-
Flow and thermal modelling of the argon volume in the DarkSide-20k TPC
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem
, et al. (279 additional authors not shown)
Abstract:
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we…
▽ More
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (~40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of $^{83\text{m}}$Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
Quality Assurance and Quality Control of the $26~\text{m}^2$ SiPM production for the DarkSide-20k dark matter experiment
Authors:
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli. E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem,
S. Blua,
V. Bocci,
W. Bonivento
, et al. (267 additional authors not shown)
Abstract:
DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes…
▽ More
DarkSide-20k is a novel liquid argon dark matter detector currently under construction at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) that will push the sensitivity for Weakly Interacting Massive Particle (WIMP) detection into the neutrino fog. The core of the apparatus is a dual-phase Time Projection Chamber (TPC), filled with \SI{50} {tonnes} of low radioactivity underground argon (UAr) acting as the WIMP target. NUV-HD-cryo Silicon Photomultipliers (SiPM)s designed by Fondazione Bruno Kessler (FBK) (Trento, Italy) were selected as the photon sensors covering two $10.5~\text{m}^2$ Optical Planes, one at each end of the TPC, and a total of $5~\text{m}^2$ photosensitive surface for the liquid argon veto detectors. This paper describes the Quality Assurance and Quality Control (QA/QC) plan and procedures accompanying the production of FBK~NUV-HD-cryo SiPM wafers manufactured by LFoundry s.r.l. (Avezzano, AQ, Italy). SiPM characteristics are measured at 77~K at the wafer level with a custom-designed probe station. As of March~2025, 1314 of the 1400 production wafers (94% of the total) for DarkSide-20k were tested. The wafer yield is $93.2\pm2.5$\%, which exceeds the 80\% specification defined in the original DarkSide-20k production plan.
△ Less
Submitted 19 March, 2025; v1 submitted 25 December, 2024;
originally announced December 2024.
-
Demonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector
Authors:
V. Gupta,
G. R. Araujo,
M. Babicz,
L. Baudis,
P. -J. Chiu,
S. Choudhary,
M. Goldbrunner,
A. Hamer,
M. Kuźniak,
M. Kuźwa,
A. Leonhardt,
E. Montagna,
G. Nieradka,
H. B. Parkinson,
F. Pietropaolo,
T. R. Pollmann,
F. Resnati,
S. Schönert,
A. M. Szelc,
K. Thieme,
M. Walczak
Abstract:
Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown tha…
▽ More
Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using $4~m^2$ combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.
△ Less
Submitted 26 November, 2024;
originally announced November 2024.
-
Quantitative comparison of TDDFT-calculated HHG yields in ring-shaped organic molecules
Authors:
Stephanie N. Armond,
Kyle A. Hamer,
Ravi Bhardwaj,
Francois Mauger,
Kenneth Lopata,
Kenneth J. Schafer,
Mette B. Gaarde
Abstract:
We compare the high-harmonic-generation (HHG) yield driven by a mid-infrared laser in three organic ring-shaped molecules, calculated using time-dependent density-functional theory (TDDFT). We average the yield over the relative orientation of the molecules and the linearly-polarized, 1825 nm driving laser pulse in order to compare to experimental spectra obtained by Alharbi et al., Phys. Rev. A 9…
▽ More
We compare the high-harmonic-generation (HHG) yield driven by a mid-infrared laser in three organic ring-shaped molecules, calculated using time-dependent density-functional theory (TDDFT). We average the yield over the relative orientation of the molecules and the linearly-polarized, 1825 nm driving laser pulse in order to compare to experimental spectra obtained by Alharbi et al., Phys. Rev. A 92, 041801 (2015). We find that the raw TDDFT-calculated HHG yield in cyclohexane (CHA) is strongly overestimated compared to those of benzene and cyclohexene, and that this can be attributed to unphysically large contributions from CHA orbitals lying well below the highest-occupied molecular orbital. We show that implementing a simple orbital-resolved scaling factor, which corrects the yield of the tunneling ionization contribution to the first step in the HHG process, leads to much better comparisons with experimental results. Our results are encouraging for the use of TDDFT in systematic computations of HHG in large molecules.
