-
Best Thermoelectric Efficiency of Ever-Explored Materials
Authors:
Byungki Ryu,
Jaywan Chung,
Masaya Kumagai,
Tomoya Mato,
Yuki Ando,
Sakiko Gunji,
Atsumi Tanaka,
Dewi Yana,
Masayuki Fujimoto,
Yoji Imai,
Yukari Katsura,
SuDong Park
Abstract:
A thermoelectric device is a heat engine that directly converts heat into electricity. Many materials with a high figure of merit ZT have been discovered in anticipation of a high thermoelectric efficiency. However, there has been a lack of investigations on efficiency-based material evaluation, and little is known about the achievable limit of thermoelectric efficiency. Here, we report the highes…
▽ More
A thermoelectric device is a heat engine that directly converts heat into electricity. Many materials with a high figure of merit ZT have been discovered in anticipation of a high thermoelectric efficiency. However, there has been a lack of investigations on efficiency-based material evaluation, and little is known about the achievable limit of thermoelectric efficiency. Here, we report the highest thermoelectric efficiency using 12,645 published materials. The 97,841,810 thermoelectric efficiencies are calculated using 808,610 device configurations under various heat-source temperatures (T_h) when the cold-side temperature is 300 K, solving one-dimensional thermoelectric integral equations with temperature-dependent thermoelectric properties. For infinite-cascade devices, a thermoelectric efficiency larger than 33% (~1/3) is achievable when T_h exceeds 1400 K. For single-stage devices, the best efficiency of 17.1% (~1/6) is possible when T_h is 860 K. Leg segmentation can overcome this limit, delivering a very high efficiency of 24% (~1/4) when T_h is 1100 K.
△ Less
Submitted 14 March, 2023; v1 submitted 17 October, 2022;
originally announced October 2022.
-
A Technique for Estimating the Absolute Gain of a Photomultiplier Tube
Authors:
M. Takahashi,
Y. Inome,
S. Yoshii,
A. Bamba,
S. Gunji,
D. Hadasch,
M. Hayashida,
H. Katagiri,
Y. Konno,
H. Kubo,
J. Kushida,
D. Nakajima,
T. Nakamori,
T. Nagayoshi,
K. Nishijima,
S. Nozaki,
D. Mazin,
S. Mashuda,
R. Mirzoyan,
H. Ohoka,
R. Orito,
T. Saito,
S. Sakurai,
J. Takeda,
M. Teshima
, et al. (4 additional authors not shown)
Abstract:
Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the photoelectrons have been multiplied. To obtain this amplification factor, we have developed a procedure for estimating precisely the signal caused by a single photo…
▽ More
Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the photoelectrons have been multiplied. To obtain this amplification factor, we have developed a procedure for estimating precisely the signal caused by a single photoelectron. The method utilizes the fact that the photoelectrons conform to a Poisson distribution. The average signal produced by a single photoelectron can then be estimated from the number of noise events, without requiring analysis of the distribution of the signal produced by a single photoelectron. The signal produced by one or more photoelectrons can be estimated experimentally without any assumptions. This technique, and an example of the analysis of a signal from a photomultiplier tube, are described in this study.
△ Less
Submitted 27 April, 2018;
originally announced April 2018.
-
Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope
Authors:
H. Kubo,
R. Paoletti,
Y. Awane,
A. Bamba,
M. Barcelo,
J. A. Barrio,
O. Blanch,
J. Boix,
C. Delgado,
D. Fink,
D. Gascon,
S. Gunji,
R. Hagiwara,
Y. Hanabata,
K. Hatanaka,
M. Hayashida,
M. Ikeno,
S. Kabuki,
H. Katagiri,
J. Kataoka,
Y. Konno,
S. Koyama,
T. Kishimoto,
J. Kushida,
G. Martinez
, et al. (29 additional authors not shown)
Abstract:
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact,…
▽ More
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.
△ Less
Submitted 12 July, 2013;
originally announced July 2013.