 at tau = 20 s. The long term frequency drift is less than 5 x 10^-14/day. From the measured power spectral density of phase fluctuations the single side band phase noise can be represented by L_phi(f) = 10^-14.0/f^4+10^-11.6/f^3+10^-10.0/f^2+10^-10.2/f+ 10^-11.0 for Fourier frequencies 10^-3<f<10^3 Hz in the single oscillator. As a result L_phi approx -97.5 dBc/Hz at 1 Hz offset from the carrier.
△ Less
Submitted 1 September, 2010; v1 submitted 16 April, 2010;
originally announced April 2010.
-
Stability measurements of microwave frequency synthesis with liquid helium cooled cryogenic sapphire oscillators
Authors:
J. G. Hartnett,
D. L. Creedon,
D. Chambon,
G. Santarelli
Abstract:
We report on the evaluation of microwave frequency synthesis using two cryogenic sapphire oscillators developed at the University of Western Australia. A down converter is used to make comparisons between microwave clocks at different frequencies, where the synthesized signal has a stability not significantly different from the reference oscillator. By combining the CSO with a H-maser, a referenc…
▽ More
We report on the evaluation of microwave frequency synthesis using two cryogenic sapphire oscillators developed at the University of Western Australia. A down converter is used to make comparisons between microwave clocks at different frequencies, where the synthesized signal has a stability not significantly different from the reference oscillator. By combining the CSO with a H-maser, a reference source of arbitrary frequency at X-band can be synthesized with a fractional frequency stability of sub-$4 \times 10^{-15}$ for integration times between 1 s and 10,000 s.
△ Less
Submitted 6 April, 2010;
originally announced April 2010.
-
Cryogenic Sapphire Oscillator using a low-vibration design pulse-tube cryocooler: First results
Authors:
John G. Hartnett,
Nitin R. Nand,
Chao Wang,
Jean-Michel Le Floch
Abstract:
A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fractional frequency instability is $σ_y = 1.4 \times 10^{-15}τ^{-1/2}$ for integration times $1 < τ< 10$ s, dominated by white frequency noise. The m…
▽ More
A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fractional frequency instability is $σ_y = 1.4 \times 10^{-15}τ^{-1/2}$ for integration times $1 < τ< 10$ s, dominated by white frequency noise. The minimum $σ_y = 5.3 \times 10^{-16}$ for the two oscillators was reached at $τ= 20$ s. Assuming equal contributions from both CSOs, the single oscillator phase noise $S_φ \approx -96 \; dB \; rad^2/Hz$ at 1 Hz offset from the carrier.
△ Less
Submitted 4 April, 2010;
originally announced April 2010.
-
Rotating Odd-Parity Lorentz Invariance Test in Electrodynamics
Authors:
Michael E. Tobar,
Eugene N. Ivanov,
Paul L. Stanwix,
Jean-Michel G. le Floch,
John G. Hartnett
Abstract:
We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ κ_{tr}$ of $-0.3\pm 3\times10^{-7}$. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of…
▽ More
We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ κ_{tr}$ of $-0.3\pm 3\times10^{-7}$. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of $2\times10^{-11} rad/\sqrt{Hz}$) we show an improvement of several orders of magnitude is attainable in the future.
△ Less
Submitted 24 November, 2009; v1 submitted 10 September, 2009;
originally announced September 2009.
-
Observation of persistent photoconductivity in bulk Gallium Arsenide and Gallium Phosphide samples at cryogenic temperatures using the Whispering Gallery mode method
Authors:
J. G. Hartnett,
D. Mouneyrac,
J. -M. Le Floch,
J. Krupka,
M. E. Tobar,
D. Cros
Abstract:
Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at cryogenics temperatures < 50 K. In both cases persistent photoconductivity was observed after initially exposing semiconductors to white light from a halogen lamp. Photoconductance decay time constants for GaP and GaAs were determined to be 0.90…
▽ More
Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at cryogenics temperatures < 50 K. In both cases persistent photoconductivity was observed after initially exposing semiconductors to white light from a halogen lamp. Photoconductance decay time constants for GaP and GaAs were determined to be 0.900 +/- 0.081 ns and 1.098 +/- 0.063 ns, respectively, using this method.
△ Less
Submitted 12 June, 2009;
originally announced June 2009.