△ Less
Submitted 17 September, 2024;
originally announced September 2024.
-
Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (294 additional authors not shown)
Abstract:
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout t…
▽ More
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.
△ Less
Submitted 19 February, 2025; v1 submitted 26 August, 2024;
originally announced August 2024.
-
Strong-field ionization with few-cycle, mid-infrared laser pulses induces a localized ionization followed by long-lasting charge migration in halogenated organic molecules
Authors:
Kyle A. Hamer,
Francois Mauger,
Kenneth Lopata,
Kenneth J. Schafer,
Mette B. Gaarde
Abstract:
We show that applying a few-femtosecond mid-infrared laser pulse parallel to the backbone of a halogenated, conjugated organic molecule induces localized ionization followed by long-lasting field-free charge migration (CM). Through time-dependent density-functional theory calculations, we find that this CM is robust with respect to the parameters of the applied laser pulse. We document the spatial…
▽ More
We show that applying a few-femtosecond mid-infrared laser pulse parallel to the backbone of a halogenated, conjugated organic molecule induces localized ionization followed by long-lasting field-free charge migration (CM). Through time-dependent density-functional theory calculations, we find that this CM is robust with respect to the parameters of the applied laser pulse. We document the spatial and temporal origin of the localized hole, which is initiated via strong-field tunnel ionization in the halogen end of the molecule, and near the peak of the laser electric field. In bromobutadiyne we find a range of wavelengths around $1500~\text{nm}$ that consistently leads to the initiation of high-contrast CM. In addition, we show that the inclusion of Ehrenfest nuclear dynamics does not disrupt the creation of the localized hole, nor the subsequent CM motion, in bromobutadiyne or \emph{para}-bromoaniline.
△ Less
Submitted 8 August, 2024;
originally announced August 2024.
-
Scintillation Light in SBND: Simulation, Reconstruction, and Expected Performance of the Photon Detection System
Authors:
SBND Collaboration,
P. Abratenko,
R. Acciarri,
C. Adams,
L. Aliaga-Soplin,
O. Alterkait,
R. Alvarez-Garrote,
C. Andreopoulos,
A. Antonakis,
L. Arellano,
J. Asaadi,
W. Badgett,
S. Balasubramanian,
V. Basque,
A. Beever,
B. Behera,
E. Belchior,
M. Betancourt,
A. Bhat,
M. Bishai,
A. Blake,
B. Bogart,
J. Bogenschuetz,
D. Brailsford,
A. Brandt
, et al. (158 additional authors not shown)
Abstract:
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its…
▽ More
SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Directionality of nuclear recoils in a liquid argon time projection chamber
Authors:
The DarkSide-20k Collaboration,
:,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
M. Ave,
I. Ch. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado-Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
V. Bocci,
W. M. Bonivento,
B. Bottino,
M. G. Boulay,
J. Busto,
M. Cadeddu
, et al. (243 additional authors not shown)
Abstract:
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scint…
▽ More
The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level
△ Less
Submitted 28 July, 2023;
originally announced July 2023.
-
Tracking Charge Migration with Frequency-Matched Strobo-Spectroscopy
Authors:
Kyle A. Hamer,
Aderonke S. Folorunso,
Kenneth Lopata,
Kenneth J. Schafer,
Mette B. Gaarde,
Francois Mauger
Abstract:
We present frequency-matched strobo-spectroscopy (FMSS) of charge migration (CM) in bromobutadiyne, simulated with time-dependent density-functional theory. CM+FMSS is a pump-probe scheme that uses a frequency-matched HHG-driving laser as an independent probe step following the creation of a localized hole on the bromine atom that induces CM dynamics. We show that the delay-dependent harmonic yiel…
▽ More
We present frequency-matched strobo-spectroscopy (FMSS) of charge migration (CM) in bromobutadiyne, simulated with time-dependent density-functional theory. CM+FMSS is a pump-probe scheme that uses a frequency-matched HHG-driving laser as an independent probe step following the creation of a localized hole on the bromine atom that induces CM dynamics. We show that the delay-dependent harmonic yield tracks the phase of the CM dynamics through its sensitivity to the amount of electron density on the bromine end of the molecule. FMSS takes advantage of the intrinsic attosecond time resolution of the HHG process, in which different harmonics are emitted at different times and thus probe different locations of the electron hole. Finally, we show that the CM-induced modulation of the HHG signal is dominated by the recombination step of the HHG process, with negligible contribution from the ionization step.
