Thermal architecture for a cryogenic super-pressure balloon payload: design and development of the Taurus flight cryostat
Authors:
Simon Tartakovsky,
Alexandre E. Adler,
Jason E. Austermann,
Steven J. Benton,
Rick Bihary,
Malcolm Durking,
Shannon M. Duff,
Jeffrey P. Filippini,
Aurelien A. Fraisse,
Thomas J. L. J. Gascard,
Sho M. Gibbs,
Suren Gourapura,
Jon E. Gudmundsson,
John W. Hartley,
Johannes Hubmayr,
William C. Jones,
Steven Li,
Jared L. May,
Johanna M. Nagy,
Kate Okun,
Ivan L. Padilla,
L. Javier Romualdez,
Michael R. Vissers
Abstract:
We describe the cryogenic system being developed for Taurus: a super-pressure balloon-borne microwave polarimeter scheduled to fly in 2027. The Taurus cryogenic system consists of a 660L liquid helium cryostat which achieves a base temperature of <100mK with the help of a capillary-fed superfluid tank and a closed cycle dilution refrigerator. The main tank is supported with fiberglass flexures and…
▽ More
We describe the cryogenic system being developed for Taurus: a super-pressure balloon-borne microwave polarimeter scheduled to fly in 2027. The Taurus cryogenic system consists of a 660L liquid helium cryostat which achieves a base temperature of <100mK with the help of a capillary-fed superfluid tank and a closed cycle dilution refrigerator. The main tank is supported with fiberglass flexures and is encased in two layers of vapor-cooled shields which allow Taurus to make full use of the extended flight time offered by the super-pressure balloon platform. The Taurus cryostat is projected to hold for over 50 days while weighing under 1000lbs. We present the design, testing, and thermal analysis of the Taurus cryogenic systems.
△ Less
Submitted 22 October, 2024;
originally announced October 2024.
-
Reflectance measurements of mm-wave absorbers using frequency-domain continuous wave THz spectroscopy
Authors:
Gaganpreet Singh,
Rustam Balafendiev,
Zeshen Bao,
Thomas J. L. J. Gascard,
Jon E. Gudmundsson,
Gagandeep Kaur,
Vid Primožič
Abstract:
Due to high dynamic range and ease of use, continuous wave terahertz spectroscopy is an increasingly popular method for optical characterization of components used in cosmic microwave background (CMB) experiments. In this work, we describe an optical testbed that enables simultaneous measurements of transmission and reflection properties of various radiation absorbing dielectric materials, essenti…
▽ More
Due to high dynamic range and ease of use, continuous wave terahertz spectroscopy is an increasingly popular method for optical characterization of components used in cosmic microwave background (CMB) experiments. In this work, we describe an optical testbed that enables simultaneous measurements of transmission and reflection properties of various radiation absorbing dielectric materials, essential components in the reduction of undesired optical loading. To demonstrate the performance of the testbed, we have measured the reflection response of five absorbers commonly used for such applications: TKRAM, carbon- and iron-loaded Stycast, HR10, AN72, and an in-house 3D printed absorber across a frequency range of 100 to 500 GHz, for both S- and P-polarization, with incident angles varying from 15 to 45 degrees. We present results on both the specular and scattered reflection response of these absorbers.
△ Less
Submitted 7 July, 2024;
originally announced July 2024.
-
Searching For Dark Matter with Plasma Haloscopes
Authors:
Alexander J. Millar,
Steven M. Anlage,
Rustam Balafendiev,
Pavel Belov,
Karl van Bibber,
Jan Conrad,
Marcel Demarteau,
Alexander Droster,
Katherine Dunne,
Andrea Gallo Rosso,
Jon E. Gudmundsson,
Heather Jackson,
Gagandeep Kaur,
Tove Klaesson,
Nolan Kowitt,
Matthew Lawson,
Alexander Leder,
Akira Miyazaki,
Sid Morampudi,
Hiranya V. Peiris,
Henrik S. Røising,
Gaganpreet Singh,
Dajie Sun,
Jacob H. Thomas,
Frank Wilczek
, et al. (2 additional authors not shown)
Abstract:
We summarise the recent progress of the Axion Longitudinal Plasma HAloscope (ALPHA) Consortium, a new experimental collaboration to build a plasma haloscope to search for axions and dark photons. The plasma haloscope is a novel method for the detection of the resonant conversion of light dark matter to photons. ALPHA will be sensitive to QCD axions over almost a decade of parameter space, potentia…
▽ More
We summarise the recent progress of the Axion Longitudinal Plasma HAloscope (ALPHA) Consortium, a new experimental collaboration to build a plasma haloscope to search for axions and dark photons. The plasma haloscope is a novel method for the detection of the resonant conversion of light dark matter to photons. ALPHA will be sensitive to QCD axions over almost a decade of parameter space, potentially discovering dark matter and resolving the Strong CP problem. Unlike traditional cavity haloscopes, which are generally limited in volume by the Compton wavelength of the dark matter, plasma haloscopes use a wire metamaterial to create a tuneable artificial plasma frequency, decoupling the wavelength of light from the Compton wavelength and allowing for much stronger signals. We develop the theoretical foundations of plasma haloscopes and discuss recent experimental progress. Finally, we outline a baseline design for ALPHA and show that a full-scale experiment could discover QCD axions over almost a decade of parameter space.
△ Less
Submitted 22 March, 2023; v1 submitted 30 September, 2022;
originally announced October 2022.
-
Optical design concept of the CMB-S4 large-aperture telescopes and cameras
Authors:
Patricio A. Gallardo,
Bradford Benson,
John Carlstrom,
Simon R. Dicker,
Nick Emerson,
Jon E. Gudmundsson,
Richard Hills,
Michele Limon,
Jeff McMahon,
Michael D. Niemack,
Johanna M. Nagy,
Stephen Padin,
John Ruhl,
Sara M. Simon,
the CMB-S4 collaboration
Abstract:
CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the la…
▽ More
CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.
△ Less
Submitted 20 July, 2022;
originally announced July 2022.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
Geometrical and physical optics analysis for mm-wavelength refractor telescopes designed to map the cosmic microwave background
Authors:
Jon E. Gudmundsson
Abstract:
We present a compact two-lens HDPE f/1.6 refractor design that is capable of supporting a 28-deg diffraction-limited field of view at 1-mm wavelengths and contrast it to a similar two-lens refractor using silicon lenses. We compare the optical properties of these two systems as predicted by both geometrical and physical optics. The presented analysis suggests that by relaxing telecentricity requir…
▽ More
We present a compact two-lens HDPE f/1.6 refractor design that is capable of supporting a 28-deg diffraction-limited field of view at 1-mm wavelengths and contrast it to a similar two-lens refractor using silicon lenses. We compare the optical properties of these two systems as predicted by both geometrical and physical optics. The presented analysis suggests that by relaxing telecentricity requirements, a plastic two-lens refractor system can perform comparably to a similar silicon system across a wide field of view and wavelengths up to 1 mm. We show that for both telescope designs, cold stop spillover changes significantly across the field of view in a way that is somewhat inconsistent with Gaussian beam formalism and simple f-number scaling. We present results that highlight beam ellipticity dependence on both pixel location and pixel aperture size --- an effect that is challenging to reproduce in standard geometrical optics. We show that a silicon refractor design suffers from larger cross-polarization compared to the HDPE design. Our results address the limitations of solely relying on geometrical optics to assess relative performance of two optical systems. We discuss implications for future refractor designs.
△ Less
Submitted 29 November, 2019;
originally announced November 2019.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.