-
Modified permittivity observed in bulk Gallium Arsenide and Gallium Phosphide samples at 50 K using the Whispering Gallery mode method
Authors:
J. G. Hartnett,
D. Mouneyrac,
J-M. Le Floch,
J. Krupka,
Michael E. Tobar,
D. Cros
Abstract:
Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at 50 K. In both samples we observed change in permittivity under light and dark conditions. This results from a change in the polarization state of the semiconductor, which is consistent with a free electron-hole creation/recombination process. Th…
▽ More
Whispering Gallery modes in bulk cylindrical Gallium Arsenide and Gallium Phosphide samples have been examined both in darkness and under white light at 50 K. In both samples we observed change in permittivity under light and dark conditions. This results from a change in the polarization state of the semiconductor, which is consistent with a free electron-hole creation/recombination process. The permittivity of the semiconductor is modified by free photocarriers in the surface layers of the sample which is the region sampled by Whispering Gallery modes.
△ Less
Submitted 10 June, 2009;
originally announced June 2009.
-
Spheroidal and elliptical galaxy radial velocity dispersion determined from Cosmological General Relativity
Authors:
John G. Hartnett
Abstract:
Radial velocity dispersion in spheroidal and elliptical galaxies, as a function of radial distance from the center of the galaxy, has been derived from Cosmological Special Relativity. For velocity dispersions in the outer regions of spherical galaxies, the dynamical mass calculated for a galaxy using Carmelian theory may be 10 to 100 times less than that calculated from standard Newtonian physi…
▽ More
Radial velocity dispersion in spheroidal and elliptical galaxies, as a function of radial distance from the center of the galaxy, has been derived from Cosmological Special Relativity. For velocity dispersions in the outer regions of spherical galaxies, the dynamical mass calculated for a galaxy using Carmelian theory may be 10 to 100 times less than that calculated from standard Newtonian physics. This means there is no need to include halo dark matter. The velocity dispersion is found to be approximately constant across the galaxy after falling from an initial high value at the center.
△ Less
Submitted 19 July, 2007;
originally announced July 2007.
-
Extending the redshift-distance relation in Cosmological General Relativity to higher redshifts
Authors:
John G. Hartnett
Abstract:
The redshift-distance modulus relation, the Hubble Diagram, derived from Cosmological General Relativity has been extended to arbitrarily large redshifts. Numerical methods were employed and a density function was found that results in a valid solution of the field equations at all redshifts. The extension has been compared to 302 type Ia supernova data as well as to 69 Gamma-ray burst data. The…
▽ More
The redshift-distance modulus relation, the Hubble Diagram, derived from Cosmological General Relativity has been extended to arbitrarily large redshifts. Numerical methods were employed and a density function was found that results in a valid solution of the field equations at all redshifts. The extension has been compared to 302 type Ia supernova data as well as to 69 Gamma-ray burst data. The latter however do not not truly represent a `standard candle' as the derived distance modulii are not independent of the cosmology used. Nevertheless the analysis shows a good fit can be achieved without the need to assume the existence of dark matter.
The Carmelian theory is also shown to describe a universe that is always spatially flat. This results from the underlying assumption of the energy density of a cosmological constant $Ω_Λ = 1$, the result of vacuum energy. The curvature of the universe is described by a \textit{spacevelocity} metric where the energy content of the curvature at any epoch is $Ω_K = Ω_Λ - Ω= 1-Ω$, where $Ω$ is the matter density of the universe. Hence the total density is always $Ω_K + Ω= 1$
△ Less
Submitted 21 November, 2007; v1 submitted 22 May, 2007;
originally announced May 2007.
-
Long Term Operation and Performance of Cryogenic Sapphire Oscillators
Authors:
M. E. Tobar,
E. N. Ivanov,
C. R. Locke,
P. L. Stanwix,
J. G. Hartnett,
A. N. Luiten,
R. B. Warrington,
P. T. H. Fisk,
M. A. Lawn,
M. J. Wouters,
S. Bize,
G. Santarelli,
P. Wolf,
A. Clairon,
P. Guillemot
Abstract:
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive…
▽ More
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.
△ Less
Submitted 19 August, 2006;
originally announced August 2006.
-
Cryogenic sapphire oscillator with exceptionally high long-term frequency stability
Authors:
J. G. Hartnett,
C. R. Locke,
E. N. Ivanov,
M. E. Tobar,
P. L. Stanwix
Abstract:
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
We report on the development of a sapphire cryogenic microwave resonator oscillator long-term fractional frequency stability of 2x10^-17Sqrt[τ] for integration times τ>10^3 s and negative drift of about 2.2x10^-15/day. The short-term frequency instability of the oscillator is highly reproducible and also state-of-the-art: 5.6x10^-16 for an integration time of τ~ 20 s.
△ Less
Submitted 3 October, 2006; v1 submitted 11 August, 2006;
originally announced August 2006.