△ Less
Submitted 10 October, 2023; v1 submitted 26 June, 2023;
originally announced June 2023.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Attochemistry Regulation of Charge Migration
Authors:
Aderonke S. Folorunso,
François Mauger,
Kyle A. Hamer,
Denawakage D Jayasinghe,
Imam Wahyutama,
Justin R. Ragains,
Robert R. Jones,
Louis F. DiMauro,
Mette B. Gaarde,
Kenneth J. Schafer,
Kenneth Lopata
Abstract:
Charge migration (CM) is a coherent attosecond process that involves the movement of localized holes across a molecule. To determine the relationship between a molecule's structure and the CM dynamics it exhibits, we perform systematic studies of para-functionalized bromobenzene molecules (X-C$_6$H$_4$-R) using real-time time-dependent density functional theory. We initiate valence-electron dynami…
▽ More
Charge migration (CM) is a coherent attosecond process that involves the movement of localized holes across a molecule. To determine the relationship between a molecule's structure and the CM dynamics it exhibits, we perform systematic studies of para-functionalized bromobenzene molecules (X-C$_6$H$_4$-R) using real-time time-dependent density functional theory. We initiate valence-electron dynamics by emulating rapid strong-field ionization leading to a localized hole on the bromine atom. The resulting CM, which takes on the order of 1 fs, occurs via an X localized to C$_6$H$_4$ delocalized to R localized mechanism. Interestingly, the hole contrast on the acceptor functional group increases with increasing electron donating strength. This trend is well-described by the Hammett sigma value of the group, which is a commonly used metric for quantifying the effect of functionalization on the chemical reactivity of benzene derivatives. These results suggest that simple attochemistry principles and a density-based picture can be used to predict and understand CM.
△ Less
Submitted 12 July, 2022;
originally announced July 2022.
-
Characterizing Particle-Like Charge Migration Dynamics with High-Harmonic Sideband Spectroscopy
Authors:
Kyle A. Hamer,
Francois Mauger,
Aderonke S. Folorunso,
Kenneth Lopata,
Robert R. Jones,
Louis F. DiMauro,
Kenneth J. Schafer,
Mette B. Gaarde
Abstract:
We introduce high-harmonic sideband spectroscopy (HHSS) and show that it can be a robust probe of attosecond charge migration (CM) in a halogenated carbon-chain molecule. We simulate both the CM and harmonic-generation (HHG) dynamics using ab initio time-dependent density-functional theory. We find that CM dynamics initiated along the molecular backbone induces sidebands in the HHG spectrum driven…
▽ More
We introduce high-harmonic sideband spectroscopy (HHSS) and show that it can be a robust probe of attosecond charge migration (CM) in a halogenated carbon-chain molecule. We simulate both the CM and harmonic-generation (HHG) dynamics using ab initio time-dependent density-functional theory. We find that CM dynamics initiated along the molecular backbone induces sidebands in the HHG spectrum driven by a delayed laser pulse that is polarized perpendicular to the molecular axis. Monitoring the spectrum as either the HHG laser frequency or the relative delay is scanned allows for the extraction of detailed information about the time-domain characteristics of the CM process.
△ Less
Submitted 12 May, 2022; v1 submitted 1 February, 2022;
originally announced February 2022.