RAIDER: Rapid, anatomy-independent, deep learning-based PDFF and R2* estimation using magnitude-only signals
Authors:
T. J. P. Bray,
G. V. Minore,
A. Bainbridge,
L. Dwyer-Hemmings,
S. A. Taylor,
M. A. Hall-Craggs,
H. Zhang
Abstract:
Purpose: There has been substantial recent interest in magnitude-based fitting methods for estimating proton density fat fraction (PDFF) and R2* from chemical shift-encoded MRI data, since these methods can still be used when complex-based methods fail or when phase data are inaccessible or unreliable, and may also be used as a final processing step with complex-based methods. However, conventiona…
▽ More
Purpose: There has been substantial recent interest in magnitude-based fitting methods for estimating proton density fat fraction (PDFF) and R2* from chemical shift-encoded MRI data, since these methods can still be used when complex-based methods fail or when phase data are inaccessible or unreliable, and may also be used as a final processing step with complex-based methods. However, conventional fitting techniques are computationally expensive. Deep learning (DL)-based methods promise to accelerate parameter estimation, but previous attempts have used convolutional neural networks (CNNs), which are limited by training requirements and poor generalizability (anatomy-dependence). To address these limitations, we propose RAIDER, a voxelwise method for rapid, anatomy-independent deep learning-based PDFF and R2* estimation using multi-echo magnitude-data. Theory and Methods: RAIDER uses two multilayer perceptrons, each trained separately with simulated single-voxel multi-echo magnitude signals, to estimate PDFF and R2*. The use of two networks, each with restricted training distribution, solves the problem of degeneracy during training. During inference, the solution from one of the two networks is chosen based on likelihood. Performance and speed are investigated in a series of simulation experiments, in phantoms and in vivo. Results: RAIDER is 285-1450 times faster than conventional magnitude fitting, taking 1.4-2.3s per slice rather than 8-56minutes, and offers performance similar to conventional fitting. It produces accurate PDFF measurements in phantoms and in vivo images with different anatomies, despite having been trained only on simulation data. Conclusion: RAIDER can substantially accelerate magnitude-based PDFF and R2* estimation, whilst avoiding intrinsic limitations of CNN-based methods.
△ Less
Submitted 12 May, 2025; v1 submitted 2 March, 2024;
originally announced March 2024.
-
Negative-contrast neurography: Imaging the extracranial facial nerve and its branches using contrast-enhanced variable flip angle turbo spin echo MRI
Authors:
Timothy JP Bray,
Emma A Lim,
Susan Jawad,
Sumandeep Kaur,
Sofia Otero,
Timothy J Beale,
Mark McGurk,
Alan Bainbridge,
Margaret A Hall-Craggs,
Simon J Morley
Abstract:
Background and Purpose: Various 'positive-contrast' neurographic methods have been investigated for imaging the extracranial course of the facial nerve. However, nerve visibility can be inconsistent with these sequences and may depend on the composition of the parotid gland, limiting consistent identification. To address this, we describe and evaluate a 'negative-contrast' method for imaging of th…
▽ More
Background and Purpose: Various 'positive-contrast' neurographic methods have been investigated for imaging the extracranial course of the facial nerve. However, nerve visibility can be inconsistent with these sequences and may depend on the composition of the parotid gland, limiting consistent identification. To address this, we describe and evaluate a 'negative-contrast' method for imaging of the extracranial facial nerve using three-dimensional variable flip angle turbo spin echo (VFA-TSE) imaging. We investigate strategies for further optimization, including parotid-specific VFA-TSE optimization and the use of gadolinium-based contrast agent (GBCA). Materials and Methods: 6 healthy volunteers and 10 patients with parotid tumors underwent VFA-TSE and double echo steady state (DESS) imaging of the extracranial facial nerve at 3T. The main trunk, divisions and branches of the extracranial facial nerve were manually segmented by three radiologists, enabling CNR and Hausdorff distance computation and confidence scoring. CNR, Hausdorff distance and confidence scores were compared between sequences and between pre- and post-contrast imaging to evaluate the effect of GBCA. Results: CNR, Hausdorff distances and confidence scores were superior for VFA-TSE compared to DESS imaging. GBCA administration produced a further increase in CNR of nerve against parotid and improved differentiation of nerve from tumor. Conclusion: Imaging of the extracranial facial nerve with VFA-TSE depicts the nerve as a low signal structure ('black nerve') against the high signal parotid parenchyma ('white parotid') and outperforms positive-contrast DESS imaging in terms of CNR, segmentation consistency and confidence. GBCA further increases negative contrast and improves differentiation of nerve from tumor.
△ Less
Submitted 31 March, 2021; v1 submitted 24 March, 2021;
originally announced March 2021.
-
Task-driven assessment of experimental designs in diffusion MRI: a computational framework
Authors:
Sean C. Epstein,
Timothy J. P. Bray,
Margaret A. Hall-Craggs,
Hui Zhang
Abstract:
This paper proposes a task-driven computational framework for assessing diffusion MRI experimental designs which, rather than relying on parameter-estimation metrics, directly measures quantitative task performance. Traditional computational experimental design (CED) methods may be ill-suited to experimental tasks, such as clinical classification, where outcome does not depend on parameter-estimat…
▽ More
This paper proposes a task-driven computational framework for assessing diffusion MRI experimental designs which, rather than relying on parameter-estimation metrics, directly measures quantitative task performance. Traditional computational experimental design (CED) methods may be ill-suited to experimental tasks, such as clinical classification, where outcome does not depend on parameter-estimation accuracy or precision alone. Current assessment metrics evaluate experiments' ability to faithfully recover microstructural parameters rather than their task performance. The method we propose addresses this shortcoming. For a given MRI experimental design, experiments are simulated start-to-finish and task performance is computed from ROC curves and associated summary metrics (e.g. AUC). Two experiments were performed: first, a validation of the pipeline's task performance predictions against clinical results, comparing in-silico predictions to real-world ROC/AUC; and second, a demonstration of the pipeline's advantages over traditional CED approaches, using two simulated clinical classification tasks. Comparison with clinical datasets validates our method's predictions of (a) the qualitative form of ROC curves, (b) the relative task performance of different experimental designs, and (c) the absolute performance of each experimental design. Furthermore, we show that our method outperforms traditional task-agnostic assessment methods, enabling improved, more useful experimental design. Compared to current approaches, such task-driven assessment is more likely to identify experimental designs that perform well in practice. Our method is not limited to diffusion MRI; the pipeline generalises to any task-based quantitative MRI application, and provides the foundation for developing future task-driven end-to end CED frameworks.
△ Less
Submitted 16 September, 2021; v1 submitted 15 March, 2021;
originally announced March 2021.