-
Improved optical standing-wave beam splitters for dilute Bose-Einstein condensates
Authors:
Mary Clare Cassidy,
Malcolm G. Boshier,
Lee E. Harrell
Abstract:
Bose-Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that…
▽ More
Bose-Einstein condensate (BEC)-based atom interferometry exploits low temperatures and long coherence lengths to facilitate high-precision measurements. Progress in atom interferometry promises improvements in navigational devices like gyroscopes and accelerometers, as well as applications in fundamental physics such as accurate determination of physical constants. Previous work demonstrates that beam splitters and mirrors for coherent manipulation of dilute BEC momentum in atom interferometers can be implemented with sequences of non-resonant standing-wave light pulses. While previous work focuses on the optimization of the optical pulses' amplitude and duration to produce high-order momentum states with high fidelity, we explore how varying the shape of the optical pulses affects optimal beam-splitter performance, as well as the effect of pulse shape on the sensitivity of optimized parameters in achieving high fidelity in high-momentum states. In simulations of two-pulse beam splitters utilizing optimized square, triangle, and sinc-squared pulse shapes applied to dilute BECs, we, in some cases, reduce parameter sensitivity by an order of magnitude while maintaining fidelity.
△ Less
Submitted 23 November, 2021;
originally announced November 2021.
-
170 Nanometer Nuclear Magnetic Resonance Imaging using Magnetic Resonance Force Microscopy
Authors:
Kent R. Thurber,
Lee E. Harrell,
Doran D. Smith
Abstract:
We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nanometer slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nanometers. This is achieved by force detection of the magnetic resonance, Magnetic Resonance Force Microscopy (MRFM), in combination with optical pumping to increase the nuclear…
▽ More
We demonstrate one-dimensional nuclear magnetic resonance imaging of the semiconductor GaAs with 170 nanometer slice separation and resolve two regions of reduced nuclear spin polarization density separated by only 500 nanometers. This is achieved by force detection of the magnetic resonance, Magnetic Resonance Force Microscopy (MRFM), in combination with optical pumping to increase the nuclear spin polarization. Optical pumping of the GaAs creates spin polarization up to 12 times larger than the thermal nuclear spin polarization at 5 K and 4 T. The experiment is sensitive to sample volumes containing $\sim 4 \times 10^{11}$ $^{71}$Ga$/\sqrt{Hz}$. These results demonstrate the ability of force-detected magnetic resonance to apply magnetic resonance imaging to semiconductor devices and other nanostructures.
△ Less
Submitted 23 October, 2002;
originally announced October 2002.
-
Temperature measurement at the end of a cantilever using oxygen paramagnetism in solid air
Authors:
Kent R. Thurber,
Lee E. Harrell,
Doran D. Smith
Abstract:
We demonstrate temperature measurement of a sample attached to the end of a cantilever using cantilever magnetometry of solid air ``contamination'' of the sample surface. In experiments like our Magnetic Resonance Force Microscopy (MRFM), the sample is mounted at the end of a thin cantilever with small thermal conductance. Thus, the sample can be at a significantly different temperature than the…
▽ More
We demonstrate temperature measurement of a sample attached to the end of a cantilever using cantilever magnetometry of solid air ``contamination'' of the sample surface. In experiments like our Magnetic Resonance Force Microscopy (MRFM), the sample is mounted at the end of a thin cantilever with small thermal conductance. Thus, the sample can be at a significantly different temperature than the bulk of the instrument. Using cantilever magnetometry of the oxygen paramagnetism in solid air provides the temperature of the sample, without any modifications to our MRFM (Magnetic Resonance Force Microscopy) apparatus.
△ Less
Submitted 23 October, 2002;
originally announced October 2002.