-
Data-Driven Molecular Dynamics and TEM Analysis of Platinum Crystal Growth on Graphene and Reactive Hydrogen-Sensing Dynamics
Authors:
Akram Ibrahim,
Ahmed M. Hafez,
Mahmooda Sultana,
Can Ataca
Abstract:
Pt-functionalized graphene harnesses graphene's exceptional carrier mobility with Pt's catalytic activity for hydrogen sensing, yet the mechanisms of Pt crystal growth, its interaction with graphene, and the consequent impact on hydrogen sensitivity remain incompletely understood. We develop a high-fidelity equivariant machine-learned interatomic potential (MLIP) to perform large-scale molecular d…
▽ More
Pt-functionalized graphene harnesses graphene's exceptional carrier mobility with Pt's catalytic activity for hydrogen sensing, yet the mechanisms of Pt crystal growth, its interaction with graphene, and the consequent impact on hydrogen sensitivity remain incompletely understood. We develop a high-fidelity equivariant machine-learned interatomic potential (MLIP) to perform large-scale molecular dynamics (MD) simulations with near-density functional theory (DFT) accuracy. Our simulations capture key growth stages-including Pt nucleation, coalescence, and the formation of either polycrystalline clusters or epitaxial thin films-under varying deposition loadings and rates. Transmission electron microscopy and Raman measurements validate the predicted morphologies, revealing small approximately spherical clusters at lower Pt loadings that evolve into slightly thicker, more planar domains with increased loading. Reactive MD shows hydrogen dissociates predominantly on Pt nanostructures at room temperature, with minimal spillover onto pristine graphene. Furthermore, hydrogen uptake increases with Pt loading at a diminishing rate, while reaction kinetics are significantly faster at lower coverages and rapidly decline with increasing loading. DFT calculations indicate undercoordinated Pt clusters induce $n$-type doping in graphene, which is diminished when hydrogen adsorption depletes Pt electron density, thereby transducing the adsorption events from Pt-surfaces to the Pt-graphene interface. By correlating deposition conditions, nanostructure morphology, and hydrogen sensing dynamics, our findings suggest that moderate Pt loadings can effectively balance sufficient doping with a pronounced Pt-mediated electronic response to graphene. These insights underscore the importance of combining DFT and MLIP simulations with experiments to guide next-generation chemiresistive gas sensor design.
△ Less
Submitted 7 April, 2025;
originally announced April 2025.
-
Effects of distinct ion temperatures on the head-on collision and phase shifts of dust acoustic one and multi-solitons in dusty plasmas
Authors:
M. S. Alam,
M. G. Hafez,
M. R. Talukder,
M. Hossain Ali
Abstract:
The propagation characteristics and interactions between the dust acoustic (DA) one and multi solitons in an unmagnetized dusty plasmas composing negatively charged mobile dust, Boltzmann distributed electrons, nonextensive distributed cold and nonthermal distributed hot ions are studied. The well known extended Poincar Lighthill Kuo (PLK) method is employed to derive the two sided Korteweg de Vri…
▽ More
The propagation characteristics and interactions between the dust acoustic (DA) one and multi solitons in an unmagnetized dusty plasmas composing negatively charged mobile dust, Boltzmann distributed electrons, nonextensive distributed cold and nonthermal distributed hot ions are studied. The well known extended Poincar Lighthill Kuo (PLK) method is employed to derive the two sided Korteweg de Vries (KdV) equations. The solutions of KdV equations are constructed using the Hirota method both for one and multi solitons. The phase shifts are determined for the interaction of one, two and three DA solitons. The effects of plasma parameters on the head on collision of DA one as well as multi solitons and their corresponding phase shifts are investigated.
△ Less
Submitted 30 November, 2016;
originally announced November 2016.
-
Characterization of atmospheric pressure H2O/O2 gliding arc plasma for the production of OH and O radicals
Authors:
N. C. Roy,
M. G. Hafez,
M R Talukder
Abstract:
Atmospheric pressure steam/oxygen plasma is generated by a 88 Hz, 6kV AC power supply. The properties of the produced plasma are investigated by optical emission spectroscopy (OES). The relative intensity, rotational, vibrational, excitation temperatures and electron density are studied as function of applied voltage, electrode spacing and oxygen flow rate. The rotational and vibrational temperatu…
▽ More
Atmospheric pressure steam/oxygen plasma is generated by a 88 Hz, 6kV AC power supply. The properties of the produced plasma are investigated by optical emission spectroscopy (OES). The relative intensity, rotational, vibrational, excitation temperatures and electron density are studied as function of applied voltage, electrode spacing and oxygen flow rate. The rotational and vibrational temperatures are determined simulating the bands with the aid of LIFBASE simulation software. The excitation temperature is obtained from the CuI transition taking non-thermal equilibrium condition into account employing intensity ratio method. The electron density is approximated from the H_α Stark broadening using the Voigt profile fitting method. It is observed that the rotational and vibrational temperatures are decreased with increasing electrode spacing and O2 flow rate, but increased with the applied voltage. The excitation temperature is found to increase with increasing applied voltage and O2 flow rate, but decrease with electrode spacing. The electron density is increased with increasing applied voltage while it seems to downward trend with increasing electrode spacing and O2 flow rate.
△ Less
Submitted 3 July, 2016; v1 submitted 14 April, 2016;
originally announced April 2016.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
Acoustic Wave Approach for Multi-Touch Tactile Sensing
Authors:
Yuan Liu,
Jean-Pierre Nikolovski,
Moustapha Hafez,
Nazih Mechbal,
Michel Vergé
Abstract:
In this communication, we present a high resolution tactile plate that can localize one or two contact fingers. The localization principle is based on Lamb wave absorption. Fingers' contact will generate absorption signals while Lamb waves are propagating in a thin finite copper plate. These signals can be related to the contact positions and can be calibrated before the use of tactile plate. Fi…
▽ More
In this communication, we present a high resolution tactile plate that can localize one or two contact fingers. The localization principle is based on Lamb wave absorption. Fingers' contact will generate absorption signals while Lamb waves are propagating in a thin finite copper plate. These signals can be related to the contact positions and can be calibrated before the use of tactile plate. Fingers' contact positions are calculated by finding the closest calibration signal to the measured signal. Positions are carried out in less than 10 ms with a spatial resolution of 2 mm for one finger localization. Multi-points localization by this technology is developed and a two-point case is initialized and tested. Several optimization methods are also presented in this paper, as the double validation check which could improve the accuracy of single-point localization from 94.63% to 99.5%.
△ Less
Submitted 18 September, 2009;
originally announced September 2009.