Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
Electron-ion recombination in composite interactions in liquid xenon
Authors:
J. Xu,
J. Kim,
B. Lenardo,
C. E. Dahl,
R. L. Mannino,
G. M. Blockinger,
C. A. Hardy,
D. Adams,
C. S. Amarasinghe,
W. H. Lippincott,
M. Szydagis,
C. Levy,
R. Essig
Abstract:
The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions…
▽ More
The response of liquid xenon to various types of ionizing radiation has been extensively studied theoretically and experimentally. Recent progress in direct detection dark matter experiments highlights the significance of composite events, where multiple particles interact with xenon simultaneously and generate overlapping ionization signatures. In these events, recombination of electrons and ions associated with different primary particles leads to additional suppression of the ionization signal, introducing a new source of uncertainty in dark matter searches and Migdal effect studies. We developed a model to estimate the recombination enhancement for overlapping low-energy particle interactions. This method, which has minimal dependence on xenon microphysics and is primarily driven by existing experimental data, yields predictions that are consistent with available measurements of composite interactions. Furthermore, we demonstrate that the model predictions are robust against xenon microphysics assumptions.
△ Less
Submitted 10 March, 2025;
originally announced March 2025.
-
Search for new interactions at the micron scale with a vector force sensor
Authors:
Gautam Venugopalan,
Clarke A. Hardy,
Kenneth Kohn,
Yuqi Zhu,
Charles P. Blakemore,
Alexander Fieguth,
Jacqueline Huang,
Chengjie Jia,
Meimei Liu,
Lorenzo Magrini,
Nadav Priel,
Zhengruilong Wang,
Giorgio Gratta
Abstract:
The search for new gravity-like interactions at the sub-millimeter scale is a compelling area of research, with important implications for the understanding of classical gravity and its connections with quantum physics. We report improved constraints on Yukawa-type interactions in the $10\,\mathrm{μm}$ regime using optically levitated dielectric microspheres as test masses. The search is performed…
▽ More
The search for new gravity-like interactions at the sub-millimeter scale is a compelling area of research, with important implications for the understanding of classical gravity and its connections with quantum physics. We report improved constraints on Yukawa-type interactions in the $10\,\mathrm{μm}$ regime using optically levitated dielectric microspheres as test masses. The search is performed, for the first time, sensing multiple spatial components of the force vector, and with sensitivity improved by a factor of $\sim 100$ with respect to previous measurements using the same technique. The resulting upper limit on the strength of a hypothetical new force is $10^7$ at a Yukawa range $λ\simeq 5\;μ$m and close to $10^6$ for $λ\gtrsim 10\;μ$m. This result also advances our efforts to measure gravitational effects using micrometer-size objects, with important implications for embryonic ideas to investigate the quantum nature of gravity.
△ Less
Submitted 17 December, 2024;
originally announced December 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.