A Cryogenic Torsion Balance Using a Liquid-Cryogen Free, Ultra-Low Vibration Cryostat
Authors:
S. M. Fleischer,
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
E. A. Shaw,
E. Swanson,
B. R. Heckel,
J. H. Gundlach
Abstract:
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency…
▽ More
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.
△ Less
Submitted 8 November, 2022; v1 submitted 6 June, 2022;
originally announced June 2022.
-
A Low-Frequency Torsion Pendulum with Interferometric Readout
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
C. J. Leupold,
P. W. F. Forsyth,
J. D. Wegner,
E. A. Shaw,
J. G. Lee,
J. H. Gundlach
Abstract:
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rota…
▽ More
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.
△ Less
Submitted 20 April, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Inter-Party Avalanche Involvements May Increase Quadratically With Party Density
Authors:
Charles A. Hagedorn
Abstract:
We estimate, from first-principles, the rate of inter-party avalanche involvements. The model suggests that the likelihood of inter-party involvements is quadratic in the density of parties -- twice as many parties quadruples the likelihood. The model predicts that when the product of the party-density and the area of a day's potential avalanches approaches one, inter-party avalanche involvements…
▽ More
We estimate, from first-principles, the rate of inter-party avalanche involvements. The model suggests that the likelihood of inter-party involvements is quadratic in the density of parties -- twice as many parties quadruples the likelihood. The model predicts that when the product of the party-density and the area of a day's potential avalanches approaches one, inter-party avalanche involvements will become a substantial fraction of all avalanche involvements. As a corollary, the relative rate of inter-party involvements is expected to increase with avalanche size. We argue, with selected North American inter-party incidents from 2001-2019, that inter-party involvements are a timely concern. To spur conversation, we enumerate a variety of strategies that may mitigate inter-party hazard.
△ Less
Submitted 23 October, 2019;
originally announced October 2019.
-
Low Frequency Tilt Seismology with a Precision Ground Rotation Sensor
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
J. H. Gundlach,
J. S. Kissel,
J. Warner,
H. Radkins,
T. J. Shaffer,
M. W. Coughlin,
P. Bodin
Abstract:
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rot…
▽ More
We describe measurements of the rotational component of teleseismic surface waves using an inertial high-precision ground-rotation-sensor installed at the LIGO Hanford Observatory (LHO). The sensor has a noise floor of 0.4 nrad$/ \sqrt{\rm Hz}$ at 50 mHz and a translational coupling of less than 1 $μ$rad/m enabling translation-free measurement of small rotations. We present observations of the rotational motion from Rayleigh waves of six teleseismic events from varied locations and with magnitudes ranging from M6.7 to M7.9. These events were used to estimate phase dispersion curves which shows agreement with a similar analysis done with an array of three STS-2 seismometers also located at LHO.
△ Less
Submitted 25 July, 2017; v1 submitted 10 July, 2017;
originally announced July 2017.
-
A high-precision mechanical absolute-rotation sensor
Authors:
Krishna Venkateswara,
Charles A. Hagedorn,
Matthew D. Turner,
Trevor Arp,
Jens H. Gundlach
Abstract:
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above…
▽ More
We have developed a mechanical absolute-rotation sensor capable of resolving ground rotation angle of less than 1 nrad$/\sqrt{\text{Hz}}$ above $30$ mHz and 0.2 nrad$/\sqrt{\text{Hz}}$ above $100$ mHz about a single horizontal axis. The device consists of a meter-scale beam balance, suspended by a pair of flexures, with a resonance frequency of 10.8 mHz. The center of mass is located 3 $μ$m above the pivot, giving an excellent horizontal displacement rejection of better than $3\times10^{-5}$ rad/m. The angle of the beam is read out optically using a high-sensitivity autocollimator. We have also built a tiltmeter with better than 1 nrad$/\sqrt{\text{Hz}}$ sensitivity above 30 mHz. Co-located measurements using the two instruments allowed us to distinguish between background rotation signal at low frequencies and intrinsic instrument noise. The rotation sensor is useful for rotational seismology and for rejecting background rotation signal from seismometers in experiments demanding high levels of seismic isolation, such as Advanced LIGO.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
A reference-beam autocollimator with nanoradian sensitivity from mHz to kHz and dynamic range of 10^7
Authors:
T. B. Arp,
C. A. Hagedorn,
S. Schlamminger,
J. H. Gundlach
Abstract:
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressi…
▽ More
We describe an autocollimating optical angle sensor with a dynamic range of 9 mrad and nrad/sqrt(Hz) sensitivity at frequencies from 5 mHz to 3 kHz. This work improves the standard multi-slit autocollimator design by adding two optical components, a reference mirror and a condensing lens. This autocollimator makes a differential measurement between a reference mirror and a target mirror, suppressing common-mode noise sources. The condensing lens reduces optical aberrations, increases intensity, and improves image quality. To further improve the stability of the device at low frequencies the body of the autocollimator is designed to reduce temperature variations and their effects. A new data processing technique was developed in order to suppress the effects of imperfections in the CCD.
△ Less
Submitted 18 September, 2013;
originally announced September 2013.
-
Brownian force noise from molecular collisions and the sensitivity of advanced gravitational wave observatories
Authors:
R. Dolesi,
M. Hueller,
D. Nicolodi,
D. Tombolato,
S. Vitale,
P. J. Wass,
W. J. Weber,
M. Evans,
P. Fritschel,
R. Weiss,
J. H. Gundlach,
C. A. Hagedorn,
S. Schlamminger,
G. Ciani,
A. Cavalleri
Abstract:
We present an analysis of Brownian force noise from residual gas damping of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitationa…
▽ More
We present an analysis of Brownian force noise from residual gas damping of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitational wave observatory, where the relevant test mass is a suspended 340 mm diameter cylindrical end mirror, the force noise power is increased by roughly a factor 40 by the presence of a similarly shaped reaction mass at a nominal separation of 5 mm. The force noise, of order 20 fN\rthz\ for $2 \times 10^{-6}$ Pa of residual H$_2$ gas, rivals quantum optical fluctuations as the dominant noise source between 10 and 30 Hz. We present here a numerical and analytical analysis for the gas damping force noise for Advanced LIGO, backed up by experimental evidence from several recent measurements. Finally, we discuss the impact of residual gas damping on the gravitational wave sensitivity and possible mitigation strategies.
△ Less
Submitted 30 September, 2011; v1 submitted 16 August, 2011;
originally announced August 2011.
-
Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification
Authors:
Matthew D. Turner,
Charles A. Hagedorn,
Stephan Schlamminger,
Jens H. Gundlach
Abstract:
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per ro…
▽ More
We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 hertz.
△ Less
Submitted 22 March, 2011;
originally announced March 2011.
-
Indirect Evidence for Lévy Walks in Squeeze Film Damping
Authors:
Stephan Schlamminger,
Charles A. Hagedorn,
Jens H. Gundlach
Abstract:
Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' damping. Measured quality factors derived from free decay of oscillation are c…
▽ More
Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and MEMS devices. We used two torsion balance instruments to measure the strength and distance-dependence of `squeeze film' damping. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Lévy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film damping observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film damping of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between 1/d and 1/d^2.
△ Less
Submitted 29 May, 2010; v1 submitted 26 May, 2010;
originally announced May 2